Fix wrong number thickness in PA Line

This commit is contained in:
thewildmage
2023-07-13 20:50:10 -06:00
parent e99b0100a0
commit 606ee7ec4b

View File

@@ -280,6 +280,13 @@ std::string CalibPressureAdvanceLine::print_pa_lines(double start_x, double star
filament_diameter,
print_flow_ratio
);
const double number_e_per_mm = CalibPressureAdvance::e_per_mm(
m_number_line_width,
m_height_layer,
m_nozzle_diameter,
filament_diameter,
print_flow_ratio
);
const double fast = CalibPressureAdvance::speed_adjust(m_fast_speed);
const double slow = CalibPressureAdvance::speed_adjust(m_slow_speed);
@@ -318,9 +325,9 @@ std::string CalibPressureAdvanceLine::print_pa_lines(double start_x, double star
start_x + m_length_short + m_length_long + m_length_short + 3,
y_pos + i * m_space_y + m_space_y / 2,
start_pa + i * step_pa,
DrawDigitMode::Left_To_Right,
m_draw_digit_mode,
m_number_line_width,
m_height_layer,
number_e_per_mm,
writer
);
}