Closes review comment 6. The per-tool pressure advance work changed set_pressure_advance() for users who are not using the feature. RepRapFirmware lost its D qualifier when no tool index was supplied: upstream emits M572 D0 S<pa> unconditionally, and a bare M572 applies to whatever tool is currently selected and errors when there is none, so PA started depending on tool-selection state for every RRF user. The D is back, defaulting to 0, and D<tool> is reached only from the IMEX paths. The same rewrite had also changed the comment separator from "<value>; Override" to "<value> ; Override" on the Klipper, RRF, Marlin 2.x and Marlin Legacy branches, so every non-IMEX print of those flavors carried a one-byte diff. Restored. Upstream is internally inconsistent here -- BBL and Repetier do use the spaced form -- and the point is to match it exactly rather than to tidy it. Emitted output for all six flavors with no tool index is now byte-identical to upstream. Verified on a real slice: a Klipper profile emits "SET_PRESSURE_ADVANCE ADVANCE=0.02; Override pressure advance value", an exact string match, with no EXTRUDER= qualifier. The tests were pinning the regressed form and are inverted. Also records at the imex key registrations why they are kept out of the g-code config block, matching the house convention at the other banned keys. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
OrcaSlicer tests
Building, running and writing tests is documented on the wiki, under How to Test.
Two files here rather than there, because coding agents only read what is in the repository: