#!/usr/bin/env bash
|
|
# One turn of the keyboard-focus convergence loop, start to verdict, with no human in it.
|
|
#
|
|
# scripts/CAD/focus-loop.sh # full turn: sync -> build -> restart -> assert
|
|
# SKIP_BUILD=1 scripts/CAD/focus-loop.sh # re-assert against the binary already on the host
|
|
#
|
|
# Exit 0 only when every gate holds. Any other exit is a failing gate and names which.
|
|
#
|
|
# WHY THIS EXISTS. The focus defects in the Design tab were chased for days by hand: build, launch
|
|
# the GUI, drive it with xdotool, read a screenshot, guess, repeat. That needs a person at every
|
|
# step and it is where the days went. This does not: behemoth carries an agent-owned Xvfb :10 with
|
|
# openbox, the app, xdotool and an MCP socket that reports sketch state as JSON, so a turn is
|
|
# sync -> build -> restart -> assert, and the ASSERTION is the verdict, not my reading of a picture.
|
|
#
|
|
# WHY BEHEMOTH AND NOT THE orcacad-gui RIG CONTAINER. The rig was the obvious host and it does not
|
|
# work for this: its image pins a dependency set 216 non-CAD source files behind cad-mainline
|
|
# (assimp among them), so today's CAD sources call GUI_App::is_auto_close_sketch_loops and
|
|
# MainFrame::ensure_design_panel, which that tree has never heard of. Syncing all of src/ to fix
|
|
# that needs a deps rebuild measured in hours. behemoth already builds this exact tree, already
|
|
# runs a WM on :10, and is the machine the user actually runs the product on — so the loop asserts
|
|
# against the shipping artefact rather than a stale twin. Reviving the rig means rebuilding its
|
|
# deps image first; until then it cannot adjudicate anything about this code.
|
|
#
|
|
# SC2029: every ssh command below quotes locally-expanded config (HOST, SRC, DISP) on purpose
|
|
# -- the remote tree is not this checkout and has no such config of its own.
|
|
# shellcheck disable=SC2029
|
|
set -uo pipefail
|
|
|
|
HOST="${HOST:-tommaso@100.103.234.2}"
|
|
DISP="${DISP:-:10}"
|
|
SRC="${SRC:-\$HOME/projects/orca/orcacad-native/src}"
|
|
TRACE="${TRACE:-/tmp/ux-focus-loop.log}"
|
|
REPO="$(cd "$(dirname "${BASH_SOURCE[0]}")/../.." && pwd)"
|
|
BIN="build/src/Release/orca-slicer"
|
|
|
|
say() { printf '\n=== %s\n' "$*"; }
|
|
die() { printf 'GATE FAILED: %s\n' "$*" >&2; exit 1; }
|
|
|
|
ssh -o ConnectTimeout=10 "$HOST" true || die "cannot reach $HOST"
|
|
|
|
# ---------------------------------------------------------------- S1 sync
|
|
# Only the CAD paths and the ladders. behemoth's tree is a full cad-mainline checkout kept in step
|
|
# by its own realign; pushing unrelated files from here would make the build host disagree with
|
|
# git for reasons no later session could reconstruct.
|
|
say "S1 sync"
|
|
rsync -q "$REPO"/src/slic3r/GUI/CAD/*.{cpp,hpp} "$HOST:$SRC/src/slic3r/GUI/CAD/" || die "sync GUI/CAD"
|
|
rsync -q "$REPO"/src/libslic3r/CAD/*.{cpp,hpp} "$HOST:$SRC/src/libslic3r/CAD/" || die "sync libslic3r/CAD"
|
|
rsync -q "$REPO"/scripts/CAD/check-gui-click-edit.py "$REPO"/scripts/CAD/check-gui-sketching.py \
|
|
"$HOST:/tmp/" || die "sync ladders"
|
|
echo " sources + ladders in place"
|
|
|
|
# ---------------------------------------------------------------- S2 build
|
|
# flock: two concurrent Orca builds once OOM'd this machine for 2h28m. Every build script on the
|
|
# fleet takes this same lock.
|
|
#
|
|
# Grade the BINARY'S TIMESTAMP, never the build command's exit code. This is a Ninja Multi-Config
|
|
# tree whose default rules are Debug while the artefact under test is Release, so a wrong-config
|
|
# invocation returns success in seconds having touched nothing — it cost a wasted cycle here
|
|
# before anyone thought to look at the file.
|
|
if [ -z "${SKIP_BUILD:-}" ]; then
|
|
say "S2 build"
|
|
before=$(ssh "$HOST" "stat -c %Y $SRC/$BIN 2>/dev/null || echo 0")
|
|
ssh "$HOST" "flock /tmp/orca-rig-build.lock \$HOME/projects/orca/orcacad-native/rebuild.sh > /tmp/focus-build.log 2>&1"
|
|
rc=$?
|
|
after=$(ssh "$HOST" "stat -c %Y $SRC/$BIN 2>/dev/null || echo 0")
|
|
if [ "$rc" != 0 ] || [ "$after" = "$before" ]; then
|
|
ssh "$HOST" "grep -m5 -B2 'error:' /tmp/focus-build.log; tail -5 /tmp/focus-build.log"
|
|
die "S2 build (exit $rc, binary $( [ "$after" = "$before" ] && echo unchanged || echo rebuilt ))"
|
|
fi
|
|
echo " built"
|
|
fi
|
|
|
|
# ---------------------------------------------------------------- S3 F2P
|
|
# The ladder launches and tears down the app itself, in its own datadir, so nothing here has to
|
|
# manage a process. It types WITHOUT clicking the field first, which is the whole contract.
|
|
say "S3 fail-to-pass: type without clicking the field"
|
|
ssh "$HOST" "cd $SRC && DISPLAY=$DISP python3 /tmp/check-gui-click-edit.py \
|
|
--display $DISP --bin $BIN --trace $TRACE"
|
|
f2p=$?
|
|
|
|
# ---------------------------------------------------------------- S4 P2P
|
|
say "S4 pass-to-pass: the existing gesture ladder"
|
|
ssh "$HOST" "cd $SRC && DISPLAY=$DISP python3 /tmp/check-gui-sketching.py 2>&1 | tail -3"
|
|
p2p=$?
|
|
|
|
say "VERDICT"
|
|
[ "$f2p" = 0 ] || die "F2P: a tool did not take the typed value (exit $f2p)"
|
|
[ "$p2p" = 0 ] || die "P2P: the gesture ladder regressed (exit $p2p)"
|
|
echo "ALL GATES HELD"
|