Keep the shared task progress aligned with agent
reports that lack Bambu cloud task identity.
Release the lazily allocated task during reset to
avoid leaks when machine objects reconnect.
The U1 exposes no /server/webcams/list entry;
its camera only captures after an explicit
camera.start_monitor RPC, which the Moonraker
websocket executes unauthenticated but only
answers over MQTT - so the call is fire and
forget.
Start the camera when the camera view is
shown and renew every 300 s: the printer
retires the capture task at ~362 s and
stop_monitor is accepted but ineffective,
so teardown is simply to stop renewing.
Frames land in monitor.jpg as still JPEGs
(~2 fps at interval 0), so the webview loads
a local HTML wrapper that repolls with a
cache buster.
The monitor panel showed wrong or missing
data for Moonraker printers, and its
controls did nothing.
Push payload now carries layer number and
total layers. Remaining time replaces the
wrong total_duration - print_duration
formula. The chamber light toggle maps to
Klipper SET_PIN / SET_LED, and pause,
resume and stop post to
/printer/print/{action}. Task thumbnails
resolve via /server/files/thumbnails onto
a new MachineObject thumbnail url.
Filament sync switches to pull mode so the
agent is queried on demand.
Not compiled or run.
When a print fails, DeviceErrorDialog now fetches the printer's captured camera
frame of the failure and shows it in place of the generic HMS illustration,
falling back to the local image and a drawn placeholder on older plugins or errors.
- Agent: add get_hms_snapshot through NetworkAgent / IPrinterAgent (BBL calls the
bound plugin symbol; other agents no-op, so old plugins degrade gracefully).
- DeviceManager: parse and clear m_print_error_img_id from the print-error message.
- Dialog: tiered cloud/local/placeholder image reusing the single image widget,
with a liveness-guarded async callback decoded on the UI thread.
The Filament Track Switch (H2-series accessory, product code O2L-FTS) feeds
every AMS to both extruders through a two-track switch. Port full support
across the device layer, project config, and GUI.
Device / config:
- Model the switch-aware AMS binding (the set of extruders an AMS can feed
and which input track A/B feeds it), switch readiness, the O2L-FTS firmware
module, and the fun2 capability bit for checking a slice against installed
hardware.
- Register has_filament_switcher and enable_filament_dynamic_map as project
config that persists with the project and restores from a saved 3mf, and
force both back to false on every project/printer/CLI load path. Live
device sync is the only thing that sets them true.
GUI:
- Sidebar sync activates the switch from live device state, attributes each
AMS to the extruder its input track feeds, shows a floating status icon
(ready / not-calibrated), and surfaces a one-time tip / not-calibrated
warning.
- Send dialog gains a non-blocking slice-vs-hardware mismatch warning and a
blocking error when a slice needs dynamic nozzle mapping but the switch is
missing or not set up.
- AMS load/unload guards, AMS-view routing glyph + un-calibrated banner +
hidden external-spool road, and mapping-popup external-spool lockout.
- Filament pickers collapse the per-extruder split into a single deduplicated
"AMS filaments" group with a smart-assign toggle when the switch is ready.
- Firmware-upgrade panel lists the O2L-FTS accessory and its version.
- Device-provided filament-change steps (ams.cfs) drive the change-step
display when firmware sends them, including the three switch steps.
- "Load current filament" asks which extruder to feed via a
FeedDirectionDialog when the switch is calibrated.
Inert without the accessory: every path is gated on the switch being
installed (MQTT aux bit 29, default off) or ready, both project flags default
false, and the per-extruder AMS attribution is byte-identical, so AMS state,
the send/load UI, and sliced g-code are unchanged for every printer that does
not report a Filament Track Switch.
Multi-nozzle sync widget, AMS rack-nozzle mapping popup, calibration rework, send-dialog nozzle mapping and extruder-count UI. Includes the fix to persist the AMS sync badge on filament cards (H2C/A2L and direct-sync printers).
* Clean up code
* Filament mapping select ext slot automatically when no AMS filament inserted (OrcaSlicer/OrcaSlicer#13103)
* Show warning if external filament type does not match the one in sliced file