"device_error": {
"en": [
{
"ecode": "03008064",
"intro": "The chamber temperature is too high. Please open the top cover and front door to cool down. (Open door detection for this print job will be set to \"Notification\" level)"
},
{
"ecode": "0C008018",
"intro": "The foreign object detection function is not active; please check for any foreign objects on the platform."
},
{
"ecode": "0C008017",
"intro": "Foreign objects detected on the platform; please clean them up on time."
},
{
"ecode": "05008077",
"intro": "The visual marker was not detected. Please ensure the paper is properly placed."
},
{
"ecode": "05008078",
"intro": "Current material does not match the sliced file settings. Please load the correct material and ensure the QR code on the material is not damaged or dirty."
},
{
"ecode": "07FE8010",
"intro": "Check if the left external filament spool or filament is stuck. After troubleshooting, click the 'Retry' button."
},
{
"ecode": "0500403F",
"intro": "Failed to download print job; please check your network connection."
},
{
"ecode": "18FE8010",
"intro": "Check if the left external filament spool or filament is stuck. After troubleshooting, click the 'Retry' button."
},
{
"ecode": "05008073",
"intro": "The heatbed limit block is obstructed or dirty. Please expose the limit block, otherwise it will falsely report bed leveling detection failure."
},
{
"ecode": "18FF8010",
"intro": "Check if the right external filament spool or filament is stuck. After troubleshooting, click the 'Retry' button."
},
{
"ecode": "07FF8010",
"intro": "Check if the right external filament spool or filament is stuck. After troubleshooting, click the 'Retry' button."
},
{
"ecode": "03008042",
"intro": "Task paused because the door, top cover, or side window is open."
},
{
"ecode": "05008074",
"intro": "The laser platform is offset. Please ensure that the four corners of the platform are aligned with the heatbed."
},
{
"ecode": "05008063",
"intro": "The platform is not detected during calibration; please make sure the laser plate is properly placed."
},
{
"ecode": "0C008040",
"intro": "AI detected air-printing defect. Please check the hotend extrusion status. Refer to assistant for solutions."
},
{
"ecode": "05008059",
"intro": "The cutting protection base is offset. Please ensure that the four corners of the base plate are aligned with the heatbed."
},
{
"ecode": "05008056",
"intro": "The current cutting protection base type is incorrect. Please place a cutting protection steel plate to perform the knife cutting calibration."
},
{
"ecode": "05008064",
"intro": "The platform type is unknown during calibration; please replace it with the correct one and check if the BirdsEye camera is obstructed."
},
{
"ecode": "05008066",
"intro": "The current cutting protection base type does not match the settings in slicer. Please place the cutting protection steel plate."
},
{
"ecode": "0500806C",
"intro": "Unknown cutting protection base type. Please replace it with the correct cutting protection base and check if the live camera is obstructed."
},
{
"ecode": "05008071",
"intro": "No cutting protection steel plate detected. Please confirm that it has been correctly placed."
},
{
"ecode": "05004065",
"intro": "The platform type does not match, which may result in inaccurate height measurement data. Please place the laser platform correctly, then re-measure the height in Bambu Suite and initiate the task."
},
{
"ecode": "0C00803F",
"intro": "AI detected nozzle clumping. Please check the nozzle condition. Refer to assistant for solutions."
},
{
"ecode": "05004075",
"intro": "No laser platform detected, which may result in inaccurate height measurement. Please place the laser platform correctly, then re-measure the height in Bambu Suite and restart the task."
},
{
"ecode": "05004076",
"intro": "Unknown platform during operation, which may result in inaccurate height measurement data. Please place the laser platform correctly, and check if the BirdsEye camera is obstructed, then re-measure the height in Bambu Suite and restart the task."
},
{
"ecode": "0300804A",
"intro": "Emergency stop button improperly installed. Please reinstall according to instructions before proceeding."
},
{
"ecode": "03008051",
"intro": "The cutting module has dropped or the cutting module cable is disconnected; Please check."
},
{
"ecode": "0500403D",
"intro": "The toolhead module is not set up. Please set it up before initiating the task."
},
{
"ecode": "07FE8011",
"intro": "The external filament connected to the left extruder has run out; please load a new filament."
},
{
"ecode": "03004067",
"intro": "Calibration result is over the threhold."
},
{
"ecode": "07028016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18FF8024",
"intro": "Extruder position calibration failed; please refer to the assistant. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07068011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "05024005",
"intro": "The AMS has not been calibrated yet, so printing cannot be initiated."
},
{
"ecode": "18008011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18048003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18028011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07FEC008",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "03008061",
"intro": "The mode of Adaptive Airflow System failed to activate; check the air door condition."
},
{
"ecode": "05008053",
"intro": "The left and right nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "07028013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07068003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07068006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "18028005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18078003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18028006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18FE8013",
"intro": "Timeout purging old filament of the left extruder: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FE8003",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)"
},
{
"ecode": "07FE8021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "05004070",
"intro": "The device has been connected to the laser or cutter module and cannot initiate a 3D printing task."
},
{
"ecode": "07068007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07078012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07048006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "07048010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18FF8020",
"intro": "Extruder change failed; please refer to the assistant, after troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FEC006",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "18028007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18068011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18018013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18028010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "05008061",
"intro": "No print plate detected; please make sure it is placed correctly."
},
{
"ecode": "07008016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18FEC008",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "07048011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07068004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18038013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18804069",
"intro": "An error occurred during AMS-HT A drying. Please go to Assistant for more details."
},
{
"ecode": "18824069",
"intro": "An error occurred during AMS-HT C drying. Please go to Assistant for more details."
},
{
"ecode": "07048007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07038021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07038016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18FE8004",
"intro": "Failed to pull back the filament from the left extruder. Please check whether the filament is stuck inside the left extruder. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FF8001",
"intro": "Failed to cut the filament of the right extruder. Please check the cutter. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18078004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18068010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18038006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18FF8005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18068005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18008017",
"intro": "AMS-HT A is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "18814069",
"intro": "An error occurred during AMS-HT B drying. Please go to Assistant for more details."
},
{
"ecode": "07028017",
"intro": "AMS C is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "0C008002",
"intro": "Spaghetti failure was detected."
},
{
"ecode": "07FEC00A",
"intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, click \"Done\"; if not, please push the filament forward slightly and then click \"Retry\"."
},
{
"ecode": "18058010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18FE8012",
"intro": "Failed to get mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18068007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FF8004",
"intro": "Failed to pull back the filament from the right extruder. Please check whether the filament is stuck inside the left extruder. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18048010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "07028021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07008021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18048016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18078011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18058006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18FF8011",
"intro": "The external filament connected to the right extruder has run out; please load a new filament."
},
{
"ecode": "07048004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18FFC008",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "0C004027",
"intro": "The Live View Camera calibration failed. Please refer to the assistant for details and recalibrate the camera after processing."
},
{
"ecode": "07068021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07014069",
"intro": "An error occurred during AMS B drying. Please go to Assistant for more details."
},
{
"ecode": "18FE8006",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "07018021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "03008052",
"intro": "Cutter zero return error: please return to zero again."
},
{
"ecode": "05FF806A",
"intro": "The right hotend can't be identified, possibly due non-official hotend or blocked live view camera. please set hotend type before next print."
},
{
"ecode": "18018021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07078010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18068003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07008007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "05024006",
"intro": "Unknown module detected, please try updating the firmware to the latest version."
},
{
"ecode": "07FFC003",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "07004069",
"intro": "An error occurred during AMS A drying. Please go to Assistant for more details."
},
{
"ecode": "18864069",
"intro": "An error occurred during AMS-HT G drying. Please go to Assistant for more details."
},
{
"ecode": "07048016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18078006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18028012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18078007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07078021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18FF8003",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)"
},
{
"ecode": "18058016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "05004040",
"intro": "Due to power limitations, the AMS is not allowed to use the device's power for drying during printing. Should the drying be stopped?"
},
{
"ecode": "18FE8007",
"intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, click \"Done\"; if it is not, please push the filament forward slightly, and then click \"Retry\"."
},
{
"ecode": "18068012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18028017",
"intro": "AMS-HT C is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "07038017",
"intro": "AMS D is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "18FE8001",
"intro": "Failed to cut the filament of the left extruder. Please check the cutter. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18008021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07068005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07058005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07078004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18844069",
"intro": "An error occurred during AMS-HT E drying. Please go to Assistant for more details."
},
{
"ecode": "07048013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18068004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07058011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "1001C001",
"intro": "Timelapse is not supported because Spiral vase mode is enabled in slicing presets."
},
{
"ecode": "07FF8021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "0C008015",
"intro": "Objects detected on the platform; please clean them up in a timely manner."
},
{
"ecode": "05008060",
"intro": "The current module does not meet make requirements. Please replace the module as per the on-screen instructions."
},
{
"ecode": "0C004025",
"intro": "The birdseye camera is dirty; please clean it and restart the process."
},
{
"ecode": "07FFC008",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "05024002",
"intro": "The printer does not have motion precision enhancement calibration data; the motion precision enhancement cannot be turned on."
},
{
"ecode": "18FF8007",
"intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, click \"Done\"; if it is not, please push the filament forward slightly, and then click \"Retry\"."
},
{
"ecode": "07048012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18048012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18038004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07058003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18008010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18048007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FE8002",
"intro": "The cutter of the left extruder is stuck. Please pull out the cutter handle and click the \"Retry\" button."
},
{
"ecode": "0300400C",
"intro": "The task was canceled."
},
{
"ecode": "07FE8020",
"intro": "Extruder change failed; please refer to the assistant, after troubleshooting, click the \"Retry\" button."
},
{
"ecode": "05FE8053",
"intro": "The left nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "0500806E",
"intro": "Foreign objects detected on heatbed; please check and clean the heatbed."
},
{
"ecode": "07FF8024",
"intro": "Extruder position calibration failed; please refer to the assistant. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18038010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18018010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18078021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18FE8020",
"intro": "Extruder change failed; please refer to the assistant, after troubleshooting, click the \"Retry\" button."
},
{
"ecode": "05008055",
"intro": "Incorrect platform type. Please place the cutting platform for laser calibration."
},
{
"ecode": "05024003",
"intro": "The printer is currently printing and the motion accuracy enhancement feature cannot be turned on or off."
},
{
"ecode": "18038016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "07078007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18028003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07008017",
"intro": "AMS A is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "18058005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18008006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18038007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "0500805C",
"intro": "The grip cutting mat type does not match; please place a lightgrip cutting mat."
},
{
"ecode": "0500805E",
"intro": "Cutting module Serial Number error: unable to calibrate or make project."
},
{
"ecode": "07078013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18068016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18FF8012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18038011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18008012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07078006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "18028013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18854069",
"intro": "An error occurred during AMS-HT F drying. Please go to Assistant for more details."
},
{
"ecode": "05008072",
"intro": "Liveview camera is blocked"
},
{
"ecode": "18018017",
"intro": "AMS-HT B is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "18048011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18068006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18008005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18FEC009",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "18048021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07048005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07078011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18FFC009",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "07018017",
"intro": "AMS B is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "18008004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18FF8021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07058010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18078016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18008003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "0500405D",
"intro": "Laser module Serial Number error: unable to calibrate or make project."
},
{
"ecode": "05FE806A",
"intro": "The left hotend can't be identified, possibly due non-official hotend or blocked live view camera. please set hotend type before next print."
},
{
"ecode": "0C00403E",
"intro": "The high-precision nozzle offset calibration has failed, possibly due to a damaged pattern or the similarity of the colors of the two selected filaments. Please clear the printed pattern and replace the filaments with higher color contrast before re-calibrating."
},
{
"ecode": "07FE8024",
"intro": "Extruder position calibration failed; please refer to the assistant. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07068012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "03004013",
"intro": "Printing cannot be initiated while AMS is drying."
},
{
"ecode": "18FE8021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18058021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18FE8024",
"intro": "Extruder position calibration failed; please refer to the assistant. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18FEC00A",
"intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, click \"Done\"; if not, please push the filament forward slightly and then click \"Retry\"."
},
{
"ecode": "05008051",
"intro": "Detected build plate is not the same as the Gcode file. Please adjust slicer settings or use the correct plate."
},
{
"ecode": "0500402F",
"intro": "USB flash drive sector data is damaged; please format it. If it still cannot be recognized, please replace the USB flash drive."
},
{
"ecode": "07008013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18028021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07058013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18018005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18078013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18058012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18018004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18078010",
"intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "18FEC003",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "18048013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07FEC003",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "0C008016",
"intro": "Foreign object detection not effective; please pay attention to whether there are objects on the platform."
},
{
"ecode": "0C00402A",
"intro": "The visual marker was not detected. Please re-paste the paper in the correct position."
},
{
"ecode": "07018016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "0500806F",
"intro": "The grip cutting mat type does not match; please place a strong grip cutting mat."
},
{
"ecode": "07058007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07058021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18038017",
"intro": "AMS-HT D is drying. Please stop drying process before loading/unloading material."
},
{
"ecode": "07078016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18048005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18028016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18038021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "07068010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "07058012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18008007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18058013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07058004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07058006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "18FF8013",
"intro": "Timeout purging old filament of the right extruder: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18018012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18018007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18078005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "0500806A",
"intro": "The left and right hotend can't be identified, possibly due non-official hotend or blocked live view camera. please set hotend type before next print."
},
{
"ecode": "05FF8053",
"intro": "The right nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "18078012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "18FFC003",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)"
},
{
"ecode": "18FF8002",
"intro": "The cutter of the right extruder is stuck. Please pull out the cutter handle and click the \"Retry\" button."
},
{
"ecode": "07078003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07068016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "18008013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18874069",
"intro": "An error occurred during AMS-HT H drying. Please go to Assistant for more details."
},
{
"ecode": "18FF8006",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "18058011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18028004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "03004000",
"intro": "Z axis homing failed, task has been stopped."
},
{
"ecode": "0500C010",
"intro": "USB flash drive read-write exception; please reinsert or replace it."
},
{
"ecode": "18058004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18048006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18FE8005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18038005",
"intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07078005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "18058007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18038003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07058016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "07034069",
"intro": "An error occurred during AMS D drying. Please go to Assistant for more details."
},
{
"ecode": "0C004026",
"intro": "The Live View Camera initialization failed; please ensure the camera is properly installed."
},
{
"ecode": "18068013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07048003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18068021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18FE8011",
"intro": "The external filament connected to the left extruder has run out; please load a new filament."
},
{
"ecode": "07068013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18038012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07FF8020",
"intro": "Extruder change failed; please refer to the assistant, after troubleshooting, click the \"Retry\" button."
},
{
"ecode": "18018011",
"intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "18008016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "07024069",
"intro": "An error occurred during AMS C drying. Please go to Assistant for more details."
},
{
"ecode": "18058003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18018003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "18834069",
"intro": "An error occurred during AMS-HT D drying. Please go to Assistant for more details."
},
{
"ecode": "07FF8011",
"intro": "The external filament connected to the right extruder has run out; please load a new filament."
},
{
"ecode": "18048004",
"intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "18018006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected."
},
{
"ecode": "18018016",
"intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please click \"Retry\" button."
},
{
"ecode": "07048021",
"intro": "AMS setup failed; please refer to the assistant."
},
{
"ecode": "18FFC006",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "03008016",
"intro": "The nozzle is clogged with filament. Please cancel this print and clean the nozzle or tap the \"Resume\" button to resume the print job."
},
{
"ecode": "05004008",
"intro": "Starting printing failed; please power cycle the printer and resend the print job."
},
{
"ecode": "05004018",
"intro": "Binding configuration information parsing failed; please try again."
},
{
"ecode": "03008049",
"intro": "The current plate is invalid."
},
{
"ecode": "07FE8004",
"intro": "Failed to pull back the filament from the left extruder. Please check whether the filament is stuck inside the left extruder. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07FF8003",
"intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)"
},
{
"ecode": "0500400A",
"intro": "The file name is not supported. Please rename and restart the print job."
},
{
"ecode": "0500400B",
"intro": "There was a problem downloading a file. Please check your network connection and resend the print job."
},
{
"ecode": "0500400D",
"intro": "Please run a self-test and restart the print job."
},
{
"ecode": "0500402C",
"intro": "Failed to obtain IP address, which may be caused by wireless interference resulting in data transmission failure or the DHCP address pool of the router being full. Please move the printer closer to the router and try again. If the issue persists, please check router settings to see whether the IP addresses have been exhausted."
},
{
"ecode": "05014033",
"intro": "Your APP region does not match with your printer; please download the APP in the corresponding region and register your account again."
},
{
"ecode": "07FE8003",
"intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)"
},
{
"ecode": "07FE8007",
"intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, click \"Done\"; if it is not, please push the filament forward slightly, and then click \"Retry\"."
},
{
"ecode": "0300801C",
"intro": "The extrusion resistance is abnormal. The extruder may be clogged, please refer to the assistant, after trouble shooting, you can tap the \"Resume\" button to resume the print job."
},
{
"ecode": "07FE8002",
"intro": "The cutter of the left extruder is stuck. Please pull out the cutter handle and click the \"Retry\" button."
},
{
"ecode": "07FF8004",
"intro": "Failed to pull back the filament from the right extruder. Please check whether the filament is stuck inside the left extruder. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07FF8007",
"intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, click \"Done\"; if it is not, please push the filament forward slightly, and then click \"Retry\"."
},
{
"ecode": "03008014",
"intro": "The nozzle is covered with filament, or the build plate is installed incorrectly. Please cancel this print and clean the nozzle or adjust the build plate according to the actual status. You can also tap the \"Resume\" button to resume the print job."
},
{
"ecode": "05004002",
"intro": "Unsupported print file path or name. Please resend the print job."
},
{
"ecode": "0500402D",
"intro": "System exception"
},
{
"ecode": "0501401A",
"intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before trying again."
},
{
"ecode": "05014039",
"intro": "Device login has expired; please try to bind again."
},
{
"ecode": "03008046",
"intro": "Foreign object detect timeout: please restart the printer."
},
{
"ecode": "03008047",
"intro": "Quick-release lever detection time out: please restart the printer."
},
{
"ecode": "03008062",
"intro": "The chamber temperature is too high. It may be due to high environmental temperature."
},
{
"ecode": "0500805B",
"intro": "The cutting mat type is unknown; please replace it with the correct cutting mat and check if the Live View camera is obstructed."
},
{
"ecode": "0500805A",
"intro": "Please place the cutting mat."
},
{
"ecode": "03008001",
"intro": "Printing paused due to the pause command added in the printing file."
},
{
"ecode": "03008008",
"intro": "Nozzle temperature malfunction"
},
{
"ecode": "03008009",
"intro": "Heatbed temperature malfunction"
},
{
"ecode": "0300800C",
"intro": "Skipped step detected: auto-recover complete; please resume print and check if there are any layer shift problems."
},
{
"ecode": "03008017",
"intro": "Foreign objects detected on heatbed. Please check and clean the heatbed. Then, tap the \"Resume\" button to resume the print job."
},
{
"ecode": "05004006",
"intro": "There is not enough free storage space for the print job. Restoring to factory settings can free up available space."
},
{
"ecode": "0500401A",
"intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before trying again."
},
{
"ecode": "05014018",
"intro": "Binding configuration information parsing failed; please try again."
},
{
"ecode": "03008041",
"intro": "Laser Platform detection timeout"
},
{
"ecode": "03008045",
"intro": "Material detection timeout: please restart the printer."
},
{
"ecode": "0300801A",
"intro": "The extruder is not extruding normally; please refer to the assistant. After trouble shooting, if the defects are acceptable, please tap the \"Resume\" button to resume the print job."
},
{
"ecode": "07FF8002",
"intro": "The cutter of the right extruder is stuck. Please pull out the cutter handle and click the \"Retry\" button."
},
{
"ecode": "0300400F",
"intro": "The power supply voltage does not match the printer."
},
{
"ecode": "07018013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07038013",
"intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "05024004",
"intro": "Some features are not supported by the current device. Please check the Studio feature settings or update the firmware to the latest version."
},
{
"ecode": "0500806D",
"intro": "Material not detected. Please confirm placement and continue."
},
{
"ecode": "18028023",
"intro": "The cooling process after drying has failed in AMS-HT C."
},
{
"ecode": "18008023",
"intro": "The cooling process after drying has failed in AMS-HT A."
},
{
"ecode": "18078023",
"intro": "The cooling process after drying has failed in AMS-HT H."
},
{
"ecode": "0C004022",
"intro": "The setup of BirdsEye Camera failed. Please check if the laser module is working properly."
},
{
"ecode": "0C004021",
"intro": "The setup of BirdsEye Camera failed. Please check if the camera is installed correctly."
},
{
"ecode": "0C004020",
"intro": "The setup of BirdsEye Camera failed. Please clear all objects and remove the mat. Make sure the marker is not obstructed."
},
{
"ecode": "18038023",
"intro": "The cooling process after drying has failed in AMS-HT D."
},
{
"ecode": "18058023",
"intro": "The cooling process after drying has failed in AMS-HT F."
},
{
"ecode": "18068023",
"intro": "The cooling process after drying has failed in AMS-HT G."
},
{
"ecode": "18048023",
"intro": "The cooling process after drying has failed in AMS-HT E."
},
{
"ecode": "07078023",
"intro": "The cooling process after drying has failed in AMS H."
},
{
"ecode": "07068023",
"intro": "The cooling process after drying has failed in AMS G."
},
{
"ecode": "07058023",
"intro": "The cooling process after drying has failed in AMS F."
},
{
"ecode": "07048023",
"intro": "The cooling process after drying has failed in AMS E."
},
{
"ecode": "18018023",
"intro": "The cooling process after drying has failed in AMS-HT B."
},
{
"ecode": "05008062",
"intro": "The print plate type is unknown; please replace it with the correct plate and check if the live view camera is obstructed."
},
{
"ecode": "05008069",
"intro": "The left and right hotend can't be identified, possibly due to the blocked live view camera or the damaged nozzle marker. Please manually set the hotend type."
},
{
"ecode": "05FE8069",
"intro": "The left hotend can't be identified, possibly due to the blocked live view camera or the damaged nozzle marker. Please manually set the hotend type."
},
{
"ecode": "05FF8069",
"intro": "The right hotend can't be identified, possibly due to the blocked live view camera or the damaged nozzle marker. Please manually set the hotend type."
},
{
"ecode": "0300801D",
"intro": "The extruder servo motor position sensor is malfunctioning. Please power off the printer first and check if the connection cable is loose."
},
{
"ecode": "07008023",
"intro": "The cooling process after drying has failed in AMS A."
},
{
"ecode": "07028023",
"intro": "The cooling process after drying has failed in AMS C."
},
{
"ecode": "07038023",
"intro": "The cooling process after drying has failed in AMS D."
},
{
"ecode": "07018023",
"intro": "The cooling process after drying has failed in AMS B."
},
{
"ecode": "0500806B",
"intro": "Quick-release Lever is not locked. Please press it down to secure it."
},
{
"ecode": "03004020",
"intro": "The nozzle presence detection failed. The nozzle may not be mounted on the extruder or the sensor may be damaged."
},
{
"ecode": "07038006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "07018006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "07028006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "07028003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07FFC006",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "07FF8013",
"intro": "Timeout purging old filament of the right extruder: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07038004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07018003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07FF8001",
"intro": "Failed to cut the filament of the right extruder. Please check the cutter. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07038003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "0500402E",
"intro": "System does not support the file system currently used by the USB flash drive. Please replace or format the USB flash drive to FAT32 format."
},
{
"ecode": "07FFC009",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "07FF8006",
"intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther."
},
{
"ecode": "07028004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "0C00403D",
"intro": "The vision encoder plate was not detected. Please confirm it is correctly positioned on the heatbed."
},
{
"ecode": "0C004024",
"intro": "The birdseye camera is installed offset. Please refer to the guide to reinstall it."
},
{
"ecode": "03008044",
"intro": "Fire was detected inside the chamber."
},
{
"ecode": "0C00C004",
"intro": "Possible spaghetti failure was detected."
},
{
"ecode": "05004043",
"intro": "Due to power limitations, only one AMS is allowed to use the device's power for drying."
},
{
"ecode": "05004052",
"intro": "Error detected on the hot end."
},
{
"ecode": "05004050",
"intro": "Error detected on the print board."
},
{
"ecode": "03004068",
"intro": "Step loss occurred during the motion accuracy enhancement process. Please try again."
},
{
"ecode": "03004011",
"intro": "Calibration of dynamic flux compensation failed."
},
{
"ecode": "05004041",
"intro": "Due to power limitations, only one AMS is allowed to use the device's power for drying during printing. Should the drying be stopped?"
},
{
"ecode": "05004054",
"intro": "Error detected on the mat."
},
{
"ecode": "0500403E",
"intro": "The current tool head does not support initialization."
},
{
"ecode": "03004066",
"intro": "Calibration of motion precision failed."
},
{
"ecode": "0C00C006",
"intro": "Purged filament may have piled up in the waste chute."
},
{
"ecode": "05004042",
"intro": "The AMS is currently being used for printing and cannot initiate drying."
},
{
"ecode": "07FE8001",
"intro": "Failed to cut the filament of the left extruder. Please check the cutter. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "03008063",
"intro": "The chamber temperature is too high. Please open the top cover and front door to cool down."
},
{
"ecode": "03008043",
"intro": "The laser module is abnormal."
},
{
"ecode": "03008065",
"intro": "The temperature of the MC module is too high. Please check the Wiki for specific reasons."
},
{
"ecode": "07FEC006",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "07FE8005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "0C00800B",
"intro": "The heatbed marker was not detected. Please clear all objects and remove the mat. Make sure the marker is not obstructed."
},
{
"ecode": "07FE8012",
"intro": "Failed to get mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07FEC009",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "0C004029",
"intro": "Material not detected. Please confirm placement and continue."
},
{
"ecode": "05014038",
"intro": "The regional settings do not match the printer, please check the printer's regional settings."
},
{
"ecode": "07FE8013",
"intro": "Timeout purging old filament of the left extruder: Please check if the filament is stuck or the extruder is clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "0C008005",
"intro": "Purged filament has piled up in the waste chute, which may cause a tool head collision."
},
{
"ecode": "0300801E",
"intro": "The extrusion motor is overloaded, please check if the extruder is clogged or the filament is stuck in the tool head."
},
{
"ecode": "0C008033",
"intro": "Quick-release Lever is not locked. Please push it down to secure."
},
{
"ecode": "07FE8006",
"intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther."
},
{
"ecode": "03004010",
"intro": "Nozzle offset calibration failed."
},
{
"ecode": "0C008009",
"intro": "Build plate localization marker was not found."
},
{
"ecode": "1000C001",
"intro": "High bed temperature may lead to filament clogging in the nozzle. You may open the chamber door."
},
{
"ecode": "1000C002",
"intro": "Printing CF material with stainless steel may cause nozzle damage."
},
{
"ecode": "1000C003",
"intro": "Enabling traditional timelapse might lead to defects. Please enable it as needed?"
},
{
"ecode": "1001C002",
"intro": "Timelapse is not supported because Print sequence is set to \"By object\"."
},
{
"ecode": "07038005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07038007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07038010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "07038011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07038012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07FF8005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07FF8012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07028007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07028010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "07028011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07028012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07028005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07018004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07018005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07018007",
"intro": "Failed to extrude the filament. Please check if the extruder clogged. After troubleshooting, click the \"Retry\" button."
},
{
"ecode": "07018010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "07018011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07018012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07008011",
"intro": "AMS filament ran out. Please insert a new filament into the same AMS slot."
},
{
"ecode": "07008012",
"intro": "Failed to get AMS mapping table; please click \"Retry\" to continue."
},
{
"ecode": "07008003",
"intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder."
},
{
"ecode": "07008004",
"intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path."
},
{
"ecode": "07008005",
"intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear."
},
{
"ecode": "07008006",
"intro": "Unable to feed filament into the extruder. This could be due to entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected."
},
{
"ecode": "07008010",
"intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool."
},
{
"ecode": "0501401B",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0501401C",
"intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0501401D",
"intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "0501401E",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0501401F",
"intro": "Authorization timed out. Please make sure that your phone or PC has access to the internet, and ensure that the Bambu Studio/Bambu Handy APP is running in the foreground during the binding operation."
},
{
"ecode": "05014020",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014021",
"intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "05014022",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014023",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014024",
"intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before you try again."
},
{
"ecode": "05014025",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014026",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014027",
"intro": "Cloud access failed; this may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "05014028",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014029",
"intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05014031",
"intro": "Device discovery binding is in progress, and the QR code cannot be displayed on the screen. You can wait for the binding to finish or abort the device discovery binding process in the APP/Studio and retry scanning the QR code on the screen for binding."
},
{
"ecode": "05014032",
"intro": "QR code binding is in progress, so device discovery binding cannot be performed. You can scan the QR code on the screen for binding or exit the QR code display page on screen and try device discovery binding."
},
{
"ecode": "05014034",
"intro": "The slicing progress has not been updated for a long time, and the printing task has exited. Please confirm the parameters and reinitiate printing."
},
{
"ecode": "05014035",
"intro": "The device is in the process of binding and cannot respond to new binding requests."
},
{
"ecode": "05024001",
"intro": "Current filament will be used in this print job. Settings cannot be changed."
},
{
"ecode": "05004001",
"intro": "Failed to connect to Bambu Cloud. Please check your network connection."
},
{
"ecode": "05004003",
"intro": "Printing stopped because the printer was unable to parse the file. Please resend your print job."
},
{
"ecode": "05004004",
"intro": "The printer can't receive new print jobs while printing. Resend after the current print finishes."
},
{
"ecode": "05004005",
"intro": "Print jobs are not allowed to be sent while updating firmware."
},
{
"ecode": "05004007",
"intro": "Print jobs are not allowed to be sent while force updating or when repair updating is required."
},
{
"ecode": "05004009",
"intro": "Print jobs are not allowed to be sent while updating logs."
},
{
"ecode": "0500400E",
"intro": "Printing was cancelled."
},
{
"ecode": "05004014",
"intro": "Slicing for the print job failed. Please check your settings and restart the print job."
},
{
"ecode": "05004017",
"intro": "Binding failed. Please retry or restart the printer and retry."
},
{
"ecode": "05004019",
"intro": "The printer has already been bound. Please unbind it and try again."
},
{
"ecode": "0500401B",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0500401C",
"intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0500401D",
"intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "0500401E",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0500401F",
"intro": "Authorization timed out. Please make sure that your phone or PC has access to the internet, and ensure that the Bambu Studio/Bambu Handy APP is running in the foreground during the binding operation."
},
{
"ecode": "05004020",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004021",
"intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "05004022",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004023",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004024",
"intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before you try again."
},
{
"ecode": "05004025",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004026",
"intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004027",
"intro": "Cloud access failed; this may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again."
},
{
"ecode": "05004028",
"intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "05004029",
"intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer service."
},
{
"ecode": "0500402A",
"intro": "Failed to connect to the router, which may be caused by wireless interference or being too far away from the router. Please try again or move the printer closer to the router and try again."
},
{
"ecode": "0500402B",
"intro": "Router connection failed due to incorrect password. Please check the password and try again."
},
{
"ecode": "05004037",
"intro": "Your sliced file is not compatible with current printer model. This file can't be printed on this printer."
},
{
"ecode": "05004038",
"intro": "The nozzle diameter in sliced file is not consistent with the current nozzle setting. This file can't be printed."
},
{
"ecode": "05008013",
"intro": "The print file is not available. Please check to see if the storage media has been removed."
},
{
"ecode": "05008030",
"intro": ""
},
{
"ecode": "05008036",
"intro": "Your sliced file is not consistent with the current printer model. Continue?"
},
{
"ecode": "0500C011",
"intro": ""
},
{
"ecode": "05014017",
"intro": "Binding failed. Please retry or restart the printer and retry."
},
{
"ecode": "05014019",
"intro": "The printer has already been bound. Please unbind it and try again."
},
{
"ecode": "03004001",
"intro": "The printer timed out waiting for the nozzle to cool down before homing."
},
{
"ecode": "03004002",
"intro": "Printing Stopped because Auto Bed Leveling failed."
},
{
"ecode": "03004005",
"intro": "The hotend cooling fan speed is abnormal."
},
{
"ecode": "03004006",
"intro": "The nozzle is clogged."
},
{
"ecode": "03004008",
"intro": "The AMS failed to change filament."
},
{
"ecode": "03004009",
"intro": "Homing XY axis failed."
},
{
"ecode": "0300400A",
"intro": "Mechanical resonance frequency identification failed."
},
{
"ecode": "0300400B",
"intro": "Internal communication exception."
},
{
"ecode": "0300400D",
"intro": "Resume failed after power loss."
},
{
"ecode": "0300400E",
"intro": "The motor self-check failed."
},
{
"ecode": "03008000",
"intro": "Printing was paused for unknown reason. You can tap \"Resume\" to resume the print job."
},
{
"ecode": "03008003",
"intro": "Spaghetti defects were detected by the AI Print Monitoring. Please check the quality of the printed model before continuing your print."
},
{
"ecode": "03008007",
"intro": "There was an unfinished print job when the printer lost power. If the model is still adhered to the build plate, you can try resuming the print job."
},
{
"ecode": "0300800B",
"intro": "The cutter is stuck. Please make sure the cutter handle is out, and check the filament sensor cable connection."
},
{
"ecode": "0300800D",
"intro": "Some objects have fallen down, or the extruder is not extruding normally. If the defects are acceptable, click \"Resume\" button to resume the print job."
},
{
"ecode": "0300800E",
"intro": "The print file is not available. Please check to see if the storage media has been removed."
},
{
"ecode": "0300800F",
"intro": "The door seems to be open, so printing was paused."
},
{
"ecode": "03008010",
"intro": "The hotend cooling fan speed is abnormal."
},
{
"ecode": "03008013",
"intro": "Printing was paused by the user. You can select \"Resume\" to continue printing."
},
{
"ecode": "03008018",
"intro": "Chamber temperature malfunction."
},
{
"ecode": "03008019",
"intro": "No build plate is placed."
}
],
"ver": 202501031057
},
"device_hms": {
"en": [
{
"ecode": "03009E0000030001",
"intro": "Open door detection for this print job will be set to \"Notification\" level."
},
{
"ecode": "0500040000010052",
"intro": "Safety key is not inserted; please install correctly as guided in Wiki."
},
{
"ecode": "0500040000010051",
"intro": "Emergency stop button is not installed; please install correctly as guided in Wiki."
},
{
"ecode": "0500050000010007",
"intro": "MQTT Command verification failed, please update Studio or Handy."
},
{
"ecode": "0500040000020037",
"intro": "The Cutting Module needs calibration to get the tool position. Please perform the mounting calibration before use. (about 1 minutes)"
},
{
"ecode": "0500040000020034",
"intro": "New Laser Module connected; for more precise cutting and engraving, please go to set up before use. (about 4 minutes)"
},
{
"ecode": "0500040000020036",
"intro": "New Cutting Module connected. To ensure more precise cutting, please set it up before use. (about 3 minutes)"
},
{
"ecode": "0500040000020035",
"intro": "The Laser Module needs calibration to get the focus position. Please perform mounting calibration before use. (about 2 minutes)"
},
{
"ecode": "0300C30000010002",
"intro": "Current sensor of Filter Switch Flap malfunction: this may be due to an open circuit or a hardware sampling circuit fault."
},
{
"ecode": "0300A10000010001",
"intro": "Chamber temperature is too high. Please open the top cover and front door to cool down, or lower the ambient temperature."
},
{
"ecode": "07FF800000020002",
"intro": "The position of right hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model."
},
{
"ecode": "18FF800000020002",
"intro": "The position of right hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model."
},
{
"ecode": "0500040000020050",
"intro": "Chassis side panel not installed."
},
{
"ecode": "0C00040000010012",
"intro": "Liveview Camera data link is abnormal."
},
{
"ecode": "0500050000010009",
"intro": "MQTT Command verification failedplease check the format or signature."
},
{
"ecode": "0500050000010008",
"intro": "MQTT Command verification failed, please install the latest certificate in Studio."
},
{
"ecode": "050005000001000B",
"intro": "MQTT Command verification failed, please update Studio."
},
{
"ecode": "050005000001000A",
"intro": "MQTT Command verification failed, please update Studio and printer firmware."
},
{
"ecode": "050005000001000C",
"intro": "MQTT Command verification failed, please update the printer firmware."
},
{
"ecode": "0500010000030005",
"intro": "The USB drive is in Read-Only mode. Video recording and Timelapse recording cannot be performed. Please refer to the Wiki for assistance."
},
{
"ecode": "0500040000020038",
"intro": "Please slide in cutting module and fasten the quick release lever. If already installed, the module might not be properly aligned. Please try reinstalling it."
},
{
"ecode": "0300260000010005",
"intro": "Z axis motor rotation is obstructed; please check if there are foreign objects stuck in the Z slider, or Z timing pulley."
},
{
"ecode": "0300250000010005",
"intro": "Z axis motor rotation is obstructed; please check if there are foreign objects stuck in the Z slider, or Z timing pulley."
},
{
"ecode": "0300260000010007",
"intro": "The frequency of the extrusion force sensor of the left extruder is too high. The sensor may be installed too close or the sensor may be loose."
},
{
"ecode": "0500010000020002",
"intro": "Live View camera is not connected. Please check the hardware and cable connections."
},
{
"ecode": "0500060000020034",
"intro": "Live View camera is not connected. Please check the hardware and cable connections."
},
{
"ecode": "0500060000020033",
"intro": "BirdsEye camera is not connected. Please check the hardware and cable connections."
},
{
"ecode": "0700230000020003",
"intro": "AMS A Slot 4's filament may be broken in AMS."
},
{
"ecode": "0700700000020046",
"intro": "AMS A Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0701100000010001",
"intro": "The AMS B slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0703620000020001",
"intro": "The AMS D Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0703700000020050",
"intro": "AMS D Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0700200000020007",
"intro": "AMS A Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0500010000020008",
"intro": "Ipcam memory too high; please contact R&D!"
},
{
"ecode": "0701200000020007",
"intro": "AMS B Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701700000020020",
"intro": "AMS B filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0700700000020011",
"intro": "AMS A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0C00040000010020",
"intro": "The visual marker on the heatbed is damaged, please contact after-sales."
},
{
"ecode": "0706220000020001",
"intro": "AMS G Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1804230000030002",
"intro": "AMS-HT E Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0706100000010003",
"intro": "The AMS G slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1804230000020001",
"intro": "AMS-HT E Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0707220000020003",
"intro": "AMS H Slot 3's filament may be broken in AMS."
},
{
"ecode": "0705200000020003",
"intro": "AMS F Slot 1's filament may be broken in AMS."
},
{
"ecode": "1806960000010003",
"intro": "AMS-HT G Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1800220000020005",
"intro": "AMS-HT A Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0705100000010003",
"intro": "The AMS F slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0704630000020001",
"intro": "The AMS E Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1802230000020005",
"intro": "AMS-HT C Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1803210000020005",
"intro": "AMS-HT D Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1800200000020001",
"intro": "AMS-HT A Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1801210000020003",
"intro": "AMS-HT B Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "0700210000020008",
"intro": "AMS A Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803210000030001",
"intro": "AMS-HT D Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806200000030002",
"intro": "AMS-HT G Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1801110000020002",
"intro": "The AMS-HT B slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802210000020004",
"intro": "AMS-HT C Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1803550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1804230000020005",
"intro": "AMS-HT E Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1806970000030001",
"intro": "AMS-HT G chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0704960000020002",
"intro": "AMS E Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1800600000020001",
"intro": "The AMS-HT A Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1805200000030002",
"intro": "AMS-HT F Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805220000020004",
"intro": "AMS-HT F Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1800110000020002",
"intro": "The AMS-HT A slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804200000020001",
"intro": "AMS-HT E Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1805210000020007",
"intro": "AMS-HT F Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802210000030002",
"intro": "AMS-HT C Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1804110000010003",
"intro": "The AMS-HT E slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806120000020002",
"intro": "The AMS-HT G slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1801700000020021",
"intro": "AMS-HT B Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "0C00010000020002",
"intro": "Toolhead camera is malfunctioning. If this issue occurs multiple times during printing, please contact customer service."
},
{
"ecode": "1805700000020010",
"intro": "AMS-HT F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0707700000020033",
"intro": "AMS H Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1804220000020009",
"intro": "Failed to extrude AMS-HT E Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1805700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "18FE200000020002",
"intro": "No filament was detected in the left extruder from the external spool; please load the new filament."
},
{
"ecode": "0704700000020060",
"intro": "AMS E Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0705700000020061",
"intro": "AMS F Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "0706700000020030",
"intro": "AMS G Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0C00010000010011",
"intro": "The Live View Camera calibration failed. Please check if the camera is installed correctly and ensure the camera image is clear and free of dirt. After these steps, please recalibrate."
},
{
"ecode": "1806200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "1807700000020033",
"intro": "AMS-HT H Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1805700000020032",
"intro": "AMS-HT F Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1805700000020042",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1800700000020045",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0705230000020009",
"intro": "Failed to extrude AMS F Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1804210000020009",
"intro": "Failed to extrude AMS-HT E Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "180422000002000A",
"intro": "Failed to adjust the filament position of AMS-HT E Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "18FF810000020001",
"intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead."
},
{
"ecode": "1807700000020050",
"intro": "AMS-HT H Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1803700000020030",
"intro": "AMS-HT D Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "18FF810000010003",
"intro": "The position hall signal communication acquisition of the extruder switching motor is abnormal."
},
{
"ecode": "0705300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "18FF800000010003",
"intro": "The toolhead lift motor position hall signal is abnormal during extruder switching."
},
{
"ecode": "070822000002000A",
"intro": "Failed to adjust the filament position of AMS undefined Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1803700000020045",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0700100000020002",
"intro": "The AMS A slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700110000010001",
"intro": "The AMS A slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0700200000020004",
"intro": "AMS A Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0700200000030002",
"intro": "AMS A Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0701200000030001",
"intro": "AMS B Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0701600000020001",
"intro": "The AMS B Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702600000020001",
"intro": "The AMS C Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702700000020030",
"intro": "AMS C Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0703200000020001",
"intro": "AMS D Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0703210000020002",
"intro": "AMS D Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0703220000030002",
"intro": "AMS D Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0703700000020032",
"intro": "AMS D Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0703200000020007",
"intro": "AMS D Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0702220000020007",
"intro": "AMS C Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300990000010001",
"intro": "The right side window seems to be open; the task has been paused."
},
{
"ecode": "07FF200000020002",
"intro": "No filament was detected in the right extruder from the external spool; please load the new filament."
},
{
"ecode": "1801220000030002",
"intro": "AMS-HT B Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1801220000020001",
"intro": "AMS-HT B Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1807610000020001",
"intro": "The AMS-HT H Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1806210000030002",
"intro": "AMS-HT G Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805130000010003",
"intro": "The AMS-HT F slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1802220000020001",
"intro": "AMS-HT C Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1800610000020001",
"intro": "The AMS-HT A Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1801130000020002",
"intro": "The AMS-HT B slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1807960000010003",
"intro": "AMS-HT H Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1807100000010001",
"intro": "The AMS-HT H slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1804120000020002",
"intro": "The AMS-HT E slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0707220000020005",
"intro": "AMS H Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1802130000010001",
"intro": "The AMS-HT C slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0707130000020002",
"intro": "The AMS H slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0707220000030002",
"intro": "AMS H Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1806230000020003",
"intro": "AMS-HT G Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "0705970000030001",
"intro": "AMS F chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1801230000020002",
"intro": "AMS-HT B Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1802100000010003",
"intro": "The AMS-HT C slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1805210000020004",
"intro": "AMS-HT F Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0300250000010003",
"intro": "Unable to read data from the right extruder force sensor; there may be a communication break or sensor damage."
},
{
"ecode": "1804230000020008",
"intro": "AMS-HT E Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707210000020003",
"intro": "AMS H Slot 2's filament may be broken in AMS."
},
{
"ecode": "0704220000020001",
"intro": "AMS E Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0704200000030002",
"intro": "AMS E Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0706110000020002",
"intro": "The AMS G slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805600000020001",
"intro": "The AMS-HT F Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702210000020008",
"intro": "AMS C Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705210000020007",
"intro": "AMS F Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705220000030002",
"intro": "AMS F Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0706220000020002",
"intro": "AMS G Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1800230000020004",
"intro": "AMS-HT A Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1804130000020002",
"intro": "The AMS-HT E slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802200000020001",
"intro": "AMS-HT C Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1800230000020003",
"intro": "AMS-HT A Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1803200000020009",
"intro": "Failed to extrude AMS-HT D Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1801700000020050",
"intro": "AMS-HT B Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "070522000002000A",
"intro": "Failed to adjust the filament position of AMS F Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1801700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "180022000002000A",
"intro": "Failed to adjust the filament position of AMS-HT A Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "18FF450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "1804310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0707700000020030",
"intro": "AMS H Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "18FE800000020002",
"intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model."
},
{
"ecode": "1802310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1807700000020045",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1801700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0706700000020023",
"intro": "AMS G Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1801700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0705700000020014",
"intro": "AMS F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1806700000020044",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "1800300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1807700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1800510000030001",
"intro": "The AMS is disabled; please load filament from spool holder."
},
{
"ecode": "1801700000020022",
"intro": "AMS-HT B Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1805700000020012",
"intro": "AMS-HT F Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0706700000020061",
"intro": "AMS G Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1805700000020020",
"intro": "AMS-HT F filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "180722000002000A",
"intro": "Failed to adjust the filament position of AMS-HT H Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0704230000020009",
"intro": "Failed to extrude AMS E Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "180421000002000A",
"intro": "Failed to adjust the filament position of AMS-HT E Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0300030000020002",
"intro": "The hotend cooling fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "0700220000020001",
"intro": "AMS A Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0700700000020050",
"intro": "AMS A Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0701100000020002",
"intro": "The AMS B slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702100000020002",
"intro": "The AMS C slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702210000020003",
"intro": "AMS C Slot 2's filament may be broken in AMS."
},
{
"ecode": "0702220000020002",
"intro": "AMS C Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0703120000010003",
"intro": "The AMS D slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0703130000010003",
"intro": "The AMS D slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0300260000010004",
"intro": "The signal of the extrusion force sensor of the left extruder is abnormal. The sensor may be damaged or the MC-TH communication may be abnormal."
},
{
"ecode": "0700700000020010",
"intro": "AMS A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0500050000010001",
"intro": "The factory data of the AP board is abnormal; please replace the AP board with a new one."
},
{
"ecode": "0703960000020002",
"intro": "AMS D Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1804210000020008",
"intro": "AMS-HT E Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707200000030001",
"intro": "AMS H Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1800100000020002",
"intro": "The AMS-HT A slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805210000020005",
"intro": "AMS-HT F Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804220000020008",
"intro": "AMS-HT E Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807230000020002",
"intro": "AMS-HT H Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1801210000030002",
"intro": "AMS-HT B Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1803230000020008",
"intro": "AMS-HT D Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704230000020007",
"intro": "AMS E Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807230000020007",
"intro": "AMS-HT H Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704210000020001",
"intro": "AMS E Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1807130000010001",
"intro": "The AMS-HT H slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0707230000030001",
"intro": "AMS H Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1801120000020002",
"intro": "The AMS-HT B slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805230000030001",
"intro": "AMS-HT F Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1804220000020002",
"intro": "AMS-HT E Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1806130000010001",
"intro": "The AMS-HT G slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1800230000020002",
"intro": "AMS-HT A Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0704200000020003",
"intro": "AMS E Slot 1's filament may be broken in AMS."
},
{
"ecode": "0706220000020004",
"intro": "AMS G Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1801200000020002",
"intro": "AMS-HT B Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0706230000020002",
"intro": "AMS G Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0300250000010002",
"intro": "The sensitivity of the right extruder extrusion force sensor is low; the nozzle may not installed correctly."
},
{
"ecode": "1800210000020003",
"intro": "AMS-HT A Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "0706210000020001",
"intro": "AMS G Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1801600000020001",
"intro": "The AMS-HT B Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0707220000030001",
"intro": "AMS H Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1803210000020008",
"intro": "AMS-HT D Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707610000020001",
"intro": "The AMS H Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0704700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1807310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0706700000020046",
"intro": "AMS G Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "1803700000020060",
"intro": "AMS-HT D Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0704700000020011",
"intro": "AMS E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "180121000002000A",
"intro": "Failed to adjust the filament position of AMS-HT B Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1807700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0704700000020031",
"intro": "AMS E Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1800700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0705700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1804700000020023",
"intro": "AMS-HT E Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1800700000020060",
"intro": "AMS-HT A Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "1806700000020030",
"intro": "AMS-HT G Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0706700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0704700000020013",
"intro": "AMS E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "0706700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1803700000020013",
"intro": "AMS-HT D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "180620000002000A",
"intro": "Failed to adjust the filament position of AMS-HT G Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1802700000020045",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1802700000020050",
"intro": "AMS-HT C Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1805210000020009",
"intro": "Failed to extrude AMS-HT F Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1803700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0707700000020011",
"intro": "AMS H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1807300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1801700000020023",
"intro": "AMS-HT B Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "03009C0000010001",
"intro": "The active airflow assist module is not detected, please check whether the connector is plugged in properly."
},
{
"ecode": "1805200000020009",
"intro": "Failed to extrude AMS-HT F Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1803700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0700130000010003",
"intro": "The AMS A slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701110000020002",
"intro": "The AMS B slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0701210000030001",
"intro": "AMS B Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0701220000030002",
"intro": "AMS B Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0701230000030002",
"intro": "AMS B Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0701700000020032",
"intro": "AMS B Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0702210000020002",
"intro": "AMS C Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0702230000020005",
"intro": "AMS C Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0703200000020002",
"intro": "AMS D Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0703210000030002",
"intro": "AMS D Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0300250000010008",
"intro": "The right nozzle touches the heating bed abnormally. Please check whether there is filament residue on the nozzle or foreign matter where the nozzle touches the bed."
},
{
"ecode": "0500060000020024",
"intro": "liveview camera detects low cif/isp/ispp frame rates."
},
{
"ecode": "0700230000020007",
"intro": "AMS A Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701700000020023",
"intro": "AMS B Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "0701230000020007",
"intro": "AMS B Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801210000030001",
"intro": "AMS-HT B Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1802110000010001",
"intro": "The AMS-HT C slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1805230000020004",
"intro": "AMS-HT F Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0706200000020002",
"intro": "AMS G Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0706200000020008",
"intro": "AMS G Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706210000020005",
"intro": "AMS G Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1801630000020001",
"intro": "The AMS-HT B Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0705220000020004",
"intro": "AMS F Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0706120000010003",
"intro": "The AMS G slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1803220000020001",
"intro": "AMS-HT D Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0705130000020002",
"intro": "The AMS F slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0704230000030001",
"intro": "AMS E Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806960000020002",
"intro": "AMS-HT G Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "0704120000020002",
"intro": "The AMS E slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1800100000010003",
"intro": "The AMS-HT A slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706610000020001",
"intro": "The AMS G Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1805200000020003",
"intro": "AMS-HT F Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "1801200000020005",
"intro": "AMS-HT B Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0707200000020002",
"intro": "AMS H Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0704600000020001",
"intro": "The AMS E Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800200000030002",
"intro": "AMS-HT A Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1803200000020008",
"intro": "AMS-HT D Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801210000020002",
"intro": "AMS-HT B Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1802120000010001",
"intro": "The AMS-HT C slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1803230000020003",
"intro": "AMS-HT D Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1807200000030001",
"intro": "AMS-HT H Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706130000010003",
"intro": "The AMS G slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706200000020005",
"intro": "AMS G Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "07FF700000020003",
"intro": "The right extruder filament is used up; please feed new filament."
},
{
"ecode": "180221000002000A",
"intro": "Failed to adjust the filament position of AMS-HT C Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "070021000002000A",
"intro": "Failed to adjust the filament position of AMS A Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0706310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0704700000020061",
"intro": "AMS E Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1805700000020033",
"intro": "AMS-HT F Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1803210000020009",
"intro": "Failed to extrude AMS-HT D Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1807700000020014",
"intro": "AMS-HT H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1805700000020041",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "1800700000020012",
"intro": "AMS-HT A Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "180622000002000A",
"intro": "Failed to adjust the filament position of AMS-HT G Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0706200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "0500040000020042",
"intro": "Nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "1800700000020010",
"intro": "AMS-HT A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0704700000020043",
"intro": "AMS E Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "03009C0000010002",
"intro": "The active airflow assist module is abnormal and may be damaged."
},
{
"ecode": "1804700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "180423000002000A",
"intro": "Failed to adjust the filament position of AMS-HT E Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "0704210000020009",
"intro": "Failed to extrude AMS E Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1807700000020012",
"intro": "AMS-HT H Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0704700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0707700000020022",
"intro": "AMS H Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "180723000002000A",
"intro": "Failed to adjust the filament position of AMS-HT H Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1804700000020050",
"intro": "AMS-HT E Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1804700000020043",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1807200000020009",
"intro": "Failed to extrude AMS-HT H Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0706220000020009",
"intro": "Failed to extrude AMS G Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0706700000020022",
"intro": "AMS G Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1807700000020032",
"intro": "AMS-HT H Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0705700000020032",
"intro": "AMS F Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1800450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "0500030000030007",
"intro": "A system panic occurred. It has been recovered by automatic restart."
},
{
"ecode": "0701210000020003",
"intro": "AMS B Slot 2's filament may be broken in AMS."
},
{
"ecode": "0701700000020031",
"intro": "AMS B Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0701700000020060",
"intro": "AMS B Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0702110000010003",
"intro": "The AMS C slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0702120000010003",
"intro": "The AMS C slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0702700000020032",
"intro": "AMS C Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0703700000020045",
"intro": "AMS D Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0700700000020013",
"intro": "AMS A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "0702700000020023",
"intro": "AMS C Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "07FF800000020001",
"intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead."
},
{
"ecode": "0703700000020013",
"intro": "AMS D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "07FE800000020001",
"intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead."
},
{
"ecode": "1801100000020002",
"intro": "The AMS-HT B slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804130000010003",
"intro": "The AMS-HT E slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806100000010001",
"intro": "The AMS-HT G slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802230000020007",
"intro": "AMS-HT C Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802600000020001",
"intro": "The AMS-HT C Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1807220000020008",
"intro": "AMS-HT H Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800550000010003",
"intro": "AMS-HT A was detected offline during the AMS initialization process."
},
{
"ecode": "1805200000020001",
"intro": "AMS-HT F Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0706230000020004",
"intro": "AMS G Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1800230000020007",
"intro": "AMS-HT A Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1806210000020001",
"intro": "AMS-HT G Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1807230000020001",
"intro": "AMS-HT H Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0300260000010003",
"intro": "Unable to read data from the left extruder force sensor; there may be a communication break or sensor damage."
},
{
"ecode": "1800130000020002",
"intro": "The AMS-HT A slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0707100000010001",
"intro": "The AMS H slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1801100000010001",
"intro": "The AMS-HT B slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1800210000020007",
"intro": "AMS-HT A Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807560000030001",
"intro": "AMS-HT H is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1804220000030002",
"intro": "AMS-HT E Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1807200000020003",
"intro": "AMS-HT H Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "1804200000020004",
"intro": "AMS-HT E Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1802960000010003",
"intro": "AMS-HT C Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1807120000010003",
"intro": "The AMS-HT H slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701230000020008",
"intro": "AMS B Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "07FE800000020003",
"intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate."
},
{
"ecode": "1803200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "1804700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "070423000002000A",
"intro": "Failed to adjust the filament position of AMS E Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1806200000020009",
"intro": "Failed to extrude AMS-HT G Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0704200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "0704700000020021",
"intro": "AMS E Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1807700000020030",
"intro": "AMS-HT H Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0705350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0C00030000020012",
"intro": "Foreign object detection is not working. It's recommended to uninstall the laser or cutting module if it was installed, and tab \"Settings>Toolbox\" on printer screen and re-calibrate the Live View Camera."
},
{
"ecode": "1800400000020004",
"intro": "The filament buffer signal is abnormal; the spring may be stuck, or the filament may be tangled."
},
{
"ecode": "1805700000020061",
"intro": "AMS-HT F Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "0706700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1801700000020013",
"intro": "AMS-HT B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1800700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1803700000020010",
"intro": "AMS-HT D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0705700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1802700000020040",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1807700000020040",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1802700000020031",
"intro": "AMS-HT C Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1800450000020001",
"intro": "The filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in."
},
{
"ecode": "0707700000020032",
"intro": "AMS H Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1804700000020031",
"intro": "AMS-HT E Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1801700000020012",
"intro": "AMS-HT B Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "070022000002000A",
"intro": "Failed to adjust the filament position of AMS A Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0704300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1802700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1804700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0C0003000002000E",
"intro": "Your nozzle seems to be covered with jammed or clogged material."
},
{
"ecode": "1800700000020020",
"intro": "AMS-HT A filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0700700000020044",
"intro": "AMS A Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0701130000020002",
"intro": "The AMS B slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0701230000020003",
"intro": "AMS B Slot 4's filament may be broken in AMS."
},
{
"ecode": "0702220000030002",
"intro": "AMS C Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0702230000030001",
"intro": "AMS C Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0702700000020042",
"intro": "AMS C Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0702700000020045",
"intro": "AMS C Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0702700000020050",
"intro": "AMS C Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0703700000020046",
"intro": "AMS D Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "1201300000010004",
"intro": "RFID cannot be read because of an encryption chip failure in AMS B."
},
{
"ecode": "0703210000020007",
"intro": "AMS D Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0703700000020020",
"intro": "AMS D filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0701700000020014",
"intro": "AMS B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0700700000020023",
"intro": "AMS A Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "0300250000010007",
"intro": "The frequency of the extrusion force sensor of the right extruder is too high. The sensor may be damaged or the nozzle heat sink may be too close to the sensor."
},
{
"ecode": "0703700000020011",
"intro": "AMS D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0300270000010004",
"intro": "The signal of the nozzle offset calibration sensor is abnormal. The sensor may be damaged or the wiring may not be connected properly."
},
{
"ecode": "0701960000010003",
"intro": "AMS B Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1805120000020002",
"intro": "The AMS-HT F slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805100000020002",
"intro": "The AMS-HT F slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805630000020001",
"intro": "The AMS-HT F Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702230000020008",
"intro": "AMS C Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804230000020007",
"intro": "AMS-HT E Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803210000020001",
"intro": "AMS-HT D Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1804210000020001",
"intro": "AMS-HT E Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1805200000020008",
"intro": "AMS-HT F Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802220000020005",
"intro": "AMS-HT C Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0707200000030002",
"intro": "AMS H Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1804100000020002",
"intro": "The AMS-HT E slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0707200000020007",
"intro": "AMS H Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801200000030001",
"intro": "AMS-HT B Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1805230000020001",
"intro": "AMS-HT F Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0706230000030001",
"intro": "AMS G Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806200000020003",
"intro": "AMS-HT G Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "1807960000020002",
"intro": "AMS-HT H Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1804210000020005",
"intro": "AMS-HT E Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1802210000020001",
"intro": "AMS-HT C Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1800550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1802110000020002",
"intro": "The AMS-HT C slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1805200000020007",
"intro": "AMS-HT F Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802200000020008",
"intro": "AMS-HT C Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705200000030002",
"intro": "AMS F Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0703210000020008",
"intro": "AMS D Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803200000020007",
"intro": "AMS-HT D Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707600000020001",
"intro": "The AMS H Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0704230000020005",
"intro": "AMS E Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1805220000020008",
"intro": "AMS-HT F Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800220000020003",
"intro": "AMS-HT A Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "1804210000030001",
"intro": "AMS-HT E Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1807220000030002",
"intro": "AMS-HT H Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0706960000010003",
"intro": "AMS G Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1803130000010001",
"intro": "The AMS-HT D slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "070621000002000A",
"intro": "Failed to adjust the filament position of AMS G Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1807700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0704700000020030",
"intro": "AMS E Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0C00030000020015",
"intro": "Foreign object detection is not working. Detected the Live View Camera has been replaced. If a laser or cutting module is installed, please uninstall the module, tab \"Settings>Toolbox\" on printer screen and re-calibrate the Live View Camera."
},
{
"ecode": "1802700000020012",
"intro": "AMS-HT C Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "1802700000020041",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "070020000002000A",
"intro": "Failed to adjust the filament position of AMS A Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020013",
"intro": "AMS F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1803310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0706700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "070222000002000A",
"intro": "Failed to adjust the filament position of AMS C Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1806350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1803350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0706700000020021",
"intro": "AMS G Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "180021000002000A",
"intro": "Failed to adjust the filament position of AMS-HT A Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "18FE800000010002",
"intro": "The toolhead lift motor position hall sensor is abnormal, please check whether the connecting cable is loose."
},
{
"ecode": "1805700000020013",
"intro": "AMS-HT F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1806700000020040",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1800200000020009",
"intro": "Failed to extrude AMS-HT A Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1800700000020011",
"intro": "AMS-HT A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1806700000020045",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1804200000020009",
"intro": "Failed to extrude AMS-HT E Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "070821000002000A",
"intro": "Failed to adjust the filament position of AMS undefined Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1800700000020050",
"intro": "AMS-HT A Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1806700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1801200000020009",
"intro": "Failed to extrude AMS-HT B Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0704310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1805700000020040",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0700700000020060",
"intro": "AMS A Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0701200000020005",
"intro": "AMS B Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0701700000020046",
"intro": "AMS B Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0702200000030001",
"intro": "AMS C Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0702200000030002",
"intro": "AMS C Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0702210000030001",
"intro": "AMS C Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0703220000020003",
"intro": "AMS D Slot 3's filament may be broken in AMS."
},
{
"ecode": "0703700000020030",
"intro": "AMS D Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0300C00000010002",
"intro": "Filter Switch Flap malfunction: it may be stuck."
},
{
"ecode": "0702230000020007",
"intro": "AMS C Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0700700000020021",
"intro": "AMS A Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1803230000030002",
"intro": "AMS-HT D Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1804120000010001",
"intro": "The AMS-HT E slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802560000030001",
"intro": "AMS-HT C is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1803200000020003",
"intro": "AMS-HT D Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "1803620000020001",
"intro": "The AMS-HT D Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1801200000020008",
"intro": "AMS-HT B Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807200000020007",
"intro": "AMS-HT H Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707210000030001",
"intro": "AMS H Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806630000020001",
"intro": "The AMS-HT G Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1801550000010003",
"intro": "AMS-HT B was detected offline during the AMS initialization process."
},
{
"ecode": "1807200000020004",
"intro": "AMS-HT H Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1800230000030001",
"intro": "AMS-HT A Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1801130000010003",
"intro": "The AMS-HT B slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1800620000020001",
"intro": "The AMS-HT A Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800120000020002",
"intro": "The AMS-HT A slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1801200000020007",
"intro": "AMS-HT B Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705560000030001",
"intro": "AMS F is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1807600000020001",
"intro": "The AMS-HT H Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1805960000010003",
"intro": "AMS-HT F Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0705630000020001",
"intro": "The AMS F Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1802220000020008",
"intro": "AMS-HT C Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706110000010001",
"intro": "The AMS G slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0705200000020001",
"intro": "AMS F Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0704110000020002",
"intro": "The AMS E slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0706200000020001",
"intro": "AMS G Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1804560000030001",
"intro": "AMS-HT E is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1802120000020002",
"intro": "The AMS-HT C slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1807620000020001",
"intro": "The AMS-HT H Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1804220000020007",
"intro": "AMS-HT E Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705120000010003",
"intro": "The AMS F slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706220000030001",
"intro": "AMS G Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1802230000030001",
"intro": "AMS-HT C Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706230000030002",
"intro": "AMS G Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "07FE700000020003",
"intro": "The left extruder filament is used up; please feed new filament."
},
{
"ecode": "1803700000020012",
"intro": "AMS-HT D Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "07FE450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "0707700000020020",
"intro": "AMS H filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "1803310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0706700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1806700000020014",
"intro": "AMS-HT G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "180621000002000A",
"intro": "Failed to adjust the filament position of AMS-HT G Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020040",
"intro": "AMS F Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "03009B0000010002",
"intro": "Safety key is not inserted; please install correctly as guided."
},
{
"ecode": "0C00030000020014",
"intro": "Foreign object detection is not working. It's recommended to uninstall the laser or cutting module if it was installed, and tab \"Settings>Toolbox\" on printer screen and re-calibrate the Live View Camera."
},
{
"ecode": "0500040000020044",
"intro": "The print plate type is unknown; please replace it with the correct plate and check if the live view camera is obstructed."
},
{
"ecode": "0300D00000010001",
"intro": "The cutting fixture has fallen off; please reinstall it."
},
{
"ecode": "0705700000020044",
"intro": "AMS F Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "07FF450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "1800700000020041",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0705700000020020",
"intro": "AMS F filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "180523000002000A",
"intro": "Failed to adjust the filament position of AMS-HT F Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1802700000020061",
"intro": "AMS-HT C Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1800300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0C00040000020006",
"intro": ""
},
{
"ecode": "1806700000020011",
"intro": "AMS-HT G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1803700000020042",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "18FF200000020004",
"intro": "Please pull the external filament from the right extruder."
},
{
"ecode": "0700230000030002",
"intro": "AMS A Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0700610000020001",
"intro": "The AMS A Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0701220000030001",
"intro": "AMS B Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0701700000020033",
"intro": "AMS B Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "0702110000020002",
"intro": "The AMS C slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702700000020044",
"intro": "AMS C Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0702700000020046",
"intro": "AMS C Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0703130000010001",
"intro": "The AMS D slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0703200000020005",
"intro": "AMS D Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0703700000020033",
"intro": "AMS D Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1200300000010004",
"intro": "RFID cannot be read because of an encryption chip failure in AMS A."
},
{
"ecode": "1202300000010004",
"intro": "RFID cannot be read because of an encryption chip failure in AMS C."
},
{
"ecode": "0702200000020007",
"intro": "AMS C Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0702700000020011",
"intro": "AMS C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0701700000020013",
"intro": "AMS B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "0700700000020022",
"intro": "AMS A Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0701200000020008",
"intro": "AMS B Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0702700000020010",
"intro": "AMS C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1807200000020001",
"intro": "AMS-HT H Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1806200000020002",
"intro": "AMS-HT G Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0705220000020002",
"intro": "AMS F Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1804610000020001",
"intro": "The AMS-HT E Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1807110000020002",
"intro": "The AMS-HT H slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802220000030002",
"intro": "AMS-HT C Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805220000020003",
"intro": "AMS-HT F Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "0705100000020002",
"intro": "The AMS F slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802630000020001",
"intro": "The AMS-HT C Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800220000020001",
"intro": "AMS-HT A Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0706130000020002",
"intro": "The AMS G slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1803210000020004",
"intro": "AMS-HT D Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1804210000020003",
"intro": "AMS-HT E Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "1803210000020003",
"intro": "AMS-HT D Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "1804200000030001",
"intro": "AMS-HT E Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1801230000020001",
"intro": "AMS-HT B Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0704230000020002",
"intro": "AMS E Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1802200000020003",
"intro": "AMS-HT C Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "0706100000010001",
"intro": "The AMS G slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802230000020003",
"intro": "AMS-HT C Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1807110000010001",
"intro": "The AMS-HT H slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0705210000020002",
"intro": "AMS F Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0706200000030001",
"intro": "AMS G Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1800220000030002",
"intro": "AMS-HT A Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0704210000020005",
"intro": "AMS E Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1801230000020005",
"intro": "AMS-HT B Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706200000020007",
"intro": "AMS G Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806700000020021",
"intro": "AMS-HT G Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1807700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1802700000020044",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0706700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "1803700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0705220000020009",
"intro": "Failed to extrude AMS F Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "18FF810000010001",
"intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "1804300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1805700000020030",
"intro": "AMS-HT F Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0707700000020040",
"intro": "AMS H Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0706700000020020",
"intro": "AMS G filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "180320000002000A",
"intro": "Failed to adjust the filament position of AMS-HT D Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0707700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1801700000020030",
"intro": "AMS-HT B Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "070421000002000A",
"intro": "Failed to adjust the filament position of AMS E Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1806700000020043",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1801700000020060",
"intro": "AMS-HT B Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0704700000020010",
"intro": "AMS E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1805300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "180220000002000A",
"intro": "Failed to adjust the filament position of AMS-HT C Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1801300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1803700000020032",
"intro": "AMS-HT D Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0705700000020030",
"intro": "AMS F Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "1806700000020041",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "1804200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "1800700000020014",
"intro": "AMS-HT A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1806230000020009",
"intro": "Failed to extrude AMS-HT G Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0707700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0705700000020042",
"intro": "AMS F Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1800220000020009",
"intro": "Failed to extrude AMS-HT A Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700120000010001",
"intro": "The AMS A slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0700600000020001",
"intro": "The AMS A Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0701130000010003",
"intro": "The AMS B slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0702130000020002",
"intro": "The AMS C slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702700000020040",
"intro": "AMS C Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0703130000020002",
"intro": "The AMS D slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0703220000020002",
"intro": "AMS D Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0703230000030001",
"intro": "AMS D Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0703700000020040",
"intro": "AMS D Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0702200000020008",
"intro": "AMS C Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701700000020012",
"intro": "AMS B Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0703700000020023",
"intro": "AMS D Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "0704970000030001",
"intro": "AMS E chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1807100000010003",
"intro": "The AMS-HT H slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1802200000030002",
"intro": "AMS-HT C Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0705210000020005",
"intro": "AMS F Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706220000020003",
"intro": "AMS G Slot 3's filament may be broken in AMS."
},
{
"ecode": "0707200000020004",
"intro": "AMS H Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1803230000030001",
"intro": "AMS-HT D Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1802220000030001",
"intro": "AMS-HT C Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1803220000030002",
"intro": "AMS-HT D Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1801230000020004",
"intro": "AMS-HT B Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0704110000010001",
"intro": "The AMS E slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807220000030001",
"intro": "AMS-HT H Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0704210000020008",
"intro": "AMS E Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805230000020002",
"intro": "AMS-HT F Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1803220000030001",
"intro": "AMS-HT D Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1804210000030002",
"intro": "AMS-HT E Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0705130000010001",
"intro": "The AMS F slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0705210000030001",
"intro": "AMS F Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1802200000030001",
"intro": "AMS-HT C Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1801120000010001",
"intro": "The AMS-HT B slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1805120000010003",
"intro": "The AMS-HT F slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705220000020008",
"intro": "AMS F Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801220000020004",
"intro": "AMS-HT B Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0705120000020002",
"intro": "The AMS F slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0704220000020007",
"intro": "AMS E Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705700000020021",
"intro": "AMS F Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1805700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1800310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0704700000020020",
"intro": "AMS E filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "1802700000020011",
"intro": "AMS-HT C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1800450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "0706700000020010",
"intro": "AMS G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1805700000020046",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "1807700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0706700000020060",
"intro": "AMS G Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "1804350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1801700000020041",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0500040000020047",
"intro": "Foreign objects detected on heatbed; please check and clean the heatbed."
},
{
"ecode": "1806300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1807310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "050004000001004F",
"intro": "Unknown module detected, please try updating the firmware to the latest version."
},
{
"ecode": "18FE700000020003",
"intro": "The left extruder filament is used up; please feed new filament."
},
{
"ecode": "1802700000020023",
"intro": "AMS-HT C Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "0300D00000010002",
"intro": "The cutting tool has fallen off; please reinstall it."
},
{
"ecode": "1803700000020022",
"intro": "AMS-HT D Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1805700000020022",
"intro": "AMS-HT F Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1807300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0707700000020045",
"intro": "AMS H Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1800700000020032",
"intro": "AMS-HT A Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0707200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "1802300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1806700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1802310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0705310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "18FF700000020003",
"intro": "The right extruder filament is used up; please feed new filament."
},
{
"ecode": "1800700000020031",
"intro": "AMS-HT A Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1802700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "1803700000020040",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1803700000020044",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "18FE810000010002",
"intro": "The position hall sensor of the extruder switching motor is abnormal. Please check whether the connecting cable is loose."
},
{
"ecode": "0700230000030001",
"intro": "AMS A Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0700700000020040",
"intro": "AMS A Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0701200000020003",
"intro": "AMS B Slot 1's filament may be broken in AMS."
},
{
"ecode": "0701220000020005",
"intro": "AMS B Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702220000020004",
"intro": "AMS C Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0703100000010001",
"intro": "The AMS D slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0703110000010003",
"intro": "The AMS D slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0703110000020002",
"intro": "The AMS D slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0703200000020004",
"intro": "AMS D Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0703200000030002",
"intro": "AMS D Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0703220000030001",
"intro": "AMS D Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0702700000020022",
"intro": "AMS C Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0701700000020011",
"intro": "AMS B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0700700000020014",
"intro": "AMS A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0702960000020002",
"intro": "AMS C Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1806600000020001",
"intro": "The AMS-HT G Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0707130000010001",
"intro": "The AMS H slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802610000020001",
"intro": "The AMS-HT C Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800220000020007",
"intro": "AMS-HT A Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805100000010003",
"intro": "The AMS-HT F slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1800200000020005",
"intro": "AMS-HT A Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702220000020008",
"intro": "AMS C Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704120000010001",
"intro": "The AMS E slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1805130000010001",
"intro": "The AMS-HT F slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0705230000020001",
"intro": "AMS F Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0705110000010001",
"intro": "The AMS F slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1803960000020002",
"intro": "AMS-HT D Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1807220000020007",
"intro": "AMS-HT H Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805220000020005",
"intro": "AMS-HT F Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1805550000010003",
"intro": "AMS-HT F was detected offline during the AMS initialization process."
},
{
"ecode": "1801220000020008",
"intro": "AMS-HT B Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806200000030001",
"intro": "AMS-HT G Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706230000020005",
"intro": "AMS G Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706200000020003",
"intro": "AMS G Slot 1's filament may be broken in AMS."
},
{
"ecode": "0704200000020008",
"intro": "AMS E Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801610000020001",
"intro": "The AMS-HT B Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0705220000020001",
"intro": "AMS F Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1805230000020003",
"intro": "AMS-HT F Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1804110000010001",
"intro": "The AMS-HT E slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1806110000020002",
"intro": "The AMS-HT G slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "180623000002000A",
"intro": "Failed to adjust the filament position of AMS-HT G Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "18FE810000010003",
"intro": "The position hall signal communication acquisition of the extruder switching motor is abnormal."
},
{
"ecode": "070720000002000A",
"intro": "Failed to adjust the filament position of AMS H Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "03009D0000020001",
"intro": "The engrave laser focal point XY calibration has failed; please clean up the Laser Homing Area on the Laser Platform, and re-run the Laser Module mount calibration."
},
{
"ecode": "1803300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "180223000002000A",
"intro": "Failed to adjust the filament position of AMS-HT C Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1801700000020010",
"intro": "AMS-HT B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1804700000020022",
"intro": "AMS-HT E Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1805310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0706700000020050",
"intro": "AMS G Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0706350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1805700000020014",
"intro": "AMS-HT F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1800700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "180820000002000A",
"intro": "Failed to adjust the filament position of AMS-HT undefined Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1807210000020009",
"intro": "Failed to extrude AMS-HT H Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "070520000002000A",
"intro": "Failed to adjust the filament position of AMS F Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1802700000020032",
"intro": "AMS-HT C Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1803700000020061",
"intro": "AMS-HT D Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1801700000020043",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0707310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1807700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1805220000020009",
"intro": "Failed to extrude AMS-HT F Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1801700000020046",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0707230000020009",
"intro": "Failed to extrude AMS H Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1806310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1802700000020030",
"intro": "AMS-HT C Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "1804700000020046",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0707700000020031",
"intro": "AMS H Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0700110000010003",
"intro": "The AMS A slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701230000020002",
"intro": "AMS B Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0701230000020005",
"intro": "AMS B Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0701700000020043",
"intro": "AMS B Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0702210000020005",
"intro": "AMS C Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702620000020001",
"intro": "The AMS C Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702700000020060",
"intro": "AMS C Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0703120000010001",
"intro": "The AMS D slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0703200000030001",
"intro": "AMS D Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0703230000020002",
"intro": "AMS D Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0700220000020007",
"intro": "AMS A Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300280000010007",
"intro": "Communication between the cutting module and toolhead module failed."
},
{
"ecode": "0702970000030001",
"intro": "AMS C chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0C00030000020011",
"intro": "The high-precision nozzle offset calibration failed; please recalibrate."
},
{
"ecode": "1802970000030001",
"intro": "AMS-HT C chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1804960000010003",
"intro": "AMS-HT E Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1803600000020001",
"intro": "The AMS-HT D Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1800220000020008",
"intro": "AMS-HT A Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705610000020001",
"intro": "The AMS F Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0705210000020008",
"intro": "AMS F Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "0701220000020008",
"intro": "AMS B Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803110000020002",
"intro": "The AMS-HT D slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1801210000020007",
"intro": "AMS-HT B Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806210000030001",
"intro": "AMS-HT G Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1804100000010001",
"intro": "The AMS-HT E slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1800210000020008",
"intro": "AMS-HT A Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705200000020002",
"intro": "AMS F Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1802550000010003",
"intro": "AMS-HT C was detected offline during the AMS initialization process."
},
{
"ecode": "1806220000020007",
"intro": "AMS-HT G Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800110000010001",
"intro": "The AMS-HT A slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807220000020002",
"intro": "AMS-HT H Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1801200000020001",
"intro": "AMS-HT B Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1801230000020008",
"intro": "AMS-HT B Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "0705130000010003",
"intro": "The AMS F slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1805210000030001",
"intro": "AMS-HT F Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0704110000010003",
"intro": "The AMS E slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1800200000030001",
"intro": "AMS-HT A Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706230000020003",
"intro": "AMS G Slot 4's filament may be broken in AMS."
},
{
"ecode": "1800220000020004",
"intro": "AMS-HT A Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1803210000020007",
"intro": "AMS-HT D Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706130000010001",
"intro": "The AMS G slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807230000020005",
"intro": "AMS-HT H Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1805210000020008",
"intro": "AMS-HT F Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807230000020004",
"intro": "AMS-HT H Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1802230000020001",
"intro": "AMS-HT C Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "1805110000010003",
"intro": "The AMS-HT F slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0704200000020005",
"intro": "AMS E Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804600000020001",
"intro": "The AMS-HT E Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0707230000020008",
"intro": "AMS H Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "180520000002000A",
"intro": "Failed to adjust the filament position of AMS-HT F Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0C00010000010013",
"intro": "The Live View Camera calibration failed and the Liveview camera serial number cannot be read. Please contact the customer support team."
},
{
"ecode": "1803700000020020",
"intro": "AMS-HT D filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0704700000020022",
"intro": "AMS E Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0704700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1804700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "180823000002000A",
"intro": "Failed to adjust the filament position of AMS-HT undefined Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "18FF450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "0704700000020014",
"intro": "AMS E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0704700000020045",
"intro": "AMS E Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0C0001000001000F",
"intro": "The Live View Camera calibration failed. Please restart the devices or update the firmware."
},
{
"ecode": "1806700000020042",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1800700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0706210000020009",
"intro": "Failed to extrude AMS G Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1805700000020044",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "1800210000020009",
"intro": "Failed to extrude AMS-HT A Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1802300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1804700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "070120000002000A",
"intro": "Failed to adjust the filament position of AMS B Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0707700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1803700000020021",
"intro": "AMS-HT D Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1806700000020032",
"intro": "AMS-HT G Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0704700000020044",
"intro": "AMS E Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "18FE800000010001",
"intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "050004000002004D",
"intro": "The cutting protection base is not detected; please make sure it is placed correctly."
},
{
"ecode": "0700200000020001",
"intro": "AMS A Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0701130000010001",
"intro": "The AMS B slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0701200000020001",
"intro": "AMS B Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0701610000020001",
"intro": "The AMS B Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702200000020003",
"intro": "AMS C Slot 1's filament may be broken in AMS."
},
{
"ecode": "0703110000010001",
"intro": "The AMS D slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0701220000020007",
"intro": "AMS B Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701960000020002",
"intro": "AMS B Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "0703960000010003",
"intro": "AMS D Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0701970000030001",
"intro": "AMS B chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0707960000020002",
"intro": "AMS H Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1800230000030002",
"intro": "AMS-HT A Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0704220000020003",
"intro": "AMS E Slot 3's filament may be broken in AMS."
},
{
"ecode": "0707110000010001",
"intro": "The AMS H slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1801120000010003",
"intro": "The AMS-HT B slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0704560000030001",
"intro": "AMS E is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1803200000020005",
"intro": "AMS-HT D Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706230000020008",
"intro": "AMS G Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801100000010003",
"intro": "The AMS-HT B slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806220000020003",
"intro": "AMS-HT G Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "1803220000020002",
"intro": "AMS-HT D Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1804200000020003",
"intro": "AMS-HT E Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "0707230000020002",
"intro": "AMS H Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1803130000020002",
"intro": "The AMS-HT D slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804630000020001",
"intro": "The AMS-HT E Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1806100000020002",
"intro": "The AMS-HT G slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1806200000020005",
"intro": "AMS-HT G Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804230000030001",
"intro": "AMS-HT E Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1800220000030001",
"intro": "AMS-HT A Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1803200000020001",
"intro": "AMS-HT D Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1806220000020008",
"intro": "AMS-HT G Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1805200000030001",
"intro": "AMS-HT F Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706210000020002",
"intro": "AMS G Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0706210000020004",
"intro": "AMS G Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1806220000030002",
"intro": "AMS-HT G Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0707200000020001",
"intro": "AMS H Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1807200000030002",
"intro": "AMS-HT H Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1806200000020001",
"intro": "AMS-HT G Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0707210000020007",
"intro": "AMS H Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804970000030001",
"intro": "AMS-HT E chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1807230000020008",
"intro": "AMS-HT H Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707210000020001",
"intro": "AMS H Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1800100000010001",
"intro": "The AMS-HT A slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0704610000020001",
"intro": "The AMS E Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0706630000020001",
"intro": "The AMS G Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1801970000030001",
"intro": "AMS-HT B chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1801550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "0706960000020002",
"intro": "AMS G Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1807700000020010",
"intro": "AMS-HT H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0500040000020045",
"intro": "The detected 3D printing plate type does not match the one selected in the slicer."
},
{
"ecode": "0704700000020023",
"intro": "AMS E Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1802700000020013",
"intro": "AMS-HT C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1807700000020041",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0300930000010005",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air inlet may have a short circuit."
},
{
"ecode": "1801700000020033",
"intro": "AMS-HT B Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1801700000020044",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0706700000020012",
"intro": "AMS G Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0706700000020031",
"intro": "AMS G Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1802700000020014",
"intro": "AMS-HT C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1802210000020009",
"intro": "Failed to extrude AMS-HT C Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "180721000002000A",
"intro": "Failed to adjust the filament position of AMS-HT H Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0704700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "1803700000020041",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0706300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0706300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "05FE040000020041",
"intro": "The left hotend can't be identified, possibly due non-official hotend. It could also be the blocked live view camera or the damaged nozzle marker."
},
{
"ecode": "1806700000020060",
"intro": "AMS-HT G Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "1803700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "03009B0000010001",
"intro": "Emergency stop button is not installed; please install correctly as guided."
},
{
"ecode": "0707700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "070521000002000A",
"intro": "Failed to adjust the filament position of AMS F Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0707700000020044",
"intro": "AMS H Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "1802200000020009",
"intro": "Failed to extrude AMS-HT C Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1800700000020046",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "1807700000020060",
"intro": "AMS-HT H Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "1807700000020044",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0700210000020002",
"intro": "AMS A Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0701120000020002",
"intro": "The AMS B slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0701200000020002",
"intro": "AMS B Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0701210000020001",
"intro": "AMS B Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0701700000020045",
"intro": "AMS B Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0702100000010003",
"intro": "The AMS C slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0702200000020004",
"intro": "AMS C Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0702210000030002",
"intro": "AMS C Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0703210000020003",
"intro": "AMS D Slot 2's filament may be broken in AMS."
},
{
"ecode": "0703210000020005",
"intro": "AMS D Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0703220000020001",
"intro": "AMS D Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0703700000020060",
"intro": "AMS D Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0500040000020031",
"intro": "A new BirdsEye Camera or a camera angle shift was detected. Please go to setup before use."
},
{
"ecode": "0703200000020008",
"intro": "AMS D Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0700960000020002",
"intro": "AMS A Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "0300180000030009",
"intro": "High heatbed temperature printing is performed for the first time. In order to obtain better first layer printing quality, high temperature heatbed calibration is being automatically performed."
},
{
"ecode": "0704200000020007",
"intro": "AMS E Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803120000020002",
"intro": "The AMS-HT D slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802620000020001",
"intro": "The AMS-HT C Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1804220000030001",
"intro": "AMS-HT E Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0705200000020007",
"intro": "AMS F Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800200000020002",
"intro": "AMS-HT A Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1800630000020001",
"intro": "The AMS-HT A Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1807230000020003",
"intro": "AMS-HT H Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1803130000010003",
"intro": "The AMS-HT D slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1807230000030001",
"intro": "AMS-HT H Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1804550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1807120000010001",
"intro": "The AMS-HT H slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1803120000010003",
"intro": "The AMS-HT D slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706210000020008",
"intro": "AMS G Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707230000030002",
"intro": "AMS H Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1807220000020001",
"intro": "AMS-HT H Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1806120000010003",
"intro": "The AMS-HT G slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1807210000020005",
"intro": "AMS-HT H Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1807110000010003",
"intro": "The AMS-HT H slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1803960000010003",
"intro": "AMS-HT D Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0704220000030002",
"intro": "AMS E Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1806210000020005",
"intro": "AMS-HT G Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0707220000020007",
"intro": "AMS H Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706210000030002",
"intro": "AMS G Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805620000020001",
"intro": "The AMS-HT F Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1801130000010001",
"intro": "The AMS-HT B slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1803120000010001",
"intro": "The AMS-HT D slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0705220000020003",
"intro": "AMS F Slot 3's filament may be broken in AMS."
},
{
"ecode": "1800200000020008",
"intro": "AMS-HT A Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807210000020007",
"intro": "AMS-HT H Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801110000010003",
"intro": "The AMS-HT B slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1805100000010001",
"intro": "The AMS-HT F slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1800230000020005",
"intro": "AMS-HT A Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1802210000030001",
"intro": "AMS-HT C Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806230000020008",
"intro": "AMS-HT G Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800210000020005",
"intro": "AMS-HT A Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "070322000002000A",
"intro": "Failed to adjust the filament position of AMS D Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0704700000020012",
"intro": "AMS E Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "1802700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1801220000020009",
"intro": "Failed to extrude AMS-HT B Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1804700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0704220000020009",
"intro": "Failed to extrude AMS E Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1803700000020023",
"intro": "AMS-HT D Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1805700000020043",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1806700000020031",
"intro": "AMS-HT G Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1807700000020013",
"intro": "AMS-HT H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "05FE040000020042",
"intro": "Nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "0707350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "070220000002000A",
"intro": "Failed to adjust the filament position of AMS C Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1801700000020032",
"intro": "AMS-HT B Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1804700000020040",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1806700000020012",
"intro": "AMS-HT G Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "1805700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1801700000020031",
"intro": "AMS-HT B Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0705210000020009",
"intro": "Failed to extrude AMS F Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0704700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1803700000020031",
"intro": "AMS-HT D Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1806310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1802700000020020",
"intro": "AMS-HT C filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0705700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0705700000020060",
"intro": "AMS F Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "070320000002000A",
"intro": "Failed to adjust the filament position of AMS D Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1805310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0700200000020002",
"intro": "AMS A Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0700220000020004",
"intro": "AMS A Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0700700000020031",
"intro": "AMS A Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0700700000020045",
"intro": "AMS A Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0702130000010001",
"intro": "The AMS C slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0702220000020003",
"intro": "AMS C Slot 3's filament may be broken in AMS."
},
{
"ecode": "0703220000020004",
"intro": "AMS D Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0703230000020001",
"intro": "AMS D Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0703230000020004",
"intro": "AMS D Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0703700000020042",
"intro": "AMS D Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0703700000020021",
"intro": "AMS D Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "0300950000010007",
"intro": "The engraving laser module is abnormal; the laser may have an open circuit or may be damaged."
},
{
"ecode": "0300990000010002",
"intro": "The right side window Hall sensor 1 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "1805220000030002",
"intro": "AMS-HT F Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0704210000030002",
"intro": "AMS E Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1802220000020002",
"intro": "AMS-HT C Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1802220000020004",
"intro": "AMS-HT C Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0707100000010003",
"intro": "The AMS H slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705200000020008",
"intro": "AMS F Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705200000020004",
"intro": "AMS F Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0706550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1803230000020001",
"intro": "AMS-HT D Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "1806100000010003",
"intro": "The AMS-HT G slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1801220000020002",
"intro": "AMS-HT B Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1807210000030002",
"intro": "AMS-HT H Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0705210000020004",
"intro": "AMS F Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0704200000020004",
"intro": "AMS E Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1800120000010001",
"intro": "The AMS-HT A slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0707210000020002",
"intro": "AMS H Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0704220000030001",
"intro": "AMS E Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1804550000010003",
"intro": "AMS-HT E was detected offline during the AMS initialization process."
},
{
"ecode": "0704550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1805230000020005",
"intro": "AMS-HT F Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804210000020002",
"intro": "AMS-HT E Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0707550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1806130000020002",
"intro": "The AMS-HT G slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1807210000020008",
"intro": "AMS-HT H Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704230000030002",
"intro": "AMS E Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0704130000010001",
"intro": "The AMS E slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "07FF800000020003",
"intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate."
},
{
"ecode": "1804700000020060",
"intro": "AMS-HT E Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0705700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0705700000020046",
"intro": "AMS F Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "1801310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "180420000002000A",
"intro": "Failed to adjust the filament position of AMS-HT E Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1801200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "180123000002000A",
"intro": "Failed to adjust the filament position of AMS-HT B Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1807700000020011",
"intro": "AMS-HT H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1805700000020045",
"intro": "AMS-HT F Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1801700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1805700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0704700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "1807700000020043",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "18FE800000010003",
"intro": "The toolhead lift motor position hall signal is abnormal during extruder switching."
},
{
"ecode": "0704350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1806700000020023",
"intro": "AMS-HT G Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1802700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1804700000020010",
"intro": "AMS-HT E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1805200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "070622000002000A",
"intro": "Failed to adjust the filament position of AMS G Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "180323000002000A",
"intro": "Failed to adjust the filament position of AMS-HT D Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "180821000002000A",
"intro": "Failed to adjust the filament position of AMS-HT undefined Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1807700000020020",
"intro": "AMS-HT H filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0704700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1805700000020031",
"intro": "AMS-HT F Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "180822000002000A",
"intro": "Failed to adjust the filament position of AMS-HT undefined Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1805700000020060",
"intro": "AMS-HT F Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "0705200000020009",
"intro": "Failed to extrude AMS F Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1807700000020021",
"intro": "AMS-HT H Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1804700000020041",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0707700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "1807700000020046",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0700210000020003",
"intro": "AMS A Slot 2's filament may be broken in AMS."
},
{
"ecode": "0700220000020002",
"intro": "AMS A Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0700220000030002",
"intro": "AMS A Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0700700000020041",
"intro": "AMS A Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0700700000020042",
"intro": "AMS A Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0702200000020002",
"intro": "AMS C Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0703210000030001",
"intro": "AMS D Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0701210000020007",
"intro": "AMS B Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300990000010003",
"intro": "The right side window Hall sensor 2 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0C00040000010017",
"intro": "Print-then-cut did not detect the marker; please repaste the material to be cut."
},
{
"ecode": "0704220000020002",
"intro": "AMS E Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1807130000010003",
"intro": "The AMS-HT H slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1800560000030001",
"intro": "AMS-HT A is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1803110000010001",
"intro": "The AMS-HT D slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1805970000030001",
"intro": "AMS-HT F chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1807220000020005",
"intro": "AMS-HT H Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804200000020002",
"intro": "AMS-HT E Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1806230000020007",
"intro": "AMS-HT G Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704210000030001",
"intro": "AMS E Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1802210000020002",
"intro": "AMS-HT C Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1801230000020003",
"intro": "AMS-HT B Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "0707560000030001",
"intro": "AMS H is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1806210000020002",
"intro": "AMS-HT G Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1801230000030001",
"intro": "AMS-HT B Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1800110000010003",
"intro": "The AMS-HT A slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1803230000020007",
"intro": "AMS-HT D Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805210000030002",
"intro": "AMS-HT F Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1804220000020003",
"intro": "AMS-HT E Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "1803700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1801310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1803700000020011",
"intro": "AMS-HT D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0707300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0704700000020033",
"intro": "AMS E Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1802700000020043",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0500040000020048",
"intro": "No platform detected; please make sure the laser plate is placed properly."
},
{
"ecode": "1802700000020021",
"intro": "AMS-HT C Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1800700000020042",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1803700000020043",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1804700000020011",
"intro": "AMS-HT E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1803700000020050",
"intro": "AMS-HT D Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1805700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0704200000020009",
"intro": "Failed to extrude AMS E Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1800310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1800700000020022",
"intro": "AMS-HT A Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1802700000020060",
"intro": "AMS-HT C Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "18FF800000020001",
"intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead."
},
{
"ecode": "1804700000020061",
"intro": "AMS-HT E Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1800700000020030",
"intro": "AMS-HT A Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "070523000002000A",
"intro": "Failed to adjust the filament position of AMS F Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "0706700000020032",
"intro": "AMS G Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0706700000020011",
"intro": "AMS G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1801700000020020",
"intro": "AMS-HT B filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "1802350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1807350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "1804700000020032",
"intro": "AMS-HT E Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "1803700000020014",
"intro": "AMS-HT D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0705200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "1804700000020005",
"intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0700110000020002",
"intro": "The AMS A slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700700000020030",
"intro": "AMS A Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0701110000010003",
"intro": "The AMS B slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701220000020001",
"intro": "AMS B Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0701220000020004",
"intro": "AMS B Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0701620000020001",
"intro": "The AMS B Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0701700000020041",
"intro": "AMS B Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0702110000010001",
"intro": "The AMS C slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0702210000020001",
"intro": "AMS C Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0702220000030001",
"intro": "AMS C Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0702230000020001",
"intro": "AMS C Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0702230000020004",
"intro": "AMS C Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0702630000020001",
"intro": "The AMS C Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702700000020014",
"intro": "AMS C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0700200000020008",
"intro": "AMS A Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0703220000020007",
"intro": "AMS D Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0700210000020007",
"intro": "AMS A Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0702700000020012",
"intro": "AMS C Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0703700000020014",
"intro": "AMS D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0703700000020022",
"intro": "AMS D Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0500400000010040",
"intro": "Cutting module Serial Number error"
},
{
"ecode": "0700960000010003",
"intro": "AMS A Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0705220000020007",
"intro": "AMS F Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806230000030002",
"intro": "AMS-HT G Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805210000020003",
"intro": "AMS-HT F Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "0704620000020001",
"intro": "The AMS E Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0707620000020001",
"intro": "The AMS H Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1803210000020002",
"intro": "AMS-HT D Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1805120000010001",
"intro": "The AMS-HT F slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1806110000010001",
"intro": "The AMS-HT G slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0707220000020002",
"intro": "AMS H Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1804100000010003",
"intro": "The AMS-HT E slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806230000020002",
"intro": "AMS-HT G Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1801210000020008",
"intro": "AMS-HT B Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800960000020002",
"intro": "AMS-HT A Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1807550000010003",
"intro": "AMS-HT H was detected offline during the AMS initialization process."
},
{
"ecode": "1803200000020004",
"intro": "AMS-HT D Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1803200000030002",
"intro": "AMS-HT D Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1800230000020008",
"intro": "AMS-HT A Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802230000020008",
"intro": "AMS-HT C Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707200000020005",
"intro": "AMS H Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1802130000010003",
"intro": "The AMS-HT C slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705620000020001",
"intro": "The AMS F Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1802230000020004",
"intro": "AMS-HT C Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0707970000030001",
"intro": "AMS H chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0705210000020003",
"intro": "AMS F Slot 2's filament may be broken in AMS."
},
{
"ecode": "0704230000020008",
"intro": "AMS E Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804110000020002",
"intro": "The AMS-HT E slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0705220000020005",
"intro": "AMS F Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1805220000020007",
"intro": "AMS-HT F Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704230000020004",
"intro": "AMS E Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1801210000020004",
"intro": "AMS-HT B Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1803220000020003",
"intro": "AMS-HT D Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "0702560000030001",
"intro": "AMS C is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1806210000020003",
"intro": "AMS-HT G Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "1805550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "07FF450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "1801700000020011",
"intro": "AMS-HT B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "1800230000020009",
"intro": "Failed to extrude AMS-HT A Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0704700000020042",
"intro": "AMS E Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "070121000002000A",
"intro": "Failed to adjust the filament position of AMS B Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0300930000010006",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air inlet may have an open circuit."
},
{
"ecode": "0500040000020049",
"intro": "The platform type is unknown; please replace it with the correct one and check if the BirdsEye camera is obstructed."
},
{
"ecode": "1803300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0706230000020009",
"intro": "Failed to extrude AMS G Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1804700000020021",
"intro": "AMS-HT E Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1806700000020010",
"intro": "AMS-HT G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "18FE450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "070721000002000A",
"intro": "Failed to adjust the filament position of AMS H Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "0707700000020012",
"intro": "AMS H Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0706700000020045",
"intro": "AMS G Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1806700000020061",
"intro": "AMS-HT G Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1800400000020003",
"intro": "The AMS Hub communication is abnormal; the cable may be not well connected."
},
{
"ecode": "0707200000020009",
"intro": "Failed to extrude AMS H Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1806700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0706200000020009",
"intro": "Failed to extrude AMS G Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "070823000002000A",
"intro": "Failed to adjust the filament position of AMS undefined Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1806700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "1804700000020045",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0500040000020041",
"intro": "The left and right hotend can't be identified, possibly due non-official hotend. It could also be the blocked live view camera or the damaged nozzle marker."
},
{
"ecode": "0707220000020009",
"intro": "Failed to extrude AMS H Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700120000010003",
"intro": "The AMS A slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0700200000020003",
"intro": "AMS A Slot 1's filament may be broken in AMS."
},
{
"ecode": "0700200000030001",
"intro": "AMS A Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0700210000030002",
"intro": "AMS A Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0700220000020005",
"intro": "AMS A Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0700230000020005",
"intro": "AMS A Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0701100000010003",
"intro": "The AMS B slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701120000010001",
"intro": "The AMS B slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0701210000020005",
"intro": "AMS B Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0701220000020002",
"intro": "AMS B Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0701230000030001",
"intro": "AMS B Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0701630000020001",
"intro": "The AMS B Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702100000010001",
"intro": "The AMS C slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0702200000020005",
"intro": "AMS C Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702230000020002",
"intro": "AMS C Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0702610000020001",
"intro": "The AMS C Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0703230000020003",
"intro": "AMS D Slot 4's filament may be broken in AMS."
},
{
"ecode": "0703230000020005",
"intro": "AMS D Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0500060000020008",
"intro": "Too many liveview mipierrs; please check the hardware and line connections."
},
{
"ecode": "0700700000020020",
"intro": "AMS A filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0703230000020007",
"intro": "AMS D Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803560000030001",
"intro": "AMS-HT D is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "0706230000020007",
"intro": "AMS G Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803220000020005",
"intro": "AMS-HT D Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1803110000010003",
"intro": "The AMS-HT D slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806210000020008",
"intro": "AMS-HT G Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705210000020001",
"intro": "AMS F Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1807120000020002",
"intro": "The AMS-HT H slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0705220000030001",
"intro": "AMS F Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806220000020001",
"intro": "AMS-HT G Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0704210000020007",
"intro": "AMS E Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801960000020002",
"intro": "AMS-HT B Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1800200000020007",
"intro": "AMS-HT A Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804120000010003",
"intro": "The AMS-HT E slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1807210000020001",
"intro": "AMS-HT H Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0707960000010003",
"intro": "AMS H Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1802200000020002",
"intro": "AMS-HT C Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1803200000020002",
"intro": "AMS-HT D Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1804220000020005",
"intro": "AMS-HT E Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706220000030002",
"intro": "AMS G Slot 3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805130000020002",
"intro": "The AMS-HT F slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1804230000020004",
"intro": "AMS-HT E Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0706220000020007",
"intro": "AMS G Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804200000020007",
"intro": "AMS-HT E Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707230000020004",
"intro": "AMS H Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0706230000020001",
"intro": "AMS G Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0704120000010003",
"intro": "The AMS E slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1803230000020005",
"intro": "AMS-HT D Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1806220000030001",
"intro": "AMS-HT G Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0707210000020005",
"intro": "AMS H Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1806620000020001",
"intro": "The AMS-HT G Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1807220000020009",
"intro": "Failed to extrude AMS-HT H Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1801700000020042",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0706700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "070420000002000A",
"intro": "Failed to adjust the filament position of AMS E Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1804700000020033",
"intro": "AMS-HT E Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1801700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0707300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0707700000020046",
"intro": "AMS H Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "18FE200000020001",
"intro": "External filament of left extruder has run out; please load a new filament."
},
{
"ecode": "0C00010000010010",
"intro": "The Live View Camera calibration failed. Please check if the heatbed is clear and ensure the camera image is clear and dirt-free. After these steps, please recalibrate."
},
{
"ecode": "1802700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "05FF040000020042",
"intro": "Nozzle mismatch was detected during printing. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high."
},
{
"ecode": "1801700000020014",
"intro": "AMS-HT B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "1803230000020009",
"intro": "Failed to extrude AMS-HT D Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0705700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1802700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1800700000020033",
"intro": "AMS-HT A Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "0704700000020046",
"intro": "AMS E Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0705310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0707700000020013",
"intro": "AMS H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1800700000020061",
"intro": "AMS-HT A Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1803700000020046",
"intro": "AMS-HT D Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0300260000000000",
"intro": ""
},
{
"ecode": "0705700000020043",
"intro": "AMS F Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0700220000020003",
"intro": "AMS A Slot 3's filament may be broken in AMS."
},
{
"ecode": "0701120000010003",
"intro": "The AMS B slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701700000020044",
"intro": "AMS B Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0701700000020050",
"intro": "AMS B Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0702120000020002",
"intro": "The AMS C slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702220000020001",
"intro": "AMS C Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "0702230000020003",
"intro": "AMS C Slot 4's filament may be broken in AMS."
},
{
"ecode": "0702700000020031",
"intro": "AMS C Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0703210000020001",
"intro": "AMS D Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0703610000020001",
"intro": "The AMS D Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0700970000030001",
"intro": "AMS A chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0705230000020004",
"intro": "AMS F Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1801210000020001",
"intro": "AMS-HT B Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1801110000010001",
"intro": "The AMS-HT B slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1801200000020003",
"intro": "AMS-HT B Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "1805110000010001",
"intro": "The AMS-HT F slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0704130000010003",
"intro": "The AMS E slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1802130000020002",
"intro": "The AMS-HT C slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0706100000020002",
"intro": "The AMS G slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802200000020005",
"intro": "AMS-HT C Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0704210000020004",
"intro": "AMS E Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0706220000020005",
"intro": "AMS G Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0706210000020003",
"intro": "AMS G Slot 2's filament may be broken in AMS."
},
{
"ecode": "0704200000020001",
"intro": "AMS E Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "1801230000030002",
"intro": "AMS-HT B Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0706220000020008",
"intro": "AMS G Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806230000020004",
"intro": "AMS-HT G Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1802230000030002",
"intro": "AMS-HT C Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0707630000020001",
"intro": "The AMS H Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1804210000020004",
"intro": "AMS-HT E Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1800220000020002",
"intro": "AMS-HT A Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1800200000020004",
"intro": "AMS-HT A Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1800960000010003",
"intro": "AMS-HT A Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1806550000010003",
"intro": "AMS-HT G was detected offline during the AMS initialization process."
},
{
"ecode": "1806120000010001",
"intro": "The AMS-HT G slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0707110000020002",
"intro": "The AMS H slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1806200000020007",
"intro": "AMS-HT G Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803100000010003",
"intro": "The AMS-HT D slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806130000010003",
"intro": "The AMS-HT G slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1806200000020008",
"intro": "AMS-HT G Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707200000020003",
"intro": "AMS H Slot 1's filament may be broken in AMS."
},
{
"ecode": "0707220000020008",
"intro": "AMS H Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803100000010001",
"intro": "The AMS-HT D slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0706120000010001",
"intro": "The AMS G slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0700220000020008",
"intro": "AMS A Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704230000020001",
"intro": "AMS E Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "1804230000020002",
"intro": "AMS-HT E Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0706210000020007",
"intro": "AMS G Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0703220000020008",
"intro": "AMS D Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706700000020044",
"intro": "AMS G Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "1806700000020022",
"intro": "AMS-HT G Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1801210000020009",
"intro": "Failed to extrude AMS-HT B Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "18FF800000020003",
"intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate."
},
{
"ecode": "1803700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "1803700000020033",
"intro": "AMS-HT D Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "180122000002000A",
"intro": "Failed to adjust the filament position of AMS-HT B Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1804700000020020",
"intro": "AMS-HT E filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "070221000002000A",
"intro": "Failed to adjust the filament position of AMS C Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "070323000002000A",
"intro": "Failed to adjust the filament position of AMS D Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1805700000020011",
"intro": "AMS-HT F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0707210000020009",
"intro": "Failed to extrude AMS H Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1805700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "1801700000020045",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "0706310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0704700000020041",
"intro": "AMS E Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "1800200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "0704700000020032",
"intro": "AMS E Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "070422000002000A",
"intro": "Failed to adjust the filament position of AMS E Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0300D00000010003",
"intro": "The cutting module cable has come loose; please check the cable connection."
},
{
"ecode": "1807700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0C00030000020013",
"intro": "Foreign object detection is not working. Please restart the devices or update the firmware."
},
{
"ecode": "1806700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0705300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1802230000020009",
"intro": "Failed to extrude AMS-HT C Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700100000010003",
"intro": "The AMS A slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0700200000020005",
"intro": "AMS A Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0700210000020001",
"intro": "AMS A Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0700630000020001",
"intro": "The AMS A Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702220000020005",
"intro": "AMS C Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702700000020041",
"intro": "AMS C Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0703100000010003",
"intro": "The AMS D slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0703200000020003",
"intro": "AMS D Slot 1's filament may be broken in AMS."
},
{
"ecode": "0703220000020005",
"intro": "AMS D Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0703700000020044",
"intro": "AMS D Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0701700000020022",
"intro": "AMS B Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0703700000020012",
"intro": "AMS D Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0701700000020010",
"intro": "AMS B Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1804210000020007",
"intro": "AMS-HT E Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802210000020008",
"intro": "AMS-HT C Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1804220000020001",
"intro": "AMS-HT E Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1800130000010001",
"intro": "The AMS-HT A slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0706620000020001",
"intro": "The AMS G Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1803550000010003",
"intro": "AMS-HT D was detected offline during the AMS initialization process."
},
{
"ecode": "0705230000020002",
"intro": "AMS F Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1806200000020004",
"intro": "AMS-HT G Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1803220000020004",
"intro": "AMS-HT D Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1800970000030001",
"intro": "AMS-HT A chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1807970000030001",
"intro": "AMS-HT H chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1800210000020004",
"intro": "AMS-HT A Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0704200000020002",
"intro": "AMS E Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1805200000020002",
"intro": "AMS-HT F Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1803970000030001",
"intro": "AMS-HT D chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1802230000020002",
"intro": "AMS-HT C Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1805230000020008",
"intro": "AMS-HT F Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800210000020002",
"intro": "AMS-HT A Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1807210000030001",
"intro": "AMS-HT H Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1805220000020001",
"intro": "AMS-HT F Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1807130000020002",
"intro": "The AMS-HT H slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804230000020003",
"intro": "AMS-HT E Slot 4's filament may be broken in AMS-HT."
},
{
"ecode": "1802200000020007",
"intro": "AMS-HT C Slot 1 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706700000020014",
"intro": "AMS G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0705700000020022",
"intro": "AMS F Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "1807700000020023",
"intro": "AMS-HT H Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1802220000020009",
"intro": "Failed to extrude AMS-HT C Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0704700000020050",
"intro": "AMS E Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1802700000020022",
"intro": "AMS-HT C Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "050004000002004B",
"intro": "The platform type does not match; please place a cutting mat."
},
{
"ecode": "1800700000020013",
"intro": "AMS-HT A Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1806700000020033",
"intro": "AMS-HT G Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "18FF200000020001",
"intro": "External filament of right extruder has run out; please load a new filament."
},
{
"ecode": "0707700000020060",
"intro": "AMS H Assisting extruder grab filament failed; this might be due to the assist motor slipping. Please trim off the worn section of the filament."
},
{
"ecode": "050004000002004E",
"intro": "Incorrect platform type. Please place the cutting platform for laser calibration."
},
{
"ecode": "1800700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "05FF040000020041",
"intro": "The right hotend can't be identified, possibly due non-official hotend. It could also be the blocked live view camera or the damaged nozzle marker."
},
{
"ecode": "1800400000020002",
"intro": "The filament buffer position signal error: the position sensor may be malfunctioning."
},
{
"ecode": "1804700000020042",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0300250000000000",
"intro": ""
},
{
"ecode": "0704700000020040",
"intro": "AMS E Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0706700000020042",
"intro": "AMS G Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "18FF800000010001",
"intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "1802700000020042",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1804700000020012",
"intro": "AMS-HT E Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "03009B0000010003",
"intro": "Emergency stop button is not properly installed; please install correctly as guided."
},
{
"ecode": "0500040000020046",
"intro": "No material detected; please confirm placement before continuing."
},
{
"ecode": "180521000002000A",
"intro": "Failed to adjust the filament position of AMS-HT F Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1806700000020013",
"intro": "AMS-HT G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1804700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1801700000020061",
"intro": "AMS-HT B Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1807700000020031",
"intro": "AMS-HT H Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "18FE450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "0700100000010001",
"intro": "The AMS A slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0700210000020004",
"intro": "AMS A Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0700210000030001",
"intro": "AMS A Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0700700000020032",
"intro": "AMS A Feeding filament to the tool head extruder has failed; this might be due to excessive resistance from the filament. Please check if the filament spool is tilted or if the filament tube is obstructed."
},
{
"ecode": "0701230000020001",
"intro": "AMS B Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0701700000020030",
"intro": "AMS B Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "0703100000020002",
"intro": "The AMS D slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0703120000020002",
"intro": "The AMS D slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0703210000020004",
"intro": "AMS D Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0703630000020001",
"intro": "The AMS D Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0702700000020021",
"intro": "AMS C Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "07FE200000020002",
"intro": "No filament was detected in the left extruder from the external spool; please load the new filament."
},
{
"ecode": "0300C20000010002",
"intro": "Hall sensor of Filter Switch Flap malfunction: please check if the wiring is loose."
},
{
"ecode": "1801210000020005",
"intro": "AMS-HT B Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0700560000030001",
"intro": "AMS A is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1803630000020001",
"intro": "The AMS-HT D Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1803230000020002",
"intro": "AMS-HT D Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1806610000020001",
"intro": "The AMS-HT G Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0300260000010002",
"intro": "The sensitivity of the left extruder extrusion force sensor is low; the nozzle may not installed correctly."
},
{
"ecode": "1807210000020002",
"intro": "AMS-HT H Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1805230000020007",
"intro": "AMS-HT F Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802100000010001",
"intro": "The AMS-HT C slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802120000010003",
"intro": "The AMS-HT C slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0703560000030001",
"intro": "AMS D is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1806210000020004",
"intro": "AMS-HT G Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1804220000020004",
"intro": "AMS-HT E Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1803210000030002",
"intro": "AMS-HT D Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1802220000020007",
"intro": "AMS-HT C Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706110000010003",
"intro": "The AMS G slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0707100000020002",
"intro": "The AMS H slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0705230000030002",
"intro": "AMS F Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0705960000020002",
"intro": "AMS F Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "0707110000010003",
"intro": "The AMS H slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1804200000030002",
"intro": "AMS-HT E Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1800210000030001",
"intro": "AMS-HT A Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1807230000030002",
"intro": "AMS-HT H Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805110000020002",
"intro": "The AMS-HT F slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1807200000020008",
"intro": "AMS-HT H Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806700000020046",
"intro": "AMS-HT G Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "070620000002000A",
"intro": "Failed to adjust the filament position of AMS G Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1807230000020009",
"intro": "Failed to extrude AMS-HT H Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0C00010000010012",
"intro": "The Live View Cameracalibration failed and the calibration result could not be saved. Please try recalibrating. If calibration fails multiple times, please contact the customer support team."
},
{
"ecode": "050004000002004F",
"intro": "Incorrect platform type. Please place the cutting platform for cutting calibration."
},
{
"ecode": "1803220000020009",
"intro": "Failed to extrude AMS-HT D Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1803700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1805700000020021",
"intro": "AMS-HT F Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "07FE450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "1804700000020013",
"intro": "AMS-HT E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "1800700000020021",
"intro": "AMS-HT A Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "0707700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0707700000020043",
"intro": "AMS H Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1800700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0707700000020050",
"intro": "AMS H Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0704300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1807700000020022",
"intro": "AMS-HT H Feeding filament to the buffer has failed; this might be due to worn filament causing the assist motor to slip. Please trim off the worn-out section of the filament."
},
{
"ecode": "0707700000020061",
"intro": "AMS H Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "070321000002000A",
"intro": "Failed to adjust the filament position of AMS D Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "070623000002000A",
"intro": "Failed to adjust the filament position of AMS G Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1804700000020014",
"intro": "AMS-HT E Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0705700000020033",
"intro": "AMS F Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "050004000002004C",
"intro": "Unknown type of cutting protection base; please replace with the correct cutting protection base and check if the Live-view camera is obstructed."
},
{
"ecode": "1800700000020044",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0707700000020021",
"intro": "AMS H Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "1801350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "180023000002000A",
"intro": "Failed to adjust the filament position of AMS-HT A Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "18FF200000020002",
"intro": "No filament was detected in the right extruder from the external spool; please load the new filament."
},
{
"ecode": "0700230000020002",
"intro": "AMS A Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0701210000020002",
"intro": "AMS B Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0701210000020004",
"intro": "AMS B Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0701700000020040",
"intro": "AMS B Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "0701700000020042",
"intro": "AMS B Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "0702210000020004",
"intro": "AMS C Slot 2 filament may be broken in the tool head."
},
{
"ecode": "0702230000030002",
"intro": "AMS C Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0702700000020043",
"intro": "AMS C Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0703700000020031",
"intro": "AMS D Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1203300000010004",
"intro": "RFID cannot be read because of an encryption chip failure in AMS D."
},
{
"ecode": "0702210000020007",
"intro": "AMS C Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0500400000010039",
"intro": "Laser module Serial Number error"
},
{
"ecode": "07FE800000020002",
"intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model."
},
{
"ecode": "0300290000010001",
"intro": "Encoder pattern can not be recognized; possible reasons include: pattern distortion, light overexposure, plate misplacement..."
},
{
"ecode": "1807200000020005",
"intro": "AMS-HT H Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0707210000030002",
"intro": "AMS H Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1806110000010003",
"intro": "The AMS-HT G slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1802200000020004",
"intro": "AMS-HT C Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1805220000020002",
"intro": "AMS-HT F Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0701210000020008",
"intro": "AMS B Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704960000010003",
"intro": "AMS E Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1806220000020002",
"intro": "AMS-HT G Slot 3 is empty; please insert a new filament."
},
{
"ecode": "0706970000030001",
"intro": "AMS G chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "1804200000020008",
"intro": "AMS-HT E Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704130000020002",
"intro": "The AMS E slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0703230000020008",
"intro": "AMS D Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0700230000020008",
"intro": "AMS A Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704100000010001",
"intro": "The AMS E slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1805960000020002",
"intro": "AMS-HT F Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "0701560000030001",
"intro": "AMS B is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "0707120000010001",
"intro": "The AMS H slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1806210000020007",
"intro": "AMS-HT G Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800130000010003",
"intro": "The AMS-HT A slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1805210000020001",
"intro": "AMS-HT F Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "0705960000010003",
"intro": "AMS F Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "1801230000020007",
"intro": "AMS-HT B Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705230000020003",
"intro": "AMS F Slot 4's filament may be broken in AMS."
},
{
"ecode": "1803610000020001",
"intro": "The AMS-HT D Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1807220000020003",
"intro": "AMS-HT H Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "1805560000030001",
"intro": "AMS-HT F is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1800200000020003",
"intro": "AMS-HT A Slot 1's filament may be broken in AMS-HT."
},
{
"ecode": "0705200000030001",
"intro": "AMS F Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1807630000020001",
"intro": "The AMS-HT H Slot 4 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1806230000020001",
"intro": "AMS-HT G Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0705110000020002",
"intro": "The AMS F slot 2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804200000020005",
"intro": "AMS-HT E Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0705100000010001",
"intro": "The AMS F slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807210000020004",
"intro": "AMS-HT H Slot 2 filament may be broken in the tool head."
},
{
"ecode": "180720000002000A",
"intro": "Failed to adjust the filament position of AMS-HT H Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "1806210000020009",
"intro": "Failed to extrude AMS-HT G Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "050001000002000A",
"intro": "BirdsEye camera is not certified, and camera-related functions are invalid."
},
{
"ecode": "18FE800000020003",
"intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate."
},
{
"ecode": "1800700000020023",
"intro": "AMS-HT A Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1802700000020033",
"intro": "AMS-HT C Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "1807200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "03009D0000020002",
"intro": "The engrave laser focal point XY calibration result differs significantly from the design values; please re-install the Laser Module and re-run the Laser Module Begin Setup."
},
{
"ecode": "0C00010000020014",
"intro": "Nozzle camera is malfunctioning. If this issue occurs multiple times during printing, please contact customer service."
},
{
"ecode": "1800700000020043",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0300180000000000",
"intro": ""
},
{
"ecode": "0C00030000020016",
"intro": "Foreign object detection is not working and the Liveview camera serial number cannot be read. Please contact the customer support team."
},
{
"ecode": "1805300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1805700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "1806300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "070122000002000A",
"intro": "Failed to adjust the filament position of AMS B Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "18FF810000010002",
"intro": "The position hall sensor of the extruder switching motor is abnormal. Please check whether the connecting cable is loose."
},
{
"ecode": "1801700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0707310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1802700000020046",
"intro": "AMS-HT C Pulling out filament has failed; this might be due to excessive resistance in the assist motor. Please check if the filament spool is tilted or deformed, and if the filament tube is clear."
},
{
"ecode": "0706700000020043",
"intro": "AMS G Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "1801700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "070123000002000A",
"intro": "Failed to adjust the filament position of AMS B Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020011",
"intro": "AMS F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a disconnection of the DC motor. Please check the connection of the DC motor plug."
},
{
"ecode": "0707700000020014",
"intro": "AMS H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a small piece of broken filament entering the feed tube. Please remove the broken filament from the feed tube."
},
{
"ecode": "0700130000010001",
"intro": "The AMS A slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0700210000020005",
"intro": "AMS A Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0700700000020033",
"intro": "AMS A Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "0701110000010001",
"intro": "The AMS B slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0702120000010001",
"intro": "The AMS C slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0703700000020043",
"intro": "AMS D Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0702700000020020",
"intro": "AMS C filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "0702700000020013",
"intro": "AMS C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "0300250000010004",
"intro": "The signal of the extrusion force sensor of the right extruder is abnormal. The sensor may be damaged or the MC-TH communication may be abnormal."
},
{
"ecode": "0300260000010008",
"intro": "The left nozzle touches the heating bed abnormally. Please check whether there is filament residue on the nozzle or foreign matter where the nozzle touches the bed."
},
{
"ecode": "0702960000010003",
"intro": "AMS C Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0705210000030002",
"intro": "AMS F Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0703550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "0704220000020005",
"intro": "AMS E Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0702550000010002",
"intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder."
},
{
"ecode": "1807200000020002",
"intro": "AMS-HT H Slot 1 is empty; please insert a new filament."
},
{
"ecode": "0707130000010003",
"intro": "The AMS H slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0704210000020002",
"intro": "AMS E Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0707220000020001",
"intro": "AMS H Slot 3 filament has run out. Please insert a new filament."
},
{
"ecode": "1803220000020008",
"intro": "AMS-HT D Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706200000030002",
"intro": "AMS G Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1804130000010001",
"intro": "The AMS-HT E slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1802210000020005",
"intro": "AMS-HT C Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1806220000020005",
"intro": "AMS-HT G Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0705230000020005",
"intro": "AMS F Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804960000020002",
"intro": "AMS-HT E Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1800210000020001",
"intro": "AMS-HT A Slot 2 filament has run out. Please insert a new filament."
},
{
"ecode": "1802220000020003",
"intro": "AMS-HT C Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "0704210000020003",
"intro": "AMS E Slot 2's filament may be broken in AMS."
},
{
"ecode": "1806220000020004",
"intro": "AMS-HT G Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0707230000020007",
"intro": "AMS H Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706200000020004",
"intro": "AMS G Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1805220000030001",
"intro": "AMS-HT F Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0706120000020002",
"intro": "The AMS G slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1800120000010003",
"intro": "The AMS-HT A slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705230000020007",
"intro": "AMS F Slot 4 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802110000010003",
"intro": "The AMS-HT C slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1801960000010003",
"intro": "AMS-HT B Unable to start drying; please pull out the filament from filament hub and try again."
},
{
"ecode": "0704200000030001",
"intro": "AMS E Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1807220000020004",
"intro": "AMS-HT H Slot 3 filament may be broken in the tool head."
},
{
"ecode": "0707210000020004",
"intro": "AMS H Slot 2 filament may be broken in the tool head."
},
{
"ecode": "1803220000020007",
"intro": "AMS-HT D Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800230000020001",
"intro": "AMS-HT A Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "1801220000020003",
"intro": "AMS-HT B Slot 3's filament may be broken in AMS-HT."
},
{
"ecode": "0706700000020033",
"intro": "AMS G Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "0706700000020040",
"intro": "AMS G Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1800550000020001",
"intro": "New AMS-HT connected; please set up before use."
},
{
"ecode": "0705700000020041",
"intro": "AMS F Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "18FF800000010002",
"intro": "The toolhead lift motor position hall sensor is abnormal, please check whether the connecting cable is loose."
},
{
"ecode": "1802700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "180020000002000A",
"intro": "Failed to adjust the filament position of AMS-HT A Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0706700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1802700000020010",
"intro": "AMS-HT C Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0707700000020010",
"intro": "AMS H Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "1807700000020061",
"intro": "AMS-HT H Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1802700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "180120000002000A",
"intro": "Failed to adjust the filament position of AMS-HT B Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "0706700000020041",
"intro": "AMS G Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "1805700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "070820000002000A",
"intro": "Failed to adjust the filament position of AMS undefined Slot 1. The filament or buffer may be stuck."
},
{
"ecode": "18FE200000020004",
"intro": "Please pull the external filament from the left extruder."
},
{
"ecode": "1801700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0706700000020013",
"intro": "AMS G Feeding filament to the assist motor extrusion wheel has failed. This might be due to a lost signal from the odometer wheel. Please check the connection of the odometer wheel plug."
},
{
"ecode": "0707700000020041",
"intro": "AMS H Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "180322000002000A",
"intro": "Failed to adjust the filament position of AMS-HT D Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1803700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0707700000020042",
"intro": "AMS H Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "180321000002000A",
"intro": "Failed to adjust the filament position of AMS-HT D Slot 2. The filament or buffer may be stuck."
},
{
"ecode": "1800700000020040",
"intro": "AMS-HT A Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1800400000020001",
"intro": "The filament buffer position signal lost: the cable or position sensor may be malfunctioning."
},
{
"ecode": "1806700000020050",
"intro": "AMS-HT G Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "0707700000020023",
"intro": "AMS H Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1804700000020030",
"intro": "AMS-HT E Feeding filament to the tool head extruder has failed; this might be due to the filament being blocked at the tool head entrance. Please check the tool head filament tube plug."
},
{
"ecode": "1807700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "1805350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0705700000020023",
"intro": "AMS F Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1806700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0700120000020002",
"intro": "The AMS A slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700130000020002",
"intro": "The AMS A slot 4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700220000030001",
"intro": "AMS A Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0700230000020001",
"intro": "AMS A Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "0700230000020004",
"intro": "AMS A Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0701200000020004",
"intro": "AMS B Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0701200000030002",
"intro": "AMS B Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0701210000030002",
"intro": "AMS B Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0701220000020003",
"intro": "AMS B Slot 3's filament may be broken in AMS."
},
{
"ecode": "0701230000020004",
"intro": "AMS B Slot 4 filament may be broken in the tool head."
},
{
"ecode": "0702700000020033",
"intro": "AMS C Feeding filament to the tool head extruder has failed; this might be due to the filament slipping out. Please check if the filament tube is disconnected or if the tube has been worn through."
},
{
"ecode": "0703230000030002",
"intro": "AMS D Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0300250000010001",
"intro": "The frequency of the extrusion force sensor of the right extruder is too low. The nozzle may not be installed or the nozzle heat sink may be too far away from the sensor."
},
{
"ecode": "0703700000020010",
"intro": "AMS D Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "0701700000020021",
"intro": "AMS B Feeding filament feeding to the buffer has failed; this might be due to excessive resistance in the filament. Please check if the filament spool is tilted or if the PTFE tube is blocked."
},
{
"ecode": "0500010000030006",
"intro": "The USB drive is not formatted; please format the USB drive."
},
{
"ecode": "0500010000030004",
"intro": "Not enough space on the USB flash drive; please clear some space."
},
{
"ecode": "1805200000020005",
"intro": "AMS-HT F Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1803100000020002",
"intro": "The AMS-HT D slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0707220000020004",
"intro": "AMS H Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1802100000020002",
"intro": "The AMS-HT C slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0705230000020008",
"intro": "AMS F Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706560000030001",
"intro": "AMS G is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1806230000030001",
"intro": "AMS-HT G Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1806230000020005",
"intro": "AMS-HT G Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1800210000030002",
"intro": "AMS-HT A Slot 2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1805200000020004",
"intro": "AMS-HT F Slot 1 filament may be broken in the tool head."
},
{
"ecode": "1801220000030001",
"intro": "AMS-HT B Slot 3 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0707230000020005",
"intro": "AMS H Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "1804620000020001",
"intro": "The AMS-HT E Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1805210000020002",
"intro": "AMS-HT F Slot 2 is empty; please insert a new filament."
},
{
"ecode": "0705600000020001",
"intro": "The AMS F Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0705120000010001",
"intro": "The AMS F slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1807100000020002",
"intro": "The AMS-HT H slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0706210000030001",
"intro": "AMS G Slot 2 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "1801220000020005",
"intro": "AMS-HT B Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0705110000010003",
"intro": "The AMS F slot 2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0707120000010003",
"intro": "The AMS H slot 3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1802210000020007",
"intro": "AMS-HT C Slot 2 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801560000030001",
"intro": "AMS-HT B is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1802960000020002",
"intro": "AMS-HT C Environmental temperature is too low, which will affect the drying capability."
},
{
"ecode": "1806560000030001",
"intro": "AMS-HT G is undergoing dry cooling; please wait for it to cool down before operating."
},
{
"ecode": "1801200000030002",
"intro": "AMS-HT B Slot 1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0705230000030001",
"intro": "AMS F Slot 4 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0704100000010003",
"intro": "The AMS E slot 1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "18FE800000020001",
"intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead."
},
{
"ecode": "070723000002000A",
"intro": "Failed to adjust the filament position of AMS H Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "1800700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0704310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0705700000020050",
"intro": "AMS F Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1806700000020020",
"intro": "AMS-HT G filament feeding to the buffer has failed; this might be due to the buffer blocking the filament. Please check the buffer PTFE tube plug."
},
{
"ecode": "1805700000020050",
"intro": "AMS-HT F Loading filament into the buffer has failed; this might be due to excessive resistance in the buffer. Please check if the buffer is jammed, the filament spool is tilted, or the filament tube is blocked."
},
{
"ecode": "1800700000020007",
"intro": "AMS-HT filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0704700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0705700000020045",
"intro": "AMS F Pulling out filament has failed; this might be due to filament running out or being pulled out."
},
{
"ecode": "1801700000020040",
"intro": "AMS-HT B Pulling out filament has failed; this might be due to excessive resistance in the DC motor. Please check if the filament spool is tilted or deformed or if the filament tube is blocked."
},
{
"ecode": "1806700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "050004000002004A",
"intro": "The platform type does not match; please place a laser platform."
},
{
"ecode": "180222000002000A",
"intro": "Failed to adjust the filament position of AMS-HT C Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "1802200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS-HT to extruder"
},
{
"ecode": "0707700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "070223000002000A",
"intro": "Failed to adjust the filament position of AMS C Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "180522000002000A",
"intro": "Failed to adjust the filament position of AMS-HT F Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0500040000020043",
"intro": "No print plate detected; please make sure it is placed correctly."
},
{
"ecode": "18FE810000010001",
"intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "1807700000020042",
"intro": "AMS-HT H Pulling out filament has failed; this might be due to the DC motor losing connection. Please check the DC motor plug to ensure it is properly connected."
},
{
"ecode": "1804300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0705700000020010",
"intro": "AMS F Feeding filament to the assist motor extrusion wheel has failed. This might be due to a blockage in the feed tube. Please check if the feed tube and the filament hub are clear."
},
{
"ecode": "03009D0000020003",
"intro": "The engrave laser focal point Z calibration result differs significantly from the design values; please re-install the Laser Module and re-run the Laser Module Begin Setup."
},
{
"ecode": "1805700000020023",
"intro": "AMS-HT F Feeding filament to the buffer has failed; this might be due to the filament coming detached. Please check if the filament tube is improperly connected or if the tube has been worn through."
},
{
"ecode": "1804700000020044",
"intro": "AMS-HT E Pulling out filament has failed; this might be due to broken filament in the tool head. Please remove the broken filament."
},
{
"ecode": "0705700000020012",
"intro": "AMS F Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "070722000002000A",
"intro": "Failed to adjust the filament position of AMS H Slot 3. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "070023000002000A",
"intro": "Failed to adjust the filament position of AMS A Slot 4. The filament or buffer may be stuck."
},
{
"ecode": "0705700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0705700000020031",
"intro": "AMS F Feeding filament to the tool head extruder has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0700620000020001",
"intro": "The AMS A Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0700700000020043",
"intro": "AMS A Pulling out filament has failed; this might be due to the filament wearing out and causing the assist motor to slip. Please trim off the worn section of the filament."
},
{
"ecode": "0702130000010003",
"intro": "The AMS C slot 4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0702200000020001",
"intro": "AMS C Slot 1 filament has run out. Please insert a new filament."
},
{
"ecode": "0703600000020001",
"intro": "The AMS D Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0703700000020041",
"intro": "AMS D Pulling out filament has failed; this might be due to the filament detaching from the spool. Please replace the spool with a new one."
},
{
"ecode": "0700700000020012",
"intro": "AMS A Feeding filament to the assist motor extrusion wheel has failed. This might be due to excessive resistance in the filament. Please check if the spool is tilted, the filament is tangled, or the spool rotation is not smooth."
},
{
"ecode": "0300180000010006",
"intro": "The heatbed leveling data is abnormal. Please check whether there are any foreign objects on the heatbed and Z slider. If so, please remove them and try again."
},
{
"ecode": "0703970000030001",
"intro": "AMS D chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed."
},
{
"ecode": "0704100000020002",
"intro": "The AMS E slot 1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1801200000020004",
"intro": "AMS-HT B Slot 1 filament may be broken in the tool head."
},
{
"ecode": "0705200000020005",
"intro": "AMS F Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head."
},
{
"ecode": "0707230000020001",
"intro": "AMS H Slot 4 filament has run out. Please insert a new filament."
},
{
"ecode": "1802210000020003",
"intro": "AMS-HT C Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "1801620000020001",
"intro": "The AMS-HT B Slot 3 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1805610000020001",
"intro": "The AMS-HT F Slot 2 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "0704230000020003",
"intro": "AMS E Slot 4's filament may be broken in AMS."
},
{
"ecode": "0707210000020008",
"intro": "AMS H Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801220000020007",
"intro": "AMS-HT B Slot 3 feed-out Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807210000020003",
"intro": "AMS-HT H Slot 2's filament may be broken in AMS-HT."
},
{
"ecode": "0707120000020002",
"intro": "The AMS H slot 3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0704220000020004",
"intro": "AMS E Slot 3 filament may be broken in the tool head."
},
{
"ecode": "1805230000030002",
"intro": "AMS-HT F Slot 4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "0704220000020008",
"intro": "AMS E Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706600000020001",
"intro": "The AMS G Slot 1 is overloaded. The filament may be tangled or the spool may be stuck."
},
{
"ecode": "1803230000020004",
"intro": "AMS-HT D Slot 4 filament may be broken in the tool head."
},
{
"ecode": "1803200000030001",
"intro": "AMS-HT D Slot 1 filament has run out. Please wait while old filament is purged."
},
{
"ecode": "0707230000020003",
"intro": "AMS H Slot 4's filament may be broken in AMS."
},
{
"ecode": "0707200000020008",
"intro": "AMS H Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "1806700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS-HT. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "1804310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "1805230000020009",
"intro": "Failed to extrude AMS-HT F Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1804230000020009",
"intro": "Failed to extrude AMS-HT E Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1801230000020009",
"intro": "Failed to extrude AMS-HT B Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "18FE810000020001",
"intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead."
},
{
"ecode": "1806220000020009",
"intro": "Failed to extrude AMS-HT G Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0707700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0500020000020003",
"intro": "Failed to connect to the internet; please check the network connection."
},
{
"ecode": "0500040000010002",
"intro": "Failed to report print state; please check your network connection."
},
{
"ecode": "0500040000030008",
"intro": "The door seems to be open."
},
{
"ecode": "0700310000020002",
"intro": "The RFID-tag on AMS A Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0701700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0701700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0702310000020002",
"intro": "The RFID-tag on AMS C Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0702700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0703300000020002",
"intro": "The RFID-tag on AMS D Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0703700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0C00020000010005",
"intro": "A new Micro Lidar was detected. Please calibrate it on the Calibration page before use."
},
{
"ecode": "0702950000010001",
"intro": "AMS C The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0702010000020008",
"intro": "AMS C The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0702810000010003",
"intro": "AMS C The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0300950000010003",
"intro": "Laser module overheating"
},
{
"ecode": "0C00040000010011",
"intro": "Failed to measure material thickness: device parameters abnormal; please setup BirdsEye Camera again."
},
{
"ecode": "0C0003000002000C",
"intro": "The build plate localization marker was not detected. Please check if the build plate is aligned correctly."
},
{
"ecode": "0700800000010003",
"intro": "AMS A The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0700810000010002",
"intro": "AMS A The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300960000010001",
"intro": "The front door seems to be open; the task has been paused."
},
{
"ecode": "0300A20000010001",
"intro": "MC module temperature is too high, possibly because of high chamber temperature of the printer. You can try lowering the environmental temperature before use."
},
{
"ecode": "0300C00000010001",
"intro": "Active Chamber Exhaust malfunction: it may be stuck."
},
{
"ecode": "0703900000010003",
"intro": "AMS D The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0C00040000010013",
"intro": "The exposure parameters of the BirdsEye Camera are not effective; please try again."
},
{
"ecode": "0700800000010002",
"intro": "AMS A The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300950000010002",
"intro": "The temperature sensor of laser module may have an open circuit."
},
{
"ecode": "0705950000010001",
"intro": "AMS F The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1806310000020002",
"intro": "The RFID-tag on AMS-HT G Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1800900000010003",
"intro": "AMS-HT A The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802800000010002",
"intro": "AMS-HT C The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0705010000020008",
"intro": "AMS F The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1802310000020002",
"intro": "The RFID-tag on AMS-HT C Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1805010000020008",
"intro": "AMS-HT F The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0707810000010003",
"intro": "AMS H The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0705940000010001",
"intro": "AMS F The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0707950000010001",
"intro": "AMS H The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0705310000020002",
"intro": "The RFID-tag on AMS F Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1803940000010001",
"intro": "AMS-HT D The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1806810000010002",
"intro": "AMS-HT G The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805330000020002",
"intro": "The RFID-tag on AMS-HT F Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0705320000020002",
"intro": "The RFID-tag on AMS F Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0706910000010003",
"intro": "AMS G The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0706940000010001",
"intro": "AMS G The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1803810000010002",
"intro": "AMS-HT D The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807310000020002",
"intro": "The RFID-tag on AMS-HT H Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1801330000020002",
"intro": "The RFID-tag on AMS-HT B Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1804310000020002",
"intro": "The RFID-tag on AMS-HT E Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1801320000020002",
"intro": "The RFID-tag on AMS-HT B Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "030001000001000D",
"intro": "An abnormality occured in heating modules of heatbed previously. To continue using your printer, please refer to the wiki to troubleshoot."
},
{
"ecode": "0300040000020001",
"intro": "The speed of the part cooling fan is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "0300080000010003",
"intro": "The resistance of Motor-Z is abnormal; the motor may have failed."
},
{
"ecode": "0300090000010003",
"intro": "The resistance of Motor-E is abnormal; the motor may have failed."
},
{
"ecode": "03001B0000010002",
"intro": "External disturbance was detected on the heatbed acceleeration sensor. The sensor signal wire may not be affixed."
},
{
"ecode": "030091000001000C",
"intro": "The chamber heater 1 has worked at full load for a long time. The temperature control system may be abnormal."
},
{
"ecode": "0300940000030001",
"intro": "Chamber cooling may be too slow. You can open the front door or top cover to help cooling if the air in the chamber is non-toxic."
},
{
"ecode": "0500010000020001",
"intro": "The media pipeline is malfunctioning. Please restart the printer. If multiple attempts fail, please contact customer service."
},
{
"ecode": "0500020000020005",
"intro": "Failed to connect to the internet; please check the network connection."
},
{
"ecode": "0500040000010003",
"intro": "The content of print file is unreadable; please resend the print job."
},
{
"ecode": "0500040000030009",
"intro": "The bed temperature exceeds filament's vitrification temperature, which may cause nozzle clog. Please keep the front door of the printer open. Door open detection has been temporarily turned off."
},
{
"ecode": "0500050000010006",
"intro": "The factory data of AP board is abnormal; please replace the AP board with a new one."
},
{
"ecode": "0500050000030002",
"intro": "The device is in the engineering state; please pay attention to information security related matters."
},
{
"ecode": "0700300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0700330000020002",
"intro": "The RFID-tag on AMS A Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0700700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0700700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0701310000020002",
"intro": "The RFID-tag on AMS B Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0701330000020002",
"intro": "The RFID-tag on AMS B Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0701700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0701700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0702300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0702300000020002",
"intro": "The RFID-tag on AMS C Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0702320000020002",
"intro": "The RFID-tag on AMS C Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0702330000020002",
"intro": "The RFID-tag on AMS C Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0702700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0703310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0703310000020002",
"intro": "The RFID-tag on AMS D Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0703700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0703700000020005",
"intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck. Please refer to Assistant for details."
},
{
"ecode": "0703700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0C0001000001000B",
"intro": "Failed to calibrate Micro Lidar. Please make sure the calibration chart is clean and not obscured. Then, run machine calibration again."
},
{
"ecode": "12FF200000020004",
"intro": "Please pull the filament on the spool holder out from the extruder."
},
{
"ecode": "0500060000020002",
"intro": "The AI Nozzle camera is not in place; please check the hardware connection."
},
{
"ecode": "0300A30000010001",
"intro": "No plate detected. Please use the correct plate."
},
{
"ecode": "0702810000010002",
"intro": "AMS C The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300960000010003",
"intro": "The front door Hall sensor 2 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0703010000020008",
"intro": "AMS D The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0500060000020013",
"intro": "laser camera has no mipi interrupt; please check the hardware and line connection."
},
{
"ecode": "050003000001000A",
"intro": "System state is abnormal; please restore to factory settings."
},
{
"ecode": "0702800000010003",
"intro": "AMS C The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0703910000010003",
"intro": "AMS D The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0500060000020012",
"intro": "nozzle camera has no mipi interrupt; please check the hardware and line connection."
},
{
"ecode": "0500060000020006",
"intro": "Too many nozzle mipierrs; please check the hardware and line connections."
},
{
"ecode": "0701350000010002",
"intro": "AMS B The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0500060000020004",
"intro": "The AI Live View camera is not in place; please check the hardware connection."
},
{
"ecode": "0702350000010002",
"intro": "AMS C The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0702940000010001",
"intro": "AMS C The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0300C30000010001",
"intro": "Current sensor of Active Chamber Exhaust malfunction; this may be due to open circuit or a hardware sampling circuit fault."
},
{
"ecode": "0700010000020008",
"intro": "AMS A The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0701010000020007",
"intro": "AMS B The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "030001000001000E",
"intro": "The power supply voltage does not match the machine; the heatbed has been disabled."
},
{
"ecode": "0300980000010003",
"intro": "The left side window Hall sensor 2 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0702900000010003",
"intro": "AMS C The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0300330000010001",
"intro": "The Chamber Exhaust Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "03001E0000010006",
"intro": "The left extruder nozzle temperature is abnormal; the sensor may have a short circuit, please check whether the connector is properly plugged in."
},
{
"ecode": "0300950000010006",
"intro": "The laser module not detected. The module may have fallen off, or the quick-release lever may not be locked."
},
{
"ecode": "0300360000010001",
"intro": "The Chamber Heat Circulation Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "0C0003000003000D",
"intro": "Some objects may have fallen down, or the extruder is not extruding normally. Please check and decide if printing should be stopped."
},
{
"ecode": "0300960000010002",
"intro": "The front door Hall sensor 1 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0706330000020002",
"intro": "The RFID-tag on AMS G Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1804910000010003",
"intro": "AMS-HT E The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802910000010003",
"intro": "AMS-HT C The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1805310000020002",
"intro": "The RFID-tag on AMS-HT F Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0706350000010002",
"intro": "AMS G The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807010000020007",
"intro": "AMS-HT H The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0707800000010002",
"intro": "AMS H The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805320000020002",
"intro": "The RFID-tag on AMS-HT F Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0704310000020002",
"intro": "The RFID-tag on AMS E Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0704950000010001",
"intro": "AMS E The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0705810000010003",
"intro": "AMS F The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1801350000010002",
"intro": "AMS-HT B The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806800000010003",
"intro": "AMS-HT G The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1806940000010001",
"intro": "AMS-HT G The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0707800000010003",
"intro": "AMS H The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1807350000010002",
"intro": "AMS-HT H The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707300000020002",
"intro": "The RFID-tag on AMS H Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0707910000010003",
"intro": "AMS H The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802900000010003",
"intro": "AMS-HT C The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1801810000010002",
"intro": "AMS-HT B The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801310000020002",
"intro": "The RFID-tag on AMS-HT B Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0707310000020002",
"intro": "The RFID-tag on AMS H Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1803010000020007",
"intro": "AMS-HT D The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0704800000010002",
"intro": "AMS E The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800330000020002",
"intro": "The RFID-tag on AMS-HT A Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0706810000010003",
"intro": "AMS G The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1804810000010003",
"intro": "AMS-HT E The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1802350000010002",
"intro": "AMS-HT C The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800810000010002",
"intro": "AMS-HT A The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706810000010002",
"intro": "AMS G The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806950000010001",
"intro": "AMS-HT G The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1800950000010001",
"intro": "AMS-HT A The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1807900000010003",
"intro": "AMS-HT H The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1804950000010001",
"intro": "AMS-HT E The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0706320000020002",
"intro": "The RFID-tag on AMS G Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1806010000020008",
"intro": "AMS-HT G The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1807810000010003",
"intro": "AMS-HT H The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0705800000010002",
"intro": "AMS F The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706800000010003",
"intro": "AMS G The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0707010000020008",
"intro": "AMS H The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0705300000020002",
"intro": "The RFID-tag on AMS F Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1800910000010003",
"intro": "AMS-HT A The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0704810000010002",
"intro": "AMS E The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806300000020002",
"intro": "The RFID-tag on AMS-HT G Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1806910000010003",
"intro": "AMS-HT G The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1803900000010003",
"intro": "AMS-HT D The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1804320000020002",
"intro": "The RFID-tag on AMS-HT E Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1803800000010002",
"intro": "AMS-HT D The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1805010000020007",
"intro": "AMS-HT F The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1805910000010003",
"intro": "AMS-HT F The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0706310000020002",
"intro": "The RFID-tag on AMS G Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1804800000010003",
"intro": "AMS-HT E The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0705330000020002",
"intro": "The RFID-tag on AMS F Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1803800000010003",
"intro": "AMS-HT D The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0300010000010008",
"intro": "An abnormality occurs during the heating process of the heatbed; the heating modules may be broken."
},
{
"ecode": "0300060000010003",
"intro": "The resistance of Motor-A is abnormal; the motor may have failed."
},
{
"ecode": "0300900000010002",
"intro": "Chamber heating failed. The chamber may not be enclosed, the ambient temperature may be too low, or the heat dissipation vent of the power supply may be blocked."
},
{
"ecode": "0500010000020003",
"intro": "Live View camera format is incorrect. Please restart the printer. If multiple attempts fail, please contact customer service."
},
{
"ecode": "0500030000010021",
"intro": "Hardware incompatible; please check the laser."
},
{
"ecode": "0700300000020002",
"intro": "The RFID-tag on AMS A Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0700320000020002",
"intro": "The RFID-tag on AMS A Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0700400000020004",
"intro": "The filament buffer signal is abnormal; the spring may be stuck, or the filament may be tangled."
},
{
"ecode": "0700700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0701300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0701320000020002",
"intro": "The RFID-tag on AMS B Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0702310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0702700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0703300000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0703330000020002",
"intro": "The RFID-tag on AMS D Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0C00010000020007",
"intro": "Micro Lidar laser parameters have drifted. Please re-calibrate your printer."
},
{
"ecode": "0C00020000010001",
"intro": "The horizontal laser is not lit. Please check if it's covered or hardware connection has a problem."
},
{
"ecode": "0C00020000020004",
"intro": "Nozzle height seems to be too low. Please check if the nozzle is worn or tilted. Re-calibrate Lidar if the nozzle has been replaced."
},
{
"ecode": "0C0003000002000F",
"intro": "Parts skipped before first layer inspection; the inspection is not supported for the current print."
},
{
"ecode": "0C00030000020010",
"intro": "Foreign objects detected on heatbed; Please check and clean the heatbed."
},
{
"ecode": "12FF200000020006",
"intro": "Failed to extrude the filament; the extruder may be clogged."
},
{
"ecode": "0500060000020007",
"intro": "Too many laser mipierrs; please check the hardware and line connections."
},
{
"ecode": "0C00040000010014",
"intro": "Cutting Protection Base not detected, which\nmay lead to heatbed damage. Please place it and continue."
},
{
"ecode": "030091000001000E",
"intro": "The power supply voltage does not match the machine; chamber heater 1 has been disabled."
},
{
"ecode": "0703800000010002",
"intro": "AMS D The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0703950000010001",
"intro": "AMS D The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0700550000020001",
"intro": "New AMS connected; please set up before use."
},
{
"ecode": "0703350000010002",
"intro": "AMS D The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "07FE800000010003",
"intro": "The toolhead lift motor position hall signal is abnormal during extruder switching."
},
{
"ecode": "0701910000010003",
"intro": "AMS B The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0700940000010001",
"intro": "AMS A The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0700350000010002",
"intro": "AMS A The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0500060000020005",
"intro": "Too many xcam mipierrs; please check the hardware and line connections."
},
{
"ecode": "0703810000010002",
"intro": "AMS D The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0700010000020007",
"intro": "AMS A The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0701800000010002",
"intro": "AMS B The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0300C00000010003",
"intro": "Automatic Top Vent malfunction: it may be stuck."
},
{
"ecode": "0300C30000010003",
"intro": "Current sensor of Automatic Top Vent malfunction: this may be due to open circuit or a hardware sampling circuit fault."
},
{
"ecode": "0500060000020011",
"intro": "xcam has no mipi interrupt; please check the hardware and line connection."
},
{
"ecode": "0703940000010001",
"intro": "AMS D The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0701800000010003",
"intro": "AMS B The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0700910000010003",
"intro": "AMS A The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0703010000020007",
"intro": "AMS D The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0300090000020002",
"intro": "The extrusion resistance is abnormal. The extruder may be clogged or there may be filament stuck in the toolhead."
},
{
"ecode": "0300980000010001",
"intro": "The left side window seems to be open, the task has been paused."
},
{
"ecode": "0700900000010003",
"intro": "AMS A The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0300950000010004",
"intro": "The speed of the laser module cooling fan is too low or stopped. It may be stuck or the connector may not be plugged in properly."
},
{
"ecode": "0500060000020014",
"intro": "Liveview camera has no mipi interrupt; please check the hardware and line connection."
},
{
"ecode": "0701950000010001",
"intro": "AMS B The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0300970000010002",
"intro": "The top cover Hall sensor 1 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0300980000010002",
"intro": "The left side window Hall sensor 1 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0703810000010003",
"intro": "AMS D The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0300970000010001",
"intro": "The top cover seems to be open; the task has been paused"
},
{
"ecode": "0300310000010001",
"intro": "The Part Cooling Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "0500060000020003",
"intro": "The BirdsEye camera is not in place; please check the hardware connection"
},
{
"ecode": "0300320000010001",
"intro": "The Auxiliary Part Cooling Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "0702010000020007",
"intro": "AMS C The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0300020000010006",
"intro": "The right extruder nozzle temperature is abnormal; the sensor may have a short circuit, please check whether the connector is properly plugged in."
},
{
"ecode": "1805810000010003",
"intro": "AMS-HT F The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1805940000010001",
"intro": "AMS-HT F The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1801940000010001",
"intro": "AMS-HT B The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1804330000020002",
"intro": "The RFID-tag on AMS-HT E Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1807940000010001",
"intro": "AMS-HT H The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1804800000010002",
"intro": "AMS-HT E The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706800000010002",
"intro": "AMS G The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706010000020008",
"intro": "AMS G The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1807910000010003",
"intro": "AMS-HT H The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0704350000010002",
"intro": "AMS E The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800010000020007",
"intro": "AMS-HT A The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1801950000010001",
"intro": "AMS-HT B The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0704800000010003",
"intro": "AMS E The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0705910000010003",
"intro": "AMS F The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802940000010001",
"intro": "AMS-HT C The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1804300000020002",
"intro": "The RFID-tag on AMS-HT E Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1804010000020007",
"intro": "AMS-HT E The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0707010000020007",
"intro": "AMS H The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1803350000010002",
"intro": "AMS-HT D The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1800810000010003",
"intro": "AMS-HT A The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1804810000010002",
"intro": "AMS-HT E The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803310000020002",
"intro": "The RFID-tag on AMS-HT D Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "0705350000010002",
"intro": "AMS F The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802300000020002",
"intro": "The RFID-tag on AMS-HT C Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1807320000020002",
"intro": "The RFID-tag on AMS-HT H Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1805810000010002",
"intro": "AMS-HT F The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803010000020008",
"intro": "AMS-HT D The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1802810000010002",
"intro": "AMS-HT C The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803810000010003",
"intro": "AMS-HT D The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0706010000020007",
"intro": "AMS G The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1801910000010003",
"intro": "AMS-HT B The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1804350000010002",
"intro": "AMS-HT E The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0707900000010003",
"intro": "AMS H The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0704900000010003",
"intro": "AMS E The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802010000020007",
"intro": "AMS-HT C The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1807950000010001",
"intro": "AMS-HT H The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0705010000020007",
"intro": "AMS F The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1801800000010002",
"intro": "AMS-HT B The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0704300000020002",
"intro": "The RFID-tag on AMS E Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1801900000010003",
"intro": "AMS-HT B The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1805350000010002",
"intro": "AMS-HT F The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706900000010003",
"intro": "AMS G The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1803300000020002",
"intro": "The RFID-tag on AMS-HT D Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1802950000010001",
"intro": "AMS-HT C The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1801800000010003",
"intro": "AMS-HT B The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1807010000020008",
"intro": "AMS-HT H The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1805950000010001",
"intro": "AMS-HT F The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1801010000020008",
"intro": "AMS-HT B The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1806320000020002",
"intro": "The RFID-tag on AMS-HT G Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1803950000010001",
"intro": "AMS-HT D The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1804940000010001",
"intro": "AMS-HT E The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0705800000010003",
"intro": "AMS F The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1804900000010003",
"intro": "AMS-HT E The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1802810000010003",
"intro": "AMS-HT C The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1804010000020008",
"intro": "AMS-HT E The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1800300000020002",
"intro": "The RFID-tag on AMS-HT A Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "030001000001000A",
"intro": "The heatbed temperature control is abnormal; the AC board may be broken."
},
{
"ecode": "0300030000010001",
"intro": "The hotend cooling fan speed is too slow or stopped. It may be stuck or the connector may not be plugged in properly."
},
{
"ecode": "0300070000010003",
"intro": "The resistance of Motor-B is abnormal; the motor may have failed."
},
{
"ecode": "03001D0000010001",
"intro": "The position sensor of extrusion motor is abnormal. The connection to the sensor may be loose."
},
{
"ecode": "0300410000010001",
"intro": "The system voltage is unstable, triggering the power failure protection function."
},
{
"ecode": "0500020000020001",
"intro": "Failed to connect to the internet. Please check the network connection."
},
{
"ecode": "0500040000010001",
"intro": "Failed to download print job; please check your network connection."
},
{
"ecode": "0500040000010006",
"intro": "Failed to resume previous print"
},
{
"ecode": "0700310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0700400000020003",
"intro": "The AMS Hub communication is abnormal; the cable may be not well connected."
},
{
"ecode": "0700700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0700700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0701300000020002",
"intro": "The RFID-tag on AMS B Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0701310000010004",
"intro": "Encryption chip failure"
},
{
"ecode": "0701700000020002",
"intro": "Failed to feed the filament into the toolhead. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0702700000020003",
"intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0702700000020006",
"intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog. Please refer to Assistant for details."
},
{
"ecode": "0703320000020002",
"intro": "The RFID-tag on AMS D Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "0703700000020004",
"intro": "Failed to pull back the filament from the toolhead to AMS. Possible cause: filament or spool stuck. Please refer to Assistant for details."
},
{
"ecode": "0C00020000020003",
"intro": "The horizontal laser is not bright enough at homing position. Please clean or replace the heatbed if this message appears repeatedly."
},
{
"ecode": "0C00020000020006",
"intro": "Nozzle height seems to be too high. Please check if there is filament residual attached to the nozzle."
},
{
"ecode": "0C00020000020007",
"intro": "The vertical laser is not lit. Please check if it's covered or hardware connection has a problem."
},
{
"ecode": "0C00020000020009",
"intro": "The vertical laser is not bright enough at homing position. Please clean or replace the heatbed if this message appears repeatedly."
},
{
"ecode": "0300950000010001",
"intro": "The temperature sensor of laser module may have a short circuit."
},
{
"ecode": "0702910000010003",
"intro": "AMS C The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0300980000030001",
"intro": "The left side window seems to be open."
},
{
"ecode": "0500060000020001",
"intro": "The Toolhead camera is not in place; please check the hardware connection"
},
{
"ecode": "0701810000010003",
"intro": "AMS B The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0701010000020008",
"intro": "AMS B The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0500040000020033",
"intro": "Please plug in the module connector."
},
{
"ecode": "0300090000020003",
"intro": "The extruder is extruding abnormally. It may be clogged, or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700950000010001",
"intro": "AMS A The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0703800000010003",
"intro": "AMS D The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0300950000010005",
"intro": "The laser module communication is abnormal; please check the connector."
},
{
"ecode": "0300350000010001",
"intro": "The MC module cooling fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly."
},
{
"ecode": "0C00040000010005",
"intro": "BirdsEye Camera malfunction: please contact customer service."
},
{
"ecode": "0701940000010001",
"intro": "AMS B The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0300A30000010003",
"intro": "The plate type is invalid. Please use the correct plate."
},
{
"ecode": "0300970000030001",
"intro": "The top cover seems to be open."
},
{
"ecode": "0701810000010002",
"intro": "AMS B The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "07FF800000010003",
"intro": "The toolhead lift motor position hall signal is abnormal during extruder switching."
},
{
"ecode": "0C00040000010010",
"intro": "Failed to measure material thickness due to laser module malfunction."
},
{
"ecode": "03001E0000010009",
"intro": "The left extruder nozzle temperature control is abnormal; the hot end may not be installed. If you want to heat the hot end without it being installed, please turn on maintenance mode in the settings page."
},
{
"ecode": "0700810000010003",
"intro": "AMS A The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0702800000010002",
"intro": "AMS C The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0701900000010003",
"intro": "AMS B The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0300970000010003",
"intro": "The top cover Hall sensor 2 is abnormal; please check whether the connection wire is loose."
},
{
"ecode": "0300020000010009",
"intro": "The right extruder nozzle temperature control is abnormal; the hot end may not be installed. If you want to heat the hot end without it being installed, please turn on maintenance mode in the settings page."
},
{
"ecode": "1803330000020002",
"intro": "The RFID-tag on AMS-HT D Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1807800000010002",
"intro": "AMS-HT H The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806330000020002",
"intro": "The RFID-tag on AMS-HT G Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1802010000020008",
"intro": "AMS-HT C The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0705900000010003",
"intro": "AMS F The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0704010000020008",
"intro": "AMS E The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "1800350000010002",
"intro": "AMS-HT A The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1803910000010003",
"intro": "AMS-HT D The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "0704810000010003",
"intro": "AMS E The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1805800000010002",
"intro": "AMS-HT F The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706300000020002",
"intro": "The RFID-tag on AMS G Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1806810000010003",
"intro": "AMS-HT G The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0707350000010002",
"intro": "AMS H The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801300000020002",
"intro": "The RFID-tag on AMS-HT B Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0704010000020007",
"intro": "AMS E The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "1800010000020008",
"intro": "AMS-HT A The assist motor phase winding has an open circuit. The assist motor may be faulty."
},
{
"ecode": "0707320000020002",
"intro": "The RFID-tag on AMS H Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1806010000020007",
"intro": "AMS-HT G The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0707330000020002",
"intro": "The RFID-tag on AMS H Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "0704940000010001",
"intro": "AMS E The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "1806900000010003",
"intro": "AMS-HT G The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1800800000010003",
"intro": "AMS-HT A The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1805300000020002",
"intro": "The RFID-tag on AMS-HT F Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "0705810000010002",
"intro": "AMS F The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807300000020002",
"intro": "The RFID-tag on AMS-HT H Slot1 is damaged, or its content cannot be identified."
},
{
"ecode": "1807810000010002",
"intro": "AMS-HT H The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1802800000010003",
"intro": "AMS-HT C The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1805900000010003",
"intro": "AMS-HT F The exhaust valve 1 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1807800000010003",
"intro": "AMS-HT H The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0707810000010002",
"intro": "AMS H The heater 2 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1806350000010002",
"intro": "AMS-HT G The humidity sensor is disconnected, which may be due to poor connector contact."
},
{
"ecode": "0706950000010001",
"intro": "AMS G The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0704320000020002",
"intro": "The RFID-tag on AMS E Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1800320000020002",
"intro": "The RFID-tag on AMS-HT A Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1803320000020002",
"intro": "The RFID-tag on AMS-HT D Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1802320000020002",
"intro": "The RFID-tag on AMS-HT C Slot3 is damaged, or its content cannot be identified."
},
{
"ecode": "1800940000010001",
"intro": "AMS-HT A The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0704330000020002",
"intro": "The RFID-tag on AMS E Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1802330000020002",
"intro": "The RFID-tag on AMS-HT C Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1800800000010002",
"intro": "AMS-HT A The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1807330000020002",
"intro": "The RFID-tag on AMS-HT H Slot4 is damaged, or its content cannot be identified."
},
{
"ecode": "1800310000020002",
"intro": "The RFID-tag on AMS-HT A Slot2 is damaged, or its content cannot be identified."
},
{
"ecode": "1805800000010003",
"intro": "AMS-HT F The heater 1 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "0704910000010003",
"intro": "AMS E The exhaust valve 2 is not connected, which may be due to poor connector contact."
},
{
"ecode": "1806800000010002",
"intro": "AMS-HT G The heater 1 is disconnected, which may be due to poor connector contact."
},
{
"ecode": "1801810000010003",
"intro": "AMS-HT B The heater 2 is short-circuited, which may be due to a wiring short or heater damage."
},
{
"ecode": "1801010000020007",
"intro": "AMS-HT B The assist motor encoder wires are not connected. The assist motor connector may have poor contact."
},
{
"ecode": "0707940000010001",
"intro": "AMS H The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact."
},
{
"ecode": "0500030000020010",
"intro": "forward coredump, it is recovering."
},
{
"ecode": "0500030000020011",
"intro": "upgrade coredump, it is recovering."
},
{
"ecode": "0500030000020012",
"intro": "ipcam coredump, it is recovering."
},
{
"ecode": "0500030000020013",
"intro": "xcam coredump, it is recovering."
},
{
"ecode": "0500030000020014",
"intro": "bbl_screen coredump, it is recovering."
},
{
"ecode": "0500030000020015",
"intro": "device_gate coredump, it is recovering."
},
{
"ecode": "0500030000020016",
"intro": "device_manager coredump, it is recovering."
},
{
"ecode": "0500030000020017",
"intro": "recorder coredump, it is recovering."
},
{
"ecode": "0500030000020018",
"intro": "security coredump, it is recovering."
},
{
"ecode": "0500010000020009",
"intro": "The fps of the MIPI camera is less than 1."
},
{
"ecode": "0500010000030009",
"intro": "The fps of the MIPI camera is less than 1."
},
{
"ecode": "05000600000200A1",
"intro": "AP reboot boot_reason=watchdog"
},
{
"ecode": "0500060000020023",
"intro": "laser camera detects low cif/isp/ispp frame rates."
},
{
"ecode": "05000600000200A0",
"intro": "AP reboot boot_reason=panic"
},
{
"ecode": "0500060000020022",
"intro": "nozzle camera detects low cif/isp/ispp frame rates."
},
{
"ecode": "0500060000020021",
"intro": "xcam camera detects low cif/isp/ispp frame rates."
},
{
"ecode": "0300C10000010001",
"intro": "Adaptive Airflow System can't activate cooling mode; please check the air door status."
},
{
"ecode": "0300C10000010003",
"intro": "Adaptive Airflow System can't activate laser/cutting mode; please check the air door status."
},
{
"ecode": "0703220000020009",
"intro": "Failed to extrude AMS D Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700230000020009",
"intro": "Failed to extrude AMS A Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0702220000020009",
"intro": "Failed to extrude AMS C Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0703210000020009",
"intro": "Failed to extrude AMS D Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0701230000020009",
"intro": "Failed to extrude AMS B Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0701210000020009",
"intro": "Failed to extrude AMS B Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0701200000020009",
"intro": "Failed to extrude AMS B Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700210000020009",
"intro": "Failed to extrude AMS A Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0703200000020009",
"intro": "Failed to extrude AMS D Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0C0001000003000C",
"intro": "The nozzle camera's temperature is too high, causing the AI detection feature to pause. The feature will automatically resume once the temperature returns to normal."
},
{
"ecode": "0700200000020009",
"intro": "Failed to extrude AMS A Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0702210000020009",
"intro": "Failed to extrude AMS C Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0702230000020009",
"intro": "Failed to extrude AMS C Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0701220000020009",
"intro": "Failed to extrude AMS B Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0703230000020009",
"intro": "Failed to extrude AMS D Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0300C10000010002",
"intro": "Adaptive Airflow System can't activate heating mode; please check the air door status."
},
{
"ecode": "0702200000020009",
"intro": "Failed to extrude AMS C Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700220000020009",
"intro": "Failed to extrude AMS A Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0700310000010001",
"intro": "The AMS A RFID 2 board has an error."
},
{
"ecode": "0702310000010001",
"intro": "The AMS C RFID 2 board has an error."
},
{
"ecode": "0707930000010001",
"intro": "AMS H The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0704010000020002",
"intro": "The AMS E assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1800010000010001",
"intro": "The AMS-HT A assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0702550000010003",
"intro": "AMS C was detected offline during the AMS initialization process."
},
{
"ecode": "0706010000010001",
"intro": "The AMS G assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1803930000020002",
"intro": "AMS-HT D The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1803130000020004",
"intro": "AMS-HT D The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1803110000020004",
"intro": "AMS-HT D The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0707010000020006",
"intro": "AMS H The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1800010000010003",
"intro": "The AMS-HT A assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706120000020004",
"intro": "AMS G The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1806010000010005",
"intro": "AMS-HT G The currentsensor of assist motor may be faulty."
},
{
"ecode": "1803910000010002",
"intro": "AMS-HT D The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1807130000020004",
"intro": "AMS-HT H The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1807960000010001",
"intro": "AMS-HT H The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1806910000010002",
"intro": "AMS-HT G The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1804920000020002",
"intro": "AMS-HT E The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1805910000020001",
"intro": "AMS-HT F The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1802920000020002",
"intro": "AMS-HT C The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1800310000010001",
"intro": "The AMS-HT A RFID 2 board has an error."
},
{
"ecode": "1800020000020002",
"intro": "AMS-HT A The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1803010000020010",
"intro": "AMS-HT D The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0700550000010003",
"intro": "AMS A was detected offline during the AMS initialization process."
},
{
"ecode": "0706800000010004",
"intro": "AMS G The heater 1 heating abnormally."
},
{
"ecode": "1800930000010001",
"intro": "AMS-HT A The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1801910000020001",
"intro": "AMS-HT B The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0707010000010005",
"intro": "AMS H The currentsensor of assist motor may be faulty."
},
{
"ecode": "1803020000020002",
"intro": "AMS-HT D The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1801300000010001",
"intro": "The AMS-HT B RFID 1 board has an error."
},
{
"ecode": "0701310000010001",
"intro": "The AMS B RFID 2 board has an error."
},
{
"ecode": "0704010000010004",
"intro": "The AMS E assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1803100000020004",
"intro": "AMS-HT D The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1806010000010004",
"intro": "The AMS-HT G assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1801130000020004",
"intro": "AMS-HT B The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0706110000020004",
"intro": "AMS G The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0705920000020002",
"intro": "AMS F The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0707810000010001",
"intro": "AMS H The current sensor of heater 2 is abnormal."
},
{
"ecode": "1801020000020002",
"intro": "AMS-HT B The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "0704910000010002",
"intro": "AMS E The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1802010000010001",
"intro": "The AMS-HT C assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0706010000020011",
"intro": "AMS G The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0706010000010003",
"intro": "The AMS G assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705010000020011",
"intro": "AMS F The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1800110000020004",
"intro": "AMS-HT A The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0707010000010003",
"intro": "The AMS H assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1805110000020004",
"intro": "AMS-HT F The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1805810000010001",
"intro": "AMS-HT F The current sensor of heater 2 is abnormal."
},
{
"ecode": "1803120000020004",
"intro": "AMS-HT D The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1801900000020001",
"intro": "AMS-HT B The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1805010000010001",
"intro": "The AMS-HT F assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1801900000010002",
"intro": "AMS-HT B The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1804010000020011",
"intro": "AMS-HT E The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1802010000020011",
"intro": "AMS-HT C The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1806120000020004",
"intro": "AMS-HT G The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1803020000010001",
"intro": "AMS-HT D Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0705810000010004",
"intro": "AMS F The heater 2 heating abnormally."
},
{
"ecode": "0706010000020009",
"intro": "AMS G The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1806010000010003",
"intro": "The AMS-HT G assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1807500000020001",
"intro": "AMS-HT H communication is abnormal; please check the connection cable."
},
{
"ecode": "1803960000010001",
"intro": "AMS-HT D The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1806300000010001",
"intro": "The AMS-HT G RFID 1 board has an error."
},
{
"ecode": "1800810000010001",
"intro": "AMS-HT A The current sensor of heater 2 is abnormal."
},
{
"ecode": "0706010000010005",
"intro": "AMS G The currentsensor of assist motor may be faulty."
},
{
"ecode": "1801100000020004",
"intro": "AMS-HT B The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704010000010005",
"intro": "AMS E The currentsensor of assist motor may be faulty."
},
{
"ecode": "0706130000020004",
"intro": "AMS G The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0707020000020002",
"intro": "AMS H The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1803900000010002",
"intro": "AMS-HT D The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0704010000020011",
"intro": "AMS E The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0707010000020011",
"intro": "AMS H The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1802010000010003",
"intro": "The AMS-HT C assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1801930000010001",
"intro": "AMS-HT B The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807930000010001",
"intro": "AMS-HT H The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1800930000020002",
"intro": "AMS-HT A The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0706930000020002",
"intro": "AMS G The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0707010000020002",
"intro": "The AMS H assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1800910000020001",
"intro": "AMS-HT A The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1807110000020004",
"intro": "AMS-HT H The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1801810000010001",
"intro": "AMS-HT B The current sensor of heater 2 is abnormal."
},
{
"ecode": "0704020000010001",
"intro": "AMS E Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1801010000010005",
"intro": "AMS-HT B The currentsensor of assist motor may be faulty."
},
{
"ecode": "1802310000010001",
"intro": "The AMS-HT C RFID 2 board has an error."
},
{
"ecode": "0706100000020004",
"intro": "AMS G The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1800130000020004",
"intro": "AMS-HT A The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1804010000020002",
"intro": "The AMS-HT E assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0706010000020006",
"intro": "AMS G The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0704810000010001",
"intro": "AMS E The current sensor of heater 2 is abnormal."
},
{
"ecode": "0705110000020004",
"intro": "AMS F The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1801020000010001",
"intro": "AMS-HT B Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1802020000020002",
"intro": "AMS-HT C The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1805020000010001",
"intro": "AMS-HT F Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1806800000010001",
"intro": "AMS-HT G The current sensor of heater 1 is abnormal."
},
{
"ecode": "0704930000010001",
"intro": "AMS E The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1802910000010002",
"intro": "AMS-HT C The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1801010000020010",
"intro": "AMS-HT B The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1806900000020001",
"intro": "AMS-HT G The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1806810000010004",
"intro": "AMS-HT G The heater 2 heating abnormally."
},
{
"ecode": "0704010000010011",
"intro": "AMS E The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1804110000020004",
"intro": "AMS-HT E The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1804900000010002",
"intro": "AMS-HT E The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1800100000020004",
"intro": "AMS-HT A The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1806800000010004",
"intro": "AMS-HT G The heater 1 heating abnormally."
},
{
"ecode": "1802130000020004",
"intro": "AMS-HT C The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1806500000020001",
"intro": "AMS-HT G communication is abnormal; please check the connection cable."
},
{
"ecode": "0707800000010001",
"intro": "AMS H The current sensor of heater 1 is abnormal."
},
{
"ecode": "0705900000010002",
"intro": "AMS F The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1801010000020011",
"intro": "AMS-HT B The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705800000010001",
"intro": "AMS F The current sensor of heater 1 is abnormal."
},
{
"ecode": "1805010000010003",
"intro": "The AMS-HT F assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1804120000020004",
"intro": "AMS-HT E The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703550000010003",
"intro": "AMS D was detected offline during the AMS initialization process."
},
{
"ecode": "1807010000020010",
"intro": "AMS-HT H The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1802900000020001",
"intro": "AMS-HT C The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1807900000020001",
"intro": "AMS-HT H The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0706900000010002",
"intro": "AMS G The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0704310000010001",
"intro": "The AMS E RFID 2 board has an error."
},
{
"ecode": "0707120000020004",
"intro": "AMS H The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1803500000020001",
"intro": "AMS-HT D communication is abnormal; please check the connection cable."
},
{
"ecode": "1804500000020001",
"intro": "AMS-HT E communication is abnormal; please check the connection cable."
},
{
"ecode": "1800020000010001",
"intro": "AMS-HT A Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0702010000010011",
"intro": "AMS C The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1804960000010001",
"intro": "AMS-HT E The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1805920000020002",
"intro": "AMS-HT F The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0706920000010001",
"intro": "AMS G The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1803930000010001",
"intro": "AMS-HT D The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1800120000020004",
"intro": "AMS-HT A The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1803920000010001",
"intro": "AMS-HT D The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0707800000010004",
"intro": "AMS H The heater 1 heating abnormally."
},
{
"ecode": "0704300000010001",
"intro": "The AMS E RFID 1 board has an error."
},
{
"ecode": "0706930000010001",
"intro": "AMS G The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1802800000010001",
"intro": "AMS-HT C The current sensor of heater 1 is abnormal."
},
{
"ecode": "1804100000020004",
"intro": "AMS-HT E The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0705930000020002",
"intro": "AMS F The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0707110000020004",
"intro": "AMS H The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1800900000020001",
"intro": "AMS-HT A The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1806010000020011",
"intro": "AMS-HT G The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1807910000020001",
"intro": "AMS-HT H The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0704020000020002",
"intro": "AMS E The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1804010000020009",
"intro": "AMS-HT E The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1807010000020011",
"intro": "AMS-HT H The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1802010000020009",
"intro": "AMS-HT C The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1807920000020002",
"intro": "AMS-HT H The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0705010000020002",
"intro": "The AMS F assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1806010000020002",
"intro": "The AMS-HT G assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804010000010003",
"intro": "The AMS-HT E assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706960000010001",
"intro": "AMS G The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1801920000020002",
"intro": "AMS-HT B The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0705100000020004",
"intro": "AMS F The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1803800000010001",
"intro": "AMS-HT D The current sensor of heater 1 is abnormal."
},
{
"ecode": "1803010000020002",
"intro": "The AMS-HT D assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1804920000010001",
"intro": "AMS-HT E The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807810000010004",
"intro": "AMS-HT H The heater 2 heating abnormally."
},
{
"ecode": "1801010000010004",
"intro": "The AMS-HT B assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1803910000020001",
"intro": "AMS-HT D The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1802910000020001",
"intro": "AMS-HT C The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1806020000010001",
"intro": "AMS-HT G Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0705010000010005",
"intro": "AMS F The currentsensor of assist motor may be faulty."
},
{
"ecode": "1803010000010001",
"intro": "The AMS-HT D assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0707310000010001",
"intro": "The AMS H RFID 2 board has an error."
},
{
"ecode": "1801800000010004",
"intro": "AMS-HT B The heater 1 heating abnormally."
},
{
"ecode": "0707020000010001",
"intro": "AMS H Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0706810000010004",
"intro": "AMS G The heater 2 heating abnormally."
},
{
"ecode": "1807010000010001",
"intro": "The AMS-HT H assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0705010000010001",
"intro": "The AMS F assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0700300000010001",
"intro": "The AMS A RFID 1 board has an error."
},
{
"ecode": "0701300000010001",
"intro": "The AMS B RFID 1 board has an error."
},
{
"ecode": "0702300000010001",
"intro": "The AMS C RFID 1 board has an error."
},
{
"ecode": "0C00010000010009",
"intro": "The liveview camera lens seems to be dirty. Please clean the lens."
},
{
"ecode": "0706910000020001",
"intro": "AMS G The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1805010000010005",
"intro": "AMS-HT F The currentsensor of assist motor may be faulty."
},
{
"ecode": "0707960000010001",
"intro": "AMS H The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1806020000020002",
"intro": "AMS-HT G The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1802020000010001",
"intro": "AMS-HT C Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0704010000020010",
"intro": "AMS E The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1803010000010004",
"intro": "The AMS-HT D assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1803810000010001",
"intro": "AMS-HT D The current sensor of heater 2 is abnormal."
},
{
"ecode": "0707900000010002",
"intro": "AMS H The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1805010000020009",
"intro": "AMS-HT F The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1800010000020002",
"intro": "The AMS-HT A assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0704010000020009",
"intro": "AMS E The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1807020000020002",
"intro": "AMS-HT H The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "0706910000010002",
"intro": "AMS G The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1805800000010001",
"intro": "AMS-HT F The current sensor of heater 1 is abnormal."
},
{
"ecode": "1805810000010004",
"intro": "AMS-HT F The heater 2 heating abnormally."
},
{
"ecode": "1802010000010005",
"intro": "AMS-HT C The currentsensor of assist motor may be faulty."
},
{
"ecode": "0705920000010001",
"intro": "AMS F The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1801800000010001",
"intro": "AMS-HT B The current sensor of heater 1 is abnormal."
},
{
"ecode": "0706020000010001",
"intro": "AMS G Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1806960000010001",
"intro": "AMS-HT G The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1804010000020006",
"intro": "AMS-HT E The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1803310000010001",
"intro": "The AMS-HT D RFID 2 board has an error."
},
{
"ecode": "0704930000020002",
"intro": "AMS E The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1804810000010004",
"intro": "AMS-HT E The heater 2 heating abnormally."
},
{
"ecode": "1807010000010005",
"intro": "AMS-HT H The currentsensor of assist motor may be faulty."
},
{
"ecode": "1802930000010001",
"intro": "AMS-HT C The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807910000010002",
"intro": "AMS-HT H The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1801010000020002",
"intro": "The AMS-HT B assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0705900000020001",
"intro": "AMS F The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1803010000020006",
"intro": "AMS-HT D The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0707930000020002",
"intro": "AMS H The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1801310000010001",
"intro": "The AMS-HT B RFID 2 board has an error."
},
{
"ecode": "1806310000010001",
"intro": "The AMS-HT G RFID 2 board has an error."
},
{
"ecode": "1805310000010001",
"intro": "The AMS-HT F RFID 2 board has an error."
},
{
"ecode": "1804800000010001",
"intro": "AMS-HT E The current sensor of heater 1 is abnormal."
},
{
"ecode": "1807010000010003",
"intro": "The AMS-HT H assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0707910000010002",
"intro": "AMS H The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0705020000020002",
"intro": "AMS F The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1805960000010001",
"intro": "AMS-HT F The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1807010000020002",
"intro": "The AMS-HT H assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0701010000010011",
"intro": "AMS B The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1807010000010011",
"intro": "AMS-HT H The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0704550000010003",
"intro": "AMS E was detected offline during the AMS initialization process."
},
{
"ecode": "1805900000020001",
"intro": "AMS-HT F The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1802300000010001",
"intro": "The AMS-HT C RFID 1 board has an error."
},
{
"ecode": "1805120000020004",
"intro": "AMS-HT F The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1805300000010001",
"intro": "The AMS-HT F RFID 1 board has an error."
},
{
"ecode": "1803010000020011",
"intro": "AMS-HT D The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705310000010001",
"intro": "The AMS F RFID 2 board has an error."
},
{
"ecode": "1800010000020009",
"intro": "AMS-HT A The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1805010000020002",
"intro": "The AMS-HT F assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1802800000010004",
"intro": "AMS-HT C The heater 1 heating abnormally."
},
{
"ecode": "0705960000010001",
"intro": "AMS F The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1807300000010001",
"intro": "The AMS-HT H RFID 1 board has an error."
},
{
"ecode": "1806010000010001",
"intro": "The AMS-HT G assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1800920000010001",
"intro": "AMS-HT A The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1801110000020004",
"intro": "AMS-HT B The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0705010000020009",
"intro": "AMS F The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1801120000020004",
"intro": "AMS-HT B The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1800910000010002",
"intro": "AMS-HT A The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0707810000010004",
"intro": "AMS H The heater 2 heating abnormally."
},
{
"ecode": "1803010000010011",
"intro": "AMS-HT D The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0704910000020001",
"intro": "AMS E The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1801500000020001",
"intro": "AMS-HT B communication is abnormal; please check the connection cable."
},
{
"ecode": "1807120000020004",
"intro": "AMS-HT H The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1800960000010001",
"intro": "AMS-HT A The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1804800000010004",
"intro": "AMS-HT E The heater 1 heating abnormally."
},
{
"ecode": "1800010000020006",
"intro": "AMS-HT A The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1800010000020010",
"intro": "AMS-HT A The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1805010000010011",
"intro": "AMS-HT F The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0704960000010001",
"intro": "AMS E The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "1802900000010002",
"intro": "AMS-HT C The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0707010000020009",
"intro": "AMS H The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0705910000010002",
"intro": "AMS F The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1801010000020009",
"intro": "AMS-HT B The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0705010000010004",
"intro": "The AMS F assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1807010000020006",
"intro": "AMS-HT H The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1805920000010001",
"intro": "AMS-HT F The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1805010000020006",
"intro": "AMS-HT F The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0500040000020030",
"intro": "The BirdsEye Camera is not installed. Please power off printer and then install the camera."
},
{
"ecode": "1805130000020004",
"intro": "AMS-HT F The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0706310000010001",
"intro": "The AMS G RFID 2 board has an error."
},
{
"ecode": "1803010000020009",
"intro": "AMS-HT D The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0706900000020001",
"intro": "AMS G The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1806930000010001",
"intro": "AMS-HT G The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807920000010001",
"intro": "AMS-HT H The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0704920000020002",
"intro": "AMS E The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0706810000010001",
"intro": "AMS G The current sensor of heater 2 is abnormal."
},
{
"ecode": "0705120000020004",
"intro": "AMS F The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1800010000020011",
"intro": "AMS-HT A The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0704010000010003",
"intro": "The AMS E assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706300000010001",
"intro": "The AMS G RFID 1 board has an error."
},
{
"ecode": "1807010000020009",
"intro": "AMS-HT H The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0705130000020004",
"intro": "AMS F The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1802110000020004",
"intro": "AMS-HT C The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0707010000020010",
"intro": "AMS H The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1806100000020004",
"intro": "AMS-HT G The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704810000010004",
"intro": "AMS E The heater 2 heating abnormally."
},
{
"ecode": "1803800000010004",
"intro": "AMS-HT D The heater 1 heating abnormally."
},
{
"ecode": "1801960000010001",
"intro": "AMS-HT B The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0705010000010011",
"intro": "AMS F The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1803010000010005",
"intro": "AMS-HT D The currentsensor of assist motor may be faulty."
},
{
"ecode": "1806010000020006",
"intro": "AMS-HT G The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1807010000010004",
"intro": "The AMS-HT H assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1805930000020002",
"intro": "AMS-HT F The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0704900000020001",
"intro": "AMS E The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0704900000010002",
"intro": "AMS E The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0707100000020004",
"intro": "AMS H The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704920000010001",
"intro": "AMS E The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0707500000020001",
"intro": "AMS H communication is abnormal; please check the connection cable."
},
{
"ecode": "1800800000010001",
"intro": "AMS-HT A The current sensor of heater 1 is abnormal."
},
{
"ecode": "1804010000010004",
"intro": "The AMS-HT E assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1806010000010011",
"intro": "AMS-HT G The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705300000010001",
"intro": "The AMS F RFID 1 board has an error."
},
{
"ecode": "1802120000020004",
"intro": "AMS-HT C The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0707300000010001",
"intro": "The AMS H RFID 1 board has an error."
},
{
"ecode": "0706920000020002",
"intro": "AMS G The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1807800000010004",
"intro": "AMS-HT H The heater 1 heating abnormally."
},
{
"ecode": "0704110000020004",
"intro": "AMS E The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704010000020006",
"intro": "AMS E The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0701550000010003",
"intro": "AMS B was detected offline during the AMS initialization process."
},
{
"ecode": "0707910000020001",
"intro": "AMS H The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0C00010000020008",
"intro": "Failed to get image from liveview camera. Spaghetti and waste chute pileup detection is not available at this time."
},
{
"ecode": "0C00040000020007",
"intro": "BirdsEye Camera is setting up. Please clear all objects and remove the mat. Make sure the marker is not obstructed."
},
{
"ecode": "0700010000010011",
"intro": "AMS A The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1805010000010004",
"intro": "The AMS-HT F assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1800010000010005",
"intro": "AMS-HT A The currentsensor of assist motor may be faulty."
},
{
"ecode": "1804910000020001",
"intro": "AMS-HT E The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0705930000010001",
"intro": "AMS F The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1804900000020001",
"intro": "AMS-HT E The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1807020000010001",
"intro": "AMS-HT H Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1804810000010001",
"intro": "AMS-HT E The current sensor of heater 2 is abnormal."
},
{
"ecode": "1805010000020010",
"intro": "AMS-HT F The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0704010000010001",
"intro": "The AMS E assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1803300000010001",
"intro": "The AMS-HT D RFID 1 board has an error."
},
{
"ecode": "1805910000010002",
"intro": "AMS-HT F The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1806010000020010",
"intro": "AMS-HT G The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0706500000020001",
"intro": "AMS G communication is abnormal; please check the connection cable."
},
{
"ecode": "1807900000010002",
"intro": "AMS-HT H The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1800010000010011",
"intro": "AMS-HT A The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705020000010001",
"intro": "AMS F Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1802920000010001",
"intro": "AMS-HT C The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807100000020004",
"intro": "AMS-HT H The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1801010000020006",
"intro": "AMS-HT B The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0706010000020010",
"intro": "AMS G The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1804020000010001",
"intro": "AMS-HT E Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1805900000010002",
"intro": "AMS-HT F The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0707920000010001",
"intro": "AMS H The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1802010000020006",
"intro": "AMS-HT C The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0705910000020001",
"intro": "AMS F The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0706010000020002",
"intro": "The AMS G assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1800800000010004",
"intro": "AMS-HT A The heater 1 heating abnormally."
},
{
"ecode": "1800300000010001",
"intro": "The AMS-HT A RFID 1 board has an error."
},
{
"ecode": "0707010000010004",
"intro": "The AMS H assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1803900000020001",
"intro": "AMS-HT D The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1804310000010001",
"intro": "The AMS-HT E RFID 2 board has an error."
},
{
"ecode": "1800900000010002",
"intro": "AMS-HT A The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1800920000020002",
"intro": "AMS-HT A The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1806910000020001",
"intro": "AMS-HT G The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0707010000010011",
"intro": "AMS H The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1804930000020002",
"intro": "AMS-HT E The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1802810000010004",
"intro": "AMS-HT C The heater 2 heating abnormally."
},
{
"ecode": "1805100000020004",
"intro": "AMS-HT F The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703300000010001",
"intro": "The AMS D RFID 1 board has an error."
},
{
"ecode": "0703310000010001",
"intro": "The AMS D RFID 2 board has an error."
},
{
"ecode": "0703010000010011",
"intro": "AMS D The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1803010000010003",
"intro": "The AMS-HT D assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0705500000020001",
"intro": "AMS F communication is abnormal; please check the connection cable."
},
{
"ecode": "0705800000010004",
"intro": "AMS F The heater 1 heating abnormally."
},
{
"ecode": "1806920000020002",
"intro": "AMS-HT G The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1804910000010002",
"intro": "AMS-HT E The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1800010000010004",
"intro": "The AMS-HT A assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1802010000020010",
"intro": "AMS-HT C The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0706010000010011",
"intro": "AMS G The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705550000010003",
"intro": "AMS F was detected offline during the AMS initialization process."
},
{
"ecode": "1805010000020011",
"intro": "AMS-HT F The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1806930000020002",
"intro": "AMS-HT G The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1807810000010001",
"intro": "AMS-HT H The current sensor of heater 2 is abnormal."
},
{
"ecode": "1804300000010001",
"intro": "The AMS-HT E RFID 1 board has an error."
},
{
"ecode": "1801920000010001",
"intro": "AMS-HT B The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1807310000010001",
"intro": "The AMS-HT H RFID 2 board has an error."
},
{
"ecode": "1804930000010001",
"intro": "AMS-HT E The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1804010000010005",
"intro": "AMS-HT E The currentsensor of assist motor may be faulty."
},
{
"ecode": "1801910000010002",
"intro": "AMS-HT B The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1804010000010001",
"intro": "The AMS-HT E assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0705810000010001",
"intro": "AMS F The current sensor of heater 2 is abnormal."
},
{
"ecode": "1804010000020010",
"intro": "AMS-HT E The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0705010000020006",
"intro": "AMS F The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0704800000010001",
"intro": "AMS E The current sensor of heater 1 is abnormal."
},
{
"ecode": "0707010000010001",
"intro": "The AMS H assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1805800000010004",
"intro": "AMS-HT F The heater 1 heating abnormally."
},
{
"ecode": "1806010000020009",
"intro": "AMS-HT G The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "1804130000020004",
"intro": "AMS-HT E The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704100000020004",
"intro": "AMS E The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1806110000020004",
"intro": "AMS-HT G The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1805930000010001",
"intro": "AMS-HT F The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0704500000020001",
"intro": "AMS E communication is abnormal; please check the connection cable."
},
{
"ecode": "0704130000020004",
"intro": "AMS E The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704120000020004",
"intro": "AMS E The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1802810000010001",
"intro": "AMS-HT C The current sensor of heater 2 is abnormal."
},
{
"ecode": "1801010000010011",
"intro": "AMS-HT B The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0707130000020004",
"intro": "AMS H The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1804010000010011",
"intro": "AMS-HT E The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1801010000010003",
"intro": "The AMS-HT B assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0706550000010003",
"intro": "AMS G was detected offline during the AMS initialization process."
},
{
"ecode": "1807930000020002",
"intro": "AMS-HT H The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1805020000020002",
"intro": "AMS-HT F The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1803810000010004",
"intro": "AMS-HT D The heater 2 heating abnormally."
},
{
"ecode": "1806920000010001",
"intro": "AMS-HT G The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "1804020000020002",
"intro": "AMS-HT E The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1800500000020001",
"intro": "AMS-HT A communication is abnormal; please check the connection cable."
},
{
"ecode": "0705010000020010",
"intro": "AMS F The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1805500000020001",
"intro": "AMS-HT F communication is abnormal; please check the connection cable."
},
{
"ecode": "0707900000020001",
"intro": "AMS H The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "1806900000010002",
"intro": "AMS-HT G The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0707550000010003",
"intro": "AMS H was detected offline during the AMS initialization process."
},
{
"ecode": "1802500000020001",
"intro": "AMS-HT C communication is abnormal; please check the connection cable."
},
{
"ecode": "1802100000020004",
"intro": "AMS-HT C The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1802930000020002",
"intro": "AMS-HT C The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1801810000010004",
"intro": "AMS-HT B The heater 2 heating abnormally."
},
{
"ecode": "1806810000010001",
"intro": "AMS-HT G The current sensor of heater 2 is abnormal."
},
{
"ecode": "0706010000010004",
"intro": "The AMS G assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1802010000010011",
"intro": "AMS-HT C The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0705010000010003",
"intro": "The AMS F assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1807800000010001",
"intro": "AMS-HT H The current sensor of heater 1 is abnormal."
},
{
"ecode": "1800810000010004",
"intro": "AMS-HT A The heater 2 heating abnormally."
},
{
"ecode": "0706800000010001",
"intro": "AMS G The current sensor of heater 1 is abnormal."
},
{
"ecode": "1806130000020004",
"intro": "AMS-HT G The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0704800000010004",
"intro": "AMS E The heater 1 heating abnormally."
},
{
"ecode": "1801930000020002",
"intro": "AMS-HT B The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1802010000010004",
"intro": "The AMS-HT C assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1802010000020002",
"intro": "The AMS-HT C assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1801010000010001",
"intro": "The AMS-HT B assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0706020000020002",
"intro": "AMS G The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "1802960000010001",
"intro": "AMS-HT C The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0707920000020002",
"intro": "AMS H The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1803920000020002",
"intro": "AMS-HT D The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0500010000030007",
"intro": "Unable to record time-lapse photography without USB flash drive inserted."
},
{
"ecode": "0300110000020002",
"intro": "The resonance frequency of the Y-axis differs greatly from the last calibration. Please clean the Y-axis liner rod and conduct a calibration after printing."
},
{
"ecode": "0300200000010002",
"intro": "Y-axis homing abnormal: please check if the toolhead is stuck or the Y carriage has too much resistance."
},
{
"ecode": "0C00010000010001",
"intro": "Toolhead camera is offline. Please check the hardware connection."
},
{
"ecode": "0C00010000010003",
"intro": "Synchronization between the Toolhead camera and MC is abnormal. Please restart your printer."
},
{
"ecode": "0C00010000010004",
"intro": "Toolhead camera lens seems to be dirty. Please clean the lens."
},
{
"ecode": "0C00010000010005",
"intro": "Toolhead camera parameter is abnormal. Please contact after-sales."
},
{
"ecode": "0C00010000020006",
"intro": "Toolhead camera parameter is abnormal. Please enable flowrate calibration in the next print."
},
{
"ecode": "07FE810000020001",
"intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead."
},
{
"ecode": "07FE810000010001",
"intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "07FE810000010002",
"intro": "The position hall sensor of the extruder switching motor is abnormal. Please check whether the connecting cable is loose."
},
{
"ecode": "07FE800000010001",
"intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "07FF810000010001",
"intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "07FF800000010001",
"intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose."
},
{
"ecode": "07FF810000010002",
"intro": "The position hall sensor of the extruder switching motor is abnormal. Please check whether the connecting cable is loose."
},
{
"ecode": "0500060000020032",
"intro": "Nozzle camera binding failed. Please check the hardware and cable connections."
},
{
"ecode": "07FF810000020001",
"intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead."
},
{
"ecode": "0500060000020031",
"intro": "Toolhead camera binding failed. Please check the hardware and cable connections."
},
{
"ecode": "0500030000010026",
"intro": "The Toolhead expansion module is malfunctioning. Please power off, check the connection, and restart the device."
},
{
"ecode": "07FE800000010002",
"intro": "The toolhead lift motor position hall sensor is abnormal, please check whether the connecting cable is loose."
},
{
"ecode": "07FF800000010002",
"intro": "The toolhead lift motor position hall sensor is abnormal, please check whether the connecting cable is loose."
},
{
"ecode": "07FF810000010003",
"intro": "The position hall signal communication acquisition of the extruder switching motor is abnormal."
},
{
"ecode": "0300200000010001",
"intro": "X-axis homing abnormal: please check if the toolhead is stuck or if the resistance on the X-axis linear rail is too high."
},
{
"ecode": "0300100000020002",
"intro": "The resonance frequency of the X-axis differs significantly from the last calibration. Please clean the X-axis linear rail and conduct a calibration after printing."
},
{
"ecode": "0500030000010007",
"intro": "The Toolhead expansion module is malfunctioning. Please power off, check the connection, and restart the device."
},
{
"ecode": "07FE810000010003",
"intro": "The position hall signal communication acquisition of the extruder switching motor is abnormal."
},
{
"ecode": "03001E0000010003",
"intro": "The left extruder nozzle temperature is abnormal; the heater is over temperature."
},
{
"ecode": "03001E0000010007",
"intro": "The left extruder nozzle temperature is abnormal; the sensor may have an open circuit."
},
{
"ecode": "03001E0000010001",
"intro": "The left extruder nozzle temperature is abnormal; the heater may have a short circuit."
},
{
"ecode": "03001E0000010002",
"intro": "The left extruder nozzle temperature is abnormal; the heater may have an open circuit."
},
{
"ecode": "0300020000010001",
"intro": "The right extruder nozzle temperature is abnormal; the heater may have a short circuit."
},
{
"ecode": "0300020000010003",
"intro": "The right extruder nozzle temperature is abnormal; the heater is over temperature."
},
{
"ecode": "0300020000010002",
"intro": "The right extruder nozzle temperature is abnormal; the heater may have an open circuit."
},
{
"ecode": "0300020000010007",
"intro": "The right extruder nozzle temperature is abnormal; the sensor may have an open circuit."
},
{
"ecode": "0300990000010004",
"intro": "It is detected that the laser protective glass is not installed on the right side window. Please install the protective glass according to the instructions and re-initiate the task."
},
{
"ecode": "07FF200000020004",
"intro": "Please pull the external filament from the right extruder."
},
{
"ecode": "0300960000010004",
"intro": "It is detected that the laser protective glass is not installed on the front door. Please install the protective glass according to the instructions and re-initiate the task."
},
{
"ecode": "07FF200000020001",
"intro": "External filament of right extruder has run out; please load a new filament."
},
{
"ecode": "0300970000010004",
"intro": "It is detected that the laser protective glass is not installed on the top cover. Please install the protective glass according to the instructions and re-initiate the task."
},
{
"ecode": "0300980000010004",
"intro": "It is detected that the laser protective glass is not installed on the left side window. Please install the protective glass according to the instructions and re-initiate the task."
},
{
"ecode": "0300990000030001",
"intro": "The right side window is detected to be open."
},
{
"ecode": "0500040000020039",
"intro": "Please plug in the module connector"
},
{
"ecode": "0C00040000020019",
"intro": "The birdseye camera is installed offset. Please refer to the guide to reinstall it."
},
{
"ecode": "0C00040000030018",
"intro": "The toolhead camera calibration failed, probably because the material was not tightly adhered. The default parameters were used for this cutting."
},
{
"ecode": "0701010000010001",
"intro": "The AMS B assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1200220000020006",
"intro": "Failed to extrude AMS A Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1201220000020005",
"intro": "AMS B Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1202110000010003",
"intro": "The AMS C Slot2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1203820000020001",
"intro": "AMS D Slot3 filament may be tangled or stuck."
},
{
"ecode": "0701960000010001",
"intro": "AMS B The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0700100000020004",
"intro": "AMS A The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0702010000020002",
"intro": "The AMS C assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201300000010001",
"intro": "AMS B Slot 1 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1201320000010001",
"intro": "AMS B Slot 3 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202210000020002",
"intro": "AMS C Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1202210000020005",
"intro": "AMS C Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1202230000030002",
"intro": "AMS C Slot4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203300000010001",
"intro": "AMS D Slot 1 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "0703010000010005",
"intro": "AMS D The currentsensor of assist motor may be faulty."
},
{
"ecode": "0703800000010001",
"intro": "AMS D The current sensor of heater 1 is abnormal."
},
{
"ecode": "0300010000010001",
"intro": "The heatbed temperature is abnormal; the heater may have a short circuit."
},
{
"ecode": "0703810000010001",
"intro": "AMS D The current sensor of heater 2 is abnormal."
},
{
"ecode": "0702010000010001",
"intro": "The AMS C assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1200330000020002",
"intro": "The RFID-tag on AMS A Slot 4 is damaged."
},
{
"ecode": "1201200000030001",
"intro": "AMS B Slot1 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1201220000020003",
"intro": "AMS B Slot3 filament may be broken in the PTFE tube."
},
{
"ecode": "1201230000020004",
"intro": "AMS B Slot4 filament may be broken in the tool head."
},
{
"ecode": "1202130000010001",
"intro": "The AMS C Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1202720000010001",
"intro": "AMS C Filament speed and length error: The slot 3 filament odometry may be faulty."
},
{
"ecode": "1203200000020001",
"intro": "AMS D Slot1 filament has run out; please insert a new filament."
},
{
"ecode": "1203210000020004",
"intro": "AMS D Slot2 filament may be broken in the tool head."
},
{
"ecode": "0C0003000003000B",
"intro": "Inspecting the first layer: please wait a moment."
},
{
"ecode": "0701900000020001",
"intro": "AMS B The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0702920000010001",
"intro": "AMS C The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0300360000020002",
"intro": "The Chamber Heat Circulation Fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "1200100000020002",
"intro": "The AMS A Slot1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200200000020003",
"intro": "AMS A Slot1 filament may be broken in the PTFE tube."
},
{
"ecode": "1200720000010001",
"intro": "AMS A Filament speed and length error: The slot 3 filament odometry may be faulty."
},
{
"ecode": "1200830000020001",
"intro": "AMS A Slot4 filament may be tangled or stuck."
},
{
"ecode": "1202300000020002",
"intro": "The RFID-tag on AMS C Slot 1 is damaged."
},
{
"ecode": "1202320000010001",
"intro": "AMS C Slot 3 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202830000020001",
"intro": "AMS C Slot4 filament may be tangled or stuck."
},
{
"ecode": "0C00040000020001",
"intro": "Laser base not detected. Please place it and continue."
},
{
"ecode": "0702900000010002",
"intro": "AMS C The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0701010000020010",
"intro": "AMS B The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1200230000030002",
"intro": "AMS A Slot4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1202120000010001",
"intro": "The AMS C Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1202210000020001",
"intro": "AMS C Slot2 filament has run out; please insert a new filament."
},
{
"ecode": "1202230000020004",
"intro": "AMS C Slot4 filament may be broken in the tool head."
},
{
"ecode": "1202230000030001",
"intro": "AMS C Slot4 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1203100000010001",
"intro": "The AMS D Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1203110000010003",
"intro": "The AMS D Slot2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1203220000020005",
"intro": "AMS D Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "0703800000010004",
"intro": "AMS D The heater 1 heating abnormally."
},
{
"ecode": "0703010000020009",
"intro": "AMS D The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0C0003000001000A",
"intro": "Your printer is in factory mode. Please contact Technical Support."
},
{
"ecode": "050004000002001A",
"intro": "The RFID-tag on AMS C Slot3 cannot be identified."
},
{
"ecode": "1200200000020006",
"intro": "Failed to extrude AMS A Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1200820000020001",
"intro": "AMS A Slot3 filament may be tangled or stuck."
},
{
"ecode": "1201220000020004",
"intro": "AMS B Slot3 filament may be broken in the tool head."
},
{
"ecode": "1202330000020002",
"intro": "The RFID-tag on AMS C Slot 4 is damaged."
},
{
"ecode": "1203130000010003",
"intro": "The AMS D Slot4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0700130000020004",
"intro": "AMS A The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703910000010002",
"intro": "AMS D The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0700920000020002",
"intro": "AMS A The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0702910000020001",
"intro": "AMS C The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0703110000020004",
"intro": "AMS D The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0701010000020011",
"intro": "AMS B The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0700810000010001",
"intro": "AMS A The current sensor of heater 2 is abnormal."
},
{
"ecode": "1200210000030001",
"intro": "AMS A Slot2 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1201200000020003",
"intro": "AMS B Slot1 filament may be broken in the PTFE tube."
},
{
"ecode": "1202710000010001",
"intro": "AMS C Filament speed and length error: The slot 2 filament odometry may be faulty."
},
{
"ecode": "1203120000020002",
"intro": "The AMS D Slot3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0300280000010004",
"intro": "The eddy current sensor data is too low when the cutter returns to zero."
},
{
"ecode": "0703130000020004",
"intro": "AMS D The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0300330000020002",
"intro": "The Chamber Exhaust Fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "0500040000020032",
"intro": "Please slide in Laser Module and lock the quick-release lever."
},
{
"ecode": "0701920000010001",
"intro": "AMS B The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0701900000010002",
"intro": "AMS B The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0701020000010001",
"intro": "AMS B Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0702010000010003",
"intro": "The AMS C assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1202220000030002",
"intro": "AMS C Slot3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1202230000020002",
"intro": "AMS C Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0702920000020002",
"intro": "AMS C The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0701930000010001",
"intro": "AMS B The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0700010000010004",
"intro": "The AMS A assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "0700500000020001",
"intro": "AMS A communication is abnormal; please check the connection cable."
},
{
"ecode": "1200120000020002",
"intro": "The AMS A Slot3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200220000020002",
"intro": "AMS A Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1202200000020002",
"intro": "AMS C Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1202230000020003",
"intro": "AMS C Slot4 filament may be broken in the PTFE tube."
},
{
"ecode": "1203200000020002",
"intro": "AMS D Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1203210000020001",
"intro": "AMS D Slot2 filament has run out; please insert a new filament."
},
{
"ecode": "0702110000020004",
"intro": "AMS C The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703910000020001",
"intro": "AMS D The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0500040000020015",
"intro": "The RFID-tag on AMS B Slot2 cannot be identified."
},
{
"ecode": "0702020000010001",
"intro": "AMS C Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1200710000010001",
"intro": "AMS A Filament speed and length error: The slot 2 filament odometry may be faulty."
},
{
"ecode": "1201130000010001",
"intro": "The AMS B Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1201300000030003",
"intro": "AMS B Slot1 RFID cannot be read because of a structural error."
},
{
"ecode": "1201330000010001",
"intro": "AMS B Slot 4 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202100000010003",
"intro": "The AMS C Slot1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1202220000020002",
"intro": "AMS C Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1202310000030003",
"intro": "AMS C Slot2 RFID cannot be read because of a structural error."
},
{
"ecode": "1203220000020004",
"intro": "AMS D Slot3 filament may be broken in the tool head."
},
{
"ecode": "1200230000020003",
"intro": "AMS A Slot4 filament may be broken in the PTFE tube."
},
{
"ecode": "1200230000020004",
"intro": "AMS A Slot4 filament may be broken in the tool head."
},
{
"ecode": "1200330000010001",
"intro": "AMS A Slot 4 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1201200000020002",
"intro": "AMS B Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1202220000020001",
"intro": "AMS C Slot3 filament has run out; please insert a new filament."
},
{
"ecode": "1203200000030001",
"intro": "AMS D Slot1 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "0300350000020002",
"intro": "The MC module cooling fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "0703020000020002",
"intro": "AMS D The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "0C00040000020004",
"intro": "The type of platform is not supported for this task. Please use the correct platform to continue."
},
{
"ecode": "1200210000020003",
"intro": "AMS A Slot2 filament may be broken in the PTFE tube."
},
{
"ecode": "1200220000020005",
"intro": "AMS A Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1200230000030001",
"intro": "AMS A Slot4 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1200300000010001",
"intro": "AMS A Slot 1 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1201200000020004",
"intro": "AMS B Slot1 filament may be broken in the tool head."
},
{
"ecode": "1201220000020002",
"intro": "AMS B Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1201230000020003",
"intro": "AMS B Slot4 filament may be broken in the PTFE tube."
},
{
"ecode": "1201320000030003",
"intro": "AMS B Slot3 RFID cannot be read because of a structural error."
},
{
"ecode": "1203230000020004",
"intro": "AMS D Slot4 filament may be broken in the tool head."
},
{
"ecode": "1203230000020005",
"intro": "AMS D Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "0701810000010004",
"intro": "AMS B The heater 2 heating abnormally."
},
{
"ecode": "0702910000010002",
"intro": "AMS C The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0700020000020002",
"intro": "AMS A The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "050004000002001C",
"intro": "The RFID-tag on AMS D Slot1 cannot be identified."
},
{
"ecode": "1200110000010001",
"intro": "The AMS A Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1200230000020002",
"intro": "AMS A Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1200310000020002",
"intro": "The RFID-tag on AMS A Slot 2 is damaged."
},
{
"ecode": "1200500000020001",
"intro": "AMS A communication is abnormal; please check the connection cable."
},
{
"ecode": "1201210000020006",
"intro": "Failed to extrude AMS B Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1202100000020002",
"intro": "The AMS C Slot1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1203110000010001",
"intro": "The AMS D Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "0701800000010004",
"intro": "AMS B The heater 1 heating abnormally."
},
{
"ecode": "0703010000020011",
"intro": "AMS D The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0701910000020001",
"intro": "AMS B The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0300320000020002",
"intro": "The Auxiliary Part Cooling Fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "0701110000020004",
"intro": "AMS B The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703930000010001",
"intro": "AMS D The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0700200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "0702200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "1200220000030001",
"intro": "AMS A Slot3 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1200800000020001",
"intro": "AMS A Slot1 filament may be tangled or stuck."
},
{
"ecode": "1201200000020001",
"intro": "AMS B Slot1 filament has run out; please insert a new filament."
},
{
"ecode": "1201200000020006",
"intro": "Failed to extrude AMS B Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1201210000020001",
"intro": "AMS B Slot2 filament has run out; please insert a new filament."
},
{
"ecode": "1201220000030001",
"intro": "AMS B Slot3 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1202200000020006",
"intro": "Failed to extrude AMS C Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1202500000020001",
"intro": "AMS C communication is abnormal; please check the connection cable."
},
{
"ecode": "0703010000020010",
"intro": "AMS D The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0700010000020010",
"intro": "AMS A The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "0701100000020004",
"intro": "AMS B The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1201300000020002",
"intro": "The RFID-tag on AMS B Slot 1 is damaged."
},
{
"ecode": "1201310000030003",
"intro": "AMS B Slot2 RFID cannot be read because of a structural error."
},
{
"ecode": "1201710000010001",
"intro": "AMS B Filament speed and length error: The slot 2 filament odometry may be faulty."
},
{
"ecode": "1202130000010003",
"intro": "The AMS C Slot4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1202200000030002",
"intro": "AMS C Slot1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1202220000020005",
"intro": "AMS C Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1203330000030003",
"intro": "AMS D Slot4 RFID cannot be read because of a structural error."
},
{
"ecode": "0700930000020002",
"intro": "AMS A The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0702010000020011",
"intro": "AMS C The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "0300960000030001",
"intro": "The front door is open."
},
{
"ecode": "050003000002000C",
"intro": "Wireless hardware error: please turn off/on WiFi or restart the device."
},
{
"ecode": "0700010000020006",
"intro": "AMS A The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0300090000020001",
"intro": "The extrusion motor is overloaded. The extruder may be clogged or the filament may be stuck in the tool head."
},
{
"ecode": "0703930000020002",
"intro": "AMS D The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "1200200000030001",
"intro": "AMS A Slot1 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1201700000010001",
"intro": "AMS B Filament speed and length error: The slot 1 filament odometry may be faulty."
},
{
"ecode": "1201730000010001",
"intro": "AMS B Filament speed and length error: The slot 4 filament odometry may be faulty."
},
{
"ecode": "1202220000030001",
"intro": "AMS C Slot3 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1202310000020002",
"intro": "The RFID-tag on AMS C Slot 2 is damaged."
},
{
"ecode": "1202320000020002",
"intro": "The RFID-tag on AMS C Slot 3 is damaged."
},
{
"ecode": "1203220000020002",
"intro": "AMS D Slot 3 is empty; please insert a new filament."
},
{
"ecode": "1203220000020006",
"intro": "Failed to extrude AMS D Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1203230000020002",
"intro": "AMS D Slot 4 is empty; please insert a new filament."
},
{
"ecode": "0C00040000010015",
"intro": "Laser Protective Insert not detected. Please place it and continue."
},
{
"ecode": "0703120000020004",
"intro": "AMS D The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0700800000010001",
"intro": "AMS A The current sensor of heater 1 is abnormal."
},
{
"ecode": "0300A30000010002",
"intro": "The plate is in wrong position. Please place it correctly."
},
{
"ecode": "0701010000020006",
"intro": "AMS B The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0500040000020011",
"intro": "The RFID-tag on AMS A Slot2 cannot be identified."
},
{
"ecode": "0500040000020017",
"intro": "The RFID-tag on AMS B Slot4 cannot be identified."
},
{
"ecode": "0701500000020001",
"intro": "AMS B communication is abnormal; please check the connection cable."
},
{
"ecode": "1200120000010003",
"intro": "The AMS A Slot3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1200320000010001",
"intro": "AMS A Slot 3 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202300000030003",
"intro": "AMS C Slot1 RFID cannot be read because of a structural error."
},
{
"ecode": "1203700000010001",
"intro": "AMS D Filament speed and length error: The slot 1 filament odometry may be faulty."
},
{
"ecode": "1203800000020001",
"intro": "AMS D Slot1 filament may be tangled or stuck."
},
{
"ecode": "0701010000020009",
"intro": "AMS B The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0701020000020002",
"intro": "AMS B The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "0500040000020018",
"intro": "The RFID-tag on AMS C Slot1 cannot be identified."
},
{
"ecode": "0703010000010003",
"intro": "The AMS D assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1200220000020001",
"intro": "AMS A Slot3 filament has run out; please insert a new filament."
},
{
"ecode": "1201210000020002",
"intro": "AMS B Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1201220000020001",
"intro": "AMS B Slot3 filament has run out; please insert a new filament."
},
{
"ecode": "1203200000020004",
"intro": "AMS D Slot1 filament may be broken in the tool head."
},
{
"ecode": "1203300000030003",
"intro": "AMS D Slot1 RFID cannot be read because of a structural error."
},
{
"ecode": "07FE200000020004",
"intro": "Please pull the external filament from the left extruder."
},
{
"ecode": "1200210000020006",
"intro": "Failed to extrude AMS A Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1201210000020004",
"intro": "AMS B Slot2 filament may be broken in the tool head."
},
{
"ecode": "1201210000020005",
"intro": "AMS B Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1202210000030002",
"intro": "AMS C Slot2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1202220000020006",
"intro": "Failed to extrude AMS C Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1202230000020006",
"intro": "Failed to extrude AMS C Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1203200000030002",
"intro": "AMS D Slot1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203220000030002",
"intro": "AMS D Slot3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203320000010001",
"intro": "AMS D Slot 3 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1203330000010001",
"intro": "AMS D Slot 4 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "0703810000010004",
"intro": "AMS D The heater 2 heating abnormally."
},
{
"ecode": "0701810000010001",
"intro": "AMS B The current sensor of heater 2 is abnormal."
},
{
"ecode": "0701120000020004",
"intro": "AMS B The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0703900000010002",
"intro": "AMS D The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "1200110000010003",
"intro": "The AMS A Slot2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1201820000020001",
"intro": "AMS B Slot3 filament may be tangled or stuck."
},
{
"ecode": "1202130000020002",
"intro": "The AMS C Slot4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0702120000020004",
"intro": "AMS C The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0702810000010001",
"intro": "AMS C The current sensor of heater 2 is abnormal."
},
{
"ecode": "0702800000010001",
"intro": "AMS C The current sensor of heater 1 is abnormal."
},
{
"ecode": "0702010000010005",
"intro": "AMS C The currentsensor of assist motor may be faulty."
},
{
"ecode": "0703960000010001",
"intro": "AMS D The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0701010000010005",
"intro": "AMS B The currentsensor of assist motor may be faulty."
},
{
"ecode": "0700010000010003",
"intro": "The AMS A assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "0701700000020061",
"intro": "AMS B Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "0703020000010001",
"intro": "AMS D Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "1200100000010001",
"intro": "The AMS A Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1200210000020001",
"intro": "AMS A Slot2 filament has run out; please insert a new filament."
},
{
"ecode": "1200220000030002",
"intro": "AMS A Slot3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1201230000030001",
"intro": "AMS B Slot4 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1201330000020002",
"intro": "The RFID-tag on AMS B Slot 4 is damaged."
},
{
"ecode": "1202110000020002",
"intro": "The AMS C Slot2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1202120000020002",
"intro": "The AMS C Slot3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0700010000020009",
"intro": "AMS A The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "0701010000020002",
"intro": "The AMS B assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200220000020004",
"intro": "AMS A Slot3 filament may be broken in the tool head."
},
{
"ecode": "1201130000010003",
"intro": "The AMS B Slot4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1203230000020003",
"intro": "AMS D Slot4 filament may be broken in the PTFE tube."
},
{
"ecode": "0700810000010004",
"intro": "AMS A The heater 2 heating abnormally."
},
{
"ecode": "050004000002001F",
"intro": "The RFID-tag on AMS D Slot4 cannot be identified."
},
{
"ecode": "0701200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "1200130000010001",
"intro": "The AMS A Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1201210000020003",
"intro": "AMS B Slot2 filament may be broken in the PTFE tube."
},
{
"ecode": "1201220000020006",
"intro": "Failed to extrude AMS B Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1201230000020001",
"intro": "AMS B Slot4 filament has run out; please insert a new filament."
},
{
"ecode": "1201230000020006",
"intro": "Failed to extrude AMS B Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1202120000010003",
"intro": "The AMS C Slot3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1202210000020006",
"intro": "Failed to extrude AMS C Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1203200000020006",
"intro": "Failed to extrude AMS D Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1203210000030002",
"intro": "AMS D Slot2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203720000010001",
"intro": "AMS D Filament speed and length error: The slot 3 filament odometry may be faulty."
},
{
"ecode": "0702810000010004",
"intro": "AMS C The heater 2 heating abnormally."
},
{
"ecode": "07FE200000020001",
"intro": "External filament of left extruder has run out; please load a new filament."
},
{
"ecode": "0700910000010002",
"intro": "AMS A The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0500040000020013",
"intro": "The RFID-tag on AMS A Slot4 cannot be identified."
},
{
"ecode": "1200130000020002",
"intro": "The AMS A Slot4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201220000030002",
"intro": "AMS B Slot3 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1201720000010001",
"intro": "AMS B Filament speed and length error: The slot 3 filament odometry may be faulty."
},
{
"ecode": "1202330000030003",
"intro": "AMS C Slot4 RFID cannot be read because of a structural error."
},
{
"ecode": "1203130000010001",
"intro": "The AMS D Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1203210000020003",
"intro": "AMS D Slot2 filament may be broken in the PTFE tube."
},
{
"ecode": "1203210000030001",
"intro": "AMS D Slot2 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1203230000030001",
"intro": "AMS D Slot4 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "0700960000010001",
"intro": "AMS A The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0703010000020006",
"intro": "AMS D The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "0500040000020010",
"intro": "The RFID-tag on AMS A Slot1 cannot be identified."
},
{
"ecode": "050004000002001E",
"intro": "The RFID-tag on AMS D Slot3 cannot be identified."
},
{
"ecode": "0700010000010001",
"intro": "The AMS A assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "1200200000020005",
"intro": "AMS A Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1200320000020002",
"intro": "The RFID-tag on AMS A Slot 3 is damaged."
},
{
"ecode": "1202200000020005",
"intro": "AMS C Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1202210000030001",
"intro": "AMS C Slot2 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1202320000030003",
"intro": "AMS C Slot3 RFID cannot be read because of a structural error."
},
{
"ecode": "1203300000020002",
"intro": "The RFID-tag on AMS D Slot 1 is damaged."
},
{
"ecode": "1203330000020002",
"intro": "The RFID-tag on AMS D Slot 4 is damaged."
},
{
"ecode": "0703100000020004",
"intro": "AMS D The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0C00040000020002",
"intro": "Cutting mat not detected. Please place the required mat for the task and continue."
},
{
"ecode": "0C00040000020008",
"intro": "Material not detected. Please confirm placement and continue."
},
{
"ecode": "0701930000020002",
"intro": "AMS B The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0702500000020001",
"intro": "AMS C communication is abnormal; please check the connection cable."
},
{
"ecode": "1201120000010003",
"intro": "The AMS B Slot3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1201200000020005",
"intro": "AMS B Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1203100000010003",
"intro": "The AMS D Slot1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1203110000020002",
"intro": "The AMS D Slot2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "0300270000010001",
"intro": "The nozzle offset calibration sensor frequency is too low. The sensor may be damaged."
},
{
"ecode": "0700110000020004",
"intro": "AMS A The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0300310000020002",
"intro": "The Part Cooling Fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "0702960000010001",
"intro": "AMS C The drying process may experience thermal runaway. Please turn off the AMS power supply."
},
{
"ecode": "0700120000020004",
"intro": "AMS A The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "1200230000020006",
"intro": "Failed to extrude AMS A Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1201810000020001",
"intro": "AMS B Slot2 filament may be tangled or stuck."
},
{
"ecode": "1202220000020003",
"intro": "AMS C Slot3 filament may be broken in the PTFE tube."
},
{
"ecode": "1202230000020005",
"intro": "AMS C Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1203220000020001",
"intro": "AMS D Slot3 filament has run out; please insert a new filament."
},
{
"ecode": "1203230000030002",
"intro": "AMS D Slot4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203310000010001",
"intro": "AMS D Slot 2 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "0300280000010001",
"intro": "The eddy current sensor data is too high when the cutter returns to zero."
},
{
"ecode": "0300270000010007",
"intro": "The nozzle offset calibration sensor frequency is too high. The sensor may be damaged."
},
{
"ecode": "0702700000020061",
"intro": "AMS C Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "0703010000010001",
"intro": "The AMS D assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin."
},
{
"ecode": "0703200000020006",
"intro": "PTFE tube detached during the feeding process. Please check if the PTFE tube is connected from AMS to extruder"
},
{
"ecode": "1200200000020001",
"intro": "AMS A Slot1 filament has run out; please insert a new filament."
},
{
"ecode": "1200210000030002",
"intro": "AMS A Slot2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1201230000030002",
"intro": "AMS B Slot4 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203810000020001",
"intro": "AMS D Slot2 filament may be tangled or stuck."
},
{
"ecode": "1203830000020001",
"intro": "AMS D Slot4 filament may be tangled or stuck."
},
{
"ecode": "0700800000010004",
"intro": "AMS A The heater 1 heating abnormally."
},
{
"ecode": "0C00040000010016",
"intro": "Quick-release Lever is not locked. Please push it down to secure."
},
{
"ecode": "0701920000020002",
"intro": "AMS B The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0702130000020004",
"intro": "AMS C The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0500040000020019",
"intro": "The RFID-tag on AMS C Slot2 cannot be identified."
},
{
"ecode": "0703500000020001",
"intro": "AMS D communication is abnormal; please check the connection cable."
},
{
"ecode": "0703700000020061",
"intro": "AMS D Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "1200130000010003",
"intro": "The AMS A Slot4 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1200220000020003",
"intro": "AMS A Slot3 filament may be broken in the PTFE tube."
},
{
"ecode": "1202210000020003",
"intro": "AMS C Slot2 filament may be broken in the PTFE tube."
},
{
"ecode": "1202230000020001",
"intro": "AMS C Slot4 filament has run out; please insert a new filament."
},
{
"ecode": "1203120000010001",
"intro": "The AMS D Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1203710000010001",
"intro": "AMS D Filament speed and length error: The slot 2 filament odometry may be faulty."
},
{
"ecode": "1200210000020005",
"intro": "AMS A Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1201100000010003",
"intro": "The AMS B Slot1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1201100000020002",
"intro": "The AMS B Slot1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201310000020002",
"intro": "The RFID-tag on AMS B Slot 2 is damaged."
},
{
"ecode": "1201800000020001",
"intro": "AMS B Slot1 filament may be tangled or stuck."
},
{
"ecode": "1202800000020001",
"intro": "AMS C Slot1 filament may be tangled or stuck."
},
{
"ecode": "1203220000020003",
"intro": "AMS D Slot3 filament may be broken in the PTFE tube."
},
{
"ecode": "1203310000020002",
"intro": "The RFID-tag on AMS D Slot 2 is damaged."
},
{
"ecode": "1203320000020002",
"intro": "The RFID-tag on AMS D Slot 3 is damaged."
},
{
"ecode": "1203320000030003",
"intro": "AMS D Slot3 RFID cannot be read because of a structural error."
},
{
"ecode": "0703920000010001",
"intro": "AMS D The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0702010000020006",
"intro": "AMS C The assist motor three-phase wires are not connected. The asssist motor connector may have poor contact."
},
{
"ecode": "1201110000010003",
"intro": "The AMS B Slot2 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1201120000020002",
"intro": "The AMS B Slot3 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201230000020002",
"intro": "AMS B Slot 4 is empty; please insert a new filament."
},
{
"ecode": "1201230000020005",
"intro": "AMS B Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1201830000020001",
"intro": "AMS B Slot4 filament may be tangled or stuck."
},
{
"ecode": "1202200000020004",
"intro": "AMS C Slot1 filament may be broken in the tool head."
},
{
"ecode": "1202730000010001",
"intro": "AMS C Filament speed and length error: The slot 4 filament odometry may be faulty."
},
{
"ecode": "1203120000010003",
"intro": "The AMS D Slot3 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1203210000020006",
"intro": "Failed to extrude AMS D Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "1203500000020001",
"intro": "AMS D communication is abnormal; please check the connection cable."
},
{
"ecode": "0C00040000020003",
"intro": "The laser work base is not properly aligned. Please ensure all four corners are aligned with the heatbed."
},
{
"ecode": "0702010000020009",
"intro": "AMS C The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty."
},
{
"ecode": "050004000002001B",
"intro": "The RFID-tag on AMS C Slot4 cannot be identified."
},
{
"ecode": "050004000002001D",
"intro": "The RFID-tag on AMS D Slot2 cannot be identified."
},
{
"ecode": "1201210000030002",
"intro": "AMS B Slot2 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1203100000020002",
"intro": "The AMS D Slot1 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1203210000020002",
"intro": "AMS D Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1203230000020001",
"intro": "AMS D Slot4 filament has run out; please insert a new filament."
},
{
"ecode": "1203310000030003",
"intro": "AMS D Slot2 RFID cannot be read because of a structural error."
},
{
"ecode": "0702020000020002",
"intro": "AMS C The odometer has no signal. The odometer connector may have poor contact."
},
{
"ecode": "0703920000020002",
"intro": "AMS D The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0700020000010001",
"intro": "AMS A Filament speed and length error: The filament odometry may be faulty."
},
{
"ecode": "0702010000010004",
"intro": "The AMS C assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "0703010000010004",
"intro": "The AMS D assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1202110000010001",
"intro": "The AMS C Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1202200000020001",
"intro": "AMS C Slot1 filament has run out; please insert a new filament."
},
{
"ecode": "1202700000010001",
"intro": "AMS C Filament speed and length error: The slot 1 filament odometry may be faulty."
},
{
"ecode": "1203200000020003",
"intro": "AMS D Slot1 filament may be broken in the PTFE tube."
},
{
"ecode": "1203200000020005",
"intro": "AMS D Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "050003000001000B",
"intro": "The screen is malfunctioning; please restart the device."
},
{
"ecode": "0C00040000020009",
"intro": "Material position detected in blind spot. Please do not place material too far towards the edge of the device."
},
{
"ecode": "0500040000020016",
"intro": "The RFID-tag on AMS B Slot3 cannot be identified."
},
{
"ecode": "0701010000010003",
"intro": "The AMS B assist motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1200200000020002",
"intro": "AMS A Slot 1 is empty; please insert a new filament."
},
{
"ecode": "1200200000030002",
"intro": "AMS A Slot1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1200210000020002",
"intro": "AMS A Slot 2 is empty; please insert a new filament."
},
{
"ecode": "1200700000010001",
"intro": "AMS A Filament speed and length error: The slot 1 filament odometry may be faulty."
},
{
"ecode": "1201110000010001",
"intro": "The AMS B Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1201120000010001",
"intro": "The AMS B Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1201320000020002",
"intro": "The RFID-tag on AMS B Slot 3 is damaged."
},
{
"ecode": "1202330000010001",
"intro": "AMS C Slot 4 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "0702930000020002",
"intro": "AMS C The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance."
},
{
"ecode": "0701910000010002",
"intro": "AMS B The coil of exhaust valve 2 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0702010000020010",
"intro": "AMS C The assist motor resistance is abnormal. The assist motor may be faulty."
},
{
"ecode": "1200300000030003",
"intro": "AMS A Slot1 RFID cannot be read because of a structural error."
},
{
"ecode": "1201210000030001",
"intro": "AMS B Slot2 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1201500000020001",
"intro": "AMS B communication is abnormal; please check the connection cable."
},
{
"ecode": "1202210000020004",
"intro": "AMS C Slot2 filament may be broken in the tool head."
},
{
"ecode": "1202310000010001",
"intro": "AMS C Slot 2 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1203730000010001",
"intro": "AMS D Filament speed and length error: The slot 4 filament odometry may be faulty."
},
{
"ecode": "0701800000010001",
"intro": "AMS B The current sensor of heater 1 is abnormal."
},
{
"ecode": "0703900000020001",
"intro": "AMS D The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0700700000020061",
"intro": "AMS A Assisting extruder grab filament failed, possibly due to excessive resistance from the buffer. Please check if the buffer is stuck, if the filament spool is tilted, and if the filament tube is clear."
},
{
"ecode": "0703010000020002",
"intro": "The AMS D assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200210000020004",
"intro": "AMS A Slot2 filament may be broken in the tool head."
},
{
"ecode": "1200230000020005",
"intro": "AMS A Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "1200330000030003",
"intro": "AMS A Slot4 RFID cannot be read because of a structural error."
},
{
"ecode": "1200730000010001",
"intro": "AMS A Filament speed and length error: The slot 4 filament odometry may be faulty."
},
{
"ecode": "1201310000010001",
"intro": "AMS B Slot 2 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202100000010001",
"intro": "The AMS C Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1202200000020003",
"intro": "AMS C Slot1 filament may be broken in the PTFE tube."
},
{
"ecode": "1202200000030001",
"intro": "AMS C Slot1 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1203210000020005",
"intro": "AMS D Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead."
},
{
"ecode": "0702100000020004",
"intro": "AMS C The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0700010000010005",
"intro": "AMS A The currentsensor of assist motor may be faulty."
},
{
"ecode": "0702900000020001",
"intro": "AMS C The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0701130000020004",
"intro": "AMS B The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault."
},
{
"ecode": "0500040000020014",
"intro": "The RFID-tag on AMS B Slot1 cannot be identified."
},
{
"ecode": "0700010000020002",
"intro": "The AMS A assist motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200120000010001",
"intro": "The AMS A Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1200310000010001",
"intro": "AMS A Slot 2 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1200320000030003",
"intro": "AMS A Slot3 RFID cannot be read because of a structural error."
},
{
"ecode": "1202220000020004",
"intro": "AMS C Slot3 filament may be broken in the tool head."
},
{
"ecode": "1202300000010001",
"intro": "AMS C Slot 1 RFID coil is broken or the RF hardware circuit has an error."
},
{
"ecode": "1202810000020001",
"intro": "AMS C Slot2 filament may be tangled or stuck."
},
{
"ecode": "0700900000010002",
"intro": "AMS A The coil of exhaust valve 1 is short-circuited, which may be due to abnormal wiring or damage."
},
{
"ecode": "0700910000020001",
"intro": "AMS A The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0700920000010001",
"intro": "AMS A The cooling fan of heater 1 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "050003000001000C",
"intro": "The MC motor controller module is malfunctioning. Please power off, check the connection, and restart the device."
},
{
"ecode": "0700900000020001",
"intro": "AMS A The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance."
},
{
"ecode": "0500040000020012",
"intro": "The RFID-tag on AMS A Slot3 cannot be identified."
},
{
"ecode": "0701010000010004",
"intro": "The AMS B assist motor speed control is malfunctioning. The speed sensor may be faulty."
},
{
"ecode": "1200100000010003",
"intro": "The AMS A Slot1 motor torque control is malfunctioning. The current sensor may be faulty."
},
{
"ecode": "1200110000020002",
"intro": "The AMS A Slot2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1200200000020004",
"intro": "AMS A Slot1 filament may be broken in the tool head."
},
{
"ecode": "1202820000020001",
"intro": "AMS C Slot3 filament may be tangled or stuck."
},
{
"ecode": "1203130000020002",
"intro": "The AMS D Slot4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1203220000030001",
"intro": "AMS D Slot3 filament has run out. Purging the old filament; please wait."
},
{
"ecode": "1203230000020006",
"intro": "Failed to extrude AMS D Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip."
},
{
"ecode": "0300260000010001",
"intro": "The frequency of the extrusion force sensor of the left extruder is too low. The sensor may be installed too far or the sensor may be loose."
},
{
"ecode": "0700930000010001",
"intro": "AMS A The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0700010000020011",
"intro": "AMS A The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS."
},
{
"ecode": "1200230000020001",
"intro": "AMS A Slot4 filament has run out; please insert a new filament."
},
{
"ecode": "1200300000020002",
"intro": "The RFID-tag on AMS A Slot 1 is damaged."
},
{
"ecode": "1200310000030003",
"intro": "AMS A Slot2 RFID cannot be read because of a structural error."
},
{
"ecode": "1200810000020001",
"intro": "AMS A Slot2 filament may be tangled or stuck."
},
{
"ecode": "1201100000010001",
"intro": "The AMS B Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin."
},
{
"ecode": "1201110000020002",
"intro": "The AMS B Slot2 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201130000020002",
"intro": "The AMS B Slot4 motor is overloaded. The filament may be tangled or stuck."
},
{
"ecode": "1201200000030002",
"intro": "AMS B Slot1 filament has run out and automatically switched to the slot with the same filament."
},
{
"ecode": "1201330000030003",
"intro": "AMS B Slot4 RFID cannot be read because of a structural error."
},
{
"ecode": "0702930000010001",
"intro": "AMS C The cooling fan of heater 2 is blocked, which may be due to the fan being stuck."
},
{
"ecode": "0702800000010004",
"intro": "AMS C The heater 1 heating abnormally."
},
{
"ecode": "12FF200000020001",
"intro": "Filament at the spool holder has run out; please insert a new filament."
},
{
"ecode": "12FF200000020002",
"intro": "Filament on the spool holder is empty; please insert a new filament."
},
{
"ecode": "12FF200000020005",
"intro": "Filament may be broken in the tool head."
},
{
"ecode": "12FF200000020007",
"intro": "Failed to check the filament location in the tool head; please click for more help."
},
{
"ecode": "12FF200000030007",
"intro": "Checking the filament location of all AMS slots, please wait."
},
{
"ecode": "12FF800000020001",
"intro": "The filament on the spool holder may be tangled or stuck."
},
{
"ecode": "1200450000020001",
"intro": "The filament cutter sensor is malfunctioning. Please check whether the connector is properly plugged in."
},
{
"ecode": "1200450000020002",
"intro": "The filament cutter's cutting distance is too large. The X motor may lose steps."
},
{
"ecode": "1200450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "1200510000030001",
"intro": "AMS is disabled; please load filament from spool holder."
},
{
"ecode": "0C0001000001000A",
"intro": "The Micro Lidar LED may be broken."
},
{
"ecode": "0C00020000020002",
"intro": "The horizontal laser line is too wide. Please check if the heatbed is dirty."
},
{
"ecode": "0C00020000020008",
"intro": "The vertical laser line is too wide. Please check if the heatbed is dirty."
},
{
"ecode": "0C00030000010009",
"intro": "The first layer inspection module rebooted abnormally. The inspection result may be inaccurate."
},
{
"ecode": "0C00030000020001",
"intro": "Filament exposure metering failed because laser reflection is too weak on this material. First layer inspection may be inaccurate."
},
{
"ecode": "0C00030000020002",
"intro": "First layer inspection terminated due to abnormal Lidar data."
},
{
"ecode": "0C00030000020004",
"intro": "First layer inspection is not supported for the current print job."
},
{
"ecode": "0C00030000020005",
"intro": "First layer inspection timed out abnormally, and the current results may be inaccurate."
},
{
"ecode": "0C00030000030006",
"intro": "Purged filament may have piled up in the waste chute. Please check and clean the chute."
},
{
"ecode": "0C00030000030007",
"intro": "Possible first layer defects have been detected. Please check the first layer quality and decide if the job should be stopped."
},
{
"ecode": "0C00030000030008",
"intro": "Possible spaghetti defects were detected. Please check the print quality and decide if the job should be stopped."
},
{
"ecode": "0C00030000030010",
"intro": "Your printer seems to be printing without extruding."
},
{
"ecode": "0703700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0703700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0703700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0703300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0703310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0703350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0702300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0702310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0702350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0702700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0702700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0702700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0701700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0701700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0701700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0701300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0701310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0701350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0700300000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0700310000030003",
"intro": "RFID cannot be read because of a hardware or structural error."
},
{
"ecode": "0700350000010001",
"intro": "The temperature and humidity sensor has an error. The chip may be faulty."
},
{
"ecode": "0700400000020001",
"intro": "The filament buffer position signal lost: the cable or position sensor may be malfunctioning."
},
{
"ecode": "0700400000020002",
"intro": "The filament buffer position signal error: the position sensor may be malfunctioning."
},
{
"ecode": "0700450000020001",
"intro": "The filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in."
},
{
"ecode": "0700450000020002",
"intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps."
},
{
"ecode": "0700450000020003",
"intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection."
},
{
"ecode": "0700510000030001",
"intro": "The AMS is disabled; please load filament from spool holder."
},
{
"ecode": "0700700000020001",
"intro": "Failed to pull out the filament from the extruder. Possible causes: clogged extruder or broken filament. Refer to the Assistant for details."
},
{
"ecode": "0700700000020007",
"intro": "AMS filament ran out. Please put a new filament into AMS and click the \"Retry\" button."
},
{
"ecode": "0700700000020008",
"intro": "Failed to get AMS mapping table; please click \"Resume\" to retry"
},
{
"ecode": "0500040000020020",
"intro": ""
},
{
"ecode": "0300930000010004",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air outlet may have an open circuit."
},
{
"ecode": "0300930000010007",
"intro": "Chamber temperature is abnormal. The temperature sensor at the power supply may have a short circuit."
},
{
"ecode": "0300930000010008",
"intro": "Chamber temperature is abnormal. The temperature sensor at power supply may have an open circuit."
},
{
"ecode": "0300940000020003",
"intro": "Chamber failed to reach the desired temperature. The machine will stop waiting for the chamber temperature."
},
{
"ecode": "0300940000030002",
"intro": "Chamber temperature setting value exceed the limit, the boundary value will be set."
},
{
"ecode": "0500020000020002",
"intro": "Device login failed; please check your account information."
},
{
"ecode": "0500020000020004",
"intro": "Unauthorized user: please check your account information."
},
{
"ecode": "0500020000020006",
"intro": "Streaming function error. Please check the network and try again. You can restart or update the printer if the issue persists."
},
{
"ecode": "0500020000020007",
"intro": "Liveview service login failed; please check your network connection."
},
{
"ecode": "0500020000020008",
"intro": "Time synchronization failed."
},
{
"ecode": "0500030000010001",
"intro": "The MC module is malfunctioning; please restart the device or check device cable connection."
},
{
"ecode": "0500030000010002",
"intro": "The toolhead is malfunctioning. Please restart the device."
},
{
"ecode": "0500030000010003",
"intro": "The AMS module is malfunctioning. Please restart the device."
},
{
"ecode": "0500030000010004",
"intro": "The AHB module is malfunctioning. Please restart the device."
},
{
"ecode": "0500030000010005",
"intro": "Internal service is malfunctioning. Please restart the device."
},
{
"ecode": "0500030000010006",
"intro": "A system panic occurred. Please restart the device."
},
{
"ecode": "0500030000010008",
"intro": "A system hang occurred. Please restart the device."
},
{
"ecode": "0500030000010009",
"intro": "A system hang occurred. It has been recovered by automatic restart."
},
{
"ecode": "0500030000010023",
"intro": "The Chamber Temperature Control module is malfunctioning. Please restart the device."
},
{
"ecode": "0500030000010025",
"intro": "The current firmware is abnormal. Please update again."
},
{
"ecode": "0500040000010004",
"intro": "The print file is unauthorized."
},
{
"ecode": "0500040000020007",
"intro": "The bed temperature exceeds the filament's vitrification temperature, which may cause a nozzle clog. Please keep the front door of the printer open or lower the bed temperature."
},
{
"ecode": "0300400000020001",
"intro": "Data transmission over the serial port is abnormal; the software system may be faulty."
},
{
"ecode": "0300900000010001",
"intro": "Chamber heating failed. The chamber heater may be failing to blow hot air."
},
{
"ecode": "0300900000010003",
"intro": "Chamber heating failed. The temperature of power supply may be too high."
},
{
"ecode": "0300900000010004",
"intro": "Chamber heating failed. The speed of the heating fan is too low."
},
{
"ecode": "0300900000010005",
"intro": "Chamber heating failed. The thermal resistance is too high."
},
{
"ecode": "0300900000010010",
"intro": "The communication of chamber temperature controller is abnormal."
},
{
"ecode": "0300910000010001",
"intro": "The temperature of chamber heater 1 is abnormal. The heater may have a short circuit."
},
{
"ecode": "0300910000010002",
"intro": "The temperature of chamber heater 1 is abnormal. The heater may have an open circuit or the thermal fuse may have taken effect."
},
{
"ecode": "0300910000010003",
"intro": "The temperature of chamber heater 1 is abnormal. The heater is over temperature."
},
{
"ecode": "0300910000010006",
"intro": "The temperature of chamber heater 1 is abnormal. The sensor may have a short circuit."
},
{
"ecode": "0300910000010007",
"intro": "The temperature of chamber heater 1 is abnormal. The sensor may have an open circuit."
},
{
"ecode": "0300910000010008",
"intro": "Chamber heater 1 failed to rise to target temperature."
},
{
"ecode": "030091000001000A",
"intro": "The temperature of chamber heater 1 is abnormal. The AC board may be broken."
},
{
"ecode": "0300920000010001",
"intro": "The temperature of chamber heater 2 is abnormal. The heater may have a short circuit."
},
{
"ecode": "0300920000010002",
"intro": "The temperature of chamber heater 2 is abnormal. The heater may have an open circuit or the thermal fuse may be in effect."
},
{
"ecode": "0300920000010003",
"intro": "The temperature of chamber heater 2 is abnormal. The heater is over temperature."
},
{
"ecode": "0300920000010006",
"intro": "The temperature of chamber heater 2 is abnormal. The sensor may have a short circuit."
},
{
"ecode": "0300920000010007",
"intro": "The temperature of chamber heater 2 is abnormal. The sensor may have an open circuit."
},
{
"ecode": "0300920000010008",
"intro": "Chamber heater 2 failed to rise to target temperature."
},
{
"ecode": "030092000001000A",
"intro": "The temperature of chamber heater 2 is abnormal. The AC board may be broken."
},
{
"ecode": "0300930000010001",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor may have a short circuit."
},
{
"ecode": "0300930000010002",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor may have an open circuit."
},
{
"ecode": "0300930000010003",
"intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air outlet may have a short circuit."
},
{
"ecode": "0300050000010001",
"intro": "The motor driver is overheating. Its radiator may be loose, or its cooling fan may be damaged."
},
{
"ecode": "0300060000010001",
"intro": "Motor-A has an open-circuit. There may be a loose connection, or the motor may have failed."
},
{
"ecode": "0300060000010002",
"intro": "Motor-A has a short-circuit. It may have failed."
},
{
"ecode": "0300070000010001",
"intro": "Motor-B has an open-circuit. The connection may be loose, or the motor may have failed."
},
{
"ecode": "0300070000010002",
"intro": "Motor-B has a short-circuit. It may have failed."
},
{
"ecode": "0300080000010001",
"intro": "Motor-Z has an open-circuit. The connection may be loose, or the motor may have failed."
},
{
"ecode": "0300080000010002",
"intro": "Motor-Z has a short-circuit. It may have failed."
},
{
"ecode": "0300090000010001",
"intro": "Motor-E has an open-circuit. The connection may be loose, or the motor may have failed."
},
{
"ecode": "0300090000010002",
"intro": "Motor-E has a short-circuit. It may have failed."
},
{
"ecode": "03000A0000010001",
"intro": "Heatbed force sensor 1 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight."
},
{
"ecode": "03000A0000010002",
"intro": "The signal of heatbed force sensor 1 is weak. The force sensor may be broken or have poor electric connection."
},
{
"ecode": "03000A0000010003",
"intro": "The signal of heatbed force sensor 1 is too weak. The electronic connection to the sensor may be broken."
},
{
"ecode": "03000A0000010004",
"intro": "An external disturbance was detected on force sensor 1. The heatbed plate may have touched something outside the heatbed."
},
{
"ecode": "03000A0000010005",
"intro": "Force sensor 1 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken."
},
{
"ecode": "03000B0000010001",
"intro": "Heatbed force sensor 2 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight."
},
{
"ecode": "03000B0000010002",
"intro": "The signal of heatbed force sensor 2 is weak. The force sensor may be broken or have poor electric connection."
},
{
"ecode": "03000B0000010003",
"intro": "The signal of heatbed force sensor 2 is too weak. The electronic connection to the sensor may be broken."
},
{
"ecode": "03000B0000010004",
"intro": "An external disturbance was detected on force sensor 2. The heatbed plate may have touched something outside the heatbed."
},
{
"ecode": "03000B0000010005",
"intro": "Force sensor 2 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken."
},
{
"ecode": "03000C0000010001",
"intro": "Heatbed force sensor 3 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight."
},
{
"ecode": "03000C0000010002",
"intro": "The signal of heatbed force sensor 3 is weak. The force sensor may be broken or have poor electric connection."
},
{
"ecode": "03000C0000010003",
"intro": "The signal of heatbed force sensor 3 is too weak. The electronic connection to the sensor may be broken."
},
{
"ecode": "03000C0000010004",
"intro": "An external disturbance was detected on force sensor 3. The heatbed plate may have touched something outside the heatbed."
},
{
"ecode": "03000C0000010005",
"intro": "Force sensor 3 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken."
},
{
"ecode": "03000F0000010001",
"intro": "Abnormal accelerometer data detected. Please try to restart the printer."
},
{
"ecode": "0300100000020001",
"intro": "The resonance frequency of the X axis is low. The timing belt may be loose."
},
{
"ecode": "0300110000020001",
"intro": "The resonance frequency of the Y axis is low. The timing belt may be loose."
},
{
"ecode": "0300130000010001",
"intro": "The current sensor of Motor-A is abnormal. This may be caused by a failure of the hardware sampling circuit."
},
{
"ecode": "0300140000010001",
"intro": "The current sensor of Motor-B is abnormal. This may be caused by a failure of the hardware sampling circuit."
},
{
"ecode": "0300150000010001",
"intro": "The current sensor of Motor-Z is abnormal. This may be caused by a failure of the hardware sampling circuit."
},
{
"ecode": "0300160000010001",
"intro": "The current sensor of Motor-E is abnormal. This may be caused by a failure of the hardware sampling circuit."
},
{
"ecode": "0300170000010001",
"intro": "The hotend cooling fan speed is too slow or stopped. It may be stuck or the connector may not be plugged in properly."
},
{
"ecode": "0300170000020002",
"intro": "The hotend cooling fan speed is slow. It may be stuck and need cleaning."
},
{
"ecode": "03001B0000010001",
"intro": "The signal of the heatbed acceleration sensor is weak. The sensor may have fallen off or been damaged."
},
{
"ecode": "03001B0000010003",
"intro": "The heatbed acceleration sensor detected unexpected continuous force. The sensor may be stuck, or the analog front end may be broken."
},
{
"ecode": "03001C0000010001",
"intro": "The extrusion motor driver is abnormal. The MOSFET may have a short circuit."
},
{
"ecode": "0300200000010003",
"intro": "X axis homing abnormal: the timing belt may be loose."
},
{
"ecode": "0300200000010004",
"intro": "Y axis homing abnormal: the timing belt may be loose."
},
{
"ecode": "0300010000010002",
"intro": "The heatbed temperature is abnormal; the heater may have an open circuit, or the thermal switch may be open."
},
{
"ecode": "0300010000010003",
"intro": "The heatbed temperature is abnormal; the heater is over temperature."
},
{
"ecode": "0300010000010006",
"intro": "The heatbed temperature is abnormal; the sensor may have a short circuit."
},
{
"ecode": "0300010000010007",
"intro": "The heatbed temperature is abnormal; the sensor may have an open circuit."
},
{
"ecode": "030001000001000C",
"intro": "The heatbed has worked at full load for a long time. The temperature control system may be abnormal."
},
{
"ecode": "0300010000030008",
"intro": "The temperature of the heated bed exceeds the limit and automatically adjusts to the limit temperature."
}
],
"ver": 202501031057
},