{ "result": 0, "t": 1761711923, "ver": 202511162200, "data": { "device_hms": { "ver": 202511162200, "en": [ { "ecode": "1805930000020003", "intro": "The AMS-HT F heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0704220000020025", "intro": "AMS E slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702930000020003", "intro": "The AMS C heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1802920000020003", "intro": "The AMS-HT C heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1806200000020025", "intro": "AMS-HT G slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702220000020025", "intro": "AMS C slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0707200000020025", "intro": "AMS H slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1803220000020025", "intro": "AMS-HT D slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1803930000020003", "intro": "The AMS-HT D heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0704230000020025", "intro": "AMS E slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1803920000020003", "intro": "The AMS-HT D heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1804220000020025", "intro": "AMS-HT E slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1800930000020003", "intro": "The AMS-HT A heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1805200000020025", "intro": "AMS-HT F slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702230000020025", "intro": "AMS C slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1806210000020025", "intro": "AMS-HT G slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1807200000020025", "intro": "AMS-HT H slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0705930000020003", "intro": "The AMS F heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1804200000020025", "intro": "AMS-HT E slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1804210000020025", "intro": "AMS-HT E slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0300A40000010005", "intro": "The heatbed temperature sensor is abnormal. Please troubleshoot the issue before restarting the task." }, { "ecode": "0701920000020003", "intro": "The AMS B heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0707210000020025", "intro": "AMS H slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0700920000020003", "intro": "The AMS A heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1802930000020003", "intro": "The AMS-HT C heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1801930000020003", "intro": "The AMS-HT B heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0703230000020025", "intro": "AMS D slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1803200000020025", "intro": "AMS-HT D slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0703210000020025", "intro": "AMS D slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0300A50000010004", "intro": "Flame Sensor 4 is abnormal. The sensor may be short-circuited." }, { "ecode": "0706930000020003", "intro": "The AMS G heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1801200000020025", "intro": "AMS-HT B slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0700230000020025", "intro": "AMS A slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1806230000020025", "intro": "AMS-HT G slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0703220000020025", "intro": "AMS D slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1807920000020003", "intro": "The AMS-HT H heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1805210000020025", "intro": "AMS-HT F slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0700200000020025", "intro": "AMS A slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1801220000020025", "intro": "AMS-HT B slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1802220000020025", "intro": "AMS-HT C slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0704210000020025", "intro": "AMS E slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0300A50000010002", "intro": "Flame Sensor 2 is abnormal. The sensor may be short-circuited." }, { "ecode": "1800210000020025", "intro": "AMS-HT A slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1804230000020025", "intro": "AMS-HT E slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1800920000020003", "intro": "The AMS-HT A heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0706920000020003", "intro": "The AMS G heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0702920000020003", "intro": "The AMS C heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1802210000020025", "intro": "AMS-HT C slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0706200000020025", "intro": "AMS G slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702200000020025", "intro": "AMS C slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1802230000020025", "intro": "AMS-HT C slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0705200000020025", "intro": "AMS F slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0C00030000020019", "intro": "The Vision Encoder Plate is either not placed or incorrectly placed. Please ensure it is correctly positioned on the heatbed." }, { "ecode": "1801920000020003", "intro": "The AMS-HT B heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1805220000020025", "intro": "AMS-HT F slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0704920000020003", "intro": "The AMS E heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1805920000020003", "intro": "The AMS-HT F heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0701200000020025", "intro": "AMS B slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1803230000020025", "intro": "AMS-HT D slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0300A50000010005", "intro": "Flame Sensor 5 is abnormal. The sensor may be short-circuited." }, { "ecode": "1804920000020003", "intro": "The AMS-HT E heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1806220000020025", "intro": "AMS-HT G slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0705220000020025", "intro": "AMS F slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0701220000020025", "intro": "AMS B slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0300A50000010001", "intro": "Flame Sensor 1 is abnormal. The sensor may be short-circuited." }, { "ecode": "1800220000020025", "intro": "AMS-HT A slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0706230000020025", "intro": "AMS G slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0701230000020025", "intro": "AMS B slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1802200000020025", "intro": "AMS-HT C slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0701210000020025", "intro": "AMS B slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0703930000020003", "intro": "The AMS D heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1804930000020003", "intro": "The AMS-HT E heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1807230000020025", "intro": "AMS-HT H slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0706210000020025", "intro": "AMS G slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0707930000020003", "intro": "The AMS H heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1807930000020003", "intro": "The AMS-HT H heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0703200000020025", "intro": "AMS D slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1801230000020025", "intro": "AMS-HT B slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1807210000020025", "intro": "AMS-HT H slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1801210000020025", "intro": "AMS-HT B slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0707220000020025", "intro": "AMS H slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0707230000020025", "intro": "AMS H slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0703920000020003", "intro": "The AMS D heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1800200000020025", "intro": "AMS-HT A slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0705210000020025", "intro": "AMS F slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0700930000020003", "intro": "The AMS A heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0300A50000010003", "intro": "Flame Sensor 3 is abnormal. The sensor may be short-circuited." }, { "ecode": "0705230000020025", "intro": "AMS F slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1806930000020003", "intro": "The AMS-HT G heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1800230000020025", "intro": "AMS-HT A slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1806920000020003", "intro": "The AMS-HT G heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0707920000020003", "intro": "The AMS H heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1803210000020025", "intro": "AMS-HT D slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702210000020025", "intro": "AMS C slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0704200000020025", "intro": "AMS E slot 1 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0705920000020003", "intro": "The AMS F heater 1 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0701930000020003", "intro": "The AMS B heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "1807220000020025", "intro": "AMS-HT H slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0706220000020025", "intro": "AMS G slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0700210000020025", "intro": "AMS A slot 2 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0704930000020003", "intro": "The AMS E heater 2 cooling fan cannot start because the power adapter is not connected." }, { "ecode": "0700220000020025", "intro": "AMS A slot 3 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "1805230000020025", "intro": "AMS-HT F slot 4 feed resistance is too high. Please reduce the feed resistance, decrease the rotation resistance of the spool, and avoid having the filament tube too long and excessively bent." }, { "ecode": "0702210000010083", "intro": "Failed to read the filament information from AMS C slot 2. The RFID tag may be damaged." }, { "ecode": "0704220000020022", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0300940000020003", "intro": "Chamber failed to reach the desired temperature. The machine will stop waiting for the chamber temperature." }, { "ecode": "1802020000010001", "intro": "AMS-HT C Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1800320000020002", "intro": "The RFID-tag on AMS-HT A Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1800100000020002", "intro": "The AMS-HT A slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800110000020002", "intro": "The AMS-HT A slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0702110000020004", "intro": "AMS C The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0700900000010002", "intro": "AMS A The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0703200000020010", "intro": "AMS D slot 1 feeds filament out of AMS timeout." }, { "ecode": "1803220000010085", "intro": "Failed to read the filament information from AMS-HT D slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "180520000002000A", "intro": "Failed to adjust the filament position of AMS-HT F Slot 1. The filament or buffer may be stuck." }, { "ecode": "1201310000030003", "intro": "AMS B Slot2 RFID cannot be read because of a structural error." }, { "ecode": "0707230000020023", "intro": "AMS H slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0C00020000020002", "intro": "The horizontal laser line is too wide. Please check if the heatbed is dirty." }, { "ecode": "1805230000010085", "intro": "Failed to read the filament information from AMS-HT F slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0581050000010010", "intro": "The firmware of AMS-HT B does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0701220000020007", "intro": "AMS B Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1807210000020010", "intro": "AMS-HT H slot 2 feeds filament out of AMS timeout." }, { "ecode": "1805960000010003", "intro": "AMS-HT F Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0702210000030002", "intro": "AMS C Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0500030000020020", "intro": "USB flash drive capacity is insufficient to cache print files." }, { "ecode": "0702230000020007", "intro": "AMS C Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705220000020013", "intro": "AMS F slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "03000A0000010004", "intro": "An external disturbance was detected on force sensor 1. The heatbed plate may have touched something outside the heatbed." }, { "ecode": "1203220000020003", "intro": "AMS D Slot3 filament may be broken in the PTFE tube." }, { "ecode": "0300200000010004", "intro": "Y axis homing abnormal: the timing belt may be loose." }, { "ecode": "0704220000020016", "intro": "AMS E slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807130000020002", "intro": "The AMS-HT H slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1802200000020023", "intro": "AMS-HT C slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0300930000010003", "intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air outlet may have a short circuit." }, { "ecode": "1803220000020010", "intro": "AMS-HT D slot 3 feeds filament out of AMS timeout." }, { "ecode": "1804200000020009", "intro": "Failed to extrude AMS-HT E Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0704300000010001", "intro": "The AMS E RFID 1 board has an error." }, { "ecode": "0705220000010081", "intro": "Failed to read the filament information from AMS F slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0300090000020002", "intro": "The extrusion resistance is abnormal. The extruder may be clogged or there may be filament stuck in the toolhead." }, { "ecode": "0700230000010082", "intro": "Failed to read the filament information from AMS A slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1800010000010003", "intro": "The AMS-HT A assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706010000020002", "intro": "The AMS G assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1203210000030002", "intro": "AMS D Slot2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700920000010001", "intro": "AMS A The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "0703210000020023", "intro": "AMS D slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0703730000020004", "intro": "Failed to pull back the AMS D Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805200000020018", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0702230000010086", "intro": "Failed to read the filament information from AMS C slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703200000020001", "intro": "AMS D Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0704100000010003", "intro": "The AMS E slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0702210000010084", "intro": "Failed to read the filament information from AMS C slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "03001B0000010002", "intro": "External disturbance was detected on the heatbed acceleeration sensor. The sensor signal wire may not be affixed." }, { "ecode": "1805910000020001", "intro": "AMS-HT F The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0705330000020002", "intro": "The RFID-tag on AMS F Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0704220000030002", "intro": "AMS E Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0701230000020012", "intro": "AMS B slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1807200000020006", "intro": "AMS-HT H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1801210000020011", "intro": "AMS-HT B slot 2 pulls filament back to AMS timeout." }, { "ecode": "0704220000010084", "intro": "Failed to read the filament information from AMS E slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0704230000020002", "intro": "AMS E Slot 4 is empty; please insert a new filament." }, { "ecode": "0701200000020002", "intro": "AMS B Slot 1 is empty; please insert a new filament." }, { "ecode": "1203220000030001", "intro": "AMS D Slot3 filament has run out. Purging the old filament; please wait." }, { "ecode": "1801230000020012", "intro": "AMS-HT B slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1806230000020023", "intro": "AMS-HT G slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1805310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1801900000020001", "intro": "AMS-HT B The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "0706120000010001", "intro": "The AMS G slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1801220000010085", "intro": "Failed to read the filament information from AMS-HT B slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1802230000020019", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706210000020014", "intro": "AMS G slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1801220000010086", "intro": "Failed to read the filament information from AMS-HT B slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1803910000010002", "intro": "AMS-HT D The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "03000B0000010002", "intro": "The signal of heatbed force sensor 2 is weak. The force sensor may be broken or have poor electric connection." }, { "ecode": "0703210000020013", "intro": "AMS D slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0300C10000010001", "intro": "Airflow System failed to activate cooling mode; please check the air door status." }, { "ecode": "0702230000020023", "intro": "AMS C slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0703800000010004", "intro": "AMS D The heater 1 is heating abnormally." }, { "ecode": "1806200000020007", "intro": "AMS-HT G Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1804200000020003", "intro": "AMS-HT E Slot 1's filament may be broken in AMS-HT." }, { "ecode": "0706210000020018", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0704230000010083", "intro": "Failed to read the filament information from AMS E slot 4. The RFID tag may be damaged." }, { "ecode": "1807730000020004", "intro": "Failed to pull back the AMS-HT H Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704810000010001", "intro": "AMS E The current sensor of heater 2 is abnormal." }, { "ecode": "0707230000020020", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1801210000020004", "intro": "AMS-HT B Slot 2 filament may be broken in the tool head." }, { "ecode": "1804010000010005", "intro": "AMS-HT E The current sensor of assist motor may be faulty." }, { "ecode": "0707230000020002", "intro": "AMS H Slot 4 is empty; please insert a new filament." }, { "ecode": "0701220000020003", "intro": "AMS B Slot 3's filament may be broken in AMS." }, { "ecode": "1805200000020009", "intro": "Failed to extrude AMS-HT F Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707210000020014", "intro": "AMS H slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704700000020001", "intro": "Failed to pull out the AMS E Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0500060000020001", "intro": "The Toolhead Camera is not in place; please check the hardware connection." }, { "ecode": "1801200000010081", "intro": "Failed to read the filament information from AMS-HT B slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1806200000020013", "intro": "AMS-HT G slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707210000020023", "intro": "AMS H slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1802010000010011", "intro": "AMS-HT C The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1806100000010003", "intro": "The AMS-HT G slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0702710000020002", "intro": "Failed to feed the AMS C Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0300980000010003", "intro": "The left side window Hall sensor (Lower) is abnormal; please check whether the connection wire is loose." }, { "ecode": "1805920000020002", "intro": "AMS-HT F The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "1801720000020001", "intro": "Failed to pull out the AMS-HT B Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0707220000020011", "intro": "AMS H slot 3 pulls filament back to AMS timeout." }, { "ecode": "1805200000020008", "intro": "AMS-HT F Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700230000020014", "intro": "AMS A slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1806210000020002", "intro": "AMS-HT G Slot 2 is empty; please insert a new filament." }, { "ecode": "0703940000010001", "intro": "AMS D The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0703300000010004", "intro": "Encryption chip failure" }, { "ecode": "1805100000010003", "intro": "The AMS-HT F slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1803320000020002", "intro": "The RFID-tag on AMS-HT D Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1801110000020002", "intro": "The AMS-HT B slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704200000020014", "intro": "AMS E slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0702200000020024", "intro": "AMS C slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807310000010001", "intro": "The AMS-HT H RFID 2 board has an error." }, { "ecode": "0300970000030001", "intro": "The top cover is open." }, { "ecode": "0700010000010001", "intro": "The AMS A assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0703230000010085", "intro": "Failed to read the filament information from AMS D slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1200500000020001", "intro": "AMS A communication is abnormal; please check the connection cable." }, { "ecode": "1803710000020005", "intro": "Failed to feed the AMS-HT D Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1806200000020023", "intro": "AMS-HT G slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1800220000010082", "intro": "Failed to read the filament information from AMS-HT A slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0704210000020015", "intro": "AMS E slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1806220000020024", "intro": "AMS-HT G slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0705020000010001", "intro": "AMS F Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0701230000020015", "intro": "AMS B slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700310000020002", "intro": "The RFID-tag on AMS A Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0500030000020012", "intro": "" }, { "ecode": "1800200000020015", "intro": "AMS-HT A slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0C00020000020008", "intro": "The vertical laser line is too wide. Please check if the heatbed is dirty." }, { "ecode": "0707230000010082", "intro": "Failed to read the filament information from AMS H slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0701710000020002", "intro": "Failed to feed the AMS B Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702230000030001", "intro": "AMS C Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0704210000020008", "intro": "AMS E Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "050003000001000A", "intro": "System state is abnormal; please restore to factory settings." }, { "ecode": "1802200000020019", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "180022000002000A", "intro": "Failed to adjust the filament position of AMS-HT A Slot 3. The filament or buffer may be stuck." }, { "ecode": "1806220000020015", "intro": "AMS-HT G slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0703210000020005", "intro": "AMS D Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1801230000020024", "intro": "AMS-HT B slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "070422000002000A", "intro": "Failed to adjust the filament position of AMS E Slot 3. The filament or buffer may be stuck." }, { "ecode": "1807230000020021", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1807210000020001", "intro": "AMS-HT H Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1803110000010003", "intro": "The AMS-HT D slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804210000020024", "intro": "AMS-HT E slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0703220000020012", "intro": "AMS D slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1203200000020006", "intro": "Failed to extrude AMS D Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0702220000010086", "intro": "Failed to read the filament information from AMS C slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1200320000020002", "intro": "The RFID-tag on AMS A Slot 3 is damaged." }, { "ecode": "0C00040000010014", "intro": "Cutting Protection Base not detected, which\nmay lead to heatbed damage. Please place it and continue." }, { "ecode": "0704130000020004", "intro": "AMS E The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800220000020013", "intro": "AMS-HT A slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1805210000020008", "intro": "AMS-HT F Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0500040000010001", "intro": "Failed to download print job; please check your network connection." }, { "ecode": "1801200000020019", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0702200000030002", "intro": "AMS C Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1807130000010001", "intro": "The AMS-HT H slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0701200000020013", "intro": "AMS B slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701960000010003", "intro": "AMS B Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1801010000020006", "intro": "AMS-HT B The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1803300000020002", "intro": "The RFID-tag on AMS-HT D Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1806230000030002", "intro": "AMS-HT G Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1805200000020023", "intro": "AMS-HT F slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1804720000020004", "intro": "Failed to pull back the AMS-HT E Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704120000010001", "intro": "The AMS E slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707910000010003", "intro": "AMS H The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "0C0001000001000F", "intro": "The Live View Camera calibration failed. Please restart the devices or update the firmware." }, { "ecode": "1806220000020020", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0702220000020009", "intro": "Failed to extrude AMS C Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "030025000001000B", "intro": "Nozzle presence detection failed: Right extruder nozzle not installed or improperly installed." }, { "ecode": "1806220000020010", "intro": "AMS-HT G slot 3 feeds filament out of AMS timeout." }, { "ecode": "0700730000020004", "intro": "Failed to pull back the AMS A Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "18FF810000020001", "intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead." }, { "ecode": "18FE450000020003", "intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection." }, { "ecode": "1800230000020016", "intro": "AMS-HT A slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1804010000010004", "intro": "The AMS-HT E assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "0500010000020008", "intro": "" }, { "ecode": "1806130000010003", "intro": "The AMS-HT G slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1803220000030002", "intro": "AMS-HT D Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "180322000002000A", "intro": "Failed to adjust the filament position of AMS-HT D Slot 3. The filament or buffer may be stuck." }, { "ecode": "180522000002000A", "intro": "Failed to adjust the filament position of AMS-HT F Slot 3. The filament or buffer may be stuck." }, { "ecode": "0703200000020018", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0707230000010085", "intro": "Failed to read the filament information from AMS H slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1801010000010011", "intro": "AMS-HT B The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1801960000010003", "intro": "AMS-HT B Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1805700000020004", "intro": "Failed to pull back the AMS-HT F Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1802200000020021", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801230000020008", "intro": "AMS-HT B Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704210000030001", "intro": "AMS E Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0706960000020002", "intro": "AMS G Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1805220000020022", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0704320000020002", "intro": "The RFID-tag on AMS E Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0701200000020015", "intro": "AMS B slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1801950000010001", "intro": "AMS-HT B The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1801610000020001", "intro": "The AMS-HT B Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1200330000030003", "intro": "AMS A Slot4 RFID cannot be read because of a structural error." }, { "ecode": "1806700000020004", "intro": "Failed to pull back the AMS-HT G Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0500050000030002", "intro": "The device is in the engineering state; please pay attention to information security related matters." }, { "ecode": "0704200000020016", "intro": "AMS E slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1803220000010086", "intro": "Failed to read the filament information from AMS-HT D slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703130000010001", "intro": "The AMS D slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0704210000020014", "intro": "AMS E slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0701200000010081", "intro": "Failed to read the filament information from AMS B slot 1. The AMS main board may be malfunctioning." }, { "ecode": "0701210000020003", "intro": "AMS B Slot 2's filament may be broken in AMS." }, { "ecode": "180122000002000A", "intro": "Failed to adjust the filament position of AMS-HT B Slot 3. The filament or buffer may be stuck." }, { "ecode": "1806730000020005", "intro": "Failed to feed the AMS-HT G Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0704230000020022", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0705220000020004", "intro": "AMS F Slot 3 filament may be broken in the tool head." }, { "ecode": "1805220000010082", "intro": "Failed to read the filament information from AMS-HT F slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1804210000020018", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703200000020017", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1801210000030002", "intro": "AMS-HT B Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1807730000020002", "intro": "Failed to feed the AMS-HT H Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805230000030001", "intro": "AMS-HT F Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0300930000010007", "intro": "Chamber temperature is abnormal. The temperature sensor at the power supply may have a short circuit." }, { "ecode": "0704210000010081", "intro": "Failed to read the filament information from AMS E slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0702230000020014", "intro": "AMS C slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1805200000020021", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1805700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0707200000010085", "intro": "Failed to read the filament information from AMS H slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1200220000030001", "intro": "AMS A Slot3 filament has run out. Purging the old filament; please wait." }, { "ecode": "1803100000020002", "intro": "The AMS-HT D slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0701230000020022", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0700210000030002", "intro": "AMS A Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0707710000020001", "intro": "Failed to pull out the AMS H Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1202200000020006", "intro": "Failed to extrude AMS C Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0500020000020005", "intro": "Failed to connect to the internet; please check the network connection." }, { "ecode": "1806220000020004", "intro": "AMS-HT G Slot 3 filament may be broken in the tool head." }, { "ecode": "0704010000010003", "intro": "The AMS E assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0300270000010001", "intro": "The nozzle offset calibration sensor frequency is too low. The sensor may be damaged." }, { "ecode": "1203110000020002", "intro": "The AMS D Slot2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1804810000010001", "intro": "AMS-HT E The current sensor of heater 2 is abnormal." }, { "ecode": "0706210000010081", "intro": "Failed to read the filament information from AMS G slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0703110000010001", "intro": "The AMS D slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1807110000010003", "intro": "The AMS-HT H slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700200000020022", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1807210000020014", "intro": "AMS-HT H slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704220000020007", "intro": "AMS E Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0300A20000010001", "intro": "MC module temperature is too high, possibly because of high chamber temperature of the printer. You can try lowering the environmental temperature before use." }, { "ecode": "0705210000020002", "intro": "AMS F Slot 2 is empty; please insert a new filament." }, { "ecode": "0702230000020005", "intro": "AMS C Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1802230000020022", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1202320000010001", "intro": "AMS C Slot 3 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0700130000010001", "intro": "The AMS A slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1804210000020023", "intro": "AMS-HT E slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1805220000010081", "intro": "Failed to read the filament information from AMS-HT F slot 3. The AMS main board may be malfunctioning." }, { "ecode": "18FE800000020002", "intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model." }, { "ecode": "1801100000020002", "intro": "The AMS-HT B slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0702210000020015", "intro": "AMS C slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1202120000010003", "intro": "The AMS C Slot3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1803230000030002", "intro": "AMS-HT D Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0C00020000010005", "intro": "A new Micro Lidar was detected. Please calibrate it on the Calibration page before use." }, { "ecode": "1805210000020012", "intro": "AMS-HT F slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704310000020002", "intro": "The RFID-tag on AMS E Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0703200000020020", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1806210000030001", "intro": "AMS-HT G Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1804210000020001", "intro": "AMS-HT E Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1807010000020011", "intro": "AMS-HT H The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1803700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1802230000020012", "intro": "AMS-HT C slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1806240000020009", "intro": "AMS-HT G front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "1803230000010082", "intro": "Failed to read the filament information from AMS-HT D slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0300910000010001", "intro": "The temperature of chamber heater 1 is abnormal. The heater may have a short circuit." }, { "ecode": "18FE200000020004", "intro": "Please pull the external filament from the left extruder." }, { "ecode": "0706210000030002", "intro": "AMS G Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0701230000020004", "intro": "AMS B Slot 4 filament may be broken in the tool head." }, { "ecode": "1804210000020014", "intro": "AMS-HT E slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "03009D0000020002", "intro": "The engrave laser focal point XY calibration result differs significantly from the design values. Please re-install the Laser Module and re-run the Laser Module Setup." }, { "ecode": "1801220000020017", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0702010000020008", "intro": "AMS C The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "0300070000010002", "intro": "Motor-B has a short-circuit. It may have failed." }, { "ecode": "1800230000020017", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1802220000020009", "intro": "Failed to extrude AMS-HT C Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0705250000020001", "intro": "AMS F uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0703200000010085", "intro": "Failed to read the filament information from AMS D slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0707210000020002", "intro": "AMS H Slot 2 is empty; please insert a new filament." }, { "ecode": "1807220000020005", "intro": "AMS-HT H Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1203230000030002", "intro": "AMS D Slot4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0705210000020010", "intro": "AMS F slot 2 feeds filament out of AMS timeout." }, { "ecode": "1803210000020010", "intro": "AMS-HT D slot 2 feeds filament out of AMS timeout." }, { "ecode": "1800210000010082", "intro": "Failed to read the filament information from AMS-HT A slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805230000010086", "intro": "Failed to read the filament information from AMS-HT F slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1806230000030001", "intro": "AMS-HT G Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1806910000010003", "intro": "AMS-HT G The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1802130000020002", "intro": "The AMS-HT C slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807230000010085", "intro": "Failed to read the filament information from AMS-HT H slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0705230000020019", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700200000020014", "intro": "AMS A slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1801730000020004", "intro": "Failed to pull back the AMS-HT B Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700230000010084", "intro": "Failed to read the filament information from AMS A slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706230000020023", "intro": "AMS G slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1801210000010086", "intro": "Failed to read the filament information from AMS-HT B slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1802220000010081", "intro": "Failed to read the filament information from AMS-HT C slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0706230000020002", "intro": "AMS G Slot 4 is empty; please insert a new filament." }, { "ecode": "1807130000010003", "intro": "The AMS-HT H slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804710000020002", "intro": "Failed to feed the AMS-HT E Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700200000020012", "intro": "AMS A slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1801220000020004", "intro": "AMS-HT B Slot 3 filament may be broken in the tool head." }, { "ecode": "0300950000010005", "intro": "The Laser Module communication is abnormal; please check the connector." }, { "ecode": "0700200000020023", "intro": "AMS A slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807310000010004", "intro": "Encryption chip failure" }, { "ecode": "1200310000010001", "intro": "AMS A Slot 2 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1804200000020001", "intro": "AMS-HT E Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1805800000010001", "intro": "AMS-HT F The current sensor of heater 1 is abnormal." }, { "ecode": "1802210000020011", "intro": "AMS-HT C slot 2 pulls filament back to AMS timeout." }, { "ecode": "1804010000020011", "intro": "AMS-HT E The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0703200000010083", "intro": "Failed to read the filament information from AMS D slot 1. The RFID tag may be damaged." }, { "ecode": "0704220000020023", "intro": "AMS E slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0704230000020012", "intro": "AMS E slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1807200000020014", "intro": "AMS-HT H slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1803220000020017", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0500040000020011", "intro": "The RFID-tag on AMS A Slot2 cannot be identified." }, { "ecode": "1804930000010001", "intro": "AMS-HT E The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0300180000030009", "intro": "Performing initial High-temperature Bed Leveling." }, { "ecode": "0705200000020018", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1807010000020006", "intro": "AMS-HT H The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1801210000020005", "intro": "AMS-HT B Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1801110000010001", "intro": "The AMS-HT B slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0706210000020016", "intro": "AMS G slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1203130000010003", "intro": "The AMS D Slot4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "07FF800000010004", "intro": "The Toolhead Lifting Motor position hall sensor is short-circuited; please check if the Hall sensor is malfunctioning." }, { "ecode": "0705010000020009", "intro": "AMS F The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "1800230000020001", "intro": "AMS-HT A Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0707300000010001", "intro": "The AMS H RFID 1 board has an error." }, { "ecode": "1200220000020005", "intro": "AMS A Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "1807210000020012", "intro": "AMS-HT H slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0700200000020018", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0300030000020002", "intro": "The hotend cooling fan is running slowly. It may be obstructed. Please check for debris and clean if necessary." }, { "ecode": "1805200000020011", "intro": "AMS-HT F slot 1 pulls filament back to AMS timeout." }, { "ecode": "0706220000020003", "intro": "AMS G Slot 3's filament may be broken in AMS." }, { "ecode": "0703200000020022", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1800200000020009", "intro": "Failed to extrude AMS-HT A Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707720000020001", "intro": "Failed to pull out the AMS H Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802710000020004", "intro": "Failed to pull back the AMS-HT C Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805010000020002", "intro": "The AMS-HT F assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803230000020019", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1803210000010084", "intro": "Failed to read the filament information from AMS-HT D slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0705200000020023", "intro": "AMS F slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "07FE800000020001", "intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead." }, { "ecode": "0701200000020003", "intro": "AMS B Slot 1's filament may be broken in AMS." }, { "ecode": "1804220000020015", "intro": "AMS-HT E slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0703230000020010", "intro": "AMS D slot 4 feeds filament out of AMS timeout." }, { "ecode": "0706200000020020", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1800230000010081", "intro": "Failed to read the filament information from AMS-HT A slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1805110000010003", "intro": "The AMS-HT F slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0500030000010004", "intro": "The Filament Buffer module is malfunctioning. Please restart the device." }, { "ecode": "0703720000020004", "intro": "Failed to pull back the AMS D Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703110000020004", "intro": "AMS D The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803210000020015", "intro": "AMS-HT D slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0701220000020016", "intro": "AMS B slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0500060000020002", "intro": "The Nozzle Camera is not in place; please check the hardware connection." }, { "ecode": "0705300000010004", "intro": "Encryption chip failure" }, { "ecode": "0700210000020014", "intro": "AMS A slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1803200000010082", "intro": "Failed to read the filament information from AMS-HT D slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0300950000010006", "intro": "Laser Module not detected: the module may have fallen off, or the quick-release lever may not be locked." }, { "ecode": "0706200000020007", "intro": "AMS G Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1807200000020005", "intro": "AMS-HT H Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1805130000020004", "intro": "AMS-HT F The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701120000010003", "intro": "The AMS B slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1802010000010003", "intro": "The AMS-HT C assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0504050000010010", "intro": "The firmware of AMS E does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0702720000020005", "intro": "Failed to feed the AMS C Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0C00010000010010", "intro": "The Live View Camera calibration failed. Please check if the heatbed is clear and ensure the camera image is clear and dirt-free. After these steps, please recalibrate." }, { "ecode": "0704220000010083", "intro": "Failed to read the filament information from AMS E slot 3. The RFID tag may be damaged." }, { "ecode": "0703230000020004", "intro": "AMS D Slot 4 filament may be broken in the tool head." }, { "ecode": "1801930000020002", "intro": "AMS-HT B The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "180421000002000A", "intro": "Failed to adjust the filament position of AMS-HT E Slot 2. The filament or buffer may be stuck." }, { "ecode": "1801550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "1806810000010003", "intro": "AMS-HT G The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0703720000020001", "intro": "Failed to pull out the AMS D Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0705200000020024", "intro": "AMS F slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802210000010081", "intro": "Failed to read the filament information from AMS-HT C slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0703700000020001", "intro": "Failed to pull out the AMS D Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1806210000020022", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0300060000010001", "intro": "Motor-A has an open-circuit. There may be a loose connection, or the motor may have failed." }, { "ecode": "1801220000020005", "intro": "AMS-HT B Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1807710000020005", "intro": "Failed to feed the AMS-HT H Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0300400000020001", "intro": "Data transmission over the serial port is abnormal; the software system may be faulty." }, { "ecode": "1805210000010082", "intro": "Failed to read the filament information from AMS-HT F slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805120000010001", "intro": "The AMS-HT F slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0706020000020002", "intro": "AMS G The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1202300000020002", "intro": "The RFID-tag on AMS C Slot 1 is damaged." }, { "ecode": "1804300000010001", "intro": "The AMS-HT E RFID 1 board has an error." }, { "ecode": "0701220000020012", "intro": "AMS B slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704220000020009", "intro": "Failed to extrude AMS E Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0703230000010083", "intro": "Failed to read the filament information from AMS D slot 4. The RFID tag may be damaged." }, { "ecode": "1805230000020003", "intro": "AMS-HT F Slot 4's filament may be broken in AMS-HT." }, { "ecode": "0704300000010004", "intro": "Encryption chip failure" }, { "ecode": "07FF200000020004", "intro": "Please pull the external filament from the right extruder." }, { "ecode": "0705230000020017", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0706960000010003", "intro": "AMS G Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0701320000020002", "intro": "The RFID-tag on AMS B Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0704220000010086", "intro": "Failed to read the filament information from AMS E slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1802110000010003", "intro": "The AMS-HT C slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706210000020001", "intro": "AMS G Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1806220000020009", "intro": "Failed to extrude AMS-HT G Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807210000010086", "intro": "Failed to read the filament information from AMS-HT H slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0705800000010003", "intro": "AMS F The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1804200000030001", "intro": "AMS-HT E Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0701210000020010", "intro": "AMS B slot 2 feeds filament out of AMS timeout." }, { "ecode": "0707200000020011", "intro": "AMS H slot 1 pulls filament back to AMS timeout." }, { "ecode": "1201230000020004", "intro": "AMS B Slot4 filament may be broken in the tool head." }, { "ecode": "1806010000020009", "intro": "AMS-HT G The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0707550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0700200000010083", "intro": "Failed to read the filament information from AMS A slot 1. The RFID tag may be damaged." }, { "ecode": "0706220000020005", "intro": "AMS G Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0300930000010001", "intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor may have a short circuit." }, { "ecode": "1202230000020001", "intro": "AMS C Slot4 filament has run out; please insert a new filament." }, { "ecode": "0500020000020007", "intro": "Liveview service login failed; please check your network connection." }, { "ecode": "1804550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0706230000020012", "intro": "AMS G slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0702210000020018", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1801200000010085", "intro": "Failed to read the filament information from AMS-HT B slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0703230000020021", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1203330000020002", "intro": "The RFID-tag on AMS D Slot 4 is damaged." }, { "ecode": "1202730000010001", "intro": "AMS C Filament speed and length error: The slot 4 filament odometry may be faulty." }, { "ecode": "1807120000020004", "intro": "AMS-HT H The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0C00020000020007", "intro": "The vertical laser is not lit. Please check if it's covered or hardware connection has a problem." }, { "ecode": "1802230000020001", "intro": "AMS-HT C Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0707200000010086", "intro": "Failed to read the filament information from AMS H slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1805200000020020", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1805320000020002", "intro": "The RFID-tag on AMS-HT F Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0706900000010002", "intro": "AMS G The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1801220000020018", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0707200000010082", "intro": "Failed to read the filament information from AMS H slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1804200000030002", "intro": "AMS-HT E Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0300020000010007", "intro": "The right nozzle temperature is abnormal; the sensor may have an open circuit." }, { "ecode": "0700400000020004", "intro": "The filament buffer signal is abnormal; the spring may be stuck, or the filament may be tangled." }, { "ecode": "1203120000020002", "intro": "The AMS D Slot3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805220000020008", "intro": "AMS-HT F Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0C00040000010020", "intro": "The visual marker on the heatbed is damaged, please contact after-sales." }, { "ecode": "0707010000020011", "intro": "AMS H The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0703120000010001", "intro": "The AMS D slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1200200000020006", "intro": "Failed to extrude AMS A Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "070022000002000A", "intro": "Failed to adjust the filament position of AMS A Slot 3. The filament or buffer may be stuck." }, { "ecode": "1800200000020021", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802230000030002", "intro": "AMS-HT C Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1807230000020001", "intro": "AMS-HT H Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1801720000020002", "intro": "Failed to feed the AMS-HT B Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700220000020024", "intro": "AMS A slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1202210000020004", "intro": "AMS C Slot2 filament may be broken in the tool head." }, { "ecode": "0704700000020005", "intro": "Failed to feed the AMS E Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0300930000010005", "intro": "Chamber temperature is abnormal. The chamber temperature sensor may have a short circuit." }, { "ecode": "1803210000020008", "intro": "AMS-HT D Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1805220000020011", "intro": "AMS-HT F slot 3 pulls filament back to AMS timeout." }, { "ecode": "1805630000020001", "intro": "The AMS-HT F Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702220000020007", "intro": "AMS C Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0500060000020005", "intro": "" }, { "ecode": "180722000002000A", "intro": "Failed to adjust the filament position of AMS-HT H Slot 3. The filament or buffer may be stuck." }, { "ecode": "0705100000020002", "intro": "The AMS F slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "03000B0000010003", "intro": "The signal of heatbed force sensor 2 is too weak. The electronic connection to the sensor may be broken." }, { "ecode": "180720000002000A", "intro": "Failed to adjust the filament position of AMS-HT H Slot 1. The filament or buffer may be stuck." }, { "ecode": "0707210000020004", "intro": "AMS H Slot 2 filament may be broken in the tool head." }, { "ecode": "0705610000020001", "intro": "The AMS F Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800700000020001", "intro": "Failed to pull out the AMS-HT A Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701970000030001", "intro": "AMS B chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0300960000010001", "intro": "The front door seems to be open; the task has been paused." }, { "ecode": "0702200000020012", "intro": "AMS C slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0700200000010086", "intro": "Failed to read the filament information from AMS A slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1200230000020005", "intro": "AMS A Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0705900000010003", "intro": "AMS F The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "1807200000010081", "intro": "Failed to read the filament information from AMS-HT H slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1801230000010085", "intro": "Failed to read the filament information from AMS-HT B slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0500060000020023", "intro": "" }, { "ecode": "1800210000010084", "intro": "Failed to read the filament information from AMS-HT A slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0702230000030002", "intro": "AMS C Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1800940000010001", "intro": "AMS-HT A The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1801220000020001", "intro": "AMS-HT B Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1807700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0C00010000010011", "intro": "The Live View Camera calibration failed, please recalibrate. Ensure the build plate is empty, and the camera view is clear and properly oriented. Please contact customer support if repeated failures occur." }, { "ecode": "1806500000020001", "intro": "AMS-HT G communication is abnormal; please check the connection cable." }, { "ecode": "1807300000010004", "intro": "Encryption chip failure" }, { "ecode": "1803210000020022", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0702330000020002", "intro": "The RFID-tag on AMS C Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0703200000020011", "intro": "AMS D slot 1 pulls filament back to AMS timeout." }, { "ecode": "1202230000020002", "intro": "AMS C Slot 4 is empty; please insert a new filament." }, { "ecode": "0500030000020011", "intro": "" }, { "ecode": "1200210000020004", "intro": "AMS A Slot2 filament may be broken in the tool head." }, { "ecode": "1800230000020022", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0706020000010001", "intro": "AMS G Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1807300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1803710000020001", "intro": "Failed to pull out the AMS-HT D Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802230000020020", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0700200000020008", "intro": "AMS A Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1807230000020023", "intro": "AMS-HT H slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1805810000010003", "intro": "AMS-HT F The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0500050000010007", "intro": "MQTT Command verification failed. Please update Studio (including the network plugin) or Handy to the latest version, then restart the software and try again." }, { "ecode": "0706220000020012", "intro": "AMS G slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0706960000010001", "intro": "AMS G The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0701220000020019", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0701560000030001", "intro": "AMS B is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "1803810000010002", "intro": "AMS-HT D The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1802110000020002", "intro": "The AMS-HT C slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707210000020020", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1801730000020001", "intro": "Failed to pull out the AMS-HT B Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1804010000020009", "intro": "AMS-HT E The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "1801210000020009", "intro": "Failed to extrude AMS-HT B Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800110000010001", "intro": "The AMS-HT A slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0300930000010002", "intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor may have an open circuit." }, { "ecode": "1800450000020001", "intro": "The filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in." }, { "ecode": "1805210000020009", "intro": "Failed to extrude AMS-HT F Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0703900000010003", "intro": "AMS D The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0702010000010005", "intro": "AMS C The current sensor of assist motor may be faulty." }, { "ecode": "1801230000020023", "intro": "AMS-HT B slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "18FF200000020004", "intro": "Please pull the external filament from the right extruder." }, { "ecode": "1801730000020005", "intro": "Failed to feed the AMS-HT B Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707550000010003", "intro": "AMS H was detected offline during the AMS initialization process." }, { "ecode": "1800910000010002", "intro": "AMS-HT A The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1801230000030002", "intro": "AMS-HT B Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704960000010003", "intro": "AMS E Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1803960000010003", "intro": "AMS-HT D Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "18FE800000020001", "intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead." }, { "ecode": "1203210000020004", "intro": "AMS D Slot2 filament may be broken in the tool head." }, { "ecode": "0705220000020012", "intro": "AMS F slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1802550000010004", "intro": "The binding between AMS-HT C and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "1807010000020007", "intro": "AMS-HT H The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0702210000020011", "intro": "AMS C slot 2 pulls filament back to AMS timeout." }, { "ecode": "0704210000020021", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1201220000030002", "intro": "AMS B Slot3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "03001C0000010001", "intro": "The extrusion motor driver is abnormal. The MOSFET may have a short circuit." }, { "ecode": "1803550000010004", "intro": "The binding between AMS-HT D and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0706220000020023", "intro": "AMS G slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807620000020001", "intro": "The AMS-HT H Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1804100000020002", "intro": "The AMS-HT E slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0700210000020011", "intro": "AMS A slot 2 pulls filament back to AMS timeout." }, { "ecode": "0701200000020011", "intro": "AMS B slot 1 pulls filament back to AMS timeout." }, { "ecode": "0700210000030001", "intro": "AMS A Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0701300000020002", "intro": "The RFID-tag on AMS B Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1804200000020004", "intro": "AMS-HT E Slot 1 filament may be broken in the tool head." }, { "ecode": "1200450000020002", "intro": "The filament cutter's cutting distance is too large. The X motor may lose steps." }, { "ecode": "1802130000020004", "intro": "AMS-HT C The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802940000010001", "intro": "AMS-HT C The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "070222000002000A", "intro": "Failed to adjust the filament position of AMS C Slot 3. The filament or buffer may be stuck." }, { "ecode": "1807220000020008", "intro": "AMS-HT H Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0707970000030001", "intro": "AMS H chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1800230000020011", "intro": "AMS-HT A slot 4 pulls filament back to AMS timeout." }, { "ecode": "1806230000020015", "intro": "AMS-HT G slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0707960000020002", "intro": "AMS H Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0700220000020002", "intro": "AMS A Slot 3 is empty; please insert a new filament." }, { "ecode": "1804230000020009", "intro": "Failed to extrude AMS-HT E Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "180323000002000A", "intro": "Failed to adjust the filament position of AMS-HT D Slot 4. The filament or buffer may be stuck." }, { "ecode": "0500060000020007", "intro": "" }, { "ecode": "1807200000020015", "intro": "AMS-HT H slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0706200000010081", "intro": "Failed to read the filament information from AMS G slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1801220000020019", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700110000020002", "intro": "The AMS A slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805230000020018", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1806230000010082", "intro": "Failed to read the filament information from AMS-HT G slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0707230000020012", "intro": "AMS H slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0707210000020015", "intro": "AMS H slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0500060000020024", "intro": "" }, { "ecode": "1807910000010003", "intro": "AMS-HT H The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "0703110000020002", "intro": "The AMS D slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1802350000010002", "intro": "AMS-HT C The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1805210000010083", "intro": "Failed to read the filament information from AMS-HT F slot 2. The RFID tag may be damaged." }, { "ecode": "0300D00000010002", "intro": "The blade holder has fallen off; please reinstall it." }, { "ecode": "1805900000010003", "intro": "AMS-HT F The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0703210000020002", "intro": "AMS D Slot 2 is empty; please insert a new filament." }, { "ecode": "1800130000020004", "intro": "AMS-HT A The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803310000010004", "intro": "Encryption chip failure" }, { "ecode": "0707560000030001", "intro": "AMS H is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "1200230000020004", "intro": "AMS A Slot4 filament may be broken in the tool head." }, { "ecode": "1202200000020004", "intro": "AMS C Slot1 filament may be broken in the tool head." }, { "ecode": "0701800000010003", "intro": "AMS B The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0300250000010004", "intro": "The signal of the extrusion force sensor of the right extruder is abnormal. The sensor may be damaged, or the MC-TH communication may be abnormal." }, { "ecode": "0500060000020033", "intro": "BirdsEye Camera is not connected. Please check the hardware and cable connections." }, { "ecode": "1200100000010001", "intro": "The AMS A Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0705110000020002", "intro": "The AMS F slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0701220000020010", "intro": "AMS B slot 3 feeds filament out of AMS timeout." }, { "ecode": "0703020000010001", "intro": "AMS D Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "180220000002000A", "intro": "Failed to adjust the filament position of AMS-HT C Slot 1. The filament or buffer may be stuck." }, { "ecode": "0700010000020011", "intro": "AMS A The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0580050000010010", "intro": "The firmware of AMS-HT A does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1200200000020004", "intro": "AMS A Slot1 filament may be broken in the tool head." }, { "ecode": "1801310000010004", "intro": "Encryption chip failure" }, { "ecode": "1802020000020002", "intro": "AMS-HT C The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1803200000020012", "intro": "AMS-HT D slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1803220000020008", "intro": "AMS-HT D Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701200000020009", "intro": "Failed to extrude AMS B Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800710000020004", "intro": "Failed to pull back the AMS-HT A Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703230000020018", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0705220000020007", "intro": "AMS F Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1801230000010086", "intro": "Failed to read the filament information from AMS-HT B slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0500040000020034", "intro": "Laser module detected for the first time. Complete the setup (~4 min) before use for precise cutting and engraving. Also, ensure the H2.0 screw at the back securing the air pump is removed." }, { "ecode": "1806200000020014", "intro": "AMS-HT G slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "03000A0000010003", "intro": "The signal of heatbed force sensor 1 is too weak. The electronic connection to the sensor may be broken." }, { "ecode": "0703620000020001", "intro": "The AMS D Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0700200000020021", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1807210000020011", "intro": "AMS-HT H slot 2 pulls filament back to AMS timeout." }, { "ecode": "1803700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0500040000020030", "intro": "The BirdsEye Camera is not installed. Please power off printer and then install the camera." }, { "ecode": "0703010000010011", "intro": "AMS D The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0704210000020001", "intro": "AMS E Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1201320000010001", "intro": "AMS B Slot 3 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0707930000020002", "intro": "AMS H The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1200450000020001", "intro": "The filament cutter sensor is malfunctioning. Please check whether the connector is properly plugged in." }, { "ecode": "1807730000020005", "intro": "Failed to feed the AMS-HT H Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0706230000020017", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1800310000010004", "intro": "Encryption chip failure" }, { "ecode": "0500050000010009", "intro": "" }, { "ecode": "0700230000020020", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0500010000020002", "intro": "Live View camera is not connected. Please check the hardware and cable connections." }, { "ecode": "0C00040000020007", "intro": "BirdsEye Camera is setting up. Please clear all objects and remove the mat. Make sure the marker is not obstructed. Meanwhile, clean both the BirdsEye Camera and Toolhead Camera, and remove any foreign objects blocking their view." }, { "ecode": "0702200000020010", "intro": "AMS C slot 1 feeds filament out of AMS timeout." }, { "ecode": "0703230000030002", "intro": "AMS D Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1800210000020018", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1803330000020002", "intro": "The RFID-tag on AMS-HT D Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1805100000020004", "intro": "AMS-HT F The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705220000020010", "intro": "AMS F slot 3 feeds filament out of AMS timeout." }, { "ecode": "0700710000020005", "intro": "Failed to feed the AMS A Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707230000020009", "intro": "Failed to extrude AMS H Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1801130000010001", "intro": "The AMS-HT B slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0706730000020001", "intro": "Failed to pull out the AMS G Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0706800000010002", "intro": "AMS G The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0701230000010086", "intro": "Failed to read the filament information from AMS B slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1804020000020002", "intro": "AMS-HT E The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0705210000020011", "intro": "AMS F slot 2 pulls filament back to AMS timeout." }, { "ecode": "1803010000010003", "intro": "The AMS-HT D assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700230000020016", "intro": "AMS A slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0704550000010003", "intro": "AMS E was detected offline during the AMS initialization process." }, { "ecode": "1806230000020002", "intro": "AMS-HT G Slot 4 is empty; please insert a new filament." }, { "ecode": "180021000002000A", "intro": "Failed to adjust the filament position of AMS-HT A Slot 2. The filament or buffer may be stuck." }, { "ecode": "0707220000020024", "intro": "AMS H slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0701010000010001", "intro": "The AMS B assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0700700000020004", "intro": "Failed to pull back the AMS A Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "050004000002001D", "intro": "The RFID-tag on AMS D Slot2 cannot be identified." }, { "ecode": "1800200000020005", "intro": "AMS-HT A Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0707210000020003", "intro": "AMS H Slot 2's filament may be broken in AMS." }, { "ecode": "0700230000020004", "intro": "AMS A Slot 4 filament may be broken in the tool head." }, { "ecode": "0705210000020001", "intro": "AMS F Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0703210000010086", "intro": "Failed to read the filament information from AMS D slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703010000010001", "intro": "The AMS D assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0C00040000020017", "intro": "The visual marker was not detected during PrintThenCut; please re-paste the material to the correct position. Meanwhile, please clean the Toolhead Camera to prevent contamination and remove any objects that may obstruct its view." }, { "ecode": "1805730000020002", "intro": "Failed to feed the AMS-HT F Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805220000020021", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "07FF810000010003", "intro": "The hall signal of the Extruder Switching Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "0701910000020001", "intro": "AMS B The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0707200000020002", "intro": "AMS H Slot 1 is empty; please insert a new filament." }, { "ecode": "1802600000020001", "intro": "The AMS-HT C Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0703720000020002", "intro": "Failed to feed the AMS D Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701220000020013", "intro": "AMS B slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705210000010082", "intro": "Failed to read the filament information from AMS F slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1801200000020003", "intro": "AMS-HT B Slot 1's filament may be broken in AMS-HT." }, { "ecode": "0700010000010003", "intro": "The AMS A assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1201100000010003", "intro": "The AMS B Slot1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703210000010084", "intro": "Failed to read the filament information from AMS D slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "07FF800000020003", "intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate." }, { "ecode": "1200100000010003", "intro": "The AMS A Slot1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0707930000010001", "intro": "AMS H The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0701930000020002", "intro": "AMS B The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1800230000020024", "intro": "AMS-HT A slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1801200000020024", "intro": "AMS-HT B slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807210000010084", "intro": "Failed to read the filament information from AMS-HT H slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1803220000020019", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700210000020012", "intro": "AMS A slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1200220000030002", "intro": "AMS A Slot3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1807210000020023", "intro": "AMS-HT H slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1202210000020003", "intro": "AMS C Slot2 filament may be broken in the PTFE tube." }, { "ecode": "0702010000020011", "intro": "AMS C The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1802230000030001", "intro": "AMS-HT C Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1806810000010004", "intro": "AMS-HT G The heater 2 is heating abnormally." }, { "ecode": "1807010000020010", "intro": "AMS-HT H The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0705350000010002", "intro": "AMS F The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800910000020001", "intro": "AMS-HT A The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0706300000020002", "intro": "The RFID-tag on AMS G Slot1 is damaged, or its content cannot be identified." }, { "ecode": "0706110000020004", "intro": "AMS G The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704200000020008", "intro": "AMS E Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0707700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1801710000020002", "intro": "Failed to feed the AMS-HT B Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1200200000020005", "intro": "AMS A Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0703200000020023", "intro": "AMS D slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0705200000020013", "intro": "AMS F slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807200000020012", "intro": "AMS-HT H slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0701800000010004", "intro": "AMS B The heater 1 is heating abnormally." }, { "ecode": "1801220000010083", "intro": "Failed to read the filament information from AMS-HT B slot 3. The RFID tag may be damaged." }, { "ecode": "1801200000010084", "intro": "Failed to read the filament information from AMS-HT B slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0705100000020004", "intro": "AMS F The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800730000020001", "intro": "Failed to pull out the AMS-HT A Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802010000020009", "intro": "AMS-HT C The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0700120000010003", "intro": "The AMS A slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0705560000030001", "intro": "AMS F is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0702700000020005", "intro": "Failed to feed the AMS C Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0502050000010010", "intro": "The firmware of AMS C does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0700010000020010", "intro": "AMS A The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0705210000010083", "intro": "Failed to read the filament information from AMS F slot 2. The RFID tag may be damaged." }, { "ecode": "0500010000030006", "intro": "The USB drive is not formatted or cannot be written; please format the USB drive." }, { "ecode": "0701210000020019", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1802210000030001", "intro": "AMS-HT C Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0707220000030002", "intro": "AMS H Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702130000020002", "intro": "The AMS C slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800720000020004", "intro": "Failed to pull back the AMS-HT A Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703220000020010", "intro": "AMS D slot 3 feeds filament out of AMS timeout." }, { "ecode": "0707620000020001", "intro": "The AMS H Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300010000010008", "intro": "An abnormality occurs during the heating process of the heatbed; the heating modules may be broken." }, { "ecode": "1804200000020012", "intro": "AMS-HT E slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800230000020009", "intro": "Failed to extrude AMS-HT A Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1806220000030002", "intro": "AMS-HT G Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0300900000010003", "intro": "Chamber heating failed. The power supply temperature may be too high." }, { "ecode": "1801810000010003", "intro": "AMS-HT B The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1805220000020005", "intro": "AMS-HT F Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "180023000002000A", "intro": "Failed to adjust the filament position of AMS-HT A Slot 4. The filament or buffer may be stuck." }, { "ecode": "0705920000010001", "intro": "AMS F The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1807200000020011", "intro": "AMS-HT H slot 1 pulls filament back to AMS timeout." }, { "ecode": "0706730000020005", "intro": "Failed to feed the AMS G Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1807810000010002", "intro": "AMS-HT H The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0704550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0300010000010006", "intro": "The heatbed temperature is abnormal; the sensor may have a short circuit." }, { "ecode": "1806220000020001", "intro": "AMS-HT G Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1202220000020002", "intro": "AMS C Slot 3 is empty; please insert a new filament." }, { "ecode": "1805230000020015", "intro": "AMS-HT F slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0702220000020019", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1203130000020002", "intro": "The AMS D Slot4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807720000020001", "intro": "Failed to pull out the AMS-HT H Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1203310000030003", "intro": "AMS D Slot2 RFID cannot be read because of a structural error." }, { "ecode": "0704200000020003", "intro": "AMS E Slot 1's filament may be broken in AMS." }, { "ecode": "0707210000030001", "intro": "AMS H Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0701550000010004", "intro": "The binding between AMS B and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "1806230000020019", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1807800000010002", "intro": "AMS-HT H The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0707220000020021", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802230000020021", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1800200000020016", "intro": "AMS-HT A slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0702220000020018", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0500040000020012", "intro": "The RFID-tag on AMS A Slot3 cannot be identified." }, { "ecode": "1807700000020004", "intro": "Failed to pull back the AMS-HT H Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "07FF800000020001", "intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead." }, { "ecode": "0707920000010001", "intro": "AMS H The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "0702230000010081", "intro": "Failed to read the filament information from AMS C slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0706320000020002", "intro": "The RFID-tag on AMS G Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1803210000010081", "intro": "Failed to read the filament information from AMS-HT D slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1802720000020005", "intro": "Failed to feed the AMS-HT C Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0705970000030001", "intro": "AMS F chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0706230000020015", "intro": "AMS G slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0704200000010082", "intro": "Failed to read the filament information from AMS E slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1203220000030002", "intro": "AMS D Slot3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1800730000020004", "intro": "Failed to pull back the AMS-HT A Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "18FF800000010006", "intro": "The TH board disconnected during the extruder switching process. Please check if the connecting cable is loose." }, { "ecode": "0705550000010004", "intro": "The binding between AMS F and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0705220000020015", "intro": "AMS F slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "07FE800000010001", "intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose." }, { "ecode": "0703810000010002", "intro": "AMS D The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0707010000020009", "intro": "AMS H The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0702230000020009", "intro": "Failed to extrude AMS C Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0300900000010001", "intro": "Chamber heating failed. The heater may not be blowing hot air." }, { "ecode": "1803200000020015", "intro": "AMS-HT D slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1804220000010082", "intro": "Failed to read the filament information from AMS-HT E slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0702100000020004", "intro": "AMS C The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707210000020011", "intro": "AMS H slot 2 pulls filament back to AMS timeout." }, { "ecode": "1802220000020023", "intro": "AMS-HT C slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0500040000020016", "intro": "The RFID-tag on AMS B Slot3 cannot be identified." }, { "ecode": "1802230000020005", "intro": "AMS-HT C Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0703220000020002", "intro": "AMS D Slot 3 is empty; please insert a new filament." }, { "ecode": "1807210000010083", "intro": "Failed to read the filament information from AMS-HT H slot 2. The RFID tag may be damaged." }, { "ecode": "1800210000020002", "intro": "AMS-HT A Slot 2 is empty; please insert a new filament." }, { "ecode": "1201720000010001", "intro": "AMS B Filament speed and length error: The slot 3 filament odometry may be faulty." }, { "ecode": "180221000002000A", "intro": "Failed to adjust the filament position of AMS-HT C Slot 2. The filament or buffer may be stuck." }, { "ecode": "0707220000020015", "intro": "AMS H slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0300950000010004", "intro": "The speed of the Laser Module cooling fan is too low or stopped. It may be stuck or the connector may not be plugged in properly." }, { "ecode": "1803900000010003", "intro": "AMS-HT D The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0704310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1800220000020010", "intro": "AMS-HT A slot 3 feeds filament out of AMS timeout." }, { "ecode": "1805220000020020", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701210000020020", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1801960000010001", "intro": "AMS-HT B The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "03000A0000010001", "intro": "Heatbed force sensor 1 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight." }, { "ecode": "0706310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0707230000020008", "intro": "AMS H Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0703700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1805940000010001", "intro": "AMS-HT F The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0500040000020042", "intro": "The Live View Camera is dirty or obstructed; please clean it and continue." }, { "ecode": "1805930000010001", "intro": "AMS-HT F The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "18FE810000010004", "intro": "The position hall sensor of the Extruder Switching Motor has a short circuit; please check if the Hall sensor is malfunctioning." }, { "ecode": "1202700000010001", "intro": "AMS C Filament speed and length error: The slot 1 filament odometry may be faulty." }, { "ecode": "1804200000020017", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0700210000020019", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1805700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "07FE800000010003", "intro": "The hall signal of the Toolhead Lifting Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "0705700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0701220000020015", "intro": "AMS B slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0707350000010002", "intro": "AMS H The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704200000010086", "intro": "Failed to read the filament information from AMS E slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1806230000020005", "intro": "AMS-HT G Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1801010000010003", "intro": "The AMS-HT B assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801500000020001", "intro": "AMS-HT B communication is abnormal; please check the connection cable." }, { "ecode": "1800600000020001", "intro": "The AMS-HT A Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1801210000020022", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0707220000020023", "intro": "AMS H slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1201200000020002", "intro": "AMS B Slot 1 is empty; please insert a new filament." }, { "ecode": "0706220000010085", "intro": "Failed to read the filament information from AMS G slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0300990000030001", "intro": "The right side window is detected to be open." }, { "ecode": "1802200000020020", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701550000010003", "intro": "AMS B was detected offline during the AMS initialization process." }, { "ecode": "0300100000020001", "intro": "The resonance frequency of the X axis is low. The timing belt may be loose." }, { "ecode": "0707220000020004", "intro": "AMS H Slot 3 filament may be broken in the tool head." }, { "ecode": "0705940000010001", "intro": "AMS F The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0C00010000020016", "intro": "" }, { "ecode": "0706230000010081", "intro": "Failed to read the filament information from AMS G slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1806110000010001", "intro": "The AMS-HT G slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0706210000020011", "intro": "AMS G slot 2 pulls filament back to AMS timeout." }, { "ecode": "1203220000020005", "intro": "AMS D Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0706230000010083", "intro": "Failed to read the filament information from AMS G slot 4. The RFID tag may be damaged." }, { "ecode": "1803010000020011", "intro": "AMS-HT D The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0704230000020009", "intro": "Failed to extrude AMS E Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800230000010083", "intro": "Failed to read the filament information from AMS-HT A slot 4. The RFID tag may be damaged." }, { "ecode": "0701350000010002", "intro": "AMS B The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1203200000020005", "intro": "AMS D Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0500040000020031", "intro": "Before using a Laser/Cutting Module, the pose of the BirdsEye Camera needs to be determined. Please complete the setup to calibrate the camera." }, { "ecode": "0701010000020006", "intro": "AMS B The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "070023000002000A", "intro": "Failed to adjust the filament position of AMS A Slot 4. The filament or buffer may be stuck." }, { "ecode": "1804910000010002", "intro": "AMS-HT E The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1804230000020015", "intro": "AMS-HT E slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1806220000030001", "intro": "AMS-HT G Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0700100000020002", "intro": "The AMS A slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707730000020002", "intro": "Failed to feed the AMS H Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0705120000010003", "intro": "The AMS F slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703230000020005", "intro": "AMS D Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1802810000010003", "intro": "AMS-HT C The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0704220000020024", "intro": "AMS E slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1806200000020015", "intro": "AMS-HT G slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700010000020007", "intro": "AMS A The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1803010000020002", "intro": "The AMS-HT D assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705200000020015", "intro": "AMS F slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0706110000010003", "intro": "The AMS G slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0500030000020013", "intro": "" }, { "ecode": "0702200000020008", "intro": "AMS C Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800550000010003", "intro": "AMS-HT A was detected offline during the AMS initialization process." }, { "ecode": "0706210000010085", "intro": "Failed to read the filament information from AMS G slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0704200000020010", "intro": "AMS E slot 1 feeds filament out of AMS timeout." }, { "ecode": "1202320000020002", "intro": "The RFID-tag on AMS C Slot 3 is damaged." }, { "ecode": "0701020000020002", "intro": "AMS B The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0707010000020002", "intro": "The AMS H assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1201800000020001", "intro": "AMS B Slot1 filament may be tangled or stuck." }, { "ecode": "0700230000030002", "intro": "AMS A Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702010000010004", "intro": "The AMS C assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1805220000030001", "intro": "AMS-HT F Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800200000010081", "intro": "Failed to read the filament information from AMS-HT A slot 1. The AMS main board may be malfunctioning." }, { "ecode": "0C00030000020014", "intro": "Foreign object detection accuracy has decreased. If this occurs frequently, perform a Live View Camera calibration (“Settings” > “Calibration” on the printer screen). If a laser or cutting module is installed, remove it before proceeding." }, { "ecode": "1807960000010003", "intro": "AMS-HT H Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0300360000010001", "intro": "The Chamber Heat Circulation Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "1805230000020013", "intro": "AMS-HT F slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801210000020015", "intro": "AMS-HT B slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0705230000020011", "intro": "AMS F slot 4 pulls filament back to AMS timeout." }, { "ecode": "0704010000020009", "intro": "AMS E The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0702220000020016", "intro": "AMS C slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1804230000020020", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0700350000010002", "intro": "AMS A The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701010000010003", "intro": "The AMS B assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0705220000020016", "intro": "AMS F slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1801220000020008", "intro": "AMS-HT B Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1804200000020010", "intro": "AMS-HT E slot 1 feeds filament out of AMS timeout." }, { "ecode": "1802210000020009", "intro": "Failed to extrude AMS-HT C Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807210000020013", "intro": "AMS-HT H slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1805300000010004", "intro": "Encryption chip failure" }, { "ecode": "1804800000010002", "intro": "AMS-HT E The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1802710000020001", "intro": "Failed to pull out the AMS-HT C Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0500030000010021", "intro": "Hardware incompatible; please check the Toolhead Camera." }, { "ecode": "1800210000020015", "intro": "AMS-HT A slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0704110000020004", "intro": "AMS E The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803300000010004", "intro": "Encryption chip failure" }, { "ecode": "0704230000020014", "intro": "AMS E slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1202120000020002", "intro": "The AMS C Slot3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0701230000020014", "intro": "AMS B slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0700220000010083", "intro": "Failed to read the filament information from AMS A slot 3. The RFID tag may be damaged." }, { "ecode": "1802700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0701200000020010", "intro": "AMS B slot 1 feeds filament out of AMS timeout." }, { "ecode": "1801230000020021", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1805230000020008", "intro": "AMS-HT F Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0702200000020009", "intro": "Failed to extrude AMS C Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1200200000030002", "intro": "AMS A Slot1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1803900000020001", "intro": "AMS-HT D The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1801120000020004", "intro": "AMS-HT B The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704730000020001", "intro": "Failed to pull out the AMS E Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1806230000010083", "intro": "Failed to read the filament information from AMS-HT G slot 4. The RFID tag may be damaged." }, { "ecode": "1806700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1800930000010001", "intro": "AMS-HT A The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0C0003000002000F", "intro": "Parts skipped before first layer inspection; the inspection is not supported for the current print." }, { "ecode": "1802220000010085", "intro": "Failed to read the filament information from AMS-HT C slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1203220000020002", "intro": "AMS D Slot 3 is empty; please insert a new filament." }, { "ecode": "1801330000020002", "intro": "The RFID-tag on AMS-HT B Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1803810000010001", "intro": "AMS-HT D The current sensor of heater 2 is abnormal." }, { "ecode": "0700730000020001", "intro": "Failed to pull out the AMS A Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0702250000020001", "intro": "AMS C uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0705220000020020", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1804200000010082", "intro": "Failed to read the filament information from AMS-HT E slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1200800000020001", "intro": "AMS A Slot1 filament may be tangled or stuck." }, { "ecode": "1803210000020016", "intro": "AMS-HT D slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0300010000010007", "intro": "The heatbed temperature is abnormal; the sensor may have an open circuit." }, { "ecode": "0703220000020017", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1800720000020005", "intro": "Failed to feed the AMS-HT A Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1804230000020017", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0704930000010001", "intro": "AMS E The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "1203710000010001", "intro": "AMS D Filament speed and length error: The slot 2 filament odometry may be faulty." }, { "ecode": "1806230000020003", "intro": "AMS-HT G Slot 4's filament may be broken in AMS-HT." }, { "ecode": "1201710000010001", "intro": "AMS B Filament speed and length error: The slot 2 filament odometry may be faulty." }, { "ecode": "050003000001000C", "intro": "The MC motor controller module is malfunctioning. Please power off, check the connection, and restart the device." }, { "ecode": "070221000002000A", "intro": "Failed to adjust the filament position of AMS C Slot 2. The filament or buffer may be stuck." }, { "ecode": "0707020000010001", "intro": "AMS H Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0704120000020002", "intro": "The AMS E slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1806200000020019", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1807700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1801320000020002", "intro": "The RFID-tag on AMS-HT B Slot3 is damaged, or its content cannot be identified." }, { "ecode": "18FF800000020002", "intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model." }, { "ecode": "1801200000020021", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802810000010002", "intro": "AMS-HT C The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0706700000020001", "intro": "Failed to pull out the AMS G Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0704960000020002", "intro": "AMS E Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0706330000020002", "intro": "The RFID-tag on AMS G Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1804200000020016", "intro": "AMS-HT E slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1804560000030001", "intro": "AMS-HT E is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0700800000010004", "intro": "AMS A The heater 1 is heating abnormally." }, { "ecode": "0701220000030002", "intro": "AMS B Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0703500000020001", "intro": "AMS D communication is abnormal; please check the connection cable." }, { "ecode": "0300250000010002", "intro": "The sensitivity of the right extruder extrusion force sensor is low; the nozzle may not installed correctly." }, { "ecode": "0706220000020015", "intro": "AMS G slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0500040000020033", "intro": "Please plug in the module connector." }, { "ecode": "1200310000030003", "intro": "AMS A Slot2 RFID cannot be read because of a structural error." }, { "ecode": "0706200000020004", "intro": "AMS G Slot 1 filament may be broken in the tool head." }, { "ecode": "030026000001000B", "intro": "Nozzle presence detection failed: Left extruder nozzle not installed or improperly installed." }, { "ecode": "0300310000020002", "intro": "The Part Cooling Fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "0706230000030001", "intro": "AMS G Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1802900000010003", "intro": "AMS-HT C The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0704210000010086", "intro": "Failed to read the filament information from AMS E slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0706970000030001", "intro": "AMS G chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1802200000020018", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804210000010085", "intro": "Failed to read the filament information from AMS-HT E slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0707210000010086", "intro": "Failed to read the filament information from AMS H slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1200230000020006", "intro": "Failed to extrude AMS A Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0704200000020023", "intro": "AMS E slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1800200000020017", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "070122000002000A", "intro": "Failed to adjust the filament position of AMS B Slot 3. The filament or buffer may be stuck." }, { "ecode": "1805200000020010", "intro": "AMS-HT F slot 1 feeds filament out of AMS timeout." }, { "ecode": "1803010000020007", "intro": "AMS-HT D The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1807220000020019", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1804230000020021", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0300980000010002", "intro": "The left side window Hall sensor (Upper) is abnormal; please check whether the connection wire is loose." }, { "ecode": "1803010000010005", "intro": "AMS-HT D The current sensor of assist motor may be faulty." }, { "ecode": "0706800000010001", "intro": "AMS G The current sensor of heater 1 is abnormal." }, { "ecode": "0705200000010083", "intro": "Failed to read the filament information from AMS F slot 1. The RFID tag may be damaged." }, { "ecode": "1800500000020001", "intro": "AMS-HT A communication is abnormal; please check the connection cable." }, { "ecode": "0702220000030001", "intro": "AMS C Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800220000020019", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1800300000010001", "intro": "The AMS-HT A RFID 1 board has an error." }, { "ecode": "0703910000010002", "intro": "AMS D The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0702300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1801210000020012", "intro": "AMS-HT B slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800960000020002", "intro": "AMS-HT A Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0704800000010001", "intro": "AMS E The current sensor of heater 1 is abnormal." }, { "ecode": "0702110000010003", "intro": "The AMS C slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "07FF450000020002", "intro": "The filament cutter's cutting distance is too large. Possible causes include the filament cutter stopper skipping teeth, motor losing steps, or the XY axis not being homed." }, { "ecode": "0702210000020017", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0704230000010082", "intro": "Failed to read the filament information from AMS E slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0705720000020005", "intro": "Failed to feed the AMS F Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1801800000010002", "intro": "AMS-HT B The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1800220000020008", "intro": "AMS-HT A Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0706010000010004", "intro": "The AMS G assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "0705800000010004", "intro": "AMS F The heater 1 is heating abnormally." }, { "ecode": "0705210000020003", "intro": "AMS F Slot 2's filament may be broken in AMS." }, { "ecode": "0704120000010003", "intro": "The AMS E slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0700230000020010", "intro": "AMS A slot 4 feeds filament out of AMS timeout." }, { "ecode": "0500020000020004", "intro": "Unauthorized user: please check your account information." }, { "ecode": "1806200000020005", "intro": "AMS-HT G Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0705210000020009", "intro": "Failed to extrude AMS F Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807200000020018", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1200130000010001", "intro": "The AMS A Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702230000020008", "intro": "AMS C Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0702220000020001", "intro": "AMS C Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1803220000020021", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0706220000020001", "intro": "AMS G Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0700020000010001", "intro": "AMS A Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0702210000030001", "intro": "AMS C Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1801230000020022", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1805230000020009", "intro": "Failed to extrude AMS-HT F Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0702230000020020", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701010000020011", "intro": "AMS B The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0701210000020001", "intro": "AMS B Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1801230000030001", "intro": "AMS-HT B Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0700400000020002", "intro": "Filament buffer position signal error: the position sensor may be malfunctioning." }, { "ecode": "0707230000010086", "intro": "Failed to read the filament information from AMS H slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1800620000020001", "intro": "The AMS-HT A Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800610000020001", "intro": "The AMS-HT A Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "07FF700000020003", "intro": "Please check if the material is coming out of the right nozzle. If not, gently push the material and try to extrude again." }, { "ecode": "0300100000020002", "intro": "The resonance frequency of the X-axis differs significantly from the last calibration. Please clean the X-axis linear rail and conduct a calibration after printing." }, { "ecode": "0705010000020006", "intro": "AMS F The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0705960000020002", "intro": "AMS F Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1800560000030001", "intro": "AMS-HT A is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0700630000020001", "intro": "The AMS A Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1801810000010002", "intro": "AMS-HT B The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0702700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0706720000020002", "intro": "Failed to feed the AMS G Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1203100000020002", "intro": "The AMS D Slot1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805220000020015", "intro": "AMS-HT F slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700130000020002", "intro": "The AMS A slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1201320000020002", "intro": "The RFID-tag on AMS B Slot 3 is damaged." }, { "ecode": "1203830000020001", "intro": "AMS D Slot4 filament may be tangled or stuck." }, { "ecode": "0704010000020007", "intro": "AMS E The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1803210000020007", "intro": "AMS-HT D Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "050003000001000B", "intro": "The screen is malfunctioning; please restart the device." }, { "ecode": "1804200000020018", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "03009C0000010001", "intro": "The Air Pump is not detected. Please check whether the connector is plugged in properly." }, { "ecode": "0705210000020007", "intro": "AMS F Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1806710000020005", "intro": "Failed to feed the AMS-HT G Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1804700000020004", "intro": "Failed to pull back the AMS-HT E Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "070723000002000A", "intro": "Failed to adjust the filament position of AMS H Slot 4. The filament or buffer may be stuck." }, { "ecode": "1800700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1806800000010004", "intro": "AMS-HT G The heater 1 is heating abnormally." }, { "ecode": "1805710000020004", "intro": "Failed to pull back the AMS-HT F Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803210000010082", "intro": "Failed to read the filament information from AMS-HT D slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0706310000010001", "intro": "The AMS G RFID 2 board has an error." }, { "ecode": "1803010000020006", "intro": "AMS-HT D The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1200300000020002", "intro": "The RFID-tag on AMS A Slot 1 is damaged." }, { "ecode": "0C00030000020016", "intro": "Foreign object detection is not working and the Live View camera serial number cannot be read. Please contact the customer support team." }, { "ecode": "1801130000020004", "intro": "AMS-HT B The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700200000020007", "intro": "AMS A Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1804230000020008", "intro": "AMS-HT E Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1802920000020002", "intro": "AMS-HT C The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0703210000020018", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1200210000020001", "intro": "AMS A Slot2 filament has run out; please insert a new filament." }, { "ecode": "0500060000020011", "intro": "" }, { "ecode": "0300920000010003", "intro": "The temperature of chamber heater 2 is abnormal. The heater is over temperature." }, { "ecode": "0702200000020015", "intro": "AMS C slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0702300000010001", "intro": "The AMS C RFID 1 board has an error." }, { "ecode": "1803550000010003", "intro": "AMS-HT D was detected offline during the AMS initialization process." }, { "ecode": "0702630000020001", "intro": "The AMS C Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702110000020002", "intro": "The AMS C slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "050005000001000C", "intro": "" }, { "ecode": "1802010000020008", "intro": "AMS-HT C The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1801230000020010", "intro": "AMS-HT B slot 4 feeds filament out of AMS timeout." }, { "ecode": "0706220000020013", "intro": "AMS G slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "03000C0000010004", "intro": "An external disturbance was detected on force sensor 3. The heatbed plate may have touched something outside the heatbed." }, { "ecode": "1807220000020010", "intro": "AMS-HT H slot 3 feeds filament out of AMS timeout." }, { "ecode": "1804230000020023", "intro": "AMS-HT E slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1201210000020003", "intro": "AMS B Slot2 filament may be broken in the PTFE tube." }, { "ecode": "0702800000010001", "intro": "AMS C The current sensor of heater 1 is abnormal." }, { "ecode": "1800200000020022", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0706230000020014", "intro": "AMS G slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1802220000020011", "intro": "AMS-HT C slot 3 pulls filament back to AMS timeout." }, { "ecode": "1804210000030002", "intro": "AMS-HT E Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0701720000020002", "intro": "Failed to feed the AMS B Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0300320000010001", "intro": "The Auxiliary Part Cooling Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "1804220000020014", "intro": "AMS-HT E slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0707230000020003", "intro": "AMS H Slot 4's filament may be broken in AMS." }, { "ecode": "1803200000020006", "intro": "AMS-HT D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1800210000020011", "intro": "AMS-HT A slot 2 pulls filament back to AMS timeout." }, { "ecode": "0703210000020014", "intro": "AMS D slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704200000020024", "intro": "AMS E slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0706210000020019", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706100000010003", "intro": "The AMS G slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703230000020008", "intro": "AMS D Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0707010000020008", "intro": "AMS H The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "07FE700000020003", "intro": "Please check if the material is coming out of the left nozzle. If not, gently push the material and try to extrude again." }, { "ecode": "0703100000010003", "intro": "The AMS D slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0300A40000010003", "intro": "The left hotend temperature is too high. Please wait for it to cool down to room temperature before restarting the task." }, { "ecode": "0702210000010085", "intro": "Failed to read the filament information from AMS C slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1805310000020002", "intro": "The RFID-tag on AMS-HT F Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0704920000020002", "intro": "AMS E The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0702230000020003", "intro": "AMS C Slot 4's filament may be broken in AMS." }, { "ecode": "1805710000020002", "intro": "Failed to feed the AMS-HT F Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0500040000010051", "intro": "Emergency Stop Button is not in the right position. Please follow the Wiki to install it." }, { "ecode": "1201810000020001", "intro": "AMS B Slot2 filament may be tangled or stuck." }, { "ecode": "0703210000010082", "intro": "Failed to read the filament information from AMS D slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1804200000010086", "intro": "Failed to read the filament information from AMS-HT E slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703930000020002", "intro": "AMS D The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "0701210000020014", "intro": "AMS B slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1803010000010011", "intro": "AMS-HT D The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1806220000020008", "intro": "AMS-HT G Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1801200000020005", "intro": "AMS-HT B Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1804010000020002", "intro": "The AMS-HT E assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807220000010084", "intro": "Failed to read the filament information from AMS-HT H slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0702550000010003", "intro": "AMS C was detected offline during the AMS initialization process." }, { "ecode": "1801230000020020", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0703310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0703200000030001", "intro": "AMS D Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0300080000010001", "intro": "Motor-Z has an open-circuit. The connection may be loose, or the motor may have failed." }, { "ecode": "1802200000020004", "intro": "AMS-HT C Slot 1 filament may be broken in the tool head." }, { "ecode": "1200110000010003", "intro": "The AMS A Slot2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700210000020001", "intro": "AMS A Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1800300000020002", "intro": "The RFID-tag on AMS-HT A Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1800700000020002", "intro": "Failed to feed the AMS-HT A Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804210000020010", "intro": "AMS-HT E slot 2 feeds filament out of AMS timeout." }, { "ecode": "0300910000010007", "intro": "The temperature of chamber heater 1 is abnormal. The sensor may have an open circuit." }, { "ecode": "0705730000020004", "intro": "Failed to pull back the AMS F Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "18FE450000020002", "intro": "The filament cutter's cutting distance is too large. Possible causes include the filament cutter stopper skipping teeth, motor losing steps, or the XY axis not being homed." }, { "ecode": "1802200000010081", "intro": "Failed to read the filament information from AMS-HT C slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1802200000010083", "intro": "Failed to read the filament information from AMS-HT C slot 1. The RFID tag may be damaged." }, { "ecode": "0707210000020013", "intro": "AMS H slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0706710000020002", "intro": "Failed to feed the AMS G Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804010000010001", "intro": "The AMS-HT E assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "1806300000020002", "intro": "The RFID-tag on AMS-HT G Slot1 is damaged, or its content cannot be identified." }, { "ecode": "18FE810000020001", "intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead." }, { "ecode": "0701200000010083", "intro": "Failed to read the filament information from AMS B slot 1. The RFID tag may be damaged." }, { "ecode": "0707710000020004", "intro": "Failed to pull back the AMS H Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1801550000010003", "intro": "AMS-HT B was detected offline during the AMS initialization process." }, { "ecode": "1803200000020011", "intro": "AMS-HT D slot 1 pulls filament back to AMS timeout." }, { "ecode": "0700110000010001", "intro": "The AMS A slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702220000010085", "intro": "Failed to read the filament information from AMS C slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804210000020005", "intro": "AMS-HT E Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1201210000020004", "intro": "AMS B Slot2 filament may be broken in the tool head." }, { "ecode": "1806920000010001", "intro": "AMS-HT G The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "0703920000020002", "intro": "AMS D The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0705010000010011", "intro": "AMS F The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0705120000020002", "intro": "The AMS F slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704800000010003", "intro": "AMS E The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0300280000010004", "intro": "The force sensor of the Cutting Module is abnormal. The force sensor cable may be disconnected or the force sensor is damaged." }, { "ecode": "0300920000010002", "intro": "The temperature of chamber heater 2 is abnormal. The heater may have an open circuit or the thermal fuse may be in effect." }, { "ecode": "1805200000010085", "intro": "Failed to read the filament information from AMS-HT F slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0705230000020013", "intro": "AMS F slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707200000020013", "intro": "AMS H slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803100000010003", "intro": "The AMS-HT D slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0702200000020021", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1807220000020022", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1807020000020002", "intro": "AMS-HT H The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1803720000020004", "intro": "Failed to pull back the AMS-HT D Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1806730000020004", "intro": "Failed to pull back the AMS-HT G Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704220000020015", "intro": "AMS E slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1803220000020023", "intro": "AMS-HT D slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1804100000010003", "intro": "The AMS-HT E slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703220000020007", "intro": "AMS D Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0701110000010003", "intro": "The AMS B slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1807200000020022", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1806310000020002", "intro": "The RFID-tag on AMS-HT G Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0300910000010006", "intro": "The temperature of chamber heater 1 is abnormal. The sensor may have a short circuit." }, { "ecode": "1803210000020012", "intro": "AMS-HT D slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "180623000002000A", "intro": "Failed to adjust the filament position of AMS-HT G Slot 4. The filament or buffer may be stuck." }, { "ecode": "0700310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1201220000020002", "intro": "AMS B Slot 3 is empty; please insert a new filament." }, { "ecode": "1203720000010001", "intro": "AMS D Filament speed and length error: The slot 3 filament odometry may be faulty." }, { "ecode": "1807300000020002", "intro": "The RFID-tag on AMS-HT H Slot1 is damaged, or its content cannot be identified." }, { "ecode": "12FF200000020004", "intro": "Please pull the filament on the spool holder out from the extruder." }, { "ecode": "1805010000020009", "intro": "AMS-HT F The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0701620000020001", "intro": "The AMS B Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "070620000002000A", "intro": "Failed to adjust the filament position of AMS G Slot 1. The filament or buffer may be stuck." }, { "ecode": "0705200000020007", "intro": "AMS F Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1805720000020002", "intro": "Failed to feed the AMS-HT F Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1203210000020001", "intro": "AMS D Slot2 filament has run out; please insert a new filament." }, { "ecode": "1800710000020002", "intro": "Failed to feed the AMS-HT A Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1807230000030002", "intro": "AMS-HT H Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1800130000020002", "intro": "The AMS-HT A slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707210000020022", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1800200000020012", "intro": "AMS-HT A slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1801230000020014", "intro": "AMS-HT B slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1804230000010085", "intro": "Failed to read the filament information from AMS-HT E slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1801970000030001", "intro": "AMS-HT B chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "03000A0000010002", "intro": "The signal of heatbed force sensor 1 is weak. The force sensor may be broken or have poor electric connection." }, { "ecode": "0706220000020004", "intro": "AMS G Slot 3 filament may be broken in the tool head." }, { "ecode": "0705220000030001", "intro": "AMS F Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0707810000010004", "intro": "AMS H The heater 2 is heating abnormally." }, { "ecode": "0705230000020024", "intro": "AMS F slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0702200000020023", "intro": "AMS C slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1800230000020010", "intro": "AMS-HT A slot 4 feeds filament out of AMS timeout." }, { "ecode": "0701200000020024", "intro": "AMS B slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802200000030001", "intro": "AMS-HT C Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0702700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1804220000020004", "intro": "AMS-HT E Slot 3 filament may be broken in the tool head." }, { "ecode": "0705010000010003", "intro": "The AMS F assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804210000020003", "intro": "AMS-HT E Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1800400000020002", "intro": "Filament buffer position signal error: the position sensor may be malfunctioning." }, { "ecode": "0701700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1807710000020002", "intro": "Failed to feed the AMS-HT H Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1807210000010085", "intro": "Failed to read the filament information from AMS-HT H slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1806350000010002", "intro": "AMS-HT G The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700230000020015", "intro": "AMS A slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1200200000020003", "intro": "AMS A Slot1 filament may be broken in the PTFE tube." }, { "ecode": "1202230000020003", "intro": "AMS C Slot4 filament may be broken in the PTFE tube." }, { "ecode": "1801220000020012", "intro": "AMS-HT B slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704200000020020", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1800100000010003", "intro": "The AMS-HT A slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703900000020001", "intro": "AMS D The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "0707220000010083", "intro": "Failed to read the filament information from AMS H slot 3. The RFID tag may be damaged." }, { "ecode": "1804220000020022", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "12FF200000020002", "intro": "Filament on the spool holder is empty; please insert a new filament." }, { "ecode": "0700320000020002", "intro": "The RFID-tag on AMS A Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1807230000010083", "intro": "Failed to read the filament information from AMS-HT H slot 4. The RFID tag may be damaged." }, { "ecode": "0704800000010002", "intro": "AMS E The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1805800000010004", "intro": "AMS-HT F The heater 1 is heating abnormally." }, { "ecode": "1804310000010004", "intro": "Encryption chip failure" }, { "ecode": "1201830000020001", "intro": "AMS B Slot4 filament may be tangled or stuck." }, { "ecode": "0701210000030001", "intro": "AMS B Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0701010000010004", "intro": "The AMS B assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "03009D0000020001", "intro": "The engrave laser focal point XY calibration has failed. Please clean up the Laser Homing Area on the Laser Platform, and re-run the Laser Module Mount Calibration." }, { "ecode": "1803240000020009", "intro": "AMS-HT D front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "0706220000030001", "intro": "AMS G Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0500060000020061", "intro": "" }, { "ecode": "0707730000020004", "intro": "Failed to pull back the AMS H Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800010000020002", "intro": "The AMS-HT A assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807010000010004", "intro": "The AMS-HT H assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "070722000002000A", "intro": "Failed to adjust the filament position of AMS H Slot 3. The filament or buffer may be stuck." }, { "ecode": "0704010000010001", "intro": "The AMS E assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0701220000020014", "intro": "AMS B slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1806210000020019", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700950000010001", "intro": "AMS A The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1805220000020007", "intro": "AMS-HT F Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1805230000020001", "intro": "AMS-HT F Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1801550000010004", "intro": "The binding between AMS-HT B and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "1801200000020018", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804960000010001", "intro": "AMS-HT E The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0704200000020018", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1800210000010083", "intro": "Failed to read the filament information from AMS-HT A slot 2. The RFID tag may be damaged." }, { "ecode": "0701230000020019", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0500040000020039", "intro": "Please plug in the module connector" }, { "ecode": "1804300000020002", "intro": "The RFID-tag on AMS-HT E Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1800800000010001", "intro": "AMS-HT A The current sensor of heater 1 is abnormal." }, { "ecode": "1801220000010084", "intro": "Failed to read the filament information from AMS-HT B slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706010000020010", "intro": "AMS G The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1807210000020018", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0700230000010083", "intro": "Failed to read the filament information from AMS A slot 4. The RFID tag may be damaged." }, { "ecode": "1201220000020001", "intro": "AMS B Slot3 filament has run out; please insert a new filament." }, { "ecode": "1803210000030001", "intro": "AMS-HT D Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0702200000020001", "intro": "AMS C Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1801210000020007", "intro": "AMS-HT B Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0300250000010007", "intro": "The frequency of the extrusion force sensor of the right extruder is too high. The sensor may be damaged, or the nozzle heat sink may be too close to the sensor." }, { "ecode": "0706620000020001", "intro": "The AMS G Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1801920000020002", "intro": "AMS-HT B The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0702620000020001", "intro": "The AMS C Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806920000020002", "intro": "AMS-HT G The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0706700000020004", "intro": "Failed to pull back the AMS G Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703930000010001", "intro": "AMS D The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "1802200000020015", "intro": "AMS-HT C slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1805200000020006", "intro": "AMS-HT F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0701010000020009", "intro": "AMS B The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0707700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1804200000010084", "intro": "Failed to read the filament information from AMS-HT E slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0700230000020002", "intro": "AMS A Slot 4 is empty; please insert a new filament." }, { "ecode": "0700230000020018", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0707130000010003", "intro": "The AMS H slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "03001E0000010003", "intro": "The left nozzle temperature is abnormal; the heater is overheated." }, { "ecode": "0704210000010085", "intro": "Failed to read the filament information from AMS E slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0703010000010005", "intro": "AMS D The current sensor of assist motor may be faulty." }, { "ecode": "1803310000010001", "intro": "The AMS-HT D RFID 2 board has an error." }, { "ecode": "0706910000010003", "intro": "AMS G The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "0704600000020001", "intro": "The AMS E Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "050005000001000B", "intro": "" }, { "ecode": "0700600000020001", "intro": "The AMS A Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1807220000020018", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0702320000020002", "intro": "The RFID-tag on AMS C Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0300260000010004", "intro": "The signal of the extrusion force sensor of the left extruder is abnormal. The sensor may be damaged, or the MC-TH communication may be abnormal." }, { "ecode": "1804700000020001", "intro": "Failed to pull out the AMS-HT E Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1801700000020001", "intro": "Failed to pull out the AMS-HT B Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0700230000020017", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1806230000020014", "intro": "AMS-HT G slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0701310000020002", "intro": "The RFID-tag on AMS B Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0704230000020010", "intro": "AMS E slot 4 feeds filament out of AMS timeout." }, { "ecode": "0702100000010001", "intro": "The AMS C slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0700200000010081", "intro": "Failed to read the filament information from AMS A slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1201200000020005", "intro": "AMS B Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0707110000010001", "intro": "The AMS H slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1805220000020019", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700220000020016", "intro": "AMS A slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1806900000010002", "intro": "AMS-HT G The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0706550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0703230000020002", "intro": "AMS D Slot 4 is empty; please insert a new filament." }, { "ecode": "0707900000020001", "intro": "AMS H The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1800210000020005", "intro": "AMS-HT A Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1203100000010003", "intro": "The AMS D Slot1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0705320000020002", "intro": "The RFID-tag on AMS F Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0706220000020024", "intro": "AMS G slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1804210000020022", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1802210000020020", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0704230000010081", "intro": "Failed to read the filament information from AMS E slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0701220000020008", "intro": "AMS B Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "030092000001000A", "intro": "The temperature of chamber heater 2 is abnormal. The AC board may be broken." }, { "ecode": "0704110000010001", "intro": "The AMS E slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0705200000020019", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1803560000030001", "intro": "AMS-HT D is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0703220000020004", "intro": "AMS D Slot 3 filament may be broken in the tool head." }, { "ecode": "0702220000010082", "intro": "Failed to read the filament information from AMS C slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1806230000020004", "intro": "AMS-HT G Slot 4 filament may be broken in the tool head." }, { "ecode": "1202210000030001", "intro": "AMS C Slot2 filament has run out. Purging the old filament; please wait." }, { "ecode": "0706700000020005", "intro": "Failed to feed the AMS G Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1801230000020019", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1201200000020001", "intro": "AMS B Slot1 filament has run out; please insert a new filament." }, { "ecode": "0300330000010001", "intro": "The Chamber Exhaust Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "0701230000020017", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "180420000002000A", "intro": "Failed to adjust the filament position of AMS-HT E Slot 1. The filament or buffer may be stuck." }, { "ecode": "1803230000020017", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1804130000010001", "intro": "The AMS-HT E slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1200120000020002", "intro": "The AMS A Slot3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800240000020009", "intro": "AMS-HT A front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "1800200000020018", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703230000020023", "intro": "AMS D slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0300D00000010003", "intro": "The cutting module cable has come loose; please check the cable connection." }, { "ecode": "0705810000010003", "intro": "AMS F The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1801710000020004", "intro": "Failed to pull back the AMS-HT B Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1202310000030003", "intro": "AMS C Slot2 RFID cannot be read because of a structural error." }, { "ecode": "1802910000020001", "intro": "AMS-HT C The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1807230000020010", "intro": "AMS-HT H slot 4 feeds filament out of AMS timeout." }, { "ecode": "0700020000020002", "intro": "AMS A The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0702810000010001", "intro": "AMS C The current sensor of heater 2 is abnormal." }, { "ecode": "1801010000020009", "intro": "AMS-HT B The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0706130000020002", "intro": "The AMS G slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805220000020014", "intro": "AMS-HT F slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0C00030000020001", "intro": "Filament exposure metering failed because laser reflection is too weak on this material. First layer inspection may be inaccurate." }, { "ecode": "0706810000010003", "intro": "AMS G The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0700200000020015", "intro": "AMS A slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1807120000010003", "intro": "The AMS-HT H slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701900000010002", "intro": "AMS B The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "070521000002000A", "intro": "Failed to adjust the filament position of AMS F Slot 2. The filament or buffer may be stuck." }, { "ecode": "1804200000020021", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1803220000020002", "intro": "AMS-HT D Slot 3 is empty; please insert a new filament." }, { "ecode": "0702130000010001", "intro": "The AMS C slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1805210000030001", "intro": "AMS-HT F Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0704230000020018", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1801220000020022", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0700010000020006", "intro": "AMS A The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1202830000020001", "intro": "AMS C Slot4 filament may be tangled or stuck." }, { "ecode": "0701210000020013", "intro": "AMS B slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701210000020022", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1805620000020001", "intro": "The AMS-HT F Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1807960000010001", "intro": "AMS-HT H The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0701220000020021", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1806230000020016", "intro": "AMS-HT G slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0703220000010081", "intro": "Failed to read the filament information from AMS D slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0701330000020002", "intro": "The RFID-tag on AMS B Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0701220000020001", "intro": "AMS B Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1806210000020020", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "03001B0000010003", "intro": "The heatbed acceleration sensor detected unexpected continuous force. The sensor may be stuck, or the analog front end may be broken." }, { "ecode": "1802230000010084", "intro": "Failed to read the filament information from AMS-HT C slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1801010000020008", "intro": "AMS-HT B The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1802220000020001", "intro": "AMS-HT C Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1803230000020022", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0705230000020018", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1802800000010003", "intro": "AMS-HT C The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0705930000010001", "intro": "AMS F The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0703960000020002", "intro": "AMS D Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0707200000020019", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700300000010004", "intro": "Encryption chip failure" }, { "ecode": "030001000001000E", "intro": "The power supply voltage does not match the machine; the heatbed has been disabled." }, { "ecode": "1807900000020001", "intro": "AMS-HT H The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1801100000010003", "intro": "The AMS-HT B slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1806910000010002", "intro": "AMS-HT G The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1201210000030002", "intro": "AMS B Slot2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1803220000020007", "intro": "AMS-HT D Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1800220000020004", "intro": "AMS-HT A Slot 3 filament may be broken in the tool head." }, { "ecode": "0702220000020023", "intro": "AMS C slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0701900000020001", "intro": "AMS B The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1201130000010003", "intro": "The AMS B Slot4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0707210000010081", "intro": "Failed to read the filament information from AMS H slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1800800000010004", "intro": "AMS-HT A The heater 1 is heating abnormally." }, { "ecode": "1805110000020004", "intro": "AMS-HT F The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704710000020001", "intro": "Failed to pull out the AMS E Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0C00030000010009", "intro": "The first layer inspection module rebooted abnormally. The inspection result may be inaccurate." }, { "ecode": "070220000002000A", "intro": "Failed to adjust the filament position of AMS C Slot 1. The filament or buffer may be stuck." }, { "ecode": "0707250000020001", "intro": "AMS H uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0703010000020006", "intro": "AMS D The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0700220000010085", "intro": "Failed to read the filament information from AMS A slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0707220000010084", "intro": "Failed to read the filament information from AMS H slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0703200000020021", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "030001000001000D", "intro": "An abnormality occured in heating modules of heatbed previously. To continue using your printer, please refer to the wiki to troubleshoot." }, { "ecode": "0706220000030002", "intro": "AMS G Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702700000020001", "intro": "Failed to pull out the AMS C Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1807200000020020", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1801700000020002", "intro": "Failed to feed the AMS-HT B Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0300260000010007", "intro": "The frequency of the extrusion force sensor of the left extruder is too high. The sensor may be installed too close, or the sensor may be loose." }, { "ecode": "03000B0000010004", "intro": "An external disturbance was detected on force sensor 2. The heatbed plate may have touched something outside the heatbed." }, { "ecode": "1804230000010086", "intro": "Failed to read the filament information from AMS-HT E slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0300010000030008", "intro": "The temperature of the heated bed exceeds the limit and automatically adjusts to the limit temperature." }, { "ecode": "1801230000020011", "intro": "AMS-HT B slot 4 pulls filament back to AMS timeout." }, { "ecode": "1806210000020024", "intro": "AMS-HT G slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0707100000010003", "intro": "The AMS H slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700210000010081", "intro": "Failed to read the filament information from AMS A slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1801700000020004", "intro": "Failed to pull back the AMS-HT B Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0705900000010002", "intro": "AMS F The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1805720000020005", "intro": "Failed to feed the AMS-HT F Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1802120000010003", "intro": "The AMS-HT C slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "070621000002000A", "intro": "Failed to adjust the filament position of AMS G Slot 2. The filament or buffer may be stuck." }, { "ecode": "0700350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1806110000020002", "intro": "The AMS-HT G slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800010000020010", "intro": "AMS-HT A The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0700970000030001", "intro": "AMS A chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1802220000030001", "intro": "AMS-HT C Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1801130000020002", "intro": "The AMS-HT B slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0701230000020023", "intro": "AMS B slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1801800000010001", "intro": "AMS-HT B The current sensor of heater 1 is abnormal." }, { "ecode": "0705730000020002", "intro": "Failed to feed the AMS F Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702200000020007", "intro": "AMS C Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0700900000020001", "intro": "AMS A The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1201110000010003", "intro": "The AMS B Slot2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0500040000020015", "intro": "The RFID-tag on AMS B Slot2 cannot be identified." }, { "ecode": "1807710000020001", "intro": "Failed to pull out the AMS-HT H Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1801230000020018", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "07FE810000010003", "intro": "The hall signal of the Extruder Switching Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "0300290000010001", "intro": "Vision encoder patterns can not be recognized; possible reasons include vision encoder pattern distortion, light overexposure, and plate misplacement." }, { "ecode": "1805970000030001", "intro": "AMS-HT F chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1802310000010001", "intro": "The AMS-HT C RFID 2 board has an error." }, { "ecode": "0706300000010001", "intro": "The AMS G RFID 1 board has an error." }, { "ecode": "0705230000020016", "intro": "AMS F slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807550000010003", "intro": "AMS-HT H was detected offline during the AMS initialization process." }, { "ecode": "0705960000010003", "intro": "AMS F Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0707220000020002", "intro": "AMS H Slot 3 is empty; please insert a new filament." }, { "ecode": "0702010000020007", "intro": "AMS C The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1807200000020013", "intro": "AMS-HT H slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800230000020004", "intro": "AMS-HT A Slot 4 filament may be broken in the tool head." }, { "ecode": "0707120000010001", "intro": "The AMS H slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0700200000020013", "intro": "AMS A slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0500010000030004", "intro": "Not enough space on the USB flash drive; please clear some space." }, { "ecode": "1803220000020018", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804230000020011", "intro": "AMS-HT E slot 4 pulls filament back to AMS timeout." }, { "ecode": "1802630000020001", "intro": "The AMS-HT C Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0700210000020018", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804220000020001", "intro": "AMS-HT E Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0707220000020020", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "03000C0000010001", "intro": "Heatbed force sensor 3 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight." }, { "ecode": "0704720000020004", "intro": "Failed to pull back the AMS E Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804120000010001", "intro": "The AMS-HT E slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1807220000010081", "intro": "Failed to read the filament information from AMS-HT H slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1805200000010083", "intro": "Failed to read the filament information from AMS-HT F slot 1. The RFID tag may be damaged." }, { "ecode": "0707710000020002", "intro": "Failed to feed the AMS H Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1202130000020002", "intro": "The AMS C Slot4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1804310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1202310000020002", "intro": "The RFID-tag on AMS C Slot 2 is damaged." }, { "ecode": "180621000002000A", "intro": "Failed to adjust the filament position of AMS-HT G Slot 2. The filament or buffer may be stuck." }, { "ecode": "0702230000020002", "intro": "AMS C Slot 4 is empty; please insert a new filament." }, { "ecode": "03000C0000010003", "intro": "The signal of heatbed force sensor 3 is too weak. The electronic connection to the sensor may be broken." }, { "ecode": "0700210000020010", "intro": "AMS A slot 2 feeds filament out of AMS timeout." }, { "ecode": "1802220000020004", "intro": "AMS-HT C Slot 3 filament may be broken in the tool head." }, { "ecode": "0706550000010003", "intro": "AMS G was detected offline during the AMS initialization process." }, { "ecode": "0707220000020001", "intro": "AMS H Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0703960000010003", "intro": "AMS D Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "03000C0000010005", "intro": "Force sensor 3 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken." }, { "ecode": "1802200000020011", "intro": "AMS-HT C slot 1 pulls filament back to AMS timeout." }, { "ecode": "1804310000010001", "intro": "The AMS-HT E RFID 2 board has an error." }, { "ecode": "1203230000020005", "intro": "AMS D Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0706200000020017", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0500040000010002", "intro": "Failed to report print state; please check your network connection." }, { "ecode": "1801200000030001", "intro": "AMS-HT B Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0C00030000020005", "intro": "First layer inspection timed out abnormally, and the current results may be inaccurate." }, { "ecode": "1803210000020004", "intro": "AMS-HT D Slot 2 filament may be broken in the tool head." }, { "ecode": "1806730000020001", "intro": "Failed to pull out the AMS-HT G Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0705130000010001", "intro": "The AMS F slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707200000020001", "intro": "AMS H Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1805230000020021", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1805220000020009", "intro": "Failed to extrude AMS-HT F Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0700230000020005", "intro": "AMS A Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0706210000020008", "intro": "AMS G Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700610000020001", "intro": "The AMS A Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "07FE810000010001", "intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose." }, { "ecode": "0702230000020011", "intro": "AMS C slot 4 pulls filament back to AMS timeout." }, { "ecode": "1805230000020020", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0707230000020001", "intro": "AMS H Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1804950000010001", "intro": "AMS-HT E The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0705810000010001", "intro": "AMS F The current sensor of heater 2 is abnormal." }, { "ecode": "0300040000020001", "intro": "The speed of the part cooling fan is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "0300280000010001", "intro": "The data of the force sensor of the Cutting Module is abnormal. The magnet on the Tool Holder may fall off or the force sensor may be damaged." }, { "ecode": "0706210000020012", "intro": "AMS G slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1804230000020005", "intro": "AMS-HT E Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704210000020018", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1802900000010002", "intro": "AMS-HT C The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1201200000020003", "intro": "AMS B Slot1 filament may be broken in the PTFE tube." }, { "ecode": "0706910000020001", "intro": "AMS G The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0707200000020012", "intro": "AMS H slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1804230000020001", "intro": "AMS-HT E Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0706230000020022", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1807350000010002", "intro": "AMS-HT H The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1803120000020002", "intro": "The AMS-HT D slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705200000030001", "intro": "AMS F Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1203110000010001", "intro": "The AMS D Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1800110000010003", "intro": "The AMS-HT A slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706700000020002", "intro": "Failed to feed the AMS G Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701010000010005", "intro": "AMS B The current sensor of assist motor may be faulty." }, { "ecode": "0500040000020014", "intro": "The RFID-tag on AMS B Slot1 cannot be identified." }, { "ecode": "1805210000020011", "intro": "AMS-HT F slot 2 pulls filament back to AMS timeout." }, { "ecode": "0707200000020005", "intro": "AMS H Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704220000010081", "intro": "Failed to read the filament information from AMS E slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1804720000020002", "intro": "Failed to feed the AMS-HT E Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1202230000030001", "intro": "AMS C Slot4 filament has run out. Purging the old filament; please wait." }, { "ecode": "1800220000020001", "intro": "AMS-HT A Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1800200000020020", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0703120000010003", "intro": "The AMS D slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700200000020002", "intro": "AMS A Slot 1 is empty; please insert a new filament." }, { "ecode": "1800210000020013", "intro": "AMS-HT A slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803010000020010", "intro": "AMS-HT D The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1803730000020005", "intro": "Failed to feed the AMS-HT D Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1805010000020007", "intro": "AMS-HT F The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0C0003000002000C", "intro": "The build plate localization marker was not detected. Please check if the build plate is aligned correctly." }, { "ecode": "0500060000020014", "intro": "" }, { "ecode": "1802220000010082", "intro": "Failed to read the filament information from AMS-HT C slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1807010000010003", "intro": "The AMS-HT H assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701720000020001", "intro": "Failed to pull out the AMS B Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802920000010001", "intro": "AMS-HT C The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "030025000001000A", "intro": "Nozzle offset calibration failed. Filament sticks to the nozzle, which may affect print quality. Please clean the nozzle and try again." }, { "ecode": "1802200000020010", "intro": "AMS-HT C slot 1 feeds filament out of AMS timeout." }, { "ecode": "1801210000010085", "intro": "Failed to read the filament information from AMS-HT B slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0300010000010003", "intro": "The heatbed temperature is abnormal; the heater is over temperature." }, { "ecode": "0300970000010002", "intro": "The top cover Hall sensor (Front Right) is abnormal; please check whether the connection wire is loose." }, { "ecode": "1802560000030001", "intro": "AMS-HT C is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "1800010000010001", "intro": "The AMS-HT A assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "1804230000020007", "intro": "AMS-HT E Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1804220000030001", "intro": "AMS-HT E Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0704200000010083", "intro": "Failed to read the filament information from AMS E slot 1. The RFID tag may be damaged." }, { "ecode": "0701210000010082", "intro": "Failed to read the filament information from AMS B slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805230000020010", "intro": "AMS-HT F slot 4 feeds filament out of AMS timeout." }, { "ecode": "1802230000020015", "intro": "AMS-HT C slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1803230000020011", "intro": "AMS-HT D slot 4 pulls filament back to AMS timeout." }, { "ecode": "07FE810000020001", "intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead." }, { "ecode": "0707220000020009", "intro": "Failed to extrude AMS H Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0705010000020007", "intro": "AMS F The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1201220000020003", "intro": "AMS B Slot3 filament may be broken in the PTFE tube." }, { "ecode": "1200210000020002", "intro": "AMS A Slot 2 is empty; please insert a new filament." }, { "ecode": "1800220000030002", "intro": "AMS-HT A Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806220000020014", "intro": "AMS-HT G slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0707210000020005", "intro": "AMS H Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1800230000020008", "intro": "AMS-HT A Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704220000020017", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0707310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1800400000020003", "intro": "The AMS Hub communication is abnormal; the cable may be not well connected." }, { "ecode": "0705210000020018", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1801240000020009", "intro": "AMS-HT B front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "1807010000010005", "intro": "AMS-HT H The current sensor of assist motor may be faulty." }, { "ecode": "0702220000030002", "intro": "AMS C Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700720000020002", "intro": "Failed to feed the AMS A Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703010000020007", "intro": "AMS D The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0500040000010052", "intro": "Safety Key is not inserted. Please follow the Wiki to install it." }, { "ecode": "0701200000030001", "intro": "AMS B Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800220000020005", "intro": "AMS-HT A Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0706700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1805210000020002", "intro": "AMS-HT F Slot 2 is empty; please insert a new filament." }, { "ecode": "0701900000010003", "intro": "AMS B The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0702210000020009", "intro": "Failed to extrude AMS C Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807200000020008", "intro": "AMS-HT H Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1806230000020018", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0705130000020004", "intro": "AMS F The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0500040000020035", "intro": "The Laser Module needs calibration to get the focus position. Please perform mounting calibration before use. (about 2 minutes)" }, { "ecode": "0702110000010001", "intro": "The AMS C slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "18FF800000010004", "intro": "The Toolhead Lifting Motor position hall sensor is short-circuited; please check if the Hall sensor is malfunctioning." }, { "ecode": "18FE800000010006", "intro": "The TH board disconnected during the extruder switching process. Please check if the connecting cable is loose." }, { "ecode": "1806230000010084", "intro": "Failed to read the filament information from AMS-HT G slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1807210000020016", "intro": "AMS-HT H slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1806210000020013", "intro": "AMS-HT G slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703970000030001", "intro": "AMS D chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0500020000020008", "intro": "Time synchronization failed" }, { "ecode": "1803220000020013", "intro": "AMS-HT D slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703200000020006", "intro": "AMS D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1804100000010001", "intro": "The AMS-HT E slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0C00010000020007", "intro": "Micro Lidar laser parameters have drifted. Please re-calibrate your printer." }, { "ecode": "050004000001004F", "intro": "Unknown module detected, please try updating the firmware to the latest version." }, { "ecode": "1200300000030003", "intro": "AMS A Slot1 RFID cannot be read because of a structural error." }, { "ecode": "0703020000020002", "intro": "AMS D The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0701110000020004", "intro": "AMS B The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700220000030001", "intro": "AMS A Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1802800000010004", "intro": "AMS-HT C The heater 1 is heating abnormally." }, { "ecode": "1805220000020010", "intro": "AMS-HT F slot 3 feeds filament out of AMS timeout." }, { "ecode": "0705210000020024", "intro": "AMS F slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1805210000020015", "intro": "AMS-HT F slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "18FF600000020001", "intro": "External spool connected to right extruder may be tangled or jammed." }, { "ecode": "0701230000020020", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0704020000010001", "intro": "AMS E Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0704200000010085", "intro": "Failed to read the filament information from AMS E slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1801960000020002", "intro": "AMS-HT B Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1807230000010086", "intro": "Failed to read the filament information from AMS-HT H slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0702350000010002", "intro": "AMS C The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700330000020002", "intro": "The RFID-tag on AMS A Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1805220000010086", "intro": "Failed to read the filament information from AMS-HT F slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1802700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1806210000030002", "intro": "AMS-HT G Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1802240000010007", "intro": "AMS-HT C door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0300C00000010003", "intro": "Automatic Top Vent air door malfunction: it may be stuck." }, { "ecode": "0707230000030001", "intro": "AMS H Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1802220000020017", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0701210000020004", "intro": "AMS B Slot 2 filament may be broken in the tool head." }, { "ecode": "0700130000020004", "intro": "AMS A The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702220000020015", "intro": "AMS C slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1803200000020008", "intro": "AMS-HT D Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "07FE800000010004", "intro": "The Toolhead Lifting Motor position hall sensor is short-circuited; please check if the Hall sensor is malfunctioning." }, { "ecode": "1200130000020002", "intro": "The AMS A Slot4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1806010000010001", "intro": "The AMS-HT G assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0500030000020010", "intro": "" }, { "ecode": "0500030000010002", "intro": "The toolhead is malfunctioning. Please restart the device." }, { "ecode": "1803220000020012", "intro": "AMS-HT D slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0C00040000020018", "intro": "The Cutting Blade offset calibration failed. This may affect the cutting accuracy. Please refer to the Assistant to check if the blade tip is worn." }, { "ecode": "0704220000020001", "intro": "AMS E Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1803960000010001", "intro": "AMS-HT D The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "1804210000020019", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0300940000030001", "intro": "Chamber cooling may be too slow. You can open the front door or top cover to help cooling if the air in the chamber is non-toxic." }, { "ecode": "1201300000020002", "intro": "The RFID-tag on AMS B Slot 1 is damaged." }, { "ecode": "1806720000020002", "intro": "Failed to feed the AMS-HT G Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1807310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0704010000020011", "intro": "AMS E The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1807200000010083", "intro": "Failed to read the filament information from AMS-HT H slot 1. The RFID tag may be damaged." }, { "ecode": "18FE800000010003", "intro": "The hall signal of the Toolhead Lifting Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "0706100000020004", "intro": "AMS G The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804230000010082", "intro": "Failed to read the filament information from AMS-HT E slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1806200000010086", "intro": "Failed to read the filament information from AMS-HT G slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0700200000020003", "intro": "AMS A Slot 1's filament may be broken in AMS." }, { "ecode": "0707010000010005", "intro": "AMS H The current sensor of assist motor may be faulty." }, { "ecode": "0707600000020001", "intro": "The AMS H Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806200000020021", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0500030000020014", "intro": "" }, { "ecode": "1807230000020005", "intro": "AMS-HT H Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704200000030002", "intro": "AMS E Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1805230000020002", "intro": "AMS-HT F Slot 4 is empty; please insert a new filament." }, { "ecode": "0704230000010086", "intro": "Failed to read the filament information from AMS E slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "07FF450000020003", "intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection." }, { "ecode": "1804700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0706200000020010", "intro": "AMS G slot 1 feeds filament out of AMS timeout." }, { "ecode": "1803220000010084", "intro": "Failed to read the filament information from AMS-HT D slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0704230000020001", "intro": "AMS E Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1807210000020022", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0300070000010001", "intro": "Motor-B has an open-circuit. The connection may be loose, or the motor may have failed." }, { "ecode": "1807230000020022", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0703200000010084", "intro": "Failed to read the filament information from AMS D slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0701350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0707800000010004", "intro": "AMS H The heater 1 is heating abnormally." }, { "ecode": "0704210000020004", "intro": "AMS E Slot 2 filament may be broken in the tool head." }, { "ecode": "0701200000020012", "intro": "AMS B slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0700210000020003", "intro": "AMS A Slot 2's filament may be broken in AMS." }, { "ecode": "1807720000020002", "intro": "Failed to feed the AMS-HT H Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1802010000010004", "intro": "The AMS-HT C assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1805200000010082", "intro": "Failed to read the filament information from AMS-HT F slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805200000020001", "intro": "AMS-HT F Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0300C30000010001", "intro": "Current sensor of Active Chamber Exhaust malfunction: this may be due to an open circuit or a hardware sampling circuit fault." }, { "ecode": "1801120000020002", "intro": "The AMS-HT B slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705230000010081", "intro": "Failed to read the filament information from AMS F slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1803940000010001", "intro": "AMS-HT D The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0701210000020007", "intro": "AMS B Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1807230000020016", "intro": "AMS-HT H slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0300990000010002", "intro": "The right side window Hall sensor (Lower) is abnormal; please check whether the connection wire is loose." }, { "ecode": "0706220000020011", "intro": "AMS G slot 3 pulls filament back to AMS timeout." }, { "ecode": "1802210000020008", "intro": "AMS-HT C Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700200000020004", "intro": "AMS A Slot 1 filament may be broken in the tool head." }, { "ecode": "1201300000010004", "intro": "RFID cannot be read because of an encryption chip failure in AMS B." }, { "ecode": "0700220000020022", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0704220000020021", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1805210000020023", "intro": "AMS-HT F slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0702220000010083", "intro": "Failed to read the filament information from AMS C slot 3. The RFID tag may be damaged." }, { "ecode": "1804230000010084", "intro": "Failed to read the filament information from AMS-HT E slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1804010000020007", "intro": "AMS-HT E The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0704220000010082", "intro": "Failed to read the filament information from AMS E slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0700220000010086", "intro": "Failed to read the filament information from AMS A slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0700550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0707700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1804230000020012", "intro": "AMS-HT E slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704010000010011", "intro": "AMS E The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0300990000010001", "intro": "The right side window seems to be open; the task has been paused." }, { "ecode": "0703220000010084", "intro": "Failed to read the filament information from AMS D slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1802710000020002", "intro": "Failed to feed the AMS-HT C Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805210000010085", "intro": "Failed to read the filament information from AMS-HT F slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0C0003000001000A", "intro": "Your printer is in factory mode. Please contact Technical Support." }, { "ecode": "0703100000010001", "intro": "The AMS D slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1802730000020004", "intro": "Failed to pull back the AMS-HT C Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805220000020018", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1800200000010084", "intro": "Failed to read the filament information from AMS-HT A slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1202230000020004", "intro": "AMS C Slot4 filament may be broken in the tool head." }, { "ecode": "0300A40000010004", "intro": "Chamber temperature is too high. Please wait for it to cool down to room temperature before restarting the task." }, { "ecode": "0C00010000010018", "intro": "" }, { "ecode": "1806210000020011", "intro": "AMS-HT G slot 2 pulls filament back to AMS timeout." }, { "ecode": "0701220000020022", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1801220000020023", "intro": "AMS-HT B slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1801200000030002", "intro": "AMS-HT B Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806710000020004", "intro": "Failed to pull back the AMS-HT G Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700230000010081", "intro": "Failed to read the filament information from AMS A slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0706920000020002", "intro": "AMS G The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0705010000020011", "intro": "AMS F The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1200220000020002", "intro": "AMS A Slot 3 is empty; please insert a new filament." }, { "ecode": "1800230000020005", "intro": "AMS-HT A Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "03000C0000010002", "intro": "The signal of heatbed force sensor 3 is weak. The force sensor may be broken or have poor electric connection." }, { "ecode": "0500060000020042", "intro": "" }, { "ecode": "0706010000020011", "intro": "AMS G The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1807240000010007", "intro": "AMS-HT H door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0704700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "070323000002000A", "intro": "Failed to adjust the filament position of AMS D Slot 4. The filament or buffer may be stuck." }, { "ecode": "1800220000020002", "intro": "AMS-HT A Slot 3 is empty; please insert a new filament." }, { "ecode": "1801200000010086", "intro": "Failed to read the filament information from AMS-HT B slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "070721000002000A", "intro": "Failed to adjust the filament position of AMS H Slot 2. The filament or buffer may be stuck." }, { "ecode": "0704700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0701700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1800800000010003", "intro": "AMS-HT A The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0705910000010003", "intro": "AMS F The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1807310000020002", "intro": "The RFID-tag on AMS-HT H Slot2 is damaged, or its content cannot be identified." }, { "ecode": "1804210000030001", "intro": "AMS-HT E Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1804210000020020", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1807320000020002", "intro": "The RFID-tag on AMS-HT H Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1803610000020001", "intro": "The AMS-HT D Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806220000020012", "intro": "AMS-HT G slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1805730000020005", "intro": "Failed to feed the AMS-HT F Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1200120000010003", "intro": "The AMS A Slot3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1202210000020006", "intro": "Failed to extrude AMS C Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1802960000010001", "intro": "AMS-HT C The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0703110000010003", "intro": "The AMS D slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1802210000020024", "intro": "AMS-HT C slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0701230000020009", "intro": "Failed to extrude AMS B Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707220000020016", "intro": "AMS H slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0705550000010003", "intro": "AMS F was detected offline during the AMS initialization process." }, { "ecode": "0701210000020012", "intro": "AMS B slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1801210000020013", "intro": "AMS-HT B slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802970000030001", "intro": "AMS-HT C chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0707220000010082", "intro": "Failed to read the filament information from AMS H slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805500000020001", "intro": "AMS-HT F communication is abnormal; please check the connection cable." }, { "ecode": "0501050000010010", "intro": "The firmware of AMS B does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0703700000020005", "intro": "Failed to feed the AMS D Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0703810000010001", "intro": "AMS D The current sensor of heater 2 is abnormal." }, { "ecode": "1806810000010001", "intro": "AMS-HT G The current sensor of heater 2 is abnormal." }, { "ecode": "0700450000020002", "intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps." }, { "ecode": "1805800000010002", "intro": "AMS-HT F The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0702220000010084", "intro": "Failed to read the filament information from AMS C slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706220000010086", "intro": "Failed to read the filament information from AMS G slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1200450000020003", "intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection." }, { "ecode": "0707120000020002", "intro": "The AMS H slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1203230000030001", "intro": "AMS D Slot4 filament has run out. Purging the old filament; please wait." }, { "ecode": "0C00030000020002", "intro": "First layer inspection terminated due to abnormal Lidar data." }, { "ecode": "0705210000020015", "intro": "AMS F slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0706200000010083", "intro": "Failed to read the filament information from AMS G slot 1. The RFID tag may be damaged." }, { "ecode": "0705210000020005", "intro": "AMS F Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1805960000010001", "intro": "AMS-HT F The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0700730000020002", "intro": "Failed to feed the AMS A Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803200000020017", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1805230000020023", "intro": "AMS-HT F slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1200230000020003", "intro": "AMS A Slot4 filament may be broken in the PTFE tube." }, { "ecode": "1803200000020013", "intro": "AMS-HT D slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707810000010002", "intro": "AMS H The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0707730000020005", "intro": "Failed to feed the AMS H Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0702210000020020", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0700400000020003", "intro": "The AMS Hub communication is abnormal; the cable may be not well connected." }, { "ecode": "1800230000020020", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706210000010086", "intro": "Failed to read the filament information from AMS G slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0705500000020001", "intro": "AMS F communication is abnormal; please check the connection cable." }, { "ecode": "1802230000020018", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1802220000020020", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0705230000010084", "intro": "Failed to read the filament information from AMS F slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0C00030000020017", "intro": "Laser engraving Z-axis focus calibration failed. Please check if the Laser Test Material (350g paperboard) is properly placed and its surface is clean and intact." }, { "ecode": "18FE800000020003", "intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate." }, { "ecode": "1807960000020002", "intro": "AMS-HT H Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1203120000010003", "intro": "The AMS D Slot3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1802310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "07FE810000010004", "intro": "The position hall sensor of the Extruder Switching Motor has a short circuit; please check if the Hall sensor is malfunctioning." }, { "ecode": "0706610000020001", "intro": "The AMS G Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300050000010001", "intro": "The motor driver is overheating. Its radiator may be loose, or its cooling fan may be damaged." }, { "ecode": "1806230000020022", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1800920000010001", "intro": "AMS-HT A The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "18FF800000010001", "intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose." }, { "ecode": "1807120000020002", "intro": "The AMS-HT H slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1201130000010001", "intro": "The AMS B Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0703200000020002", "intro": "AMS D Slot 1 is empty; please insert a new filament." }, { "ecode": "0700700000020002", "intro": "Failed to feed the AMS A Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804320000020002", "intro": "The RFID-tag on AMS-HT E Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0700220000020005", "intro": "AMS A Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0703200000020003", "intro": "AMS D Slot 1's filament may be broken in AMS." }, { "ecode": "1800630000020001", "intro": "The AMS-HT A Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0700220000020018", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0700210000010082", "intro": "Failed to read the filament information from AMS A slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0705210000020014", "intro": "AMS F slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1806010000020011", "intro": "AMS-HT G The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0706220000020017", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1200300000010004", "intro": "RFID cannot be read because of an encryption chip failure in AMS A." }, { "ecode": "0702230000020016", "intro": "AMS C slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1806900000010003", "intro": "AMS-HT G The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "1200510000030001", "intro": "AMS is disabled; please load filament from spool holder." }, { "ecode": "0707010000010004", "intro": "The AMS H assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1807230000020024", "intro": "AMS-HT H slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0500030000010006", "intro": "A system panic occurred. Please restart the device." }, { "ecode": "1800230000020007", "intro": "AMS-HT A Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705960000010001", "intro": "AMS F The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0500030000030007", "intro": "" }, { "ecode": "1804200000010081", "intro": "Failed to read the filament information from AMS-HT E slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1802730000020005", "intro": "Failed to feed the AMS-HT C Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0500050000010011", "intro": "The Air Pump firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1805010000010004", "intro": "The AMS-HT F assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1802220000020005", "intro": "AMS-HT C Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0707220000020013", "intro": "AMS H slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0706500000020001", "intro": "AMS G communication is abnormal; please check the connection cable." }, { "ecode": "1803100000020004", "intro": "AMS-HT D The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802010000020007", "intro": "AMS-HT C The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0702610000020001", "intro": "The AMS C Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300A10000010001", "intro": "Chamber temperature is too high. Please open the top cover and front door to cool down, or lower the ambient temperature." }, { "ecode": "0703310000020002", "intro": "The RFID-tag on AMS D Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0702200000010083", "intro": "Failed to read the filament information from AMS C slot 1. The RFID tag may be damaged." }, { "ecode": "1803230000020020", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1807230000020019", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0701810000010002", "intro": "AMS B The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0702210000020021", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0702130000010003", "intro": "The AMS C slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701200000020004", "intro": "AMS B Slot 1 filament may be broken in the tool head." }, { "ecode": "0706200000020022", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1803920000020002", "intro": "AMS-HT D The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0706200000020019", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0701700000020002", "intro": "Failed to feed the AMS B Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800220000020023", "intro": "AMS-HT A slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1806230000020020", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0702500000020001", "intro": "AMS C communication is abnormal; please check the connection cable." }, { "ecode": "0C00040000020003", "intro": "The Laser Platform is not properly aligned. Please ensure all four corners are aligned with the heatbed." }, { "ecode": "0300900000010010", "intro": "The communication of chamber temperature controller is abnormal." }, { "ecode": "0707200000020014", "intro": "AMS H slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1804220000020021", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0703350000010002", "intro": "AMS D The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800810000010002", "intro": "AMS-HT A The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1807230000020003", "intro": "AMS-HT H Slot 4's filament may be broken in AMS-HT." }, { "ecode": "0703230000020015", "intro": "AMS D slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1807200000030002", "intro": "AMS-HT H Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702900000020001", "intro": "AMS C The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "0706010000010011", "intro": "AMS G The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "18FE810000010001", "intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose." }, { "ecode": "1803710000020002", "intro": "Failed to feed the AMS-HT D Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703200000020004", "intro": "AMS D Slot 1 filament may be broken in the tool head." }, { "ecode": "07FEA00000020001", "intro": "The left nozzle cold pull process has timed out. Please click \"Retry\" and then manually pull out the filament." }, { "ecode": "1806700000020005", "intro": "Failed to feed the AMS-HT G Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1806120000020002", "intro": "The AMS-HT G slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0703220000010082", "intro": "Failed to read the filament information from AMS D slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "070420000002000A", "intro": "Failed to adjust the filament position of AMS E Slot 1. The filament or buffer may be stuck." }, { "ecode": "0707810000010001", "intro": "AMS H The current sensor of heater 2 is abnormal." }, { "ecode": "1803230000020004", "intro": "AMS-HT D Slot 4 filament may be broken in the tool head." }, { "ecode": "0500030000010026", "intro": "The Toolhead expansion module is malfunctioning. Please power off, check the connection, and restart the device." }, { "ecode": "0700230000020007", "intro": "AMS A Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1203200000020004", "intro": "AMS D Slot1 filament may be broken in the tool head." }, { "ecode": "1201700000010001", "intro": "AMS B Filament speed and length error: The slot 1 filament odometry may be faulty." }, { "ecode": "0500040000020041", "intro": "The laser module has been used for a long time. Please clean it promptly to avoid affecting laser processing." }, { "ecode": "1804210000020013", "intro": "AMS-HT E slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804110000010001", "intro": "The AMS-HT E slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1805010000020008", "intro": "AMS-HT F The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "0702220000020002", "intro": "AMS C Slot 3 is empty; please insert a new filament." }, { "ecode": "0705810000010002", "intro": "AMS F The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1806720000020001", "intro": "Failed to pull out the AMS-HT G Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1801210000010084", "intro": "Failed to read the filament information from AMS-HT B slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0703220000010083", "intro": "Failed to read the filament information from AMS D slot 3. The RFID tag may be damaged." }, { "ecode": "0704700000020002", "intro": "Failed to feed the AMS E Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805210000020004", "intro": "AMS-HT F Slot 2 filament may be broken in the tool head." }, { "ecode": "1805200000020017", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0702210000010086", "intro": "Failed to read the filament information from AMS C slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0704200000020001", "intro": "AMS E Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0702220000020021", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0700300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1202130000010001", "intro": "The AMS C Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1803200000020019", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0703230000020024", "intro": "AMS D slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0705200000020002", "intro": "AMS F Slot 1 is empty; please insert a new filament." }, { "ecode": "0300950000010003", "intro": "Laser Module overheating" }, { "ecode": "0707330000020002", "intro": "The RFID-tag on AMS H Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1801200000020012", "intro": "AMS-HT B slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1802220000020024", "intro": "AMS-HT C slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0700220000020007", "intro": "AMS A Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1804220000020019", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706220000020002", "intro": "AMS G Slot 3 is empty; please insert a new filament." }, { "ecode": "1802900000020001", "intro": "AMS-HT C The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1804010000020010", "intro": "AMS-HT E The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0702230000010082", "intro": "Failed to read the filament information from AMS C slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0C00030000020012", "intro": "Foreign object detection is not working. The Live View Camera needs calibration. Please tap \"Settings > Calibration\" on the printer screen. If a laser or cutting module is installed, please remove it before calibration." }, { "ecode": "0702200000020013", "intro": "AMS C slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1201210000020005", "intro": "AMS B Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0702210000020023", "intro": "AMS C slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1202220000030002", "intro": "AMS C Slot3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0500040000020032", "intro": "Please slide in Laser Module and lock the quick-release lever." }, { "ecode": "1800200000020004", "intro": "AMS-HT A Slot 1 filament may be broken in the tool head." }, { "ecode": "1800220000020022", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0705230000010085", "intro": "Failed to read the filament information from AMS F slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0705220000010085", "intro": "Failed to read the filament information from AMS F slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1807210000020008", "intro": "AMS-HT H Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0702700000020002", "intro": "Failed to feed the AMS C Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0704200000020011", "intro": "AMS E slot 1 pulls filament back to AMS timeout." }, { "ecode": "1805710000020001", "intro": "Failed to pull out the AMS-HT F Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0705920000020002", "intro": "AMS F The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "180620000002000A", "intro": "Failed to adjust the filament position of AMS-HT G Slot 1. The filament or buffer may be stuck." }, { "ecode": "1802810000010001", "intro": "AMS-HT C The current sensor of heater 2 is abnormal." }, { "ecode": "0707230000020004", "intro": "AMS H Slot 4 filament may be broken in the tool head." }, { "ecode": "0706220000020022", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1805810000010002", "intro": "AMS-HT F The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "07FF800000010003", "intro": "The hall signal of the Toolhead Lifting Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "1804220000030002", "intro": "AMS-HT E Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806220000020003", "intro": "AMS-HT G Slot 3's filament may be broken in AMS-HT." }, { "ecode": "0706730000020002", "intro": "Failed to feed the AMS G Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0707940000010001", "intro": "AMS H The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0702210000010082", "intro": "Failed to read the filament information from AMS C slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0704200000020012", "intro": "AMS E slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0300110000020002", "intro": "The resonance frequency of the Y-axis differs greatly from the last calibration. Please clean the Y-axis liner rod and conduct a calibration after printing." }, { "ecode": "1800970000030001", "intro": "AMS-HT A chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "030001000001000C", "intro": "The heatbed has worked at full load for a long time. The temperature control system may be abnormal." }, { "ecode": "1806200000010084", "intro": "Failed to read the filament information from AMS-HT G slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1805230000020022", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0300910000010008", "intro": "The chamber heater failed to reach the target temperature." }, { "ecode": "1803200000020004", "intro": "AMS-HT D Slot 1 filament may be broken in the tool head." }, { "ecode": "1803120000020004", "intro": "AMS-HT D The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800130000010003", "intro": "The AMS-HT A slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1202820000020001", "intro": "AMS C Slot3 filament may be tangled or stuck." }, { "ecode": "1801230000020013", "intro": "AMS-HT B slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703200000030002", "intro": "AMS D Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806220000020002", "intro": "AMS-HT G Slot 3 is empty; please insert a new filament." }, { "ecode": "1804210000010084", "intro": "Failed to read the filament information from AMS-HT E slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1800230000010084", "intro": "Failed to read the filament information from AMS-HT A slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706910000010002", "intro": "AMS G The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0300260000010003", "intro": "Unable to read data from the left extruder force sensor; there may be a communication break or sensor damage." }, { "ecode": "1800220000020012", "intro": "AMS-HT A slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704210000020007", "intro": "AMS E Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0500040000020010", "intro": "The RFID-tag on AMS A Slot1 cannot be identified." }, { "ecode": "1804200000020020", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0707100000010001", "intro": "The AMS H slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1806940000010001", "intro": "AMS-HT G The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0706220000020019", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1806210000010086", "intro": "Failed to read the filament information from AMS-HT G slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0705210000020020", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701210000010084", "intro": "Failed to read the filament information from AMS B slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0701200000020014", "intro": "AMS B slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "07FF800000010001", "intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose." }, { "ecode": "0700310000010004", "intro": "Encryption chip failure" }, { "ecode": "1805220000020023", "intro": "AMS-HT F slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0300090000020001", "intro": "The extrusion motor is overloaded. The extruder may be clogged or the filament may be stuck in the tool head." }, { "ecode": "0704350000010002", "intro": "AMS E The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700210000020007", "intro": "AMS A Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1803200000020005", "intro": "AMS-HT D Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1804200000020024", "intro": "AMS-HT E slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1201330000030003", "intro": "AMS B Slot4 RFID cannot be read because of a structural error." }, { "ecode": "0703210000020009", "intro": "Failed to extrude AMS D Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1805200000020024", "intro": "AMS-HT F slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1800300000010004", "intro": "Encryption chip failure" }, { "ecode": "1806210000020014", "intro": "AMS-HT G slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "070520000002000A", "intro": "Failed to adjust the filament position of AMS F Slot 1. The filament or buffer may be stuck." }, { "ecode": "1800210000020004", "intro": "AMS-HT A Slot 2 filament may be broken in the tool head." }, { "ecode": "07FF200000020001", "intro": "External filament of right extruder has run out; please load a new filament." }, { "ecode": "1806010000010003", "intro": "The AMS-HT G assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706210000020002", "intro": "AMS G Slot 2 is empty; please insert a new filament." }, { "ecode": "1803700000020002", "intro": "Failed to feed the AMS-HT D Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701210000020008", "intro": "AMS B Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1202220000030001", "intro": "AMS C Slot3 filament has run out. Purging the old filament; please wait." }, { "ecode": "1803200000020010", "intro": "AMS-HT D slot 1 feeds filament out of AMS timeout." }, { "ecode": "0700210000020021", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0702700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0300250000010001", "intro": "The frequency of the extrusion force sensor of the right extruder is too low. The nozzle may not be installed, or the nozzle heat sink may be too far away from the sensor." }, { "ecode": "0707130000020004", "intro": "AMS H The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700730000020005", "intro": "Failed to feed the AMS A Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1800200000030001", "intro": "AMS-HT A Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0705900000020001", "intro": "AMS F The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1807200000020009", "intro": "Failed to extrude AMS-HT H Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0706560000030001", "intro": "AMS G is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0706220000010083", "intro": "Failed to read the filament information from AMS G slot 3. The RFID tag may be damaged." }, { "ecode": "1805200000020002", "intro": "AMS-HT F Slot 1 is empty; please insert a new filament." }, { "ecode": "0700220000020021", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1800730000020005", "intro": "Failed to feed the AMS-HT A Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1804230000020016", "intro": "AMS-HT E slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0703200000020016", "intro": "AMS D slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0707230000020024", "intro": "AMS H slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1801230000020007", "intro": "AMS-HT B Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0500030000020016", "intro": "" }, { "ecode": "0703200000020005", "intro": "AMS D Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0706810000010001", "intro": "AMS G The current sensor of heater 2 is abnormal." }, { "ecode": "1801010000020011", "intro": "AMS-HT B The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0700220000020019", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0705230000020005", "intro": "AMS F Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0700220000020014", "intro": "AMS A slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1202200000020003", "intro": "AMS C Slot1 filament may be broken in the PTFE tube." }, { "ecode": "0700210000020016", "intro": "AMS A slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0702230000020013", "intro": "AMS C slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806210000020012", "intro": "AMS-HT G slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0300A40000010002", "intro": "The right hotend temperature is too high. Please wait for it to cool down to room temperature before restarting the task." }, { "ecode": "0705910000010002", "intro": "AMS F The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0705220000030002", "intro": "AMS F Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806710000020002", "intro": "Failed to feed the AMS-HT G Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803200000010085", "intro": "Failed to read the filament information from AMS-HT D slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0705230000020009", "intro": "Failed to extrude AMS F Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0701230000020005", "intro": "AMS B Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0705930000020002", "intro": "AMS F The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1804130000020004", "intro": "AMS-HT E The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703200000020024", "intro": "AMS D slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200210000030002", "intro": "AMS A Slot2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1803230000020015", "intro": "AMS-HT D slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1802960000010003", "intro": "AMS-HT C Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1802120000010001", "intro": "The AMS-HT C slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0705200000020005", "intro": "AMS F Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1201220000020004", "intro": "AMS B Slot3 filament may be broken in the tool head." }, { "ecode": "0704310000010004", "intro": "Encryption chip failure" }, { "ecode": "1801200000020013", "intro": "AMS-HT B slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701730000020004", "intro": "Failed to pull back the AMS B Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803350000010002", "intro": "AMS-HT D The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1804240000010007", "intro": "AMS-HT E door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0706130000010001", "intro": "The AMS G slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0704350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0702730000020002", "intro": "Failed to feed the AMS C Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "050005000001000F", "intro": "The accessory firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1806110000020004", "intro": "AMS-HT G The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702220000020013", "intro": "AMS C slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806220000020016", "intro": "AMS-HT G slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1801240000010007", "intro": "AMS-HT B door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0702200000020011", "intro": "AMS C slot 1 pulls filament back to AMS timeout." }, { "ecode": "0702310000010004", "intro": "Encryption chip failure" }, { "ecode": "1804200000010083", "intro": "Failed to read the filament information from AMS-HT E slot 1. The RFID tag may be damaged." }, { "ecode": "1803910000020001", "intro": "AMS-HT D The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1803230000010085", "intro": "Failed to read the filament information from AMS-HT D slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0586050000010010", "intro": "The firmware of AMS-HT G does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "18FF450000020003", "intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection." }, { "ecode": "0500060000020052", "intro": "" }, { "ecode": "0704230000020024", "intro": "AMS E slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1805700000020001", "intro": "Failed to pull out the AMS-HT F Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1807100000020002", "intro": "The AMS-HT H slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803230000020009", "intro": "Failed to extrude AMS-HT D Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1803210000030002", "intro": "AMS-HT D Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0703730000020001", "intro": "Failed to pull out the AMS D Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1805200000010084", "intro": "Failed to read the filament information from AMS-HT F slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706010000020009", "intro": "AMS G The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0C0003000002000E", "intro": "Your nozzle seems to be covered with jammed or clogged material." }, { "ecode": "0705730000020005", "intro": "Failed to feed the AMS F Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1203100000010001", "intro": "The AMS D Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0300350000010001", "intro": "The MC module cooling fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "1806200000010083", "intro": "Failed to read the filament information from AMS-HT G slot 1. The RFID tag may be damaged." }, { "ecode": "0300280000010005", "intro": "Z-axis homing failed in cutting mode. Please check if there are any foreign objects in the Z-axis slider and Z-axis synchronous pulley." }, { "ecode": "0703220000020024", "intro": "AMS D slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807910000020001", "intro": "AMS-HT H The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1800350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0704910000010003", "intro": "AMS E The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1802210000020015", "intro": "AMS-HT C slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0704920000010001", "intro": "AMS E The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "0701210000020018", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703200000010081", "intro": "Failed to read the filament information from AMS D slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1802230000010083", "intro": "Failed to read the filament information from AMS-HT C slot 4. The RFID tag may be damaged." }, { "ecode": "0705230000020014", "intro": "AMS F slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1805220000020001", "intro": "AMS-HT F Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1801110000010003", "intro": "The AMS-HT B slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1807810000010003", "intro": "AMS-HT H The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0702900000010003", "intro": "AMS C The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "1803350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0705210000010084", "intro": "Failed to read the filament information from AMS F slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1805310000010004", "intro": "Encryption chip failure" }, { "ecode": "0701710000020005", "intro": "Failed to feed the AMS B Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707200000020010", "intro": "AMS H slot 1 feeds filament out of AMS timeout." }, { "ecode": "1200320000010001", "intro": "AMS A Slot 3 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1800200000030002", "intro": "AMS-HT A Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700510000030001", "intro": "The AMS is disabled; please load filament from the spool holder." }, { "ecode": "1806240000010007", "intro": "AMS-HT G door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0702200000020006", "intro": "AMS C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0706230000020020", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0C00030000020018", "intro": "Insufficient system memory was detected, and the foreign object detection function was not working. Please restart the devices or update the firmware after the task is completed" }, { "ecode": "0500020000020002", "intro": "Device login failed; please check your account information." }, { "ecode": "0702100000020002", "intro": "The AMS C slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704100000020002", "intro": "The AMS E slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705710000020001", "intro": "Failed to pull out the AMS F Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802230000010082", "intro": "Failed to read the filament information from AMS-HT C slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0707200000020017", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705230000010083", "intro": "Failed to read the filament information from AMS F slot 4. The RFID tag may be damaged." }, { "ecode": "030091000001000E", "intro": "The power supply voltage does not match the machine; chamber heater 1 has been disabled." }, { "ecode": "0701920000010001", "intro": "AMS B The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1806100000020002", "intro": "The AMS-HT G slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803200000020009", "intro": "Failed to extrude AMS-HT D Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0705220000020023", "intro": "AMS F slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1803700000020004", "intro": "Failed to pull back the AMS-HT D Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0C00020000020004", "intro": "Nozzle height seems to be too low. Please check if the nozzle is worn or tilted. Re-calibrate Lidar if the nozzle has been replaced." }, { "ecode": "1805720000020001", "intro": "Failed to pull out the AMS-HT F Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1805010000020010", "intro": "AMS-HT F The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1201220000030001", "intro": "AMS B Slot3 filament has run out. Purging the old filament; please wait." }, { "ecode": "0700100000010003", "intro": "The AMS A slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0700010000010005", "intro": "AMS A The current sensor of assist motor may be faulty." }, { "ecode": "1807220000020013", "intro": "AMS-HT H slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804220000010086", "intro": "Failed to read the filament information from AMS-HT E slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1807200000020021", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0300280000010007", "intro": "Communication failure between the Cutting Module and toolhead module. Please check if the Cutting module signal cable is loose or broken. It could also be due to a broken force sensor coil." }, { "ecode": "0500040000020017", "intro": "The RFID-tag on AMS B Slot4 cannot be identified." }, { "ecode": "07FFA00000020001", "intro": "The right nozzle cold pull process has timed out. Please click \"Retry\" and then manually pull out the filament." }, { "ecode": "0701700000020005", "intro": "Failed to feed the AMS B Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0702200000030001", "intro": "AMS C Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0300360000020002", "intro": "The Chamber Heat Circulation Fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "1805100000020002", "intro": "The AMS-HT F slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706200000020014", "intro": "AMS G slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0707220000020014", "intro": "AMS H slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1805200000020022", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1200100000020002", "intro": "The AMS A Slot1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1804210000020021", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801560000030001", "intro": "AMS-HT B is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0703700000020004", "intro": "Failed to pull back the AMS D Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701230000020018", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "18FF200000020002", "intro": "No filament was detected in the right extruder from the external spool; please load the new filament." }, { "ecode": "1805300000020002", "intro": "The RFID-tag on AMS-HT F Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1801210000020010", "intro": "AMS-HT B slot 2 feeds filament out of AMS timeout." }, { "ecode": "0704110000020002", "intro": "The AMS E slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707200000020021", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801350000010002", "intro": "AMS-HT B The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800220000010085", "intro": "Failed to read the filament information from AMS-HT A slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1807800000010004", "intro": "AMS-HT H The heater 1 is heating abnormally." }, { "ecode": "0700810000010001", "intro": "AMS A The current sensor of heater 2 is abnormal." }, { "ecode": "1801210000010083", "intro": "Failed to read the filament information from AMS-HT B slot 2. The RFID tag may be damaged." }, { "ecode": "0707100000020002", "intro": "The AMS H slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0300900000010005", "intro": "Chamber heating failed. The thermal resistance is too high." }, { "ecode": "0705300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "05000600000200A0", "intro": "" }, { "ecode": "1803230000020016", "intro": "AMS-HT D slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807550000010004", "intro": "The binding between AMS-HT H and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0703300000010001", "intro": "The AMS D RFID 1 board has an error." }, { "ecode": "1803210000020005", "intro": "AMS-HT D Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0701210000010085", "intro": "Failed to read the filament information from AMS B slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0701010000020002", "intro": "The AMS B assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706210000020024", "intro": "AMS G slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1800210000010085", "intro": "Failed to read the filament information from AMS-HT A slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804210000010082", "intro": "Failed to read the filament information from AMS-HT E slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0706200000020021", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1202300000010001", "intro": "AMS C Slot 1 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0700220000020015", "intro": "AMS A slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "18FE800000010002", "intro": "The Toolhead Lifting Motor position hall sensor has an open circuit; please check whether the connecting cable is loose." }, { "ecode": "1805700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1804810000010003", "intro": "AMS-HT E The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1202220000020006", "intro": "Failed to extrude AMS C Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1805230000020004", "intro": "AMS-HT F Slot 4 filament may be broken in the tool head." }, { "ecode": "0701230000020021", "intro": "AMS B slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0706300000010004", "intro": "Encryption chip failure" }, { "ecode": "1803210000020001", "intro": "AMS-HT D Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0C00030000030006", "intro": "Purged filament may have piled up in the waste chute. Please check and clean the chute." }, { "ecode": "1802230000020007", "intro": "AMS-HT C Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0702210000020014", "intro": "AMS C slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1203230000020003", "intro": "AMS D Slot4 filament may be broken in the PTFE tube." }, { "ecode": "0707800000010003", "intro": "AMS H The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0704220000020002", "intro": "AMS E Slot 3 is empty; please insert a new filament." }, { "ecode": "1201230000030001", "intro": "AMS B Slot4 filament has run out. Purging the old filament; please wait." }, { "ecode": "18FE800000010004", "intro": "The Toolhead Lifting Motor position hall sensor is short-circuited; please check if the Hall sensor is malfunctioning." }, { "ecode": "0703220000010085", "intro": "Failed to read the filament information from AMS D slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1803800000010003", "intro": "AMS-HT D The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1801900000010003", "intro": "AMS-HT B The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "180222000002000A", "intro": "Failed to adjust the filament position of AMS-HT C Slot 3. The filament or buffer may be stuck." }, { "ecode": "1804200000020013", "intro": "AMS-HT E slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1805010000020006", "intro": "AMS-HT F The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1804800000010003", "intro": "AMS-HT E The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1806720000020005", "intro": "Failed to feed the AMS-HT G Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1803200000010081", "intro": "Failed to read the filament information from AMS-HT D slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1807210000020024", "intro": "AMS-HT H slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200210000020003", "intro": "AMS A Slot2 filament may be broken in the PTFE tube." }, { "ecode": "1806210000010083", "intro": "Failed to read the filament information from AMS-HT G slot 2. The RFID tag may be damaged." }, { "ecode": "0700250000020001", "intro": "AMS A uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0705910000020001", "intro": "AMS F The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0700230000020012", "intro": "AMS A slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800210000030001", "intro": "AMS-HT A Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0707010000020010", "intro": "AMS H The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0704200000020017", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1806550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "1200300000010001", "intro": "AMS A Slot 1 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0703230000020020", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0707020000020002", "intro": "AMS H The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0706200000020005", "intro": "AMS G Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1805220000020003", "intro": "AMS-HT F Slot 3's filament may be broken in AMS-HT." }, { "ecode": "0701010000020007", "intro": "AMS B The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0702230000020001", "intro": "AMS C Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0706110000010001", "intro": "The AMS G slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1202720000010001", "intro": "AMS C Filament speed and length error: The slot 3 filament odometry may be faulty." }, { "ecode": "1805800000010003", "intro": "AMS-HT F The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1806710000020001", "intro": "Failed to pull out the AMS-HT G Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0705200000010085", "intro": "Failed to read the filament information from AMS F slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0700810000010004", "intro": "AMS A The heater 2 is heating abnormally." }, { "ecode": "0701230000020007", "intro": "AMS B Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705210000010085", "intro": "Failed to read the filament information from AMS F slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0700200000020001", "intro": "AMS A Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1803210000020020", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0704230000020020", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1806220000020023", "intro": "AMS-HT G slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0702220000020020", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1801300000020002", "intro": "The RFID-tag on AMS-HT B Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1806200000020009", "intro": "Failed to extrude AMS-HT G Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800210000030002", "intro": "AMS-HT A Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1801200000020017", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705310000010004", "intro": "Encryption chip failure" }, { "ecode": "1806200000020010", "intro": "AMS-HT G slot 1 feeds filament out of AMS timeout." }, { "ecode": "0703230000020019", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1806210000010085", "intro": "Failed to read the filament information from AMS-HT G slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0700810000010002", "intro": "AMS A The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1200700000010001", "intro": "AMS A Filament speed and length error: The slot 1 filament odometry may be faulty." }, { "ecode": "0300960000010002", "intro": "The front door Hall sensor (Upper) is abnormal; please check whether the connection wire is loose." }, { "ecode": "0701500000020001", "intro": "AMS B communication is abnormal; please check the connection cable." }, { "ecode": "1805210000020016", "intro": "AMS-HT F slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0300960000010003", "intro": "The front door Hall sensor (Lower) is abnormal; please check whether the connection wire is loose." }, { "ecode": "0700810000010003", "intro": "AMS A The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1200210000020006", "intro": "Failed to extrude AMS A Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1804220000010083", "intro": "Failed to read the filament information from AMS-HT E slot 3. The RFID tag may be damaged." }, { "ecode": "1806200000020004", "intro": "AMS-HT G Slot 1 filament may be broken in the tool head." }, { "ecode": "0704200000020007", "intro": "AMS E Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705230000020001", "intro": "AMS F Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0700200000020019", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1803010000010001", "intro": "The AMS-HT D assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0700700000020001", "intro": "Failed to pull out the AMS A Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0706210000020010", "intro": "AMS G slot 2 feeds filament out of AMS timeout." }, { "ecode": "0707110000020004", "intro": "AMS H The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804730000020002", "intro": "Failed to feed the AMS-HT E Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1802230000020017", "intro": "AMS-HT C slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0703730000020002", "intro": "Failed to feed the AMS D Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800210000010086", "intro": "Failed to read the filament information from AMS-HT A slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0705700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0704730000020004", "intro": "Failed to pull back the AMS E Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702200000010085", "intro": "Failed to read the filament information from AMS C slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0704230000020007", "intro": "AMS E Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1806210000020008", "intro": "AMS-HT G Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700960000020002", "intro": "AMS A Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1801200000020006", "intro": "AMS-HT B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0705210000020023", "intro": "AMS F slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0704210000020019", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0707320000020002", "intro": "The RFID-tag on AMS H Slot3 is damaged, or its content cannot be identified." }, { "ecode": "070223000002000A", "intro": "Failed to adjust the filament position of AMS C Slot 4. The filament or buffer may be stuck." }, { "ecode": "0706350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1800450000020002", "intro": "The filament cutter's cutting distance is too large. The XY motor may lose steps." }, { "ecode": "1806220000020007", "intro": "AMS-HT G Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1805200000020013", "intro": "AMS-HT F slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703210000020019", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0C00040000010012", "intro": "Live View Camera data link is abnormal." }, { "ecode": "1804120000020004", "intro": "AMS-HT E The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703200000020007", "intro": "AMS D Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1802700000020005", "intro": "Failed to feed the AMS-HT C Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1803550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0500030000010001", "intro": "The MC module is malfunctioning; please restart the device or check device cable connection." }, { "ecode": "1805230000020016", "intro": "AMS-HT F slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "180321000002000A", "intro": "Failed to adjust the filament position of AMS-HT D Slot 2. The filament or buffer may be stuck." }, { "ecode": "0703710000020001", "intro": "Failed to pull out the AMS D Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1805220000020024", "intro": "AMS-HT F slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0300C20000010002", "intro": "Hall sensor of Filter Switch Flap malfunction: please check if the wiring is loose." }, { "ecode": "1803210000020019", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1801700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1805720000020004", "intro": "Failed to pull back the AMS-HT F Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1203130000010001", "intro": "The AMS D Slot4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0703220000020019", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1804730000020004", "intro": "Failed to pull back the AMS-HT E Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704200000020021", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0704010000020002", "intro": "The AMS E assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800510000030001", "intro": "The AMS is disabled; please load filament from the spool holder." }, { "ecode": "1807220000020016", "intro": "AMS-HT H slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1803300000010001", "intro": "The AMS-HT D RFID 1 board has an error." }, { "ecode": "0500050000010012", "intro": "The Cutting Module firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1801230000010081", "intro": "Failed to read the filament information from AMS-HT B slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0700720000020004", "intro": "Failed to pull back the AMS A Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1801230000010082", "intro": "Failed to read the filament information from AMS-HT B slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1804200000020022", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1806310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0700550000010003", "intro": "AMS A was detected offline during the AMS initialization process." }, { "ecode": "1800220000020011", "intro": "AMS-HT A slot 3 pulls filament back to AMS timeout." }, { "ecode": "0707300000020002", "intro": "The RFID-tag on AMS H Slot1 is damaged, or its content cannot be identified." }, { "ecode": "0704900000010003", "intro": "AMS E The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0707500000020001", "intro": "AMS H communication is abnormal; please check the connection cable." }, { "ecode": "1203120000010001", "intro": "The AMS D Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1801020000010001", "intro": "AMS-HT B Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0705230000020020", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "18FF800000010002", "intro": "The Toolhead Lifting Motor position hall sensor has an open circuit; please check whether the connecting cable is loose." }, { "ecode": "1200820000020001", "intro": "AMS A Slot3 filament may be tangled or stuck." }, { "ecode": "0707310000010004", "intro": "Encryption chip failure" }, { "ecode": "0505050000010010", "intro": "The firmware of AMS F does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1804220000020012", "intro": "AMS-HT E slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "180422000002000A", "intro": "Failed to adjust the filament position of AMS-HT E Slot 3. The filament or buffer may be stuck." }, { "ecode": "0703250000020001", "intro": "AMS D uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "03001E0000010009", "intro": "The left nozzle temperature control is abnormal; the hot end may not be installed. If you want to heat the hot end without it being installed, please turn on maintenance mode in the settings page." }, { "ecode": "0C00040000010013", "intro": "The exposure parameters of the BirdsEye Camera are not effective; please try again." }, { "ecode": "0702210000020024", "intro": "AMS C slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807220000020001", "intro": "AMS-HT H Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1807210000020002", "intro": "AMS-HT H Slot 2 is empty; please insert a new filament." }, { "ecode": "1803240000010007", "intro": "AMS-HT D door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0707210000020016", "intro": "AMS H slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0701730000020002", "intro": "Failed to feed the AMS B Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0705210000030002", "intro": "AMS F Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1804010000020006", "intro": "AMS-HT E The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0707200000020020", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1802200000010082", "intro": "Failed to read the filament information from AMS-HT C slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1802200000020016", "intro": "AMS-HT C slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0702200000020018", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0701200000020005", "intro": "AMS B Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0703220000020016", "intro": "AMS D slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0704210000020005", "intro": "AMS E Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1200130000010003", "intro": "The AMS A Slot4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1802910000010002", "intro": "AMS-HT C The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1801200000020002", "intro": "AMS-HT B Slot 1 is empty; please insert a new filament." }, { "ecode": "1807330000020002", "intro": "The RFID-tag on AMS-HT H Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1201200000020004", "intro": "AMS B Slot1 filament may be broken in the tool head." }, { "ecode": "1800210000020010", "intro": "AMS-HT A slot 2 feeds filament out of AMS timeout." }, { "ecode": "1802350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "070622000002000A", "intro": "Failed to adjust the filament position of AMS G Slot 3. The filament or buffer may be stuck." }, { "ecode": "1805550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0705700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1807100000020004", "intro": "AMS-HT H The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802700000020001", "intro": "Failed to pull out the AMS-HT C Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0703810000010004", "intro": "AMS D The heater 2 is heating abnormally." }, { "ecode": "0C0001000002001A", "intro": "" }, { "ecode": "0703010000010004", "intro": "The AMS D assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1803600000020001", "intro": "The AMS-HT D Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1807200000010082", "intro": "Failed to read the filament information from AMS-HT H slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1805220000020012", "intro": "AMS-HT F slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0300320000020002", "intro": "The Auxiliary Part Cooling Fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "1800220000020016", "intro": "AMS-HT A slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807220000030002", "intro": "AMS-HT H Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1804310000020002", "intro": "The RFID-tag on AMS-HT E Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0706700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0703630000020001", "intro": "The AMS D Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806010000020002", "intro": "The AMS-HT G assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0700210000020013", "intro": "AMS A slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707100000020004", "intro": "AMS H The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704010000020006", "intro": "AMS E The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1807700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1203330000010001", "intro": "AMS D Slot 4 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1806220000010082", "intro": "Failed to read the filament information from AMS-HT G slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0701550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0703230000030001", "intro": "AMS D Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800230000020023", "intro": "AMS-HT A slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0706200000020009", "intro": "Failed to extrude AMS G Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0704310000010001", "intro": "The AMS E RFID 2 board has an error." }, { "ecode": "1200330000020002", "intro": "The RFID-tag on AMS A Slot 4 is damaged." }, { "ecode": "1800400000020001", "intro": "AMS-HT A Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "1807120000010001", "intro": "The AMS-HT H slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1805210000020007", "intro": "AMS-HT F Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0300010000010001", "intro": "The heatbed temperature is abnormal; the heater may have a short circuit." }, { "ecode": "1201210000030001", "intro": "AMS B Slot2 filament has run out. Purging the old filament; please wait." }, { "ecode": "0C00030000020004", "intro": "First layer inspection is not supported for the current print job." }, { "ecode": "0300900000010002", "intro": "Chamber heating failed. Possible causes: the chamber is not fully enclosed, ambient temperature is too low, or the power supply heat dissipation vent is blocked." }, { "ecode": "0300280000010008", "intro": "Z-axis homing failed. Please check if the blade holder movement is smooth and ensure no foreign objects are at the contact position on the heatbed." }, { "ecode": "0700120000010001", "intro": "The AMS A slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1806010000010011", "intro": "AMS-HT G The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1800020000010001", "intro": "AMS-HT A Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0706230000020001", "intro": "AMS G Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0702910000020001", "intro": "AMS C The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0704730000020005", "intro": "Failed to feed the AMS E Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1801210000020019", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1805610000020001", "intro": "The AMS-HT F Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1201200000020006", "intro": "Failed to extrude AMS B Slot1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1802220000020010", "intro": "AMS-HT C slot 3 feeds filament out of AMS timeout." }, { "ecode": "1803220000020011", "intro": "AMS-HT D slot 3 pulls filament back to AMS timeout." }, { "ecode": "0700010000020009", "intro": "AMS A The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0706730000020004", "intro": "Failed to pull back the AMS G Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1200330000010001", "intro": "AMS A Slot 4 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0700220000020003", "intro": "AMS A Slot 3's filament may be broken in AMS." }, { "ecode": "1807800000010003", "intro": "AMS-HT H The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1801810000010001", "intro": "AMS-HT B The current sensor of heater 2 is abnormal." }, { "ecode": "0702010000020010", "intro": "AMS C The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0703220000020022", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0704230000010084", "intro": "Failed to read the filament information from AMS E slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0702230000010083", "intro": "Failed to read the filament information from AMS C slot 4. The RFID tag may be damaged." }, { "ecode": "1805210000010081", "intro": "Failed to read the filament information from AMS-HT F slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0705020000020002", "intro": "AMS F The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0705220000020008", "intro": "AMS F Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1802200000030002", "intro": "AMS-HT C Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700920000020002", "intro": "AMS A The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "1803310000020002", "intro": "The RFID-tag on AMS-HT D Slot2 is damaged, or its content cannot be identified." }, { "ecode": "1800010000010004", "intro": "The AMS-HT A assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1805210000020014", "intro": "AMS-HT F slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0703210000020021", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0704210000020010", "intro": "AMS E slot 2 feeds filament out of AMS timeout." }, { "ecode": "0703550000010004", "intro": "The binding between AMS D and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0701800000010001", "intro": "AMS B The current sensor of heater 1 is abnormal." }, { "ecode": "1801220000010081", "intro": "Failed to read the filament information from AMS-HT B slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0704910000020001", "intro": "AMS E The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1802230000020010", "intro": "AMS-HT C slot 4 feeds filament out of AMS timeout." }, { "ecode": "0701200000020001", "intro": "AMS B Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1805010000020011", "intro": "AMS-HT F The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1200200000030001", "intro": "AMS A Slot1 filament has run out. Purging the old filament; please wait." }, { "ecode": "0500060000020021", "intro": "" }, { "ecode": "1803310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1800010000020006", "intro": "AMS-HT A The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1802010000020010", "intro": "AMS-HT C The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1807010000020002", "intro": "The AMS-HT H assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706210000020015", "intro": "AMS G slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1800220000020014", "intro": "AMS-HT A slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0701930000010001", "intro": "AMS B The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "07FF810000010004", "intro": "The position hall sensor of the Extruder Switching Motor has a short circuit; please check if the Hall sensor is malfunctioning." }, { "ecode": "0707200000020015", "intro": "AMS H slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0702210000020003", "intro": "AMS C Slot 2's filament may be broken in AMS." }, { "ecode": "0701010000020010", "intro": "AMS B The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1801200000020015", "intro": "AMS-HT B slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0707210000020001", "intro": "AMS H Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1803230000020003", "intro": "AMS-HT D Slot 4's filament may be broken in AMS-HT." }, { "ecode": "0706210000010084", "intro": "Failed to read the filament information from AMS G slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0703210000020003", "intro": "AMS D Slot 2's filament may be broken in AMS." }, { "ecode": "0707310000010001", "intro": "The AMS H RFID 2 board has an error." }, { "ecode": "0701200000020022", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0500400000010039", "intro": "Laser module Serial Number error" }, { "ecode": "1805220000010083", "intro": "Failed to read the filament information from AMS-HT F slot 3. The RFID tag may be damaged." }, { "ecode": "0707200000030001", "intro": "AMS H Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0702120000020004", "intro": "AMS C The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1203220000020001", "intro": "AMS D Slot3 filament has run out; please insert a new filament." }, { "ecode": "1805020000010001", "intro": "AMS-HT F Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0700100000010001", "intro": "The AMS A slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702210000020008", "intro": "AMS C Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0705200000020009", "intro": "Failed to extrude AMS F Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1806230000010085", "intro": "Failed to read the filament information from AMS-HT G slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1803230000020014", "intro": "AMS-HT D slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1802220000020019", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706230000010085", "intro": "Failed to read the filament information from AMS G slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1802210000010086", "intro": "Failed to read the filament information from AMS-HT C slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0700910000010003", "intro": "AMS A The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "050005000001000A", "intro": "" }, { "ecode": "0703010000020008", "intro": "AMS D The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1804700000020002", "intro": "Failed to feed the AMS-HT E Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704200000020006", "intro": "AMS E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1807220000020014", "intro": "AMS-HT H slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1807110000010001", "intro": "The AMS-HT H slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1202210000020001", "intro": "AMS C Slot2 filament has run out; please insert a new filament." }, { "ecode": "0701720000020004", "intro": "Failed to pull back the AMS B Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1200110000010001", "intro": "The AMS A Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1802010000010005", "intro": "AMS-HT C The current sensor of assist motor may be faulty." }, { "ecode": "1800220000020021", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801900000010002", "intro": "AMS-HT B The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0500040000020038", "intro": "Please slide in cutting module and fasten the quick release lever. If already installed, the module might not be properly aligned. Please try reinstalling it." }, { "ecode": "1807720000020004", "intro": "Failed to pull back the AMS-HT H Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0705210000020012", "intro": "AMS F slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0705230000020010", "intro": "AMS F slot 4 feeds filament out of AMS timeout." }, { "ecode": "0706250000020001", "intro": "AMS G uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0706200000010084", "intro": "Failed to read the filament information from AMS G slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0702310000010001", "intro": "The AMS C RFID 2 board has an error." }, { "ecode": "1802210000010084", "intro": "Failed to read the filament information from AMS-HT C slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706100000010001", "intro": "The AMS G slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0700200000020010", "intro": "AMS A slot 1 feeds filament out of AMS timeout." }, { "ecode": "0500030000010023", "intro": "The Chamber Temperature Control module is malfunctioning. Please restart the device." }, { "ecode": "1807220000030001", "intro": "AMS-HT H Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1803230000020021", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1800240000010007", "intro": "AMS-HT A door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0704220000020004", "intro": "AMS E Slot 3 filament may be broken in the tool head." }, { "ecode": "1805210000020005", "intro": "AMS-HT F Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1804230000020024", "intro": "AMS-HT E slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0701100000020002", "intro": "The AMS B slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1802130000010001", "intro": "The AMS-HT C slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702710000020005", "intro": "Failed to feed the AMS C Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1804100000020004", "intro": "AMS-HT E The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0703200000020009", "intro": "Failed to extrude AMS D Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0701010000010011", "intro": "AMS B The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1803110000020004", "intro": "AMS-HT D The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801230000020009", "intro": "Failed to extrude AMS-HT B Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1201820000020001", "intro": "AMS B Slot3 filament may be tangled or stuck." }, { "ecode": "050004000002001A", "intro": "The RFID-tag on AMS C Slot3 cannot be identified." }, { "ecode": "1201110000020002", "intro": "The AMS B Slot2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0703910000020001", "intro": "AMS D The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1200110000020002", "intro": "The AMS A Slot2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0701300000010001", "intro": "The AMS B RFID 1 board has an error." }, { "ecode": "1802210000020003", "intro": "AMS-HT C Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1802200000010084", "intro": "Failed to read the filament information from AMS-HT C slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1804220000010085", "intro": "Failed to read the filament information from AMS-HT E slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804210000020011", "intro": "AMS-HT E slot 2 pulls filament back to AMS timeout." }, { "ecode": "0705220000020002", "intro": "AMS F Slot 3 is empty; please insert a new filament." }, { "ecode": "1801200000020020", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706230000020009", "intro": "Failed to extrude AMS G Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1804110000010003", "intro": "The AMS-HT E slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0704210000020022", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1804220000020008", "intro": "AMS-HT E Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1801210000020021", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1803730000020001", "intro": "Failed to pull out the AMS-HT D Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701220000020004", "intro": "AMS B Slot 3 filament may be broken in the tool head." }, { "ecode": "0500030000010005", "intro": "Internal service is malfunctioning. Please restart the device." }, { "ecode": "0706220000020016", "intro": "AMS G slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1804210000010081", "intro": "Failed to read the filament information from AMS-HT E slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0705210000020021", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0702920000010001", "intro": "AMS C The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "070322000002000A", "intro": "Failed to adjust the filament position of AMS D Slot 3. The filament or buffer may be stuck." }, { "ecode": "0707210000020019", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0705220000020021", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0300070000010003", "intro": "The resistance of Motor-B is abnormal; the motor may have failed." }, { "ecode": "1806300000010001", "intro": "The AMS-HT G RFID 1 board has an error." }, { "ecode": "1805230000020012", "intro": "AMS-HT F slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0706120000020004", "intro": "AMS G The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807220000020020", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1802010000020011", "intro": "AMS-HT C The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0707200000020004", "intro": "AMS H Slot 1 filament may be broken in the tool head." }, { "ecode": "0704200000020005", "intro": "AMS E Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1803200000020018", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703230000020009", "intro": "Failed to extrude AMS D Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800900000010003", "intro": "AMS-HT A The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0C00010000020019", "intro": "" }, { "ecode": "0704930000020002", "intro": "AMS E The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1802230000020016", "intro": "AMS-HT C slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0703800000010003", "intro": "AMS D The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "180723000002000A", "intro": "Failed to adjust the filament position of AMS-HT H Slot 4. The filament or buffer may be stuck." }, { "ecode": "0702350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1805210000010086", "intro": "Failed to read the filament information from AMS-HT F slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0C00030000030007", "intro": "Possible first layer defects have been detected. Please check the first layer quality and decide if the job should be stopped." }, { "ecode": "0702300000020002", "intro": "The RFID-tag on AMS C Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1805210000020019", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706010000020007", "intro": "AMS G The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0705230000020004", "intro": "AMS F Slot 4 filament may be broken in the tool head." }, { "ecode": "1804230000020002", "intro": "AMS-HT E Slot 4 is empty; please insert a new filament." }, { "ecode": "1800230000020015", "intro": "AMS-HT A slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1203200000030002", "intro": "AMS D Slot1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700620000020001", "intro": "The AMS A Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0705310000010001", "intro": "The AMS F RFID 2 board has an error." }, { "ecode": "1802230000010081", "intro": "Failed to read the filament information from AMS-HT C slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0703220000020020", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0703230000020012", "intro": "AMS D slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0701200000030002", "intro": "AMS B Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0300950000010008", "intro": "The Laser Module communication is abnormal; please check the connector." }, { "ecode": "0704800000010004", "intro": "AMS E The heater 1 is heating abnormally." }, { "ecode": "0703900000010002", "intro": "AMS D The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0702100000010003", "intro": "The AMS C slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0705200000020022", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0701210000020011", "intro": "AMS B slot 2 pulls filament back to AMS timeout." }, { "ecode": "1805220000010085", "intro": "Failed to read the filament information from AMS-HT F slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1803120000010003", "intro": "The AMS-HT D slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "18FE200000020002", "intro": "No filament was detected in the left extruder from the external spool; please load the new filament." }, { "ecode": "0500060000020032", "intro": "Nozzle Camera is not connected. Please check the hardware and cable connections." }, { "ecode": "0300350000020002", "intro": "The MC module cooling fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "1804230000020013", "intro": "AMS-HT E slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800720000020002", "intro": "Failed to feed the AMS-HT A Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702940000010001", "intro": "AMS C The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1801910000010002", "intro": "AMS-HT B The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1805330000020002", "intro": "The RFID-tag on AMS-HT F Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1803910000010003", "intro": "AMS-HT D The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1806210000020003", "intro": "AMS-HT G Slot 2's filament may be broken in AMS-HT." }, { "ecode": "0703550000010003", "intro": "AMS D was detected offline during the AMS initialization process." }, { "ecode": "1802010000020006", "intro": "AMS-HT C The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "070421000002000A", "intro": "Failed to adjust the filament position of AMS E Slot 2. The filament or buffer may be stuck." }, { "ecode": "0300020000010006", "intro": "The right nozzle temperature is abnormal; the sensor may have a short circuit, please check whether the connector is properly plugged in." }, { "ecode": "0C00020000020009", "intro": "The vertical laser is not bright enough at homing position. Please clean or replace the heatbed if this message appears repeatedly." }, { "ecode": "030001000001000A", "intro": "The heatbed temperature control is abnormal; the AC board may be broken." }, { "ecode": "1805200000030002", "intro": "AMS-HT F Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0706720000020005", "intro": "Failed to feed the AMS G Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1805230000010084", "intro": "Failed to read the filament information from AMS-HT F slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1803710000020004", "intro": "Failed to pull back the AMS-HT D Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800120000020002", "intro": "The AMS-HT A slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704130000010001", "intro": "The AMS E slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0703730000020005", "intro": "Failed to feed the AMS D Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1805200000020019", "intro": "AMS-HT F slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0300140000010001", "intro": "The current sensor of Motor-B is abnormal. This may be caused by a failure of the hardware sampling circuit." }, { "ecode": "1802230000020003", "intro": "AMS-HT C Slot 4's filament may be broken in AMS-HT." }, { "ecode": "1806130000010001", "intro": "The AMS-HT G slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1801220000020013", "intro": "AMS-HT B slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801130000010003", "intro": "The AMS-HT B slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706230000010082", "intro": "Failed to read the filament information from AMS G slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1807730000020001", "intro": "Failed to pull out the AMS-HT H Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1203330000030003", "intro": "AMS D Slot4 RFID cannot be read because of a structural error." }, { "ecode": "1806310000010004", "intro": "Encryption chip failure" }, { "ecode": "0705210000020022", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0700210000010084", "intro": "Failed to read the filament information from AMS A slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1801920000010001", "intro": "AMS-HT B The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1801940000010001", "intro": "AMS-HT B The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1802330000020002", "intro": "The RFID-tag on AMS-HT C Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1801720000020004", "intro": "Failed to pull back the AMS-HT B Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803930000020002", "intro": "AMS-HT D The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1203320000020002", "intro": "The RFID-tag on AMS D Slot 3 is damaged." }, { "ecode": "1801230000020004", "intro": "AMS-HT B Slot 4 filament may be broken in the tool head." }, { "ecode": "1805310000010001", "intro": "The AMS-HT F RFID 2 board has an error." }, { "ecode": "0704710000020005", "intro": "Failed to feed the AMS E Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707220000020018", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1800810000010001", "intro": "AMS-HT A The current sensor of heater 2 is abnormal." }, { "ecode": "0707010000010001", "intro": "The AMS H assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "1806700000020001", "intro": "Failed to pull out the AMS-HT G Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1802300000010001", "intro": "The AMS-HT C RFID 1 board has an error." }, { "ecode": "1801210000020024", "intro": "AMS-HT B slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1800210000020020", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1202220000020005", "intro": "AMS C Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "1804220000020010", "intro": "AMS-HT E slot 3 feeds filament out of AMS timeout." }, { "ecode": "1802700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1801230000020001", "intro": "AMS-HT B Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "0703220000020014", "intro": "AMS D slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0706710000020001", "intro": "Failed to pull out the AMS G Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0704220000020020", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1805910000010002", "intro": "AMS-HT F The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0703210000020007", "intro": "AMS D Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1804960000020002", "intro": "AMS-HT E Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1806610000020001", "intro": "The AMS-HT G Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806220000010081", "intro": "Failed to read the filament information from AMS-HT G slot 3. The AMS main board may be malfunctioning." }, { "ecode": "03009C0000010002", "intro": "The Air Pump is abnormal and may be damaged." }, { "ecode": "0700700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1807220000010086", "intro": "Failed to read the filament information from AMS-HT H slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703230000020016", "intro": "AMS D slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0700960000010003", "intro": "AMS A Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1803960000020002", "intro": "AMS-HT D Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0707350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1806200000020016", "intro": "AMS-HT G slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0300950000010001", "intro": "The temperature sensor of the Laser Module may have a short circuit." }, { "ecode": "0704910000010002", "intro": "AMS E The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0706200000020015", "intro": "AMS G slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0707800000010002", "intro": "AMS H The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0705730000020001", "intro": "Failed to pull out the AMS F Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "12FF200000020007", "intro": "Failed to check the filament location in the tool head; please click for more help." }, { "ecode": "0700220000010084", "intro": "Failed to read the filament information from AMS A slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1806930000020002", "intro": "AMS-HT G The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1807100000010003", "intro": "The AMS-HT H slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801200000010082", "intro": "Failed to read the filament information from AMS-HT B slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1807940000010001", "intro": "AMS-HT H The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0701220000010083", "intro": "Failed to read the filament information from AMS B slot 3. The RFID tag may be damaged." }, { "ecode": "1806230000020009", "intro": "Failed to extrude AMS-HT G Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1802200000020017", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0702960000010003", "intro": "AMS C Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0300980000010001", "intro": "The left side window seems to be open, the task has been paused." }, { "ecode": "0C0003000003000B", "intro": "Inspecting the first layer: please wait a moment." }, { "ecode": "0300260000010005", "intro": "Z-axis motor rotation is obstructed; please check if foreign objects are stuck in the Z slider or Z timing pulley. Also, ensure the build plate is placed correctly to avoid collisions with surrounding structures." }, { "ecode": "0703210000020012", "intro": "AMS D slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0703230000020013", "intro": "AMS D slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702230000020004", "intro": "AMS C Slot 4 filament may be broken in the tool head." }, { "ecode": "1800910000010003", "intro": "AMS-HT A The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1802120000020004", "intro": "AMS-HT C The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803130000010001", "intro": "The AMS-HT D slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1803020000010001", "intro": "AMS-HT D Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1800330000020002", "intro": "The RFID-tag on AMS-HT A Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0702120000010003", "intro": "The AMS C slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703100000020002", "intro": "The AMS D slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807200000010084", "intro": "Failed to read the filament information from AMS-HT H slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1805300000010001", "intro": "The AMS-HT F RFID 1 board has an error." }, { "ecode": "1801230000020005", "intro": "AMS-HT B Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0702210000020016", "intro": "AMS C slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0703200000010086", "intro": "Failed to read the filament information from AMS D slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1202110000010001", "intro": "The AMS C Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0705210000020017", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0701020000010001", "intro": "AMS B Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1802220000010083", "intro": "Failed to read the filament information from AMS-HT C slot 3. The RFID tag may be damaged." }, { "ecode": "0700220000020009", "intro": "Failed to extrude AMS A Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0703220000020009", "intro": "Failed to extrude AMS D Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807230000020020", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1806010000010004", "intro": "The AMS-HT G assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1202100000010001", "intro": "The AMS C Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707110000020002", "intro": "The AMS H slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704200000020013", "intro": "AMS E slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1202200000020005", "intro": "AMS C Slot1 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "1807950000010001", "intro": "AMS-HT H The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1807220000020012", "intro": "AMS-HT H slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800200000020024", "intro": "AMS-HT A slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1803300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0300130000010001", "intro": "The current sensor of Motor-A is abnormal. This may be caused by a failure of the hardware sampling circuit." }, { "ecode": "1806210000020001", "intro": "AMS-HT G Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1805200000020007", "intro": "AMS-HT F Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0706120000010003", "intro": "The AMS G slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1807230000020009", "intro": "Failed to extrude AMS-HT H Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1803220000020003", "intro": "AMS-HT D Slot 3's filament may be broken in AMS-HT." }, { "ecode": "18FF810000010002", "intro": "The position hall sensor of the Extruder Switching Motor has an open circuit. Please check whether the connecting cable is loose." }, { "ecode": "0500040000020019", "intro": "The RFID-tag on AMS C Slot2 cannot be identified." }, { "ecode": "0706810000010002", "intro": "AMS G The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1803620000020001", "intro": "The AMS-HT D Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1801220000020024", "intro": "AMS-HT B slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0700230000010086", "intro": "Failed to read the filament information from AMS A slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0707720000020002", "intro": "Failed to feed the AMS H Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0707700000020005", "intro": "Failed to feed the AMS H Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0701210000010086", "intro": "Failed to read the filament information from AMS B slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1801910000020001", "intro": "AMS-HT B The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1806110000010003", "intro": "The AMS-HT G slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1807230000020014", "intro": "AMS-HT H slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705300000020002", "intro": "The RFID-tag on AMS F Slot1 is damaged, or its content cannot be identified." }, { "ecode": "0707220000020007", "intro": "AMS H Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0706350000010002", "intro": "AMS G The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701100000010003", "intro": "The AMS B slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801630000020001", "intro": "The AMS-HT B Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1804200000020014", "intro": "AMS-HT E slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0500030000020015", "intro": "" }, { "ecode": "1802220000020013", "intro": "AMS-HT C slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802120000020002", "intro": "The AMS-HT C slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805120000010003", "intro": "The AMS-HT F slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701200000010082", "intro": "Failed to read the filament information from AMS B slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0705720000020004", "intro": "Failed to pull back the AMS F Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702960000010001", "intro": "AMS C The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "1802710000020005", "intro": "Failed to feed the AMS-HT C Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707200000020007", "intro": "AMS H Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705720000020001", "intro": "Failed to pull out the AMS F Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1805110000020002", "intro": "The AMS-HT F slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707230000020022", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0702220000020014", "intro": "AMS C slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1802210000020004", "intro": "AMS-HT C Slot 2 filament may be broken in the tool head." }, { "ecode": "0707200000020006", "intro": "AMS H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0705210000020008", "intro": "AMS F Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700200000030002", "intro": "AMS A Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704220000030001", "intro": "AMS E Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "03009E0000030001", "intro": "Open Door Detection level for this print job will be set as \"Notification\"." }, { "ecode": "0704810000010002", "intro": "AMS E The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0707710000020005", "intro": "Failed to feed the AMS H Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1200230000030001", "intro": "AMS A Slot4 filament has run out. Purging the old filament; please wait." }, { "ecode": "0704210000030002", "intro": "AMS E Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700120000020004", "intro": "AMS A The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807130000020004", "intro": "AMS-HT H The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800230000020019", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1801700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0300D00000010001", "intro": "The cutting module base has fallen off; please reinstall it." }, { "ecode": "1802010000020002", "intro": "The AMS-HT C assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1801210000020008", "intro": "AMS-HT B Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701230000020010", "intro": "AMS B slot 4 feeds filament out of AMS timeout." }, { "ecode": "1806200000020008", "intro": "AMS-HT G Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1200320000030003", "intro": "AMS A Slot3 RFID cannot be read because of a structural error." }, { "ecode": "1803220000020004", "intro": "AMS-HT D Slot 3 filament may be broken in the tool head." }, { "ecode": "0300200000010003", "intro": "X axis homing abnormal: the timing belt may be loose." }, { "ecode": "1803230000010084", "intro": "Failed to read the filament information from AMS-HT D slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1201200000030001", "intro": "AMS B Slot1 filament has run out. Purging the old filament; please wait." }, { "ecode": "0705130000020002", "intro": "The AMS F slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "07FE200000020004", "intro": "Please pull the external filament from the left extruder." }, { "ecode": "0707230000020018", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "070120000002000A", "intro": "Failed to adjust the filament position of AMS B Slot 1. The filament or buffer may be stuck." }, { "ecode": "0703210000020004", "intro": "AMS D Slot 2 filament may be broken in the tool head." }, { "ecode": "0C00010000010012", "intro": "The Live View Camera calibration failed and the calibration result could not be saved. Please try recalibrating. If calibration fails repeatedly, please contact the customer support team." }, { "ecode": "1801200000020001", "intro": "AMS-HT B Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0705350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0704220000020010", "intro": "AMS E slot 3 feeds filament out of AMS timeout." }, { "ecode": "050001000001000A", "intro": "" }, { "ecode": "1801220000020016", "intro": "AMS-HT B slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1803200000020003", "intro": "AMS-HT D Slot 1's filament may be broken in AMS-HT." }, { "ecode": "1800210000020008", "intro": "AMS-HT A Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "12FF200000020006", "intro": "Failed to extrude the filament; the extruder may be clogged." }, { "ecode": "1801110000020004", "intro": "AMS-HT B The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1202330000030003", "intro": "AMS C Slot4 RFID cannot be read because of a structural error." }, { "ecode": "0500050000010010", "intro": "The firmware of AMS A does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0706010000010003", "intro": "The AMS G assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1805230000010083", "intro": "Failed to read the filament information from AMS-HT F slot 4. The RFID tag may be damaged." }, { "ecode": "0706630000020001", "intro": "The AMS G Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300090000010003", "intro": "The resistance of the extruder servo motor is abnormal; the motor may have failed." }, { "ecode": "03000F0000010001", "intro": "Abnormal accelerometer data detected. Please try restarting the printer." }, { "ecode": "1805220000010084", "intro": "Failed to read the filament information from AMS-HT F slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0704230000020015", "intro": "AMS E slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1803230000020018", "intro": "AMS-HT D slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1805240000020009", "intro": "AMS-HT F front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "0705130000010003", "intro": "The AMS F slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "18FF450000020002", "intro": "The filament cutter's cutting distance is too large. Possible causes include the filament cutter stopper skipping teeth, motor losing steps, or the XY axis not being homed." }, { "ecode": "0704300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1802220000020003", "intro": "AMS-HT C Slot 3's filament may be broken in AMS-HT." }, { "ecode": "0703010000020009", "intro": "AMS D The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0C00020000020003", "intro": "The horizontal laser is not bright enough at homing position. Please clean or replace the heatbed if this message appears repeatedly." }, { "ecode": "1806960000020002", "intro": "AMS-HT G Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0707230000020016", "intro": "AMS H slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0704330000020002", "intro": "The RFID-tag on AMS E Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0300980000010004", "intro": "The Left Laser Safety Window is not detected. Please install it according to the Wiki and re-initiate the task." }, { "ecode": "0705300000010001", "intro": "The AMS F RFID 1 board has an error." }, { "ecode": "1806600000020001", "intro": "The AMS-HT G Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702930000010001", "intro": "AMS C The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0700710000020002", "intro": "Failed to feed the AMS A Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0500060000020043", "intro": "" }, { "ecode": "1805920000010001", "intro": "AMS-HT F The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1802210000020018", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0705110000020004", "intro": "AMS F The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0300180000000000", "intro": "" }, { "ecode": "0706010000010001", "intro": "The AMS G assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "1804230000020019", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706220000010082", "intro": "Failed to read the filament information from AMS G slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0C00040000030024", "intro": "The BirdsEye Camera position is detected to be offset. To ensure engraving accuracy, it is recommended to rerun the BirdsEye Camera Setup." }, { "ecode": "1800900000020001", "intro": "AMS-HT A The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "07FE800000010002", "intro": "The Toolhead Lifting Motor position hall sensor has an open circuit; please check whether the connecting cable is loose." }, { "ecode": "1203230000020004", "intro": "AMS D Slot4 filament may be broken in the tool head." }, { "ecode": "1804210000020008", "intro": "AMS-HT E Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1806630000020001", "intro": "The AMS-HT G Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702210000020013", "intro": "AMS C slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702220000020017", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0706220000020008", "intro": "AMS G Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1202110000020002", "intro": "The AMS C Slot2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1807210000020009", "intro": "Failed to extrude AMS-HT H Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0300920000010007", "intro": "The temperature of chamber heater 2 is abnormal. The sensor may have an open circuit." }, { "ecode": "0705220000010083", "intro": "Failed to read the filament information from AMS F slot 3. The RFID tag may be damaged." }, { "ecode": "0707700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1806130000020002", "intro": "The AMS-HT G slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1804500000020001", "intro": "AMS-HT E communication is abnormal; please check the connection cable." }, { "ecode": "1800960000010003", "intro": "AMS-HT A Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1801230000010084", "intro": "Failed to read the filament information from AMS-HT B slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1804220000020009", "intro": "Failed to extrude AMS-HT E Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0702710000020004", "intro": "Failed to pull back the AMS C Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0706210000020021", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0300090000010001", "intro": "The extruder servo motor has an open circuit. The connection may be loose, or the motor may have failed." }, { "ecode": "1803230000010086", "intro": "Failed to read the filament information from AMS-HT D slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1800220000020018", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1200200000020002", "intro": "AMS A Slot 1 is empty; please insert a new filament." }, { "ecode": "0701600000020001", "intro": "The AMS B Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1203220000020006", "intro": "Failed to extrude AMS D Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707010000020006", "intro": "AMS H The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0703220000020011", "intro": "AMS D slot 3 pulls filament back to AMS timeout." }, { "ecode": "0703230000020007", "intro": "AMS D Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1806970000030001", "intro": "AMS-HT G chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1801210000020020", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1806220000010084", "intro": "Failed to read the filament information from AMS-HT G slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1800010000010011", "intro": "AMS-HT A The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "050003000002000C", "intro": "Wireless hardware error: please turn off/on WiFi or restart the device." }, { "ecode": "0703720000020005", "intro": "Failed to feed the AMS D Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0702210000020012", "intro": "AMS C slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704230000020021", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802220000020014", "intro": "AMS-HT C slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0C00010000010013", "intro": "The Live View Camera calibration failed and the Liveview camera serial number cannot be read. Please contact the customer support team." }, { "ecode": "1804350000010002", "intro": "AMS-HT E The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701230000020003", "intro": "AMS B Slot 4's filament may be broken in AMS." }, { "ecode": "0704200000020009", "intro": "Failed to extrude AMS E Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1804210000020016", "intro": "AMS-HT E slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1802110000020004", "intro": "AMS-HT C The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802210000020022", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1804020000010001", "intro": "AMS-HT E Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1807700000020001", "intro": "Failed to pull out the AMS-HT H Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701910000010002", "intro": "AMS B The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1801210000020002", "intro": "AMS-HT B Slot 2 is empty; please insert a new filament." }, { "ecode": "0706210000020023", "intro": "AMS G slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1801300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0702970000030001", "intro": "AMS C chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0500040000010004", "intro": "The print file is unauthorized." }, { "ecode": "1800700000020004", "intro": "Failed to pull back the AMS-HT A Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702210000020001", "intro": "AMS C Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "1804900000010002", "intro": "AMS-HT E The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0300940000030002", "intro": "Chamber temperature setting value exceed the limit, the boundary value will be set." }, { "ecode": "0703800000010002", "intro": "AMS D The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1804200000020019", "intro": "AMS-HT E slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1807600000020001", "intro": "The AMS-HT H Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1804110000020002", "intro": "The AMS-HT E slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0500030000010007", "intro": "The Toolhead expansion module is malfunctioning. Please power off, check the connection, and restart the device." }, { "ecode": "1806200000020003", "intro": "AMS-HT G Slot 1's filament may be broken in AMS-HT." }, { "ecode": "0707210000010085", "intro": "Failed to read the filament information from AMS H slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1807220000010085", "intro": "Failed to read the filament information from AMS-HT H slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0705220000020003", "intro": "AMS F Slot 3's filament may be broken in AMS." }, { "ecode": "0705710000020002", "intro": "Failed to feed the AMS F Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1801620000020001", "intro": "The AMS-HT B Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0701210000020015", "intro": "AMS B slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1800210000020023", "intro": "AMS-HT A slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1802230000020008", "intro": "AMS-HT C Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "07FE800000020002", "intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model." }, { "ecode": "0702220000020012", "intro": "AMS C slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1801210000020016", "intro": "AMS-HT B slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0705100000010001", "intro": "The AMS F slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0500030000010025", "intro": "The current firmware is abnormal. Please update again." }, { "ecode": "1804700000020005", "intro": "Failed to feed the AMS-HT E Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1201230000020003", "intro": "AMS B Slot4 filament may be broken in the PTFE tube." }, { "ecode": "1800120000010003", "intro": "The AMS-HT A slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801200000020016", "intro": "AMS-HT B slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0704720000020002", "intro": "Failed to feed the AMS E Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "180320000002000A", "intro": "Failed to adjust the filament position of AMS-HT D Slot 1. The filament or buffer may be stuck." }, { "ecode": "1806210000020016", "intro": "AMS-HT G slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1805200000020012", "intro": "AMS-HT F slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0700210000010083", "intro": "Failed to read the filament information from AMS A slot 2. The RFID tag may be damaged." }, { "ecode": "1802220000010086", "intro": "Failed to read the filament information from AMS-HT C slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0500020000020003", "intro": "Failed to connect to the internet; please check the network connection." }, { "ecode": "18FF810000010004", "intro": "The position hall sensor of the Extruder Switching Motor has a short circuit; please check if the Hall sensor is malfunctioning." }, { "ecode": "1801220000030001", "intro": "AMS-HT B Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0703200000020014", "intro": "AMS D slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0700110000010003", "intro": "The AMS A slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0702010000020002", "intro": "The AMS C assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1802700000020004", "intro": "Failed to pull back the AMS-HT C Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800230000010086", "intro": "Failed to read the filament information from AMS-HT A slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0704810000010004", "intro": "AMS E The heater 2 is heating abnormally." }, { "ecode": "1802200000020005", "intro": "AMS-HT C Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1803200000010086", "intro": "Failed to read the filament information from AMS-HT D slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0705810000010004", "intro": "AMS F The heater 2 is heating abnormally." }, { "ecode": "0703210000030002", "intro": "AMS D Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1800220000010083", "intro": "Failed to read the filament information from AMS-HT A slot 3. The RFID tag may be damaged." }, { "ecode": "0707220000020010", "intro": "AMS H slot 3 feeds filament out of AMS timeout." }, { "ecode": "0701220000020018", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0705200000020020", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1806200000010082", "intro": "Failed to read the filament information from AMS-HT G slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1806230000020007", "intro": "AMS-HT G Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0705220000020014", "intro": "AMS F slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1800020000020002", "intro": "AMS-HT A The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0707210000020008", "intro": "AMS H Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1203310000020002", "intro": "The RFID-tag on AMS D Slot 2 is damaged." }, { "ecode": "0702930000020002", "intro": "AMS C The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1801910000010003", "intro": "AMS-HT B The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1804810000010004", "intro": "AMS-HT E The heater 2 is heating abnormally." }, { "ecode": "0702220000020003", "intro": "AMS C Slot 3's filament may be broken in AMS." }, { "ecode": "0707010000010011", "intro": "AMS H The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1803920000010001", "intro": "AMS-HT D The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1804210000020002", "intro": "AMS-HT E Slot 2 is empty; please insert a new filament." }, { "ecode": "0701220000010084", "intro": "Failed to read the filament information from AMS B slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0500030000020017", "intro": "" }, { "ecode": "1807210000020021", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0703330000020002", "intro": "The RFID-tag on AMS D Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0700720000020001", "intro": "Failed to pull out the AMS A Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0706300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0C0001000001000B", "intro": "Failed to calibrate Micro Lidar. Please make sure the calibration chart is clean and not obscured. Then, run machine calibration again." }, { "ecode": "1202810000020001", "intro": "AMS C Slot2 filament may be tangled or stuck." }, { "ecode": "1805810000010004", "intro": "AMS-HT F The heater 2 is heating abnormally." }, { "ecode": "0701200000020017", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1805550000010003", "intro": "AMS-HT F was detected offline during the AMS initialization process." }, { "ecode": "0703300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0701120000010001", "intro": "The AMS B slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1804220000020013", "intro": "AMS-HT E slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1805230000020017", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0701700000020004", "intro": "Failed to pull back the AMS B Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0C00040000010011", "intro": "Failed to measure material thickness: device parameters abnormal; please setup BirdsEye Camera again." }, { "ecode": "0705230000010082", "intro": "Failed to read the filament information from AMS F slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "07FF800000010002", "intro": "The Toolhead Lifting Motor position hall sensor has an open circuit; please check whether the connecting cable is loose." }, { "ecode": "0707220000020019", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1805350000010002", "intro": "AMS-HT F The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701210000020021", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1806200000030001", "intro": "AMS-HT G Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0702200000020003", "intro": "AMS C Slot 1's filament may be broken in AMS." }, { "ecode": "1805230000020011", "intro": "AMS-HT F slot 4 pulls filament back to AMS timeout." }, { "ecode": "0706130000020004", "intro": "AMS G The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1201230000020006", "intro": "Failed to extrude AMS B Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0700930000020002", "intro": "AMS A The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "0701210000020017", "intro": "AMS B slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1802720000020002", "intro": "Failed to feed the AMS-HT C Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702010000010011", "intro": "AMS C The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0500010000020009", "intro": "" }, { "ecode": "1807230000010082", "intro": "Failed to read the filament information from AMS-HT H slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1801210000030001", "intro": "AMS-HT B Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1805110000010001", "intro": "The AMS-HT F slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1804920000020002", "intro": "AMS-HT E The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0702210000020010", "intro": "AMS C slot 2 feeds filament out of AMS timeout." }, { "ecode": "0705010000020008", "intro": "AMS F The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1202710000010001", "intro": "AMS C Filament speed and length error: The slot 2 filament odometry may be faulty." }, { "ecode": "1805210000020022", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0707230000020013", "intro": "AMS H slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707220000010081", "intro": "Failed to read the filament information from AMS H slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1802230000020009", "intro": "Failed to extrude AMS-HT C Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1805220000020013", "intro": "AMS-HT F slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1800950000010001", "intro": "AMS-HT A The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1801310000010001", "intro": "The AMS-HT B RFID 2 board has an error." }, { "ecode": "1805730000020001", "intro": "Failed to pull out the AMS-HT F Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0702730000020004", "intro": "Failed to pull back the AMS C Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "180521000002000A", "intro": "Failed to adjust the filament position of AMS-HT F Slot 2. The filament or buffer may be stuck." }, { "ecode": "18FF800000020001", "intro": "The lifting action is abnormal during the extruder switch. Please check whether the flow blocker is stuck or there is filament stuck in the toolhead." }, { "ecode": "0705110000010003", "intro": "The AMS F slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804220000020002", "intro": "AMS-HT E Slot 3 is empty; please insert a new filament." }, { "ecode": "0703200000020008", "intro": "AMS D Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1804550000010004", "intro": "The binding between AMS-HT E and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0707220000020022", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1807220000020015", "intro": "AMS-HT H slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0703210000030001", "intro": "AMS D Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "0500060000020006", "intro": "" }, { "ecode": "1805210000020001", "intro": "AMS-HT F Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0700210000010085", "intro": "Failed to read the filament information from AMS A slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804200000010085", "intro": "Failed to read the filament information from AMS-HT E slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0C00030000030010", "intro": "Your printer seems to be printing without extruding." }, { "ecode": "0702230000020024", "intro": "AMS C slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200120000010001", "intro": "The AMS A Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1203300000010004", "intro": "RFID cannot be read because of an encryption chip failure in AMS D." }, { "ecode": "0704230000020019", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1201330000020002", "intro": "The RFID-tag on AMS B Slot 4 is damaged." }, { "ecode": "1802300000010004", "intro": "Encryption chip failure" }, { "ecode": "0704200000020019", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1806200000020018", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1803210000020017", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0707910000020001", "intro": "AMS H The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0703220000020018", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804230000020022", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0500010000020001", "intro": "The media pipeline is malfunctioning. Please restart the printer. If multiple attempts fail, please contact customer support." }, { "ecode": "1802230000020002", "intro": "AMS-HT C Slot 4 is empty; please insert a new filament." }, { "ecode": "1806010000010005", "intro": "AMS-HT G The current sensor of assist motor may be faulty." }, { "ecode": "070522000002000A", "intro": "Failed to adjust the filament position of AMS F Slot 3. The filament or buffer may be stuck." }, { "ecode": "1201120000020002", "intro": "The AMS B Slot3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0705200000020001", "intro": "AMS F Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1807970000030001", "intro": "AMS-HT H chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "0701130000010001", "intro": "The AMS B slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0500040000020036", "intro": "New Cutting Module connected. To ensure more precise cutting, please set it up before use. (about 3 minutes)" }, { "ecode": "1803970000030001", "intro": "AMS-HT D chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1800230000020018", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0704210000020003", "intro": "AMS E Slot 2's filament may be broken in AMS." }, { "ecode": "1803700000020001", "intro": "Failed to pull out the AMS-HT D Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701210000020016", "intro": "AMS B slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1802230000020011", "intro": "AMS-HT C slot 4 pulls filament back to AMS timeout." }, { "ecode": "1804220000010081", "intro": "Failed to read the filament information from AMS-HT E slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1806300000010004", "intro": "Encryption chip failure" }, { "ecode": "1203230000020002", "intro": "AMS D Slot 4 is empty; please insert a new filament." }, { "ecode": "0500060000020004", "intro": "The Live View camera is not in place; please check the hardware connection." }, { "ecode": "1801230000010083", "intro": "Failed to read the filament information from AMS-HT B slot 4. The RFID tag may be damaged." }, { "ecode": "1803230000010081", "intro": "Failed to read the filament information from AMS-HT D slot 4. The AMS main board may be malfunctioning." }, { "ecode": "0500060000020003", "intro": "BirdsEye Camera is not in place; please check the hardware connection" }, { "ecode": "1802230000020014", "intro": "AMS-HT C slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0706010000020006", "intro": "AMS G The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1803720000020005", "intro": "Failed to feed the AMS-HT D Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1803200000020001", "intro": "AMS-HT D Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1807110000020002", "intro": "The AMS-HT H slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1203310000010001", "intro": "AMS D Slot 2 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0705700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0300260000010002", "intro": "The sensitivity of the left extruder extrusion force sensor is low; the force sensor may not be installed correctly." }, { "ecode": "05000600000200A1", "intro": "" }, { "ecode": "0706800000010003", "intro": "AMS G The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0700200000010082", "intro": "Failed to read the filament information from AMS A slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0704230000020023", "intro": "AMS E slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0500040000020037", "intro": "The Cutting Module needs calibration to get the tool position. Please perform the mounting calibration before use. (about 2-4 minutes)" }, { "ecode": "1802930000020002", "intro": "AMS-HT C The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1203300000030003", "intro": "AMS D Slot1 RFID cannot be read because of a structural error." }, { "ecode": "1800210000020009", "intro": "Failed to extrude AMS-HT A Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0700710000020001", "intro": "Failed to pull out the AMS A Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1803200000020023", "intro": "AMS-HT D slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0707800000010001", "intro": "AMS H The current sensor of heater 1 is abnormal." }, { "ecode": "1800230000020014", "intro": "AMS-HT A slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1801800000010004", "intro": "AMS-HT B The heater 1 is heating abnormally." }, { "ecode": "0701230000010085", "intro": "Failed to read the filament information from AMS B slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0706100000020002", "intro": "The AMS G slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706210000020013", "intro": "AMS G slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705010000010004", "intro": "The AMS F assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1804210000020009", "intro": "Failed to extrude AMS-HT E Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707300000010004", "intro": "Encryption chip failure" }, { "ecode": "1203200000030001", "intro": "AMS D Slot1 filament has run out. Purging the old filament; please wait." }, { "ecode": "0706230000020021", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1806960000010003", "intro": "AMS-HT G Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1806010000020010", "intro": "AMS-HT G The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1804230000010083", "intro": "Failed to read the filament information from AMS-HT E slot 4. The RFID tag may be damaged." }, { "ecode": "0707200000020022", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "050004000002001B", "intro": "The RFID-tag on AMS C Slot4 cannot be identified." }, { "ecode": "0707200000020018", "intro": "AMS H slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1804200000020011", "intro": "AMS-HT E slot 1 pulls filament back to AMS timeout." }, { "ecode": "0705700000020001", "intro": "Failed to pull out the AMS F Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0706550000010004", "intro": "The binding between AMS G and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0503050000010010", "intro": "The firmware of AMS D does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0700400000020001", "intro": "AMS A Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "1800230000030001", "intro": "AMS-HT A Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0703220000020015", "intro": "AMS D slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700300000010001", "intro": "The AMS A RFID 1 board has an error." }, { "ecode": "0705200000020016", "intro": "AMS F slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0706210000020009", "intro": "Failed to extrude AMS G Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1803230000020005", "intro": "AMS-HT D Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1200220000020001", "intro": "AMS A Slot3 filament has run out; please insert a new filament." }, { "ecode": "1805900000010002", "intro": "AMS-HT F The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1807230000020013", "intro": "AMS-HT H slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802210000020023", "intro": "AMS-HT C slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0702220000020005", "intro": "AMS C Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0300910000010003", "intro": "The temperature of chamber heater 1 is abnormal. The heater is over temperature." }, { "ecode": "1803230000020023", "intro": "AMS-HT D slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0704010000010004", "intro": "The AMS E assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1804720000020001", "intro": "Failed to pull out the AMS-HT E Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1807200000020007", "intro": "AMS-HT H Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0707210000020024", "intro": "AMS H slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0701210000030002", "intro": "AMS B Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704210000010083", "intro": "Failed to read the filament information from AMS E slot 2. The RFID tag may be damaged." }, { "ecode": "0701200000020006", "intro": "AMS B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0707200000020008", "intro": "AMS H Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701200000010084", "intro": "Failed to read the filament information from AMS B slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1203320000030003", "intro": "AMS D Slot3 RFID cannot be read because of a structural error." }, { "ecode": "0702200000020016", "intro": "AMS C slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0C00040000020023", "intro": "Thickness measurement failed, the Toolhead Camera was unable to detect the material surface." }, { "ecode": "18FF800000020003", "intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate." }, { "ecode": "0C00030000020011", "intro": "The high-precision nozzle offset calibration failed; please recalibrate." }, { "ecode": "1805210000020020", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701200000020016", "intro": "AMS B slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1803120000010001", "intro": "The AMS-HT D slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0506050000010010", "intro": "The firmware of AMS G does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "070121000002000A", "intro": "Failed to adjust the filament position of AMS B Slot 2. The filament or buffer may be stuck." }, { "ecode": "0701220000020011", "intro": "AMS B slot 3 pulls filament back to AMS timeout." }, { "ecode": "0707210000010082", "intro": "Failed to read the filament information from AMS H slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1800230000020002", "intro": "AMS-HT A Slot 4 is empty; please insert a new filament." }, { "ecode": "1806200000020020", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1202120000010001", "intro": "The AMS C Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "07FE600000020001", "intro": "External spool connected to left extruder may be tangled or jammed." }, { "ecode": "0702310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1803730000020004", "intro": "Failed to pull back the AMS-HT D Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800220000010086", "intro": "Failed to read the filament information from AMS-HT A slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0704210000020023", "intro": "AMS E slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1800100000020004", "intro": "AMS-HT A The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0706230000020005", "intro": "AMS G Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1800200000010083", "intro": "Failed to read the filament information from AMS-HT A slot 1. The RFID tag may be damaged." }, { "ecode": "0701230000030002", "intro": "AMS B Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1806220000020022", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "03009D0000020003", "intro": "The engrave laser focal point Z calibration result differs significantly from the design values. Please re-install the Laser Module and re-run the Laser Module Setup. If it fails repeatedly, please get in touch with customer support." }, { "ecode": "0704220000020011", "intro": "AMS E slot 3 pulls filament back to AMS timeout." }, { "ecode": "0706200000010086", "intro": "Failed to read the filament information from AMS G slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1807220000020017", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1807610000020001", "intro": "The AMS-HT H Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800230000020003", "intro": "AMS-HT A Slot 4's filament may be broken in AMS-HT." }, { "ecode": "1807200000020019", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0707950000010001", "intro": "AMS H The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0705630000020001", "intro": "The AMS F Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1802220000020021", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1806100000010001", "intro": "The AMS-HT G slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1201500000020001", "intro": "AMS B communication is abnormal; please check the connection cable." }, { "ecode": "0500060000020013", "intro": "" }, { "ecode": "0705310000020002", "intro": "The RFID-tag on AMS F Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0500010000030009", "intro": "" }, { "ecode": "0706230000010084", "intro": "Failed to read the filament information from AMS G slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1804730000020001", "intro": "Failed to pull out the AMS-HT E Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1800230000010082", "intro": "Failed to read the filament information from AMS-HT A slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0706200000020003", "intro": "AMS G Slot 1's filament may be broken in AMS." }, { "ecode": "0300970000010001", "intro": "The top cover seems to be open; the task has been paused" }, { "ecode": "1803230000020010", "intro": "AMS-HT D slot 4 feeds filament out of AMS timeout." }, { "ecode": "1800220000020015", "intro": "AMS-HT A slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0706200000020008", "intro": "AMS G Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704610000020001", "intro": "The AMS E Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0704010000020010", "intro": "AMS E The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1803700000020005", "intro": "Failed to feed the AMS-HT D Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1805010000010001", "intro": "The AMS-HT F assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0700210000020023", "intro": "AMS A slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807200000010086", "intro": "Failed to read the filament information from AMS-HT H slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1807210000020003", "intro": "AMS-HT H Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1805200000020014", "intro": "AMS-HT F slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705200000020003", "intro": "AMS F Slot 1's filament may be broken in AMS." }, { "ecode": "0701630000020001", "intro": "The AMS B Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800210000020022", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "18FE200000020001", "intro": "External filament of left extruder has run out; please load a new filament." }, { "ecode": "0707730000020001", "intro": "Failed to pull out the AMS H Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0707230000030002", "intro": "AMS H Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0707700000020004", "intro": "Failed to pull back the AMS H Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701230000020016", "intro": "AMS B slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1803200000020022", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1802210000010083", "intro": "Failed to read the filament information from AMS-HT C slot 2. The RFID tag may be damaged." }, { "ecode": "050004000002001F", "intro": "The RFID-tag on AMS D Slot4 cannot be identified." }, { "ecode": "0707720000020005", "intro": "Failed to feed the AMS H Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1801230000020002", "intro": "AMS-HT B Slot 4 is empty; please insert a new filament." }, { "ecode": "1802230000020024", "intro": "AMS-HT C slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0700200000020020", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0300090000020003", "intro": "The extruder is extruding abnormally. It may be clogged, or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0300280000010003", "intro": "Communication failure between cutting module and toolhead during Z-axis homing. Please check if the cutting module signal cable is loose or broken or verify if the force sensor coil is intact." }, { "ecode": "0706220000020014", "intro": "AMS G slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0703230000020001", "intro": "AMS D Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1806220000020021", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0702800000010004", "intro": "AMS C The heater 1 is heating abnormally." }, { "ecode": "0704200000010084", "intro": "Failed to read the filament information from AMS E slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706210000010083", "intro": "Failed to read the filament information from AMS G slot 2. The RFID tag may be damaged." }, { "ecode": "0706200000010085", "intro": "Failed to read the filament information from AMS G slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0C0001000002001B", "intro": "" }, { "ecode": "1202210000020005", "intro": "AMS C Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "1800130000010001", "intro": "The AMS-HT A slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0703220000030002", "intro": "AMS D Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1202110000010003", "intro": "The AMS C Slot2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0707210000020007", "intro": "AMS H Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1803100000010001", "intro": "The AMS-HT D slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1804550000010003", "intro": "AMS-HT E was detected offline during the AMS initialization process." }, { "ecode": "1201100000010001", "intro": "The AMS B Slot1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0703230000020011", "intro": "AMS D slot 4 pulls filament back to AMS timeout." }, { "ecode": "1806230000020013", "intro": "AMS-HT G slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802230000020013", "intro": "AMS-HT C slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801220000020014", "intro": "AMS-HT B slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705600000020001", "intro": "The AMS F Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300990000010003", "intro": "The right side window Hall sensor (Upper) is abnormal; please check whether the connection wire is loose." }, { "ecode": "1805700000020002", "intro": "Failed to feed the AMS-HT F Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0500050000010008", "intro": "" }, { "ecode": "0706200000020006", "intro": "AMS G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0702230000020021", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "03000B0000010005", "intro": "Force sensor 2 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken." }, { "ecode": "1803220000020001", "intro": "AMS-HT D Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0300910000010002", "intro": "The temperature of chamber heater 1 is abnormal. The heater may have an open circuit or the thermal fuse may have burned out." }, { "ecode": "1805130000020002", "intro": "The AMS-HT F slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1202210000030002", "intro": "AMS C Slot2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704710000020002", "intro": "Failed to feed the AMS E Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805130000010003", "intro": "The AMS-HT F slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703220000010086", "intro": "Failed to read the filament information from AMS D slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0707230000020011", "intro": "AMS H slot 4 pulls filament back to AMS timeout." }, { "ecode": "1802220000020016", "intro": "AMS-HT C slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0702730000020005", "intro": "Failed to feed the AMS C Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1806200000030002", "intro": "AMS-HT G Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0705800000010002", "intro": "AMS F The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1800730000020002", "intro": "Failed to feed the AMS-HT A Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804210000010086", "intro": "Failed to read the filament information from AMS-HT E slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0707210000020021", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "180423000002000A", "intro": "Failed to adjust the filament position of AMS-HT E Slot 4. The filament or buffer may be stuck." }, { "ecode": "1806200000010085", "intro": "Failed to read the filament information from AMS-HT G slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1807210000010081", "intro": "Failed to read the filament information from AMS-HT H slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0700200000030001", "intro": "AMS A Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1807200000030001", "intro": "AMS-HT H Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1801220000020011", "intro": "AMS-HT B slot 3 pulls filament back to AMS timeout." }, { "ecode": "0706220000020010", "intro": "AMS G slot 3 feeds filament out of AMS timeout." }, { "ecode": "180123000002000A", "intro": "Failed to adjust the filament position of AMS-HT B Slot 4. The filament or buffer may be stuck." }, { "ecode": "0707210000020009", "intro": "Failed to extrude AMS H Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0C00040000020002", "intro": "Cutting Platform not detected. Please place the required mat for the task and continue." }, { "ecode": "1806210000010082", "intro": "Failed to read the filament information from AMS-HT G slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1807920000010001", "intro": "AMS-HT H The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "0300960000030001", "intro": "The front door is open." }, { "ecode": "0702230000020012", "intro": "AMS C slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0705230000010086", "intro": "Failed to read the filament information from AMS F slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1807230000020015", "intro": "AMS-HT H slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0703210000020011", "intro": "AMS D slot 2 pulls filament back to AMS timeout." }, { "ecode": "1202230000020005", "intro": "AMS C Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0706200000020023", "intro": "AMS G slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807220000020009", "intro": "Failed to extrude AMS-HT H Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1806210000020005", "intro": "AMS-HT G Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0500400000010040", "intro": "Cutting module Serial Number error" }, { "ecode": "0702700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1806720000020004", "intro": "Failed to pull back the AMS-HT G Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1802700000020002", "intro": "Failed to feed the AMS-HT C Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1804940000010001", "intro": "AMS-HT E The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "07FF810000010001", "intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose." }, { "ecode": "1807350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1201120000010003", "intro": "The AMS B Slot3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0701200000020018", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1802800000010002", "intro": "AMS-HT C The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1803630000020001", "intro": "The AMS-HT D Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1803210000020013", "intro": "AMS-HT D slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807020000010001", "intro": "AMS-HT H Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1203320000010001", "intro": "AMS D Slot 3 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0703210000010083", "intro": "Failed to read the filament information from AMS D slot 2. The RFID tag may be damaged." }, { "ecode": "0703210000020010", "intro": "AMS D slot 2 feeds filament out of AMS timeout." }, { "ecode": "0700230000020009", "intro": "Failed to extrude AMS A Slot 4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1806210000020021", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "180622000002000A", "intro": "Failed to adjust the filament position of AMS-HT G Slot 3. The filament or buffer may be stuck." }, { "ecode": "1801010000010004", "intro": "The AMS-HT B assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "0700220000030002", "intro": "AMS A Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0703220000020013", "intro": "AMS D slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1805700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1200310000020002", "intro": "The RFID-tag on AMS A Slot 2 is damaged." }, { "ecode": "0707200000030002", "intro": "AMS H Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0701940000010001", "intro": "AMS B The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0704220000020019", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1801210000020003", "intro": "AMS-HT B Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1807810000010004", "intro": "AMS-HT H The heater 2 is heating abnormally." }, { "ecode": "1807220000010082", "intro": "Failed to read the filament information from AMS-HT H slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "07FE800000020003", "intro": "The deviation in the positioning calibration value of the extruder is too large; please recalibrate." }, { "ecode": "0701200000020008", "intro": "AMS B Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0705230000020023", "intro": "AMS F slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1802220000020007", "intro": "AMS-HT C Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0706200000020016", "intro": "AMS G slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0705220000020011", "intro": "AMS F slot 3 pulls filament back to AMS timeout." }, { "ecode": "1804800000010001", "intro": "AMS-HT E The current sensor of heater 1 is abnormal." }, { "ecode": "1806230000010086", "intro": "Failed to read the filament information from AMS-HT G slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1804970000030001", "intro": "AMS-HT E chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "18FE810000010002", "intro": "The position hall sensor of the Extruder Switching Motor has an open circuit. Please check whether the connecting cable is loose." }, { "ecode": "1200220000020004", "intro": "AMS A Slot3 filament may be broken in the tool head." }, { "ecode": "0300260000010001", "intro": "The frequency of the extrusion force sensor of the left extruder is too low. The sensor may be installed too far, or the sensor may be loose." }, { "ecode": "0300C30000010003", "intro": "Current sensor of Automatic Top Vent malfunction: this may be due to open circuit or a hardware sampling circuit fault." }, { "ecode": "0707110000010003", "intro": "The AMS H slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0704560000030001", "intro": "AMS E is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0706900000020001", "intro": "AMS G The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "0C00020000020006", "intro": "Nozzle height seems to be too high. Please check if there is residual filament attached to the nozzle." }, { "ecode": "1807200000020024", "intro": "AMS-HT H slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200220000020006", "intro": "Failed to extrude AMS A Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1801200000020007", "intro": "AMS-HT B Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1802200000010085", "intro": "Failed to read the filament information from AMS-HT C slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0707230000020010", "intro": "AMS H slot 4 feeds filament out of AMS timeout." }, { "ecode": "1805010000010011", "intro": "AMS-HT F The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0705200000010082", "intro": "Failed to read the filament information from AMS F slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1802220000020018", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0704130000010003", "intro": "The AMS E slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1800230000030002", "intro": "AMS-HT A Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1804910000010003", "intro": "AMS-HT E The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1803210000020023", "intro": "AMS-HT D slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0300950000010007", "intro": "The engraving laser module is abnormal; the laser may have an open circuit or may be damaged." }, { "ecode": "0701230000010081", "intro": "Failed to read the filament information from AMS B slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1804200000020007", "intro": "AMS-HT E Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1801800000010003", "intro": "AMS-HT B The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0705210000010086", "intro": "Failed to read the filament information from AMS F slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0704810000010003", "intro": "AMS E The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0707220000020008", "intro": "AMS H Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701220000020017", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0700200000020016", "intro": "AMS A slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0707200000020016", "intro": "AMS H slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0706210000020017", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705120000010001", "intro": "The AMS F slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0500060000020031", "intro": "ToolHead Camera is not connected. Please check the hardware and cable connections." }, { "ecode": "12FF200000020001", "intro": "Filament at the spool holder has run out; please insert a new filament." }, { "ecode": "0702220000010081", "intro": "Failed to read the filament information from AMS C slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0700220000010081", "intro": "Failed to read the filament information from AMS A slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0702920000020002", "intro": "AMS C The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0300170000010001", "intro": "The hotend cooling fan speed is too slow or stopped. It may be stuck or the connector may not be plugged in properly." }, { "ecode": "1804220000020016", "intro": "AMS-HT E slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807240000020009", "intro": "AMS-HT H front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "0706810000010004", "intro": "AMS G The heater 2 is heating abnormally." }, { "ecode": "0701700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0701010000020008", "intro": "AMS B The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1800210000020012", "intro": "AMS-HT A slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800200000020013", "intro": "AMS-HT A slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700210000020015", "intro": "AMS A slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0C00040000010016", "intro": "Quick-release Lever is not locked. Please push it down to secure." }, { "ecode": "0700210000020005", "intro": "AMS A Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704940000010001", "intro": "AMS E The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "050004000002001C", "intro": "The RFID-tag on AMS D Slot1 cannot be identified." }, { "ecode": "1800300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1805910000010003", "intro": "AMS-HT F The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "0707210000030002", "intro": "AMS H Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700210000010086", "intro": "Failed to read the filament information from AMS A slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0700230000020019", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700200000020011", "intro": "AMS A slot 1 pulls filament back to AMS timeout." }, { "ecode": "1800810000010004", "intro": "AMS-HT A The heater 2 is heating abnormally." }, { "ecode": "1801010000010005", "intro": "AMS-HT B The current sensor of assist motor may be faulty." }, { "ecode": "0702810000010002", "intro": "AMS C The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1807210000010082", "intro": "Failed to read the filament information from AMS-HT H slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0705210000020019", "intro": "AMS F slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1807200000020001", "intro": "AMS-HT H Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1801200000020014", "intro": "AMS-HT B slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1805020000020002", "intro": "AMS-HT F The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "0707230000020021", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0704210000020017", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1806200000020012", "intro": "AMS-HT G slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800310000020002", "intro": "The RFID-tag on AMS-HT A Slot2 is damaged, or its content cannot be identified." }, { "ecode": "1802210000020019", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1807220000020002", "intro": "AMS-HT H Slot 3 is empty; please insert a new filament." }, { "ecode": "0700500000020001", "intro": "AMS A communication is abnormal; please check the connection cable." }, { "ecode": "1800550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0300030000010001", "intro": "The hotend cooling fan speed is too slow or stopped. It may be stuck or the connector may not be plugged in properly." }, { "ecode": "1802210000020012", "intro": "AMS-HT C slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704220000020018", "intro": "AMS E slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0C00010000020002", "intro": "Toolhead camera is malfunctioning. If this issue occurs multiple times during printing, please contact customer support." }, { "ecode": "1800110000020004", "intro": "AMS-HT A The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701960000010001", "intro": "AMS B The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0703700000020002", "intro": "Failed to feed the AMS D Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0700300000020002", "intro": "The RFID-tag on AMS A Slot1 is damaged, or its content cannot be identified." }, { "ecode": "0704230000020011", "intro": "AMS E slot 4 pulls filament back to AMS timeout." }, { "ecode": "0705010000020010", "intro": "AMS F The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "0705200000010086", "intro": "Failed to read the filament information from AMS F slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0704200000010081", "intro": "Failed to read the filament information from AMS E slot 1. The AMS main board may be malfunctioning." }, { "ecode": "0701230000010083", "intro": "Failed to read the filament information from AMS B slot 4. The RFID tag may be damaged." }, { "ecode": "0704220000010085", "intro": "Failed to read the filament information from AMS E slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1202100000010003", "intro": "The AMS C Slot1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0702200000020005", "intro": "AMS C Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1201130000020002", "intro": "The AMS B Slot4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0707200000010081", "intro": "Failed to read the filament information from AMS H slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1802310000010004", "intro": "Encryption chip failure" }, { "ecode": "1202220000020003", "intro": "AMS C Slot3 filament may be broken in the PTFE tube." }, { "ecode": "0707220000020017", "intro": "AMS H slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705220000020017", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0702200000020022", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0703220000020003", "intro": "AMS D Slot 3's filament may be broken in AMS." }, { "ecode": "0706230000020008", "intro": "AMS G Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701800000010002", "intro": "AMS B The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "03001B0000010001", "intro": "The signal of the heatbed acceleration sensor is weak. The sensor may have fallen off or been damaged." }, { "ecode": "1203210000020002", "intro": "AMS D Slot 2 is empty; please insert a new filament." }, { "ecode": "1802210000020005", "intro": "AMS-HT C Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0700210000020022", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0701220000020024", "intro": "AMS B slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807210000030002", "intro": "AMS-HT H Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704230000020013", "intro": "AMS E slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1201220000020006", "intro": "Failed to extrude AMS B Slot3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807210000020004", "intro": "AMS-HT H Slot 2 filament may be broken in the tool head." }, { "ecode": "1800210000020016", "intro": "AMS-HT A slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "07FF810000010002", "intro": "The position hall sensor of the Extruder Switching Motor has an open circuit. Please check whether the connecting cable is loose." }, { "ecode": "1806200000020024", "intro": "AMS-HT G slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802220000020008", "intro": "AMS-HT C Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1201100000020002", "intro": "The AMS B Slot1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805560000030001", "intro": "AMS-HT F is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0700220000020004", "intro": "AMS A Slot 3 filament may be broken in the tool head." }, { "ecode": "03009B0000010001", "intro": "Emergency stop button is not installed. Please follow the Wiki to install it." }, { "ecode": "1800210000020014", "intro": "AMS-HT A slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705950000010001", "intro": "AMS F The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1801210000020018", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0702210000020019", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0702010000010003", "intro": "The AMS C assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1201230000020005", "intro": "AMS B Slot4 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0704220000020005", "intro": "AMS E Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1803110000010001", "intro": "The AMS-HT D slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1801300000010001", "intro": "The AMS-HT B RFID 1 board has an error." }, { "ecode": "0700010000010004", "intro": "The AMS A assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1803220000020009", "intro": "Failed to extrude AMS-HT D Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800550000010004", "intro": "The binding between AMS-HT A and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "07FE800000010006", "intro": "The TH board disconnected during the extruder switching process. Please check if the connecting cable is loose." }, { "ecode": "1802220000010084", "intro": "Failed to read the filament information from AMS-HT C slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0701300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0703120000020002", "intro": "The AMS D slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704210000020002", "intro": "AMS E Slot 2 is empty; please insert a new filament." }, { "ecode": "0707200000020003", "intro": "AMS H Slot 1's filament may be broken in AMS." }, { "ecode": "07FE200000020002", "intro": "No filament was detected in the left extruder from the external spool; please load the new filament." }, { "ecode": "1802200000020008", "intro": "AMS-HT C Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1804600000020001", "intro": "The AMS-HT E Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1801210000010081", "intro": "Failed to read the filament information from AMS-HT B slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0500020000020001", "intro": "Failed to connect to the internet. Please check the network connection." }, { "ecode": "1805200000010086", "intro": "Failed to read the filament information from AMS-HT F slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0703220000020023", "intro": "AMS D slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "07FF810000020001", "intro": "The extruder switching action is abnormal. Please check whether there is something stuck in the toolhead." }, { "ecode": "1807700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1802550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "1201310000020002", "intro": "The RFID-tag on AMS B Slot 2 is damaged." }, { "ecode": "1807230000020017", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0704120000020004", "intro": "AMS E The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1801200000020022", "intro": "AMS-HT B slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0705200000020008", "intro": "AMS F Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800210000020019", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0705200000020014", "intro": "AMS F slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0703610000020001", "intro": "The AMS D Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1804350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "0300930000010004", "intro": "Chamber temperature is abnormal. The chamber heater's temperature sensor at the air outlet may have an open circuit." }, { "ecode": "1802230000010086", "intro": "Failed to read the filament information from AMS-HT C slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1805210000020024", "intro": "AMS-HT F slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0700700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0701100000010001", "intro": "The AMS B slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707220000020003", "intro": "AMS H Slot 3's filament may be broken in AMS." }, { "ecode": "0703210000020015", "intro": "AMS D slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1804230000020004", "intro": "AMS-HT E Slot 4 filament may be broken in the tool head." }, { "ecode": "0701200000020019", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1803930000010001", "intro": "AMS-HT D The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0705200000020010", "intro": "AMS F slot 1 feeds filament out of AMS timeout." }, { "ecode": "0707700000020002", "intro": "Failed to feed the AMS H Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0707010000020007", "intro": "AMS H The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0706230000020019", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1806700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1800010000020008", "intro": "AMS-HT A The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1803220000020022", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0706110000020002", "intro": "The AMS G slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1806010000020007", "intro": "AMS-HT G The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0703210000020008", "intro": "AMS D Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1806300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0707210000010083", "intro": "Failed to read the filament information from AMS H slot 2. The RFID tag may be damaged." }, { "ecode": "0C00040000020008", "intro": "Material not detected. Please confirm placement and continue." }, { "ecode": "1801710000020001", "intro": "Failed to pull out the AMS-HT B Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0705200000020012", "intro": "AMS F slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0700230000020003", "intro": "AMS A Slot 4's filament may be broken in AMS." }, { "ecode": "1807010000020009", "intro": "AMS-HT H The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0702200000010084", "intro": "Failed to read the filament information from AMS C slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706230000020024", "intro": "AMS G slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0500050000010001", "intro": "The factory data of the AP board is abnormal; please replace the AP board with a new one." }, { "ecode": "1805210000010084", "intro": "Failed to read the filament information from AMS-HT F slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1806230000020011", "intro": "AMS-HT G slot 4 pulls filament back to AMS timeout." }, { "ecode": "0703210000020017", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1802200000020012", "intro": "AMS-HT C slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1802810000010004", "intro": "AMS-HT C The heater 2 is heating abnormally." }, { "ecode": "1200720000010001", "intro": "AMS A Filament speed and length error: The slot 3 filament odometry may be faulty." }, { "ecode": "0705220000010086", "intro": "Failed to read the filament information from AMS F slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0700010000020002", "intro": "The AMS A assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0700210000020008", "intro": "AMS A Slot 2 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1806700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1803210000020003", "intro": "AMS-HT D Slot 2's filament may be broken in AMS-HT." }, { "ecode": "0500040000020050", "intro": "Laser Safety Window is not installed." }, { "ecode": "1806220000020011", "intro": "AMS-HT G slot 3 pulls filament back to AMS timeout." }, { "ecode": "1802200000020009", "intro": "Failed to extrude AMS-HT C Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0707230000010084", "intro": "Failed to read the filament information from AMS H slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1807010000010011", "intro": "AMS-HT H The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1802210000020007", "intro": "AMS-HT C Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0706710000020004", "intro": "Failed to pull back the AMS G Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800230000020021", "intro": "AMS-HT A slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801200000020008", "intro": "AMS-HT B Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704230000020004", "intro": "AMS E Slot 4 filament may be broken in the tool head." }, { "ecode": "0500040000020043", "intro": "The Toolhead Camera is dirty or obstructed; please clean it and continue." }, { "ecode": "0703910000010003", "intro": "AMS D The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "0702230000010084", "intro": "Failed to read the filament information from AMS C slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0700800000010002", "intro": "AMS A The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0707230000020007", "intro": "AMS H Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0701100000020004", "intro": "AMS B The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806310000010001", "intro": "The AMS-HT G RFID 2 board has an error." }, { "ecode": "0702230000020015", "intro": "AMS C slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0703320000020002", "intro": "The RFID-tag on AMS D Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0702220000020022", "intro": "AMS C slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0706220000020007", "intro": "AMS G Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1806210000020004", "intro": "AMS-HT G Slot 2 filament may be broken in the tool head." }, { "ecode": "1803110000020002", "intro": "The AMS-HT D slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704200000030001", "intro": "AMS E Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1801230000020016", "intro": "AMS-HT B slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0500060000020041", "intro": "" }, { "ecode": "1807220000020023", "intro": "AMS-HT H slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1804220000020024", "intro": "AMS-HT E slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "070720000002000A", "intro": "Failed to adjust the filament position of AMS H Slot 1. The filament or buffer may be stuck." }, { "ecode": "0701810000010003", "intro": "AMS B The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0300920000010001", "intro": "The temperature of chamber heater 2 is abnormal. The heater may have a short circuit." }, { "ecode": "0700210000020009", "intro": "Failed to extrude AMS A Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0705230000020008", "intro": "AMS F Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0704210000020024", "intro": "AMS E slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1201210000020002", "intro": "AMS B Slot 2 is empty; please insert a new filament." }, { "ecode": "1807230000010081", "intro": "Failed to read the filament information from AMS-HT H slot 4. The AMS main board may be malfunctioning." }, { "ecode": "18FE800000010001", "intro": "The toolhead lift motor works abnormally. Please check whether the connecting cable is loose." }, { "ecode": "0704230000020017", "intro": "AMS E slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1202300000030003", "intro": "AMS C Slot1 RFID cannot be read because of a structural error." }, { "ecode": "1802220000020015", "intro": "AMS-HT C slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1804960000010003", "intro": "AMS-HT E Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "0706800000010004", "intro": "AMS G The heater 1 is heating abnormally." }, { "ecode": "1801310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1807010000010001", "intro": "The AMS-HT H assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0707230000010083", "intro": "Failed to read the filament information from AMS H slot 4. The RFID tag may be damaged." }, { "ecode": "1802320000020002", "intro": "The RFID-tag on AMS-HT C Slot3 is damaged, or its content cannot be identified." }, { "ecode": "0701210000020023", "intro": "AMS B slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0701300000010004", "intro": "Encryption chip failure" }, { "ecode": "0705220000020022", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1802960000020002", "intro": "AMS-HT C Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0704220000020003", "intro": "AMS E Slot 3's filament may be broken in AMS." }, { "ecode": "0702200000010086", "intro": "Failed to read the filament information from AMS C slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "18FF800000010003", "intro": "The hall signal of the Toolhead Lifting Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "1806210000020009", "intro": "Failed to extrude AMS-HT G Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1807200000020003", "intro": "AMS-HT H Slot 1's filament may be broken in AMS-HT." }, { "ecode": "0706220000010081", "intro": "Failed to read the filament information from AMS G slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0700910000020001", "intro": "AMS A The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1201120000010001", "intro": "The AMS B Slot3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1800310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1806210000010084", "intro": "Failed to read the filament information from AMS-HT G slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1804620000020001", "intro": "The AMS-HT E Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806910000020001", "intro": "AMS-HT G The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "0701230000030001", "intro": "AMS B Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1805210000020013", "intro": "AMS-HT F slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700550000010004", "intro": "The binding between AMS A and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "070321000002000A", "intro": "Failed to adjust the filament position of AMS D Slot 2. The filament or buffer may be stuck." }, { "ecode": "0300260000000000", "intro": "" }, { "ecode": "0706200000020012", "intro": "AMS G slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0702900000010002", "intro": "AMS C The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1802700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0700230000010085", "intro": "Failed to read the filament information from AMS A slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0702220000020024", "intro": "AMS C slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0500030000010008", "intro": "A system hang occurred. Please restart the device." }, { "ecode": "1201310000010001", "intro": "AMS B Slot 2 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1804010000010003", "intro": "The AMS-HT E assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1800210000010081", "intro": "Failed to read the filament information from AMS-HT A slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1203210000020006", "intro": "Failed to extrude AMS D Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "12FF200000020005", "intro": "Filament may be broken in the tool head." }, { "ecode": "0700230000020011", "intro": "AMS A slot 4 pulls filament back to AMS timeout." }, { "ecode": "1800210000020007", "intro": "AMS-HT A Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0701250000020001", "intro": "AMS B uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0705220000010082", "intro": "Failed to read the filament information from AMS F slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1800700000020005", "intro": "Failed to feed the AMS-HT A Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0701220000020020", "intro": "AMS B slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1804200000020023", "intro": "AMS-HT E slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0700200000020024", "intro": "AMS A slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1803220000020016", "intro": "AMS-HT D slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807100000010001", "intro": "The AMS-HT H slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1807200000010085", "intro": "Failed to read the filament information from AMS-HT H slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0700230000020001", "intro": "AMS A Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1803130000020004", "intro": "AMS-HT D The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804710000020001", "intro": "Failed to pull out the AMS-HT E Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0702200000020002", "intro": "AMS C Slot 1 is empty; please insert a new filament." }, { "ecode": "1801100000010001", "intro": "The AMS-HT B slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0701230000020024", "intro": "AMS B slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200220000020003", "intro": "AMS A Slot3 filament may be broken in the PTFE tube." }, { "ecode": "0704720000020001", "intro": "Failed to pull out the AMS E Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1805710000020005", "intro": "Failed to feed the AMS-HT F Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0700010000010011", "intro": "AMS A The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0704230000020016", "intro": "AMS E slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0702810000010003", "intro": "AMS C The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1806200000020017", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0300C10000010002", "intro": "Airflow System failed to activate heating mode; please check the air door status." }, { "ecode": "0500040000020018", "intro": "The RFID-tag on AMS C Slot1 cannot be identified." }, { "ecode": "1800230000010085", "intro": "Failed to read the filament information from AMS-HT A slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1802210000010082", "intro": "Failed to read the filament information from AMS-HT C slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0706920000010001", "intro": "AMS G The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1806230000020008", "intro": "AMS-HT G Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1804710000020004", "intro": "Failed to pull back the AMS-HT E Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701230000020008", "intro": "AMS B Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1800210000020003", "intro": "AMS-HT A Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1800210000020021", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0703810000010003", "intro": "AMS D The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1801220000020020", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1803010000010004", "intro": "The AMS-HT D assist motor speed control is malfunctioning. The speed sensor may be faulty." }, { "ecode": "1804220000020003", "intro": "AMS-HT E Slot 3's filament may be broken in AMS-HT." }, { "ecode": "1807700000020002", "intro": "Failed to feed the AMS-HT H Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805100000010001", "intro": "The AMS-HT F slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1806230000010081", "intro": "Failed to read the filament information from AMS-HT G slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1806960000010001", "intro": "AMS-HT G The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "1203300000020002", "intro": "The RFID-tag on AMS D Slot 1 is damaged." }, { "ecode": "12FF800000020001", "intro": "The filament on the spool holder may be tangled or stuck." }, { "ecode": "1201320000030003", "intro": "AMS B Slot3 RFID cannot be read because of a structural error." }, { "ecode": "0704220000020014", "intro": "AMS E slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0500040000020013", "intro": "The RFID-tag on AMS A Slot4 cannot be identified." }, { "ecode": "0701230000010082", "intro": "Failed to read the filament information from AMS B slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0702720000020004", "intro": "Failed to pull back the AMS C Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0701810000010004", "intro": "AMS B The heater 2 is heating abnormally." }, { "ecode": "0582050000010010", "intro": "The firmware of AMS-HT C does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1201200000030002", "intro": "AMS B Slot1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1801300000010004", "intro": "Encryption chip failure" }, { "ecode": "1807210000020007", "intro": "AMS-HT H Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0707720000020004", "intro": "Failed to pull back the AMS H Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0703200000010082", "intro": "Failed to read the filament information from AMS D slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "070623000002000A", "intro": "Failed to adjust the filament position of AMS G Slot 4. The filament or buffer may be stuck." }, { "ecode": "0707120000010003", "intro": "The AMS H slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804720000020005", "intro": "Failed to feed the AMS-HT E Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1806930000010001", "intro": "AMS-HT G The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "1807930000020002", "intro": "AMS-HT H The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1800210000020024", "intro": "AMS-HT A slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1803200000020016", "intro": "AMS-HT D slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "18FF810000010003", "intro": "The hall signal of the Extruder Switching Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "1800200000020014", "intro": "AMS-HT A slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1804300000010004", "intro": "Encryption chip failure" }, { "ecode": "1804730000020005", "intro": "Failed to feed the AMS-HT E Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1802620000020001", "intro": "The AMS-HT C Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1807230000010084", "intro": "Failed to read the filament information from AMS-HT H slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0704710000020004", "intro": "Failed to pull back the AMS E Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1806200000020006", "intro": "AMS-HT G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "03001E0000010002", "intro": "The left nozzle temperature is abnormal; the heater may have an open circuit." }, { "ecode": "0700550000020001", "intro": "A new AMS detected. Please set it up to check which extruder the AMS is connected to." }, { "ecode": "1802730000020001", "intro": "Failed to pull out the AMS-HT C Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0707920000020002", "intro": "AMS H The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "0702220000020008", "intro": "AMS C Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0700800000010001", "intro": "AMS A The current sensor of heater 1 is abnormal." }, { "ecode": "1805210000020017", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0704230000020008", "intro": "AMS E Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1201330000010001", "intro": "AMS B Slot 4 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0707200000010084", "intro": "Failed to read the filament information from AMS H slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1805730000020004", "intro": "Failed to pull back the AMS-HT F Slot 4 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702810000010004", "intro": "AMS C The heater 2 is heating abnormally." }, { "ecode": "1800010000020007", "intro": "AMS-HT A The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1202230000030002", "intro": "AMS C Slot4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1802800000010001", "intro": "AMS-HT C The current sensor of heater 1 is abnormal." }, { "ecode": "0701730000020001", "intro": "Failed to pull out the AMS B Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0300110000020001", "intro": "The resonance frequency of the Y axis is low. The timing belt may be loose." }, { "ecode": "0300150000010001", "intro": "The current sensor of Motor-Z is abnormal. This may be caused by a failure of the hardware sampling circuit." }, { "ecode": "0702720000020002", "intro": "Failed to feed the AMS C Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805230000020005", "intro": "AMS-HT F Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0705620000020001", "intro": "The AMS F Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800720000020001", "intro": "Failed to pull out the AMS-HT A Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0703130000020004", "intro": "AMS D The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0707300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1806210000010081", "intro": "Failed to read the filament information from AMS-HT G slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1803810000010004", "intro": "AMS-HT D The heater 2 is heating abnormally." }, { "ecode": "1801220000020003", "intro": "AMS-HT B Slot 3's filament may be broken in AMS-HT." }, { "ecode": "1202500000020001", "intro": "AMS C communication is abnormal; please check the connection cable." }, { "ecode": "0702210000020007", "intro": "AMS C Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0300200000010002", "intro": "Y-axis homing abnormal: please check if the toolhead is stuck or the Y carriage has too much resistance." }, { "ecode": "0703010000010003", "intro": "The AMS D assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804630000020001", "intro": "The AMS-HT E Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806230000020012", "intro": "AMS-HT G slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1805130000010001", "intro": "The AMS-HT F slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "180223000002000A", "intro": "Failed to adjust the filament position of AMS-HT C Slot 4. The filament or buffer may be stuck." }, { "ecode": "0C00040000020004", "intro": "The type of platform is not supported for this task. Please use the correct platform to continue." }, { "ecode": "0702200000010082", "intro": "Failed to read the filament information from AMS C slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0706220000020021", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802210000020001", "intro": "AMS-HT C Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0701120000020002", "intro": "The AMS B slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706200000020018", "intro": "AMS G slot 1 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1203300000010001", "intro": "AMS D Slot 1 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0300250000010003", "intro": "Unable to read data from the right extruder force sensor; there may be a communication break or sensor damage." }, { "ecode": "18FF700000020003", "intro": "Please check if the material is coming out of the right nozzle. If not, gently push the material and try to extrude again." }, { "ecode": "0706120000020002", "intro": "The AMS G slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1806200000020001", "intro": "AMS-HT G Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "1801230000020015", "intro": "AMS-HT B slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0583050000010010", "intro": "The firmware of AMS-HT D does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0701200000020023", "intro": "AMS B slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0700200000010084", "intro": "Failed to read the filament information from AMS A slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0701220000010082", "intro": "Failed to read the filament information from AMS B slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0701700000020001", "intro": "Failed to pull out the AMS B Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1800220000030001", "intro": "AMS-HT A Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "18FE700000020003", "intro": "Please check if the material is coming out of the left nozzle. If not, gently push the material and try to extrude again." }, { "ecode": "0701200000020007", "intro": "AMS B Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1801810000010004", "intro": "AMS-HT B The heater 2 is heating abnormally." }, { "ecode": "1802210000020010", "intro": "AMS-HT C slot 2 feeds filament out of AMS timeout." }, { "ecode": "1800710000020001", "intro": "Failed to pull out the AMS-HT A Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0707200000020009", "intro": "Failed to extrude AMS H Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0703710000020005", "intro": "Failed to feed the AMS D Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0C00010000020015", "intro": "" }, { "ecode": "0702010000020009", "intro": "AMS C The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "1800920000020002", "intro": "AMS-HT A The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "1803500000020001", "intro": "AMS-HT D communication is abnormal; please check the connection cable." }, { "ecode": "1804220000010084", "intro": "Failed to read the filament information from AMS-HT E slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1805600000020001", "intro": "The AMS-HT F Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702910000010003", "intro": "AMS C The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1805700000020005", "intro": "Failed to feed the AMS-HT F Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1807110000020004", "intro": "AMS-HT H The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0701810000010001", "intro": "AMS B The current sensor of heater 2 is abnormal." }, { "ecode": "0700220000020013", "intro": "AMS A slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806220000010083", "intro": "Failed to read the filament information from AMS-HT G slot 3. The RFID tag may be damaged." }, { "ecode": "1803210000020018", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1202220000020001", "intro": "AMS C Slot3 filament has run out; please insert a new filament." }, { "ecode": "0706940000010001", "intro": "AMS G The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0707220000020005", "intro": "AMS H Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "03000B0000010001", "intro": "Heatbed force sensor 2 is too sensitive. It may be stuck between the strain arm and heatbed support, or the adjusting screw may be too tight." }, { "ecode": "0701110000020002", "intro": "The AMS B slot 2 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "0300410000010001", "intro": "The system voltage is unstable. Triggering the power failure protection function." }, { "ecode": "1807220000020024", "intro": "AMS-HT H slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0701310000010001", "intro": "The AMS B RFID 2 board has an error." }, { "ecode": "0707230000020017", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1800120000020004", "intro": "AMS-HT A The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806200000020022", "intro": "AMS-HT G slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0702720000020001", "intro": "Failed to pull out the AMS C Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0700230000020022", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0705200000020021", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0700220000020012", "intro": "AMS A slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1801200000020011", "intro": "AMS-HT B slot 1 pulls filament back to AMS timeout." }, { "ecode": "1805230000030002", "intro": "AMS-HT F Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704230000020003", "intro": "AMS E Slot 4's filament may be broken in AMS." }, { "ecode": "1805230000020024", "intro": "AMS-HT F slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1807900000010002", "intro": "AMS-HT H The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0705700000020002", "intro": "Failed to feed the AMS F Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0300A40000010001", "intro": "Heatbed temperature is too high. Please wait for it to cool down to room temperature before restarting the task." }, { "ecode": "0706200000030001", "intro": "AMS G Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0704970000030001", "intro": "AMS E chamber temperature is too high; auxiliary feeding or RFID reading is currently not allowed." }, { "ecode": "1807200000020017", "intro": "AMS-HT H slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1806020000010001", "intro": "AMS-HT G Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "1805200000020003", "intro": "AMS-HT F Slot 1's filament may be broken in AMS-HT." }, { "ecode": "0707210000020010", "intro": "AMS H slot 2 feeds filament out of AMS timeout." }, { "ecode": "0702220000020011", "intro": "AMS C slot 3 pulls filament back to AMS timeout." }, { "ecode": "1801200000020010", "intro": "AMS-HT B slot 1 feeds filament out of AMS timeout." }, { "ecode": "1804110000020004", "intro": "AMS-HT E The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0300950000010002", "intro": "The temperature sensor of the Laser Module may have an open circuit." }, { "ecode": "1802910000010003", "intro": "AMS-HT C The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1803210000020014", "intro": "AMS-HT D slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0701210000020024", "intro": "AMS B slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0703350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1807550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0703220000030001", "intro": "AMS D Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0705700000020004", "intro": "Failed to pull back the AMS F Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800200000010086", "intro": "Failed to read the filament information from AMS-HT A slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1806560000030001", "intro": "AMS-HT G is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "1801220000020009", "intro": "Failed to extrude AMS-HT B Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1801210000020017", "intro": "AMS-HT B slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0700900000010003", "intro": "AMS A The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "1803220000020015", "intro": "AMS-HT D slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1200200000020001", "intro": "AMS A Slot1 filament has run out; please insert a new filament." }, { "ecode": "1803230000020007", "intro": "AMS-HT D Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1801010000020010", "intro": "AMS-HT B The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1804010000010011", "intro": "AMS-HT E The assist motor calibration parameter error. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1804900000010003", "intro": "AMS-HT E The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0700220000020017", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0707200000010083", "intro": "Failed to read the filament information from AMS H slot 1. The RFID tag may be damaged." }, { "ecode": "1203700000010001", "intro": "AMS D Filament speed and length error: The slot 1 filament odometry may be faulty." }, { "ecode": "0700210000020002", "intro": "AMS A Slot 2 is empty; please insert a new filament." }, { "ecode": "1805210000020010", "intro": "AMS-HT F slot 2 feeds filament out of AMS timeout." }, { "ecode": "0705200000030002", "intro": "AMS F Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704220000020008", "intro": "AMS E Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0702960000020002", "intro": "AMS C Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1806210000020007", "intro": "AMS-HT G Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0C00010000020014", "intro": "Nozzle Camera is malfunctioning. If this issue occurs multiple times during printing, please contact customer support." }, { "ecode": "0703920000010001", "intro": "AMS D The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1805230000020007", "intro": "AMS-HT F Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1807200000020004", "intro": "AMS-HT H Slot 1 filament may be broken in the tool head." }, { "ecode": "0705200000020004", "intro": "AMS F Slot 1 filament may be broken in the tool head." }, { "ecode": "1804200000020008", "intro": "AMS-HT E Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0300180000010006", "intro": "The heatbed leveling data is abnormal. Please check whether there are any foreign objects on the heatbed and Z slider. If so, please remove them and try again." }, { "ecode": "1806210000020018", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0701210000020005", "intro": "AMS B Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1805230000010082", "intro": "Failed to read the filament information from AMS-HT F slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1804930000020002", "intro": "AMS-HT E The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1201300000010001", "intro": "AMS B Slot 1 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "0703710000020002", "intro": "Failed to feed the AMS D Slot 2 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1801220000020007", "intro": "AMS-HT B Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1202310000010001", "intro": "AMS C Slot 2 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1802300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "1807220000020021", "intro": "AMS-HT H slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1801200000020004", "intro": "AMS-HT B Slot 1 filament may be broken in the tool head." }, { "ecode": "1802210000020002", "intro": "AMS-HT C Slot 2 is empty; please insert a new filament." }, { "ecode": "03009B0000010003", "intro": "Emergency Stop Button is not in the right position. Please follow the Wiki to install it." }, { "ecode": "0703010000020010", "intro": "AMS D The assist motor resistance is abnormal. The assist motor may be faulty." }, { "ecode": "1804210000020017", "intro": "AMS-HT E slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "07FE200000020001", "intro": "External filament of left extruder has run out; please load a new filament." }, { "ecode": "0700200000020017", "intro": "AMS A slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1800960000010001", "intro": "AMS-HT A The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0705700000020005", "intro": "Failed to feed the AMS F Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0706200000020013", "intro": "AMS G slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704230000010085", "intro": "Failed to read the filament information from AMS E slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1806620000020001", "intro": "The AMS-HT G Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800220000020009", "intro": "Failed to extrude AMS-HT A Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1804120000020002", "intro": "The AMS-HT E slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803130000020002", "intro": "The AMS-HT D slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0300270000010004", "intro": "The signal of the nozzle offset calibration sensor is abnormal. The sensor may be damaged, or the wiring may not be connected properly." }, { "ecode": "1803800000010004", "intro": "AMS-HT D The heater 1 is heating abnormally." }, { "ecode": "1806220000010085", "intro": "Failed to read the filament information from AMS-HT G slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1806550000010003", "intro": "AMS-HT G was detected offline during the AMS initialization process." }, { "ecode": "0705230000030001", "intro": "AMS F Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0707210000020012", "intro": "AMS H slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0705710000020004", "intro": "Failed to pull back the AMS F Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0706200000020001", "intro": "AMS G Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0703130000010003", "intro": "The AMS D slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0300900000010004", "intro": "Chamber heating failed. The speed of the heating fan is too low." }, { "ecode": "1201110000010001", "intro": "The AMS B Slot2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1807220000020011", "intro": "AMS-HT H slot 3 pulls filament back to AMS timeout." }, { "ecode": "1804200000020002", "intro": "AMS-HT E Slot 1 is empty; please insert a new filament." }, { "ecode": "1202200000020001", "intro": "AMS C Slot1 filament has run out; please insert a new filament." }, { "ecode": "0703230000020022", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0700560000030001", "intro": "AMS A is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0702210000020022", "intro": "AMS C slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1803210000020011", "intro": "AMS-HT D slot 2 pulls filament back to AMS timeout." }, { "ecode": "0700210000020017", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0702200000020017", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1800700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1803230000020024", "intro": "AMS-HT D slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1803220000020014", "intro": "AMS-HT D slot 3 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704210000020013", "intro": "AMS E slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802100000010001", "intro": "The AMS-HT C slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1801200000020023", "intro": "AMS-HT B slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0704900000020001", "intro": "AMS E The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1203730000010001", "intro": "AMS D Filament speed and length error: The slot 4 filament odometry may be faulty." }, { "ecode": "0300C00000010001", "intro": "Active Chamber Exhaust air door malfunction: it may be stuck." }, { "ecode": "1806100000020004", "intro": "AMS-HT G The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0706230000020007", "intro": "AMS G Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0700960000010001", "intro": "AMS A The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "070020000002000A", "intro": "Failed to adjust the filament position of AMS A Slot 1. The filament or buffer may be stuck." }, { "ecode": "07FF600000020001", "intro": "External spool connected to right extruder may be tangled or jammed." }, { "ecode": "03009B0000010002", "intro": "Safety key is not inserted. Please follow the Wiki to install it." }, { "ecode": "0702210000010081", "intro": "Failed to read the filament information from AMS C slot 2. The AMS main board may be malfunctioning." }, { "ecode": "0707230000020014", "intro": "AMS H slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705200000020017", "intro": "AMS F slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0704200000020004", "intro": "AMS E Slot 1 filament may be broken in the tool head." }, { "ecode": "0707220000030001", "intro": "AMS H Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1203210000020003", "intro": "AMS D Slot2 filament may be broken in the PTFE tube." }, { "ecode": "0705200000020006", "intro": "AMS F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0704210000010084", "intro": "Failed to read the filament information from AMS E slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0705210000030001", "intro": "AMS F Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1201730000010001", "intro": "AMS B Filament speed and length error: The slot 4 filament odometry may be faulty." }, { "ecode": "1801700000020005", "intro": "Failed to feed the AMS-HT B Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0703710000020004", "intro": "Failed to pull back the AMS D Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0706900000010003", "intro": "AMS G The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0500010000030007", "intro": "Unable to record time-lapse photography without USB flash drive inserted." }, { "ecode": "0300990000010004", "intro": "The Right Laser Safety Window is not detected. Please install it according to the Wiki and re-initiate the task." }, { "ecode": "1202320000030003", "intro": "AMS C Slot3 RFID cannot be read because of a structural error." }, { "ecode": "1804210000020012", "intro": "AMS-HT E slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0707900000010002", "intro": "AMS H The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0700220000020010", "intro": "AMS A slot 3 feeds filament out of AMS timeout." }, { "ecode": "1802500000020001", "intro": "AMS-HT C communication is abnormal; please check the connection cable." }, { "ecode": "0707210000020017", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1802220000030002", "intro": "AMS-HT C Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1802930000010001", "intro": "AMS-HT C The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0704720000020005", "intro": "Failed to feed the AMS E Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0705110000010001", "intro": "The AMS F slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "03000A0000010005", "intro": "Force sensor 1 detected unexpected continuous force. The heatbed may be stuck, or the analog front end may be broken." }, { "ecode": "1806220000020017", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1806010000020006", "intro": "AMS-HT G The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0706230000030002", "intro": "AMS G Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1804120000010003", "intro": "The AMS-HT E slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1801310000020002", "intro": "The RFID-tag on AMS-HT B Slot2 is damaged, or its content cannot be identified." }, { "ecode": "1802310000020002", "intro": "The RFID-tag on AMS-HT C Slot2 is damaged, or its content cannot be identified." }, { "ecode": "180721000002000A", "intro": "Failed to adjust the filament position of AMS-HT H Slot 2. The filament or buffer may be stuck." }, { "ecode": "0700910000010002", "intro": "AMS A The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0300C30000010002", "intro": "Current sensor of Filter Switch Flap malfunction: this may be due to an open circuit or a hardware sampling circuit fault." }, { "ecode": "0704210000020011", "intro": "AMS E slot 2 pulls filament back to AMS timeout." }, { "ecode": "1804210000020004", "intro": "AMS-HT E Slot 2 filament may be broken in the tool head." }, { "ecode": "1803020000020002", "intro": "AMS-HT D The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1805200000020015", "intro": "AMS-HT F slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0706010000020008", "intro": "AMS G The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "0705220000020001", "intro": "AMS F Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0705220000020019", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0700930000010001", "intro": "AMS A The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "1802130000010003", "intro": "The AMS-HT C slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0703200000020012", "intro": "AMS D slot 1 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0701960000020002", "intro": "AMS B Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "0707910000010002", "intro": "AMS H The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0704210000020009", "intro": "Failed to extrude AMS E Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0300160000010001", "intro": "The extruder servo motor's current sensor is abnormal. A failure of the hardware sampling circuit may cause this." }, { "ecode": "1802720000020001", "intro": "Failed to pull out the AMS-HT C Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701220000020005", "intro": "AMS B Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0700210000020024", "intro": "AMS A slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802200000010086", "intro": "Failed to read the filament information from AMS-HT C slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0701220000030001", "intro": "AMS B Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "0706200000020024", "intro": "AMS G slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1806200000010081", "intro": "Failed to read the filament information from AMS-HT G slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1803200000010084", "intro": "Failed to read the filament information from AMS-HT D slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0705710000020005", "intro": "Failed to feed the AMS F Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "03001E0000010001", "intro": "The left nozzle temperature is abnormal; the heater may have a short circuit." }, { "ecode": "0700230000020013", "intro": "AMS A slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700700000020005", "intro": "Failed to feed the AMS A Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1805220000020016", "intro": "AMS-HT F slot 3 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0705220000020024", "intro": "AMS F slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802200000020007", "intro": "AMS-HT C Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0702210000020002", "intro": "AMS C Slot 2 is empty; please insert a new filament." }, { "ecode": "1800220000010081", "intro": "Failed to read the filament information from AMS-HT A slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1800930000020002", "intro": "AMS-HT A The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "0500040000030009", "intro": "The bed temperature exceeds filament's vitrification temperature, which may cause nozzle clog. Please keep the front door of the printer open. Door open detection has been temporarily turned off." }, { "ecode": "0703230000010081", "intro": "Failed to read the filament information from AMS D slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1801930000010001", "intro": "AMS-HT B The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "0701910000010003", "intro": "AMS B The exhaust valve 2 is not connected, which may be due to poor connector contact." }, { "ecode": "1801720000020005", "intro": "Failed to feed the AMS-HT B Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0702800000010002", "intro": "AMS C The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0500060000020044", "intro": "" }, { "ecode": "1806220000010086", "intro": "Failed to read the filament information from AMS-HT G slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0701220000010086", "intro": "Failed to read the filament information from AMS B slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1800010000020011", "intro": "AMS-HT A The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "1805240000010007", "intro": "AMS-HT F door detection is abnormal, the Hall sensor connection may be loose or disconnected." }, { "ecode": "0703230000020017", "intro": "AMS D slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0700200000020009", "intro": "Failed to extrude AMS A Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0701220000020002", "intro": "AMS B Slot 3 is empty; please insert a new filament." }, { "ecode": "0702210000020004", "intro": "AMS C Slot 2 filament may be broken in the tool head." }, { "ecode": "1802110000010001", "intro": "The AMS-HT C slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702020000020002", "intro": "AMS C The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1805210000020003", "intro": "AMS-HT F Slot 2's filament may be broken in AMS-HT." }, { "ecode": "1800200000010082", "intro": "Failed to read the filament information from AMS-HT A slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1807220000020004", "intro": "AMS-HT H Slot 3 filament may be broken in the tool head." }, { "ecode": "1800220000010084", "intro": "Failed to read the filament information from AMS-HT A slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0500040000020020", "intro": "" }, { "ecode": "0707220000010086", "intro": "Failed to read the filament information from AMS H slot 3. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "0702700000020004", "intro": "Failed to pull back the AMS C Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0300250000010008", "intro": "The right nozzle touches the heating bed abnormally. Please check whether there is filament residue on the nozzle or foreign matter where the nozzle touches the bed." }, { "ecode": "0703220000020021", "intro": "AMS D slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1805200000020004", "intro": "AMS-HT F Slot 1 filament may be broken in the tool head." }, { "ecode": "0300930000010008", "intro": "Chamber temperature is abnormal. The temperature sensor at power supply may have an open circuit." }, { "ecode": "0701710000020001", "intro": "Failed to pull out the AMS B Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701230000020013", "intro": "AMS B slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1200730000010001", "intro": "AMS A Filament speed and length error: The slot 4 filament odometry may be faulty." }, { "ecode": "0704620000020001", "intro": "The AMS E Slot 3 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0702200000020004", "intro": "AMS C Slot 1 filament may be broken in the tool head." }, { "ecode": "1800010000010005", "intro": "AMS-HT A The current sensor of assist motor may be faulty." }, { "ecode": "1804920000010001", "intro": "AMS-HT E The cooling fan of heater 1 is blocked, which may be due to the fan being stuck." }, { "ecode": "1802200000020022", "intro": "AMS-HT C slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0701200000010085", "intro": "Failed to read the filament information from AMS B slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1806800000010001", "intro": "AMS-HT G The current sensor of heater 1 is abnormal." }, { "ecode": "0701110000010001", "intro": "The AMS B slot 2 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0702600000020001", "intro": "The AMS C Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0704900000010002", "intro": "AMS E The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0704230000030001", "intro": "AMS E Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0705200000010084", "intro": "Failed to read the filament information from AMS F slot 1. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1801210000020001", "intro": "AMS-HT B Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0701130000020004", "intro": "AMS B The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0300C00000010002", "intro": "Filter Switch Flap air door malfunction: it may be stuck." }, { "ecode": "0703100000020004", "intro": "AMS D The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802950000010001", "intro": "AMS-HT C The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1807210000020015", "intro": "AMS-HT H slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1803230000020013", "intro": "AMS-HT D slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807900000010003", "intro": "AMS-HT H The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "1202200000030002", "intro": "AMS C Slot1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702220000020010", "intro": "AMS C slot 3 feeds filament out of AMS timeout." }, { "ecode": "1806230000020017", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0300250000010005", "intro": "Z-axis motor rotation is obstructed; please check if foreign objects are stuck in the Z slider or Z timing pulley. Also, ensure the build plate is placed correctly to avoid collisions with surrounding structures." }, { "ecode": "1803950000010001", "intro": "AMS-HT D The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1807810000010001", "intro": "AMS-HT H The current sensor of heater 2 is abnormal." }, { "ecode": "070021000002000A", "intro": "Failed to adjust the filament position of AMS A Slot 2. The filament or buffer may be stuck." }, { "ecode": "1800200000020011", "intro": "AMS-HT A slot 1 pulls filament back to AMS timeout." }, { "ecode": "0500030000020018", "intro": "" }, { "ecode": "0702200000020019", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "07FF200000020002", "intro": "No filament was detected in the right extruder from the external spool; please load the new filament." }, { "ecode": "1806900000020001", "intro": "AMS-HT G The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "1804910000020001", "intro": "AMS-HT E The operation of the exhaust valve 2 is abnormal, which may be due to excessive resistance." }, { "ecode": "1800220000020007", "intro": "AMS-HT A Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1803200000020021", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802210000020017", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1803230000010083", "intro": "Failed to read the filament information from AMS-HT D slot 4. The RFID tag may be damaged." }, { "ecode": "1802200000020003", "intro": "AMS-HT C Slot 1's filament may be broken in AMS-HT." }, { "ecode": "1807230000020018", "intro": "AMS-HT H slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0705210000020004", "intro": "AMS F Slot 2 filament may be broken in the tool head." }, { "ecode": "1807910000010002", "intro": "AMS-HT H The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0704700000020004", "intro": "Failed to pull back the AMS E Slot 1 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0702230000020017", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0703230000020014", "intro": "AMS D slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0705230000030002", "intro": "AMS F Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704010000020008", "intro": "AMS E The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1802210000030002", "intro": "AMS-HT C Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0705200000010081", "intro": "Failed to read the filament information from AMS F slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1807200000020010", "intro": "AMS-HT H slot 1 feeds filament out of AMS timeout." }, { "ecode": "1801220000020002", "intro": "AMS-HT B Slot 3 is empty; please insert a new filament." }, { "ecode": "1806220000020019", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0703950000010001", "intro": "AMS D The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0706210000020003", "intro": "AMS G Slot 2's filament may be broken in AMS." }, { "ecode": "0701230000020002", "intro": "AMS B Slot 4 is empty; please insert a new filament." }, { "ecode": "1804200000020015", "intro": "AMS-HT E slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0701220000020023", "intro": "AMS B slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807230000020011", "intro": "AMS-HT H slot 4 pulls filament back to AMS timeout." }, { "ecode": "0703200000020015", "intro": "AMS D slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700220000020001", "intro": "AMS A Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "1800210000020017", "intro": "AMS-HT A slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0C00030000020015", "intro": "Foreign object detection is not working. Detected the Live View Camera has been replaced. If a laser or cutting module is installed, please uninstall the module, tap \"Settings>Calibration\" on printer screen and re-calibrate the Live View Camera." }, { "ecode": "0703310000010004", "intro": "Encryption chip failure" }, { "ecode": "03001D0000010001", "intro": "The position sensor of extrusion motor is abnormal. The connection to the sensor may be loose." }, { "ecode": "0706230000020018", "intro": "AMS G slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1803220000020005", "intro": "AMS-HT D Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704210000020016", "intro": "AMS E slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0704630000020001", "intro": "The AMS E Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806200000020002", "intro": "AMS-HT G Slot 1 is empty; please insert a new filament." }, { "ecode": "1806120000010003", "intro": "The AMS-HT G slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1803230000020008", "intro": "AMS-HT D Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0500060000020022", "intro": "" }, { "ecode": "1806210000020015", "intro": "AMS-HT G slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1801010000010001", "intro": "The AMS-HT B assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0700200000020006", "intro": "AMS A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1203810000020001", "intro": "AMS D Slot2 filament may be tangled or stuck." }, { "ecode": "0300920000010006", "intro": "The temperature of chamber heater 2 is abnormal. The sensor may have a short circuit." }, { "ecode": "1203220000020004", "intro": "AMS D Slot3 filament may be broken in the tool head." }, { "ecode": "0705230000020021", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0705120000020004", "intro": "AMS F The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803210000020021", "intro": "AMS-HT D slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1803010000020009", "intro": "AMS-HT D The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "0707010000010003", "intro": "The AMS H assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0706220000020018", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1203230000020001", "intro": "AMS D Slot4 filament has run out; please insert a new filament." }, { "ecode": "0300260000010008", "intro": "The left nozzle touches the heating bed abnormally. Please check whether there is filament residue on the nozzle or foreign matter where the nozzle touches the bed." }, { "ecode": "1807230000030001", "intro": "AMS-HT H Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0706600000020001", "intro": "The AMS G Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "12FF200000030007", "intro": "Checking the filament location of all AMS slots, please wait." }, { "ecode": "1805120000020004", "intro": "AMS-HT F The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1806010000020008", "intro": "AMS-HT G The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "0701310000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "070123000002000A", "intro": "Failed to adjust the filament position of AMS B Slot 4. The filament or buffer may be stuck." }, { "ecode": "1800310000010001", "intro": "The AMS-HT A RFID 2 board has an error." }, { "ecode": "1803800000010001", "intro": "AMS-HT D The current sensor of heater 1 is abnormal." }, { "ecode": "0C0001000001000A", "intro": "The Micro Lidar LED may be broken." }, { "ecode": "1807800000010001", "intro": "AMS-HT H The current sensor of heater 1 is abnormal." }, { "ecode": "0707130000020002", "intro": "The AMS H slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0704730000020002", "intro": "Failed to feed the AMS E Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0C00030000030008", "intro": "Possible spaghetti defects were detected. Please check the print quality and decide if the job should be stopped." }, { "ecode": "1800230000020012", "intro": "AMS-HT A slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0500060000020012", "intro": "" }, { "ecode": "0706210000010082", "intro": "Failed to read the filament information from AMS G slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1800200000020001", "intro": "AMS-HT A Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0300C10000010003", "intro": "Airflow System failed to activate laser mode; please check the air door status." }, { "ecode": "0701210000010081", "intro": "Failed to read the filament information from AMS B slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1801200000010083", "intro": "Failed to read the filament information from AMS-HT B slot 1. The RFID tag may be damaged." }, { "ecode": "1807920000020002", "intro": "AMS-HT H The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "1806550000010004", "intro": "The binding between AMS-HT G and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0500060000020054", "intro": "" }, { "ecode": "1802200000020002", "intro": "AMS-HT C Slot 1 is empty; please insert a new filament." }, { "ecode": "1802230000020004", "intro": "AMS-HT C Slot 4 filament may be broken in the tool head." }, { "ecode": "0703010000020011", "intro": "AMS D The motor assist parameter is lost. Please pull out the filament from the filament hub and then restart the AMS." }, { "ecode": "0706200000010082", "intro": "Failed to read the filament information from AMS G slot 1. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0507050000010010", "intro": "The firmware of AMS H does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0702230000020019", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0706210000020020", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1202200000030001", "intro": "AMS C Slot1 filament has run out. Purging the old filament; please wait." }, { "ecode": "1800230000020013", "intro": "AMS-HT A slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1201300000030003", "intro": "AMS B Slot1 RFID cannot be read because of a structural error." }, { "ecode": "1802100000020004", "intro": "AMS-HT C The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0700710000020004", "intro": "Failed to pull back the AMS A Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0704020000020002", "intro": "AMS E The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1803210000010085", "intro": "Failed to read the filament information from AMS-HT D slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0707200000020024", "intro": "AMS H slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "180121000002000A", "intro": "Failed to adjust the filament position of AMS-HT B Slot 2. The filament or buffer may be stuck." }, { "ecode": "1804610000020001", "intro": "The AMS-HT E Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806950000010001", "intro": "AMS-HT G The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1802720000020004", "intro": "Failed to pull back the AMS-HT C Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1801220000010082", "intro": "Failed to read the filament information from AMS-HT B slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1803200000020002", "intro": "AMS-HT D Slot 1 is empty; please insert a new filament." }, { "ecode": "1802220000020012", "intro": "AMS-HT C slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1807720000020005", "intro": "Failed to feed the AMS-HT H Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0702010000010001", "intro": "The AMS C assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0703300000020002", "intro": "The RFID-tag on AMS D Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1807710000020004", "intro": "Failed to pull back the AMS-HT H Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805200000030001", "intro": "AMS-HT F Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "1806700000020002", "intro": "Failed to feed the AMS-HT G Slot 1 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0C00040000010015", "intro": "Laser Protective Insert not detected. Please place it and continue." }, { "ecode": "0705210000010081", "intro": "Failed to read the filament information from AMS F slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1202330000020002", "intro": "The RFID-tag on AMS C Slot 4 is damaged." }, { "ecode": "1801120000010003", "intro": "The AMS-HT B slot 3 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "180523000002000A", "intro": "Failed to adjust the filament position of AMS-HT F Slot 4. The filament or buffer may be stuck." }, { "ecode": "1801120000010001", "intro": "The AMS-HT B slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707220000010085", "intro": "Failed to read the filament information from AMS H slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0300060000010003", "intro": "The resistance of Motor-A is abnormal; the motor may have failed." }, { "ecode": "1801010000020007", "intro": "AMS-HT B The assist motor encoder wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "1806130000020004", "intro": "AMS-HT G The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807700000020005", "intro": "Failed to feed the AMS-HT H Slot 1 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0706230000020016", "intro": "AMS G slot 4 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1804230000010081", "intro": "Failed to read the filament information from AMS-HT E slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1200230000020002", "intro": "AMS A Slot 4 is empty; please insert a new filament." }, { "ecode": "1805220000020004", "intro": "AMS-HT F Slot 3 filament may be broken in the tool head." }, { "ecode": "18FF810000010001", "intro": "The extruder switching motor is working abnormally. Please check whether the connecting cable is loose." }, { "ecode": "070523000002000A", "intro": "Failed to adjust the filament position of AMS F Slot 4. The filament or buffer may be stuck." }, { "ecode": "0706230000020013", "intro": "AMS G slot 4 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705230000020003", "intro": "AMS F Slot 4's filament may be broken in AMS." }, { "ecode": "0703210000020001", "intro": "AMS D Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0300060000010002", "intro": "Motor-A has a short-circuit. It may have failed." }, { "ecode": "1201210000020006", "intro": "Failed to extrude AMS B Slot2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1202220000020004", "intro": "AMS C Slot3 filament may be broken in the tool head." }, { "ecode": "1203820000020001", "intro": "AMS D Slot3 filament may be tangled or stuck." }, { "ecode": "0703010000020002", "intro": "The AMS D assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0706010000010005", "intro": "AMS G The current sensor of assist motor may be faulty." }, { "ecode": "0702910000010002", "intro": "AMS C The coil resistance of exhaust valve 2 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "1805220000020017", "intro": "AMS-HT F slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0705220000010084", "intro": "Failed to read the filament information from AMS F slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1803200000020014", "intro": "AMS-HT D slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1803200000020007", "intro": "AMS-HT D Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0704230000030002", "intro": "AMS E Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0705200000020011", "intro": "AMS F slot 1 pulls filament back to AMS timeout." }, { "ecode": "1802230000010085", "intro": "Failed to read the filament information from AMS-HT C slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0706720000020001", "intro": "Failed to pull out the AMS G Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0701200000010086", "intro": "Failed to read the filament information from AMS B slot 1. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1202210000020002", "intro": "AMS C Slot 2 is empty; please insert a new filament." }, { "ecode": "1807220000010083", "intro": "Failed to read the filament information from AMS-HT H slot 3. The RFID tag may be damaged." }, { "ecode": "1805220000020002", "intro": "AMS-HT F Slot 3 is empty; please insert a new filament." }, { "ecode": "0702300000010004", "intro": "Encryption chip failure" }, { "ecode": "0703210000020016", "intro": "AMS D slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0705220000020018", "intro": "AMS F slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703210000020024", "intro": "AMS D slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1803720000020002", "intro": "Failed to feed the AMS-HT D Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1805200000010081", "intro": "Failed to read the filament information from AMS-HT F slot 1. The AMS main board may be malfunctioning." }, { "ecode": "1806730000020002", "intro": "Failed to feed the AMS-HT G Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1802100000010003", "intro": "The AMS-HT C slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0500060000020008", "intro": "" }, { "ecode": "0702200000010081", "intro": "Failed to read the filament information from AMS C slot 1. The AMS main board may be malfunctioning." }, { "ecode": "0703230000010084", "intro": "Failed to read the filament information from AMS D slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0500010000030005", "intro": "The USB drive is in Read-Only mode. Video recording and Timelapse recording cannot be performed. Please refer to the Wiki for assistance." }, { "ecode": "0706210000020005", "intro": "AMS G Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1807230000020008", "intro": "AMS-HT H Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1802220000020022", "intro": "AMS-HT C slot 3 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0500040000030008", "intro": "The door seems to be open." }, { "ecode": "1203500000020001", "intro": "AMS D communication is abnormal; please check the connection cable." }, { "ecode": "1200210000020005", "intro": "AMS A Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0705230000020015", "intro": "AMS F slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0300330000020002", "intro": "The Chamber Exhaust Fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "0703230000010082", "intro": "Failed to read the filament information from AMS D slot 4. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0C00010000020017", "intro": "Nozzle camera lens is dirty, which may affect the AI monitoring functionality. Please clean the surface of the nozzle camera lens as soon as possible." }, { "ecode": "0700110000020004", "intro": "AMS A The brushed motor 2 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "070320000002000A", "intro": "Failed to adjust the filament position of AMS D Slot 1. The filament or buffer may be stuck." }, { "ecode": "180020000002000A", "intro": "Failed to adjust the filament position of AMS-HT A Slot 1. The filament or buffer may be stuck." }, { "ecode": "050004000002001E", "intro": "The RFID-tag on AMS D Slot3 cannot be identified." }, { "ecode": "07FF800000010006", "intro": "The TH board disconnected during the extruder switching process. Please check if the connecting cable is loose." }, { "ecode": "0702730000020001", "intro": "Failed to pull out the AMS C Slot 4 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "1804220000020020", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1805930000020002", "intro": "AMS-HT F The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "1806210000020010", "intro": "AMS-HT G slot 2 feeds filament out of AMS timeout." }, { "ecode": "0701730000020005", "intro": "Failed to feed the AMS B Slot 4 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "030091000001000C", "intro": "The chamber heater 1 has worked at full load for a long time. The temperature control system may be abnormal." }, { "ecode": "0703130000020002", "intro": "The AMS D slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1801600000020001", "intro": "The AMS-HT B Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0701130000010003", "intro": "The AMS B slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0704100000010001", "intro": "The AMS E slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1806230000020024", "intro": "AMS-HT G slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1804230000020018", "intro": "AMS-HT E slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "0703550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0705800000010001", "intro": "AMS F The current sensor of heater 1 is abnormal." }, { "ecode": "0707230000020019", "intro": "AMS H slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1800810000010003", "intro": "AMS-HT A The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1800800000010002", "intro": "AMS-HT A The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "0703700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0700100000020004", "intro": "AMS A The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1803210000010083", "intro": "Failed to read the filament information from AMS-HT D slot 2. The RFID tag may be damaged." }, { "ecode": "0702230000020018", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1807220000020007", "intro": "AMS-HT H Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0703120000020004", "intro": "AMS D The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705230000020007", "intro": "AMS F Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0707900000010003", "intro": "AMS H The exhaust valve 1 is not connected, which may be due to poor connector contact." }, { "ecode": "0702220000020004", "intro": "AMS C Slot 3 filament may be broken in the tool head." }, { "ecode": "0707810000010003", "intro": "AMS H The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0702130000020004", "intro": "AMS C The brushed motor 4 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802200000020006", "intro": "AMS-HT C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1805900000020001", "intro": "AMS-HT F The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "18FE810000010003", "intro": "The hall signal of the Extruder Switching Motor is abnormal, possibly due to internal communication failure in the Toolhead module." }, { "ecode": "0704960000010001", "intro": "AMS E The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "1807210000020019", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1804220000020017", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1805210000020018", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1805960000020002", "intro": "AMS-HT F Environmental temperature is too low, which will affect the drying capability." }, { "ecode": "1800200000020010", "intro": "AMS-HT A slot 1 feeds filament out of AMS timeout." }, { "ecode": "18FF200000020001", "intro": "External filament of right extruder has run out; please load a new filament." }, { "ecode": "1203200000020002", "intro": "AMS D Slot 1 is empty; please insert a new filament." }, { "ecode": "1806200000020011", "intro": "AMS-HT G slot 1 pulls filament back to AMS timeout." }, { "ecode": "1203200000020003", "intro": "AMS D Slot1 filament may be broken in the PTFE tube." }, { "ecode": "0700700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0703210000010081", "intro": "Failed to read the filament information from AMS D slot 2. The AMS main board may be malfunctioning." }, { "ecode": "1805200000020005", "intro": "AMS-HT F Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1801210000020014", "intro": "AMS-HT B slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1800200000020006", "intro": "AMS-HT A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0584050000010010", "intro": "The firmware of AMS-HT E does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1202330000010001", "intro": "AMS C Slot 4 RFID coil is broken or the RF hardware circuit has an error." }, { "ecode": "1804700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1804210000010083", "intro": "Failed to read the filament information from AMS-HT E slot 2. The RFID tag may be damaged." }, { "ecode": "0706200000020002", "intro": "AMS G Slot 1 is empty; please insert a new filament." }, { "ecode": "1803010000020008", "intro": "AMS-HT D The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "0700210000020020", "intro": "AMS A slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0707120000020004", "intro": "AMS H The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705720000020002", "intro": "Failed to feed the AMS F Slot 3 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1803210000020024", "intro": "AMS-HT D slot 2 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1802210000020021", "intro": "AMS-HT C slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0706210000020004", "intro": "AMS G Slot 2 filament may be broken in the tool head." }, { "ecode": "1807210000020005", "intro": "AMS-HT H Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0700230000030001", "intro": "AMS A Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800220000020020", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706210000030001", "intro": "AMS G Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1800710000020005", "intro": "Failed to feed the AMS-HT A Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0700310000010001", "intro": "The AMS A RFID 2 board has an error." }, { "ecode": "0C0003000003000D", "intro": "Detected that the extruder may not be extruding normally. Please check and decide if printing should be stopped." }, { "ecode": "1202130000010003", "intro": "The AMS C Slot4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0704110000010003", "intro": "The AMS E slot 2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0707200000020023", "intro": "AMS H slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "03001E0000010007", "intro": "The left nozzle temperature is abnormal; the sensor may have an open circuit." }, { "ecode": "0C00040000030018", "intro": "The Cutting blade offset calibration failed. This may affect the cutting accuracy. Please refer to the Wiki to check if the blade tip is worn." }, { "ecode": "0300970000010003", "intro": "The top cover Hall sensor (Rear Left) is abnormal; please check whether the connection wire is loose." }, { "ecode": "0704250000020001", "intro": "AMS E uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1203210000020005", "intro": "AMS D Slot2 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "1803230000030001", "intro": "AMS-HT D Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "0703200000020019", "intro": "AMS D slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1804710000020005", "intro": "Failed to feed the AMS-HT E Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1804230000030002", "intro": "AMS-HT E Slot 4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0703210000020020", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0702120000020002", "intro": "The AMS C slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0701230000010084", "intro": "Failed to read the filament information from AMS B slot 4. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1803220000010081", "intro": "Failed to read the filament information from AMS-HT D slot 3. The AMS main board may be malfunctioning." }, { "ecode": "1805200000020016", "intro": "AMS-HT F slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "0706230000020011", "intro": "AMS G slot 4 pulls filament back to AMS timeout." }, { "ecode": "0700120000020002", "intro": "The AMS A slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0702230000010085", "intro": "Failed to read the filament information from AMS C slot 4. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "07FE450000020002", "intro": "The filament cutter's cutting distance is too large. Possible causes include the filament cutter stopper skipping teeth, motor losing steps, or the XY axis not being homed." }, { "ecode": "0702210000020005", "intro": "AMS C Slot 2 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0300970000010004", "intro": "The Top Laser Protection Plate is not detected. Please install it according to the Wiki and re-initiate the task." }, { "ecode": "0300080000010003", "intro": "The resistance of Motor-Z is abnormal; the motor may have failed." }, { "ecode": "0500020000020006", "intro": "Streaming function error. Please check the network and try again. You can restart or update the printer if the issue persists." }, { "ecode": "0700220000010082", "intro": "Failed to read the filament information from AMS A slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1806220000020018", "intro": "AMS-HT G slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "18FE600000020001", "intro": "External spool connected to left extruder may be tangled or jammed." }, { "ecode": "0705210000020013", "intro": "AMS F slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705010000020002", "intro": "The AMS F assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803800000010002", "intro": "AMS-HT D The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "1800220000020024", "intro": "AMS-HT A slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1801230000020003", "intro": "AMS-HT B Slot 4's filament may be broken in AMS-HT." }, { "ecode": "0300080000010002", "intro": "Motor-Z has a short-circuit. It may have failed." }, { "ecode": "1804810000010002", "intro": "AMS-HT E The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "1803230000020012", "intro": "AMS-HT D slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1800200000020003", "intro": "AMS-HT A Slot 1's filament may be broken in AMS-HT." }, { "ecode": "1805230000020019", "intro": "AMS-HT F slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "0702800000010003", "intro": "AMS C The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0300310000010001", "intro": "The Part Cooling Fan speed is too slow or stopped. It may be stuck, or the connector may not be plugged in properly." }, { "ecode": "1801220000020021", "intro": "AMS-HT B slot 3 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1804230000030001", "intro": "AMS-HT E Slot 4 filament has run out. Please wait while old filament is purged." }, { "ecode": "1801010000020002", "intro": "The AMS-HT B assist motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800200000010085", "intro": "Failed to read the filament information from AMS-HT A slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0703210000020022", "intro": "AMS D slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0500060000020062", "intro": "" }, { "ecode": "0700130000010003", "intro": "The AMS A slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0500030000010009", "intro": "A system hang occurred. It has been recovered by automatic restart." }, { "ecode": "1804330000020002", "intro": "The RFID-tag on AMS-HT E Slot4 is damaged, or its content cannot be identified." }, { "ecode": "0C00030000020010", "intro": "Foreign objects detected on heatbed; Please check and clean the heatbed." }, { "ecode": "1803200000030002", "intro": "AMS-HT D Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0703220000020001", "intro": "AMS D Slot 3 filament has run out. Please insert a new filament." }, { "ecode": "0704230000020005", "intro": "AMS E Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1807230000020002", "intro": "AMS-HT H Slot 4 is empty; please insert a new filament." }, { "ecode": "1805950000010001", "intro": "AMS-HT F The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1806700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0701120000020004", "intro": "AMS B The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702200000020020", "intro": "AMS C slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0707700000020001", "intro": "Failed to pull out the AMS H Slot 1 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0500050000010006", "intro": "The factory data of AP board is abnormal; please replace the AP board with a new one." }, { "ecode": "1800350000010002", "intro": "AMS-HT A The humidity sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0706200000030002", "intro": "AMS G Slot 1 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1201210000020001", "intro": "AMS B Slot2 filament has run out; please insert a new filament." }, { "ecode": "1807220000020003", "intro": "AMS-HT H Slot 3's filament may be broken in AMS-HT." }, { "ecode": "070423000002000A", "intro": "Failed to adjust the filament position of AMS E Slot 4. The filament or buffer may be stuck." }, { "ecode": "0703560000030001", "intro": "AMS D is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0702710000020001", "intro": "Failed to pull out the AMS C Slot 2 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0500030000010003", "intro": "The AMS module is malfunctioning. Please restart the device." }, { "ecode": "0707210000010084", "intro": "Failed to read the filament information from AMS H slot 2. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "1806020000020002", "intro": "AMS-HT G The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1805230000010081", "intro": "Failed to read the filament information from AMS-HT F slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1802610000020001", "intro": "The AMS-HT C Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0300270000010007", "intro": "The nozzle offset calibration sensor frequency is too high. The sensor may be damaged." }, { "ecode": "1800220000020017", "intro": "AMS-HT A slot 3 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1804010000020008", "intro": "AMS-HT E The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1800200000020008", "intro": "AMS-HT A Slot 1 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0703310000010001", "intro": "The AMS D RFID 2 board has an error." }, { "ecode": "1804220000020005", "intro": "AMS-HT E Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0701720000020005", "intro": "Failed to feed the AMS B Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0C00040000020019", "intro": "The Birdseye Camera is installed offset. Please refer to the Wiki to reinstall it." }, { "ecode": "1800200000020007", "intro": "AMS-HT A Slot 1 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1801220000030002", "intro": "AMS-HT B Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1801210000020023", "intro": "AMS-HT B slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0706700000020007", "intro": "AMS filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1801020000020002", "intro": "AMS-HT B The odometer has no signal. The odometer connector may have poor contact." }, { "ecode": "1803210000010086", "intro": "Failed to read the filament information from AMS-HT D slot 2. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1802200000020013", "intro": "AMS-HT C slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0702310000020002", "intro": "The RFID-tag on AMS C Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0703230000020003", "intro": "AMS D Slot 4's filament may be broken in AMS." }, { "ecode": "1806220000020013", "intro": "AMS-HT G slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804210000020015", "intro": "AMS-HT E slot 2 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0707960000010003", "intro": "AMS H Unable to start drying; please pull out the filament from filament hub and try again." }, { "ecode": "1802200000020024", "intro": "AMS-HT C slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1806230000020010", "intro": "AMS-HT G slot 4 feeds filament out of AMS timeout." }, { "ecode": "0706230000020010", "intro": "AMS G slot 4 feeds filament out of AMS timeout." }, { "ecode": "1202300000010004", "intro": "RFID cannot be read because of an encryption chip failure in AMS C." }, { "ecode": "1805210000020021", "intro": "AMS-HT F slot 2 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1803210000020002", "intro": "AMS-HT D Slot 2 is empty; please insert a new filament." }, { "ecode": "0704220000020013", "intro": "AMS E slot 3 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1802730000020002", "intro": "Failed to feed the AMS-HT C Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1807200000020016", "intro": "AMS-HT H slot 1 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807230000020012", "intro": "AMS-HT H slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0300200000010001", "intro": "X-axis homing abnormal: please check if the toolhead is stuck or if the resistance on the X-axis linear rail is too high." }, { "ecode": "1201220000020005", "intro": "AMS B Slot3 filament has run out, and purging the old filament went abnormally; please check to see if filament is stuck in the toolhead." }, { "ecode": "0703210000010085", "intro": "Failed to read the filament information from AMS D slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1804700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "1802210000020013", "intro": "AMS-HT C slot 2 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "07FE810000010002", "intro": "The position hall sensor of the Extruder Switching Motor has an open circuit. Please check whether the connecting cable is loose." }, { "ecode": "0701920000020002", "intro": "AMS B The cooling fan speed of heater 1 is too low, which could be due to excessive fan resistance." }, { "ecode": "1806120000020004", "intro": "AMS-HT G The brushed motor 3 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0705230000020012", "intro": "AMS F slot 4 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0704010000010005", "intro": "AMS E The current sensor of assist motor may be faulty." }, { "ecode": "0700450000020001", "intro": "The filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in." }, { "ecode": "1807560000030001", "intro": "AMS-HT H is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "1200810000020001", "intro": "AMS A Slot2 filament may be tangled or stuck." }, { "ecode": "0700940000010001", "intro": "AMS A The temperature sensor of heater 1 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0705010000010001", "intro": "The AMS F assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "1807630000020001", "intro": "The AMS-HT H Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1806330000020002", "intro": "The RFID-tag on AMS-HT G Slot4 is damaged, or its content cannot be identified." }, { "ecode": "1803230000020001", "intro": "AMS-HT D Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "03001A0000020001", "intro": "The nozzle is covered with filament, or the build plate is crooked." }, { "ecode": "1807200000020002", "intro": "AMS-HT H Slot 1 is empty; please insert a new filament." }, { "ecode": "1802200000020001", "intro": "AMS-HT C Slot 1 filament has run out. Please insert a new filament." }, { "ecode": "0701950000010001", "intro": "AMS B The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0702200000020014", "intro": "AMS C slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704200000020002", "intro": "AMS E Slot 1 is empty; please insert a new filament." }, { "ecode": "1200210000030001", "intro": "AMS A Slot2 filament has run out. Purging the old filament; please wait." }, { "ecode": "1805350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1200230000020001", "intro": "AMS A Slot4 filament has run out; please insert a new filament." }, { "ecode": "0705220000020005", "intro": "AMS F Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1803900000010002", "intro": "AMS-HT D The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "0702120000010001", "intro": "The AMS C slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0500040000010006", "intro": "Failed to resume previous print" }, { "ecode": "0300960000010004", "intro": "The Front Laser Safety Window is not detected. Please install it according to the Wiki and re-initiate the task." }, { "ecode": "0705210000020016", "intro": "AMS F slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1807930000010001", "intro": "AMS-HT H The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "050005000001000E", "intro": "Laser Module firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0706220000010084", "intro": "Failed to read the filament information from AMS G slot 3. The RFID tag may be damaged or positioned at the edge of the RFID detection device. Please remove 5cm filament and try again." }, { "ecode": "0706930000010001", "intro": "AMS G The cooling fan of heater 2 is blocked, which may be due to the fan being stuck." }, { "ecode": "1807210000030001", "intro": "AMS-HT H Slot 2 filament has run out. Please wait while old filament is purged." }, { "ecode": "1804700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0700220000020020", "intro": "AMS A slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0500040000020007", "intro": "The bed temperature exceeds the filament's vitrification temperature, which may cause a nozzle clog. Please keep the front door of the printer open or lower the bed temperature." }, { "ecode": "0500060000020053", "intro": "" }, { "ecode": "1803220000010083", "intro": "Failed to read the filament information from AMS-HT D slot 3. The RFID tag may be damaged." }, { "ecode": "0704100000020004", "intro": "AMS E The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "0704200000020022", "intro": "AMS E slot 1 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1203230000020006", "intro": "Failed to extrude AMS D Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1806320000020002", "intro": "The RFID-tag on AMS-HT G Slot3 is damaged, or its content cannot be identified." }, { "ecode": "1807500000020001", "intro": "AMS-HT H communication is abnormal; please check the connection cable." }, { "ecode": "0700230000020008", "intro": "AMS A Slot 4 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0701220000010085", "intro": "Failed to read the filament information from AMS B slot 3. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0587050000010010", "intro": "The firmware of AMS-HT H does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0700230000020024", "intro": "AMS A slot 4 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "1200710000010001", "intro": "AMS A Filament speed and length error: The slot 2 filament odometry may be faulty." }, { "ecode": "1202200000020002", "intro": "AMS C Slot 1 is empty; please insert a new filament." }, { "ecode": "1801210000010082", "intro": "Failed to read the filament information from AMS-HT B slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0701200000020021", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0702560000030001", "intro": "AMS C is undergoing dry cooling; please wait for it to cool down before operating." }, { "ecode": "0500010000020003", "intro": "" }, { "ecode": "0701210000020002", "intro": "AMS B Slot 2 is empty; please insert a new filament." }, { "ecode": "0700720000020005", "intro": "Failed to feed the AMS A Slot 3 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0C00030000020013", "intro": "Foreign object detection is not working. Please restart the devices or update the firmware." }, { "ecode": "1804220000020011", "intro": "AMS-HT E slot 3 pulls filament back to AMS timeout." }, { "ecode": "1801700000020007", "intro": "AMS-HT filament ran out. Please put a new filament into the same slot in AMS and resume." }, { "ecode": "0701310000010004", "intro": "Encryption chip failure" }, { "ecode": "07FE450000020003", "intro": "The filament cutter handle has not been released. The handle or blade may be jammed, or there could be an issue with the filament sensor connection." }, { "ecode": "0702020000010001", "intro": "AMS C Filament speed and length error: The filament odometry may be faulty." }, { "ecode": "0706230000010086", "intro": "Failed to read the filament information from AMS G slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1804220000020007", "intro": "AMS-HT E Slot 3 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0300930000010006", "intro": "Chamber temperature is abnormal. The chamber temperature sensor at the air inlet may have an open circuit." }, { "ecode": "0701210000020009", "intro": "Failed to extrude AMS B Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0704500000020001", "intro": "AMS E communication is abnormal; please check the connection cable." }, { "ecode": "0706210000020022", "intro": "AMS G slot 2 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "1802100000020002", "intro": "The AMS-HT C slot 1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800210000020001", "intro": "AMS-HT A Slot 2 filament has run out. Please insert a new filament." }, { "ecode": "0702230000020010", "intro": "AMS C slot 4 feeds filament out of AMS timeout." }, { "ecode": "1804200000020006", "intro": "AMS-HT E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1803810000010003", "intro": "AMS-HT D The heater 2 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "0300010000010002", "intro": "The heatbed temperature is abnormal; the heater may have an open circuit, or the thermal switch may be open." }, { "ecode": "1800010000020009", "intro": "AMS-HT A The assist motor has unbalanced tree-phase resistaance. The assist motor may be faulty." }, { "ecode": "1800200000020019", "intro": "AMS-HT A slot 1 assist motor is stalled,due to excessive resistance in the tube between AMS and the filament buffer." }, { "ecode": "1804230000020003", "intro": "AMS-HT E Slot 4's filament may be broken in AMS-HT." }, { "ecode": "0706220000020009", "intro": "Failed to extrude AMS G Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800200000020002", "intro": "AMS-HT A Slot 1 is empty; please insert a new filament." }, { "ecode": "1201230000020001", "intro": "AMS B Slot4 filament has run out; please insert a new filament." }, { "ecode": "030091000001000A", "intro": "The temperature of chamber heater 1 is abnormal. The AC board may be broken." }, { "ecode": "0701200000020020", "intro": "AMS B slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1804220000020018", "intro": "AMS-HT E slot 3 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1203210000030001", "intro": "AMS D Slot2 filament has run out. Purging the old filament; please wait." }, { "ecode": "0704200000020015", "intro": "AMS E slot 1 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "0700200000020005", "intro": "AMS A Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1807230000020004", "intro": "AMS-HT H Slot 4 filament may be broken in the tool head." }, { "ecode": "0707960000010001", "intro": "AMS H The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "1801100000020004", "intro": "AMS-HT B The brushed motor 1 has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1807230000020007", "intro": "AMS-HT H Slot 4 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1805010000010005", "intro": "AMS-HT F The current sensor of assist motor may be faulty." }, { "ecode": "1806210000020017", "intro": "AMS-HT G slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0701710000020004", "intro": "Failed to pull back the AMS B Slot 2 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1806210000020023", "intro": "AMS-HT G slot 2 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1807200000020023", "intro": "AMS-HT H slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1801200000020009", "intro": "Failed to extrude AMS-HT B Slot 1 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1800700000020003", "intro": "Failed to extrude the filament. Possible cause: extruder or nozzle clog." }, { "ecode": "1802210000020016", "intro": "AMS-HT C slot 2 assist motor has slipped. Please pull out the filament, cut off the worn part, and then try again." }, { "ecode": "1801710000020005", "intro": "Failed to feed the AMS-HT B Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "1803730000020002", "intro": "Failed to feed the AMS-HT D Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "0C00040000010010", "intro": "Failed to measure material thickness due to laser module malfunction." }, { "ecode": "1807010000020008", "intro": "AMS-HT H The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1803220000030001", "intro": "AMS-HT D Slot 3 filament has run out. Please wait while old filament is purged." }, { "ecode": "1803200000030001", "intro": "AMS-HT D Slot 1 filament has run out. Please wait while old filament is purged." }, { "ecode": "0706200000020011", "intro": "AMS G slot 1 pulls filament back to AMS timeout." }, { "ecode": "0704550000010004", "intro": "The binding between AMS E and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0703230000010086", "intro": "Failed to read the filament information from AMS D slot 4. The RFID tag cannot rotate due to a jam during the filament loading or unloading. Please pull out the filament and try again." }, { "ecode": "1801220000020015", "intro": "AMS-HT B slot 3 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1202800000020001", "intro": "AMS C Slot1 filament may be tangled or stuck." }, { "ecode": "1806230000020001", "intro": "AMS-HT G Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1804230000020014", "intro": "AMS-HT E slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1802210000010085", "intro": "Failed to read the filament information from AMS-HT C slot 2. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "1805210000030002", "intro": "AMS-HT F Slot 2 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "1802300000020002", "intro": "The RFID-tag on AMS-HT C Slot1 is damaged, or its content cannot be identified." }, { "ecode": "0701210000010083", "intro": "Failed to read the filament information from AMS B slot 2. The RFID tag may be damaged." }, { "ecode": "1203110000010003", "intro": "The AMS D Slot2 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1804220000020023", "intro": "AMS-HT E slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0701220000010081", "intro": "Failed to read the filament information from AMS B slot 3. The AMS main board may be malfunctioning." }, { "ecode": "0707230000020015", "intro": "AMS H slot 4 filament status is abnormal, which may be due to a filament breakage inside the AMS." }, { "ecode": "1800550000020001", "intro": "A new AMS-HT detected. Please set it up to check which extruder the AMS-HT is connected to." }, { "ecode": "0700230000020023", "intro": "AMS A slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0C00010000020008", "intro": "Failed to get image from Live View Camera. Spaghetti and waste chute pileup detection is not available at this time." }, { "ecode": "1804130000020002", "intro": "The AMS-HT E slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "0300170000020002", "intro": "The hotend cooling fan speed is slow. It may be stuck and need cleaning." }, { "ecode": "0707310000020002", "intro": "The RFID-tag on AMS H Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0703220000020005", "intro": "AMS D Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0704210000010082", "intro": "Failed to read the filament information from AMS E slot 2. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "0701220000020009", "intro": "Failed to extrude AMS B Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "1805300000030003", "intro": "RFID cannot be read because of a hardware or structural error." }, { "ecode": "0703960000010001", "intro": "AMS D The drying process may experience thermal runaway. Please turn off the AMS power supply." }, { "ecode": "0705100000010003", "intro": "The AMS F slot 1 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1806120000010001", "intro": "The AMS-HT G slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1806810000010002", "intro": "AMS-HT G The heater 2 is disconnected, which may be due to poor connector contact." }, { "ecode": "0704210000020020", "intro": "AMS E slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706720000020004", "intro": "Failed to pull back the AMS G Slot 3 filament from the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0700010000020008", "intro": "AMS A The assist motor phase winding has an open circuit. The assist motor may be faulty." }, { "ecode": "1804200000020005", "intro": "AMS-HT E Slot 1 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1805550000010004", "intro": "The binding between AMS-HT F and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0707230000020005", "intro": "AMS H Slot 4 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "1806220000020005", "intro": "AMS-HT G Slot 3 filament has run out, and purging the old filament went abnormally; please check whether the filament is stuck in the tool head." }, { "ecode": "0706230000020004", "intro": "AMS G Slot 4 filament may be broken in the tool head." }, { "ecode": "0500060000020051", "intro": "" }, { "ecode": "1801220000020010", "intro": "AMS-HT B slot 3 feeds filament out of AMS timeout." }, { "ecode": "1803130000010003", "intro": "The AMS-HT D slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1807210000020020", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "1806350000010001", "intro": "The temperature and humidity sensor has an error. The chip may be faulty." }, { "ecode": "1804900000020001", "intro": "AMS-HT E The operation of the exhaust valve 1 is abnormal, which may be due to excessive resistance." }, { "ecode": "0705230000020002", "intro": "AMS F Slot 4 is empty; please insert a new filament." }, { "ecode": "1200830000020001", "intro": "AMS A Slot4 filament may be tangled or stuck." }, { "ecode": "1805810000010001", "intro": "AMS-HT F The current sensor of heater 2 is abnormal." }, { "ecode": "0703800000010001", "intro": "AMS D The current sensor of heater 1 is abnormal." }, { "ecode": "1201230000020002", "intro": "AMS B Slot 4 is empty; please insert a new filament." }, { "ecode": "0701230000020001", "intro": "AMS B Slot 4 filament has run out. Please insert a new filament." }, { "ecode": "1805010000010003", "intro": "The AMS-HT F assist motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "0300980000030001", "intro": "The left side window seems to be open." }, { "ecode": "0C00040000010005", "intro": "BirdsEye Camera malfunction: please contact customer support." }, { "ecode": "1203200000020001", "intro": "AMS D Slot1 filament has run out; please insert a new filament." }, { "ecode": "0707130000010001", "intro": "The AMS H slot 4 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0707550000010004", "intro": "The binding between AMS H and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "0707630000020001", "intro": "The AMS H Slot 4 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1800220000020003", "intro": "AMS-HT A Slot 3's filament may be broken in AMS-HT." }, { "ecode": "1806800000010003", "intro": "AMS-HT G The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1804210000020007", "intro": "AMS-HT E Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "1805220000030002", "intro": "AMS-HT F Slot 3 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0704130000020002", "intro": "The AMS E slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1802550000010003", "intro": "AMS-HT C was detected offline during the AMS initialization process." }, { "ecode": "0585050000010010", "intro": "The firmware of AMS-HT F does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0706210000020007", "intro": "AMS G Slot 2 feed-out Hall sensor is disconnected. The connector may have poor contact." }, { "ecode": "0707210000020018", "intro": "AMS H slot 2 assist motor is stalled,due to excessive resistance in the tube near AMS." }, { "ecode": "1805230000020014", "intro": "AMS-HT F slot 4 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0701130000020002", "intro": "The AMS B slot 4 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1805120000020002", "intro": "The AMS-HT F slot 3 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1800100000010001", "intro": "The AMS-HT A slot 1 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "0706230000020003", "intro": "AMS G Slot 4's filament may be broken in AMS." }, { "ecode": "1806800000010002", "intro": "AMS-HT G The heater 1 is disconnected, which may be due to poor connector contact." }, { "ecode": "07FF800000020002", "intro": "The position of left hotend is abnormal during printing. Please check whether the flow blocker scratches the printed model." }, { "ecode": "1803200000010083", "intro": "Failed to read the filament information from AMS-HT D slot 1. The RFID tag may be damaged." }, { "ecode": "0706310000020002", "intro": "The RFID-tag on AMS G Slot2 is damaged, or its content cannot be identified." }, { "ecode": "0702230000020022", "intro": "AMS C slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "0704210000020012", "intro": "AMS E slot 2 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "1803700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0500040000010003", "intro": "The content of print file is unreadable; please resend the print job." }, { "ecode": "1804240000020009", "intro": "AMS-HT E front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "1803200000020020", "intro": "AMS-HT D slot 1 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706310000010004", "intro": "Encryption chip failure" }, { "ecode": "0702010000020006", "intro": "AMS C The assist motor three-phase wires are not connected. The assist motor connector may have poor contact." }, { "ecode": "0500060000020034", "intro": "Live View camera is not connected. Please check the hardware and cable connections." }, { "ecode": "1804800000010004", "intro": "AMS-HT E The heater 1 is heating abnormally." }, { "ecode": "0700220000020011", "intro": "AMS A slot 3 pulls filament back to AMS timeout." }, { "ecode": "1807210000020017", "intro": "AMS-HT H slot 2 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "1201230000030002", "intro": "AMS B Slot4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0702550000010002", "intro": "The PTFE tube is incorrectly connected between the toolhead and the buffer. Please connect the buffer's top to the right extruder and the bottom to the left extruder." }, { "ecode": "0704950000010001", "intro": "AMS E The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0700210000020004", "intro": "AMS A Slot 2 filament may be broken in the tool head." }, { "ecode": "0705220000020009", "intro": "Failed to extrude AMS F Slot 3 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0700220000020008", "intro": "AMS A Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "0300090000010002", "intro": "The extruder servo motor has a short-circuit. It may have failed." }, { "ecode": "1202100000020002", "intro": "The AMS C Slot1 motor is overloaded. The filament may be tangled or stuck." }, { "ecode": "1803210000020009", "intro": "Failed to extrude AMS-HT D Slot 2 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0701230000020011", "intro": "AMS B slot 4 pulls filament back to AMS timeout." }, { "ecode": "0700200000010085", "intro": "Failed to read the filament information from AMS A slot 1. RFID tag verification failed. You can try to use Bambu Lab filament." }, { "ecode": "0702950000010001", "intro": "AMS C The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "1202230000020006", "intro": "Failed to extrude AMS C Slot4 filament; the extruder may be clogged or the filament may be too thin, causing the extruder to slip." }, { "ecode": "0706710000020005", "intro": "Failed to feed the AMS G Slot 2 filament. Please trim the end of the filament and check if the spool is stuck." }, { "ecode": "0707610000020001", "intro": "The AMS H Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1802240000020009", "intro": "AMS-HT C front cover is open. This may affect the drying performance or cause the filament to absorb moisture." }, { "ecode": "0C0001000003000C", "intro": "Nozzle Camera's temperature is too high, causing the AI detection feature to pause. The feature will automatically resume once the temperature returns to normal." }, { "ecode": "1800900000010002", "intro": "AMS-HT A The coil resistance of exhaust valve 1 is abnormal, which may be due to abnormal wiring or damage." }, { "ecode": "050005000001000D", "intro": "The BirdsEye Camera is malfunctioning. Please try restarting the device. If the issue persists after multiple restarts, check the camera connection status or contact customer support." }, { "ecode": "1800120000010001", "intro": "The AMS-HT A slot 3 motor has slipped. The extrusion wheel may be malfunctioning, or the filament may be too thin." }, { "ecode": "1803220000020024", "intro": "AMS-HT D slot 3 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0702550000010004", "intro": "The binding between AMS C and the extruder is incorrect. Please run the AMS Setup." }, { "ecode": "1203800000020001", "intro": "AMS D Slot1 filament may be tangled or stuck." }, { "ecode": "1801230000020017", "intro": "AMS-HT B slot 4 assist motor is stalled,due to excessive resistance in the tube between AMS and the printer." }, { "ecode": "0703200000020013", "intro": "AMS D slot 1 feeder unit motor has no signal, which may be due to poor contact in the motor connector or a motor fault." }, { "ecode": "1804230000020010", "intro": "AMS-HT E slot 4 feeds filament out of AMS timeout." }, { "ecode": "0706130000010003", "intro": "The AMS G slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1802010000010001", "intro": "The AMS-HT C assist motor has slipped. The extrusion wheel may be worn down, or the filament may be too thin." }, { "ecode": "0704220000020012", "intro": "AMS E slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "03001E0000010006", "intro": "The left nozzle temperature is abnormal; the sensor may have a short circuit, please check whether the connector is properly plugged in." }, { "ecode": "1800400000020004", "intro": "The filament buffer signal is abnormal; the spring may be stuck, or the filament may be tangled." }, { "ecode": "1802210000020014", "intro": "AMS-HT C slot 2 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "0704700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "1803220000020020", "intro": "AMS-HT D slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0706220000020020", "intro": "AMS G slot 3 assist motor is stalled,due to excessive resistance in the tube near the filament buffer。" }, { "ecode": "0701610000020001", "intro": "The AMS B Slot 2 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "0706950000010001", "intro": "AMS G The temperature sensor of heater 2 is malfunctioning, which may be due to poor connector contact." }, { "ecode": "0705230000020022", "intro": "AMS F slot 4 assist motor is stalled,due to excessive resistance in the tube near the toolhead." }, { "ecode": "180120000002000A", "intro": "Failed to adjust the filament position of AMS-HT B Slot 1. The filament or buffer may be stuck." }, { "ecode": "1801730000020002", "intro": "Failed to feed the AMS-HT B Slot 4 filament into the Toolhead. Possible cause: filament or spool stuck." }, { "ecode": "1800200000020023", "intro": "AMS-HT A slot 1 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "1803720000020001", "intro": "Failed to pull out the AMS-HT D Slot 3 filament from the extruder. Possible cause: clogged extruder or broken filament inside the extruder." }, { "ecode": "0703600000020001", "intro": "The AMS D Slot 1 is overloaded. The filament may be tangled or the filament buffer may be stuck." }, { "ecode": "1802230000020023", "intro": "AMS-HT C slot 4 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0707220000020012", "intro": "AMS H slot 3 feeder unit motor is stalled, cannot rotate the spool." }, { "ecode": "0703220000020008", "intro": "AMS D Slot 3 feed-in Hall sensor is disconnected, which may be due to poor connector contact." }, { "ecode": "1803220000010082", "intro": "Failed to read the filament information from AMS-HT D slot 3. A non-official RFID tag was detected. You can try to use Bambu Lab filament." }, { "ecode": "1806230000020021", "intro": "AMS-HT G slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "1802200000020014", "intro": "AMS-HT C slot 1 filament odometer has no signal, which may be due to poor contact in the odometer connector or a odometer fault." }, { "ecode": "1802220000020002", "intro": "AMS-HT C Slot 3 is empty; please insert a new filament." }, { "ecode": "0700230000020021", "intro": "AMS A slot 4 assist motor is stalled,due to excessive resistance in the tube between the filament buffer and the toolhead." }, { "ecode": "0705010000010005", "intro": "AMS F The current sensor of assist motor may be faulty." }, { "ecode": "1803200000020024", "intro": "AMS-HT D slot 1 failed to rotate the filament spool when pulling filament back to AMS." }, { "ecode": "0706930000020002", "intro": "AMS G The cooling fan speed of heater 2 is too low, which could be due to excessive fan resistance." }, { "ecode": "0700800000010003", "intro": "AMS A The heater 1 is short-circuited, which may be due to a wiring short or heater damage." }, { "ecode": "1803230000020002", "intro": "AMS-HT D Slot 4 is empty; please insert a new filament." }, { "ecode": "0707230000010081", "intro": "Failed to read the filament information from AMS H slot 4. The AMS main board may be malfunctioning." }, { "ecode": "1804130000010003", "intro": "The AMS-HT E slot 4 motor torque control is malfunctioning. The current sensor may be faulty." }, { "ecode": "1200230000030002", "intro": "AMS A Slot4 filament has run out and automatically switched to the slot with the same filament." }, { "ecode": "0700220000020023", "intro": "AMS A slot 3 the tube inside the AMS is broken, or feed-out hall sensor is faulty and cannot detect the filament." }, { "ecode": "0703700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0703700000020006", "intro": "Timeout purging old filament. Possible cause: filament stuck or the extruder/nozzle clog." }, { "ecode": "0C00040000020006", "intro": "" }, { "ecode": "0704300000020002", "intro": "The RFID-tag on AMS E Slot1 is damaged, or its content cannot be identified." }, { "ecode": "1807300000010001", "intro": "The AMS-HT H RFID 1 board has an error." }, { "ecode": "0C00040000020030", "intro": "The rotary engraving accessory is placed incorrectly. Please adjust and reposition it." }, { "ecode": "0700F40000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 5 is correctly installed." }, { "ecode": "0700F30000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 4 is correctly installed." }, { "ecode": "0700F50000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 6 is correctly installed." }, { "ecode": "0700F20000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 3 is correctly installed." }, { "ecode": "0700F10000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 2 is correctly installed." }, { "ecode": "1A00040000020032", "intro": "Error detected while fetching the hotend from slot 4: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00010000020033", "intro": "Error detected while fetching the hotend from slot 1: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00060000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 6: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00050000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 5: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 5 on the rack, and then click “Continue.”" }, { "ecode": "1A00020000020032", "intro": "Error detected while fetching the hotend from slot 2: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00030000020032", "intro": "Error detected while fetching the hotend from slot 3: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00030000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 3: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00030000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 3: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00020000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 2: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00020000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 2: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00060000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 6: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 6 on the rack, and then click “Continue.”" }, { "ecode": "1A00060000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 6: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00060000020036", "intro": "Error detected while fetching the hotend from slot 6: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00050000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 5: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00040000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 4: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00030000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 3: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00010000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 1: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00010000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 1: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00040000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 4: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 4 on the rack, and then click “Continue.”" }, { "ecode": "1A00010000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 1: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00020000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 2: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00050000020035", "intro": "Error detected while fetching the hotend from slot 5: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00030000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 3: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00060000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 6: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00020000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 2: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 2 on the rack, and then click “Continue.”" }, { "ecode": "1A00020000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 2. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 2 on the rack before clicking “Continue.”" }, { "ecode": "1A00040000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 4: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00050000020033", "intro": "Error detected while fetching the hotend from slot 5: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00030000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 3. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 3 on the rack before clicking “Continue.”" }, { "ecode": "1A00010000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 1: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00010000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 1: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00030000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 3: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00060000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 6. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 6 on the rack before clicking “Continue.”" }, { "ecode": "1A00010000020035", "intro": "Error detected while fetching the hotend from slot 1: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00050000020034", "intro": "Error detected while fetching the hotend from slot 5: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 5 on the rack and click “Continue.”" }, { "ecode": "1A00030000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 3: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00040000020036", "intro": "Error detected while fetching the hotend from slot 4: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00030000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 3: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 3 on the rack, and then click “Continue.”" }, { "ecode": "1A00120000020007", "intro": "The hotend rack motion timed out. Please check for any foreign objects or obstructions that may be causing the rack to jam." }, { "ecode": "1A00060000020033", "intro": "Error detected while fetching the hotend from slot 6: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00030000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 3: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00050000020032", "intro": "Error detected while fetching the hotend from slot 5: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00040000020035", "intro": "Error detected while fetching the hotend from slot 4: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00020000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 2: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00040000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 4: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00050000020036", "intro": "Error detected while fetching the hotend from slot 5: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00010000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 1: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00060000020034", "intro": "Error detected while fetching the hotend from slot 6: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 6 on the rack and click “Continue.”" }, { "ecode": "1A00020000020033", "intro": "Error detected while fetching the hotend from slot 2: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00010000020025", "intro": "Abnormal condition detected while nesting the hotend in slot 1: the hotend has dropped. Please check for excessive filament remaining at the top of the hotend, trim the residue, reinstall the hotend into slot 1 on the rack, and then click “Continue.”" }, { "ecode": "1A00040000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 4. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 4 on the rack before clicking “Continue.”" }, { "ecode": "1A00050000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 5: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00010000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 1: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00020000020020", "intro": "Abnormal condition detected while nesting the hotend in slot 2: a hotend is already installed. Please remove the existing one before clicking “Continue.”" }, { "ecode": "1A00060000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 6: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00040000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 4: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00050000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 5: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00030000020035", "intro": "Error detected while fetching the hotend from slot 3: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00040000020033", "intro": "Error detected while fetching the hotend from slot 4: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00030000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 3: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00060000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 6: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00050000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 5: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00050000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 5: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00020000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 2: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00040000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 4: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00060000020035", "intro": "Error detected while fetching the hotend from slot 6: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00120000020008", "intro": "The hotend rack tool lock rod position is abnormal. Please check for any foreign objects or obstructions that may be causing the lock rod to jam." }, { "ecode": "1A00010000020032", "intro": "Error detected while fetching the hotend from slot 1: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00010000020034", "intro": "Error detected while fetching the hotend from slot 1: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 1 on the rack and click “Continue.”" }, { "ecode": "1A00060000020032", "intro": "Error detected while fetching the hotend from slot 6: the toolhead failed to detect the hotend on the rack. Please check for any debris in the induction hotend mounting slot on the toolhead. If none is found, recalibrate the induction hotend rack." }, { "ecode": "1A00010000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 1. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 1 on the rack before clicking “Continue.”" }, { "ecode": "1A00040000020030", "intro": "Abnormal condition detected while fetching the hotend from slot 4: no hotend found in this position. Please install a hotend in the corresponding slot before clicking “Continue.”" }, { "ecode": "1A00030000020036", "intro": "Error detected while fetching the hotend from slot 3: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00040000020034", "intro": "Error detected while fetching the hotend from slot 4: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 4 on the rack and click “Continue.”" }, { "ecode": "1A00120000020009", "intro": "Induction hotend locking lever or rack lever release mechanism error. Please refer to the Wiki for inspection." }, { "ecode": "1A00020000020034", "intro": "Error detected while fetching the hotend from slot 2: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 2 on the rack and click “Continue.”" }, { "ecode": "1A00060000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 6: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00010000020036", "intro": "Error detected while fetching the hotend from slot 1: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00010000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 1: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00020000020026", "intro": "Abnormal condition detected while nesting the hotend in slot 2: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00050000020022", "intro": "Abnormal condition detected while nesting the hotend in slot 5. Please ensure no hotend is mounted on the toolhead and that a hotend is present in slot 5 on the rack before clicking “Continue.”" }, { "ecode": "1A00050000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 5: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00040000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 4: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00050000020027", "intro": "Abnormal condition detected while nesting the hotend in slot 5: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00040000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 4: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00030000020033", "intro": "Error detected while fetching the hotend from slot 3: the rack failed to mount the hotend properly. Please check for excessive filament at the top of the hotend, debris in the contact area between the toolhead and the hotend, or if the locking lever is in the released position. After resolving the issue, click “Continue.”" }, { "ecode": "1A00020000020021", "intro": "Abnormal condition detected while nesting the hotend in slot 2: no hotend detected on the toolhead. Please mount the hotend onto the toolhead before clicking “Continue.”" }, { "ecode": "1A00020000020035", "intro": "Error detected while fetching the hotend from slot 2: rack movement is blocked. Please check for any foreign objects, remove them, and then click “Continue.”" }, { "ecode": "1A00020000020036", "intro": "Error detected while fetching the hotend from slot 2: toolhead recentering retry failed. Please manually move the toolhead to the center of the build plate and then click “Continue.”" }, { "ecode": "1A00060000020024", "intro": "Abnormal condition detected while nesting the hotend in slot 6: the rack failed to detach the hotend from the toolhead. Please make sure the locking lever is in the released position." }, { "ecode": "1A00030000020034", "intro": "Error detected while fetching the hotend from slot 3: the hotend has dropped. Please check for excessive filament or other debris at the top of the hotend, trim or remove it, then reinstall the hotend into slot 3 on the rack and click “Continue.”" }, { "ecode": "1A00050000020023", "intro": "Abnormal condition detected while nesting the hotend in slot 5: the rack failed to detect the hotend on the toolhead. Please check whether there is any debris on the hotend heatsink surface or if the front magnet has fallen off. If not, recalibrate the induction hotend rack." }, { "ecode": "1A00060000020031", "intro": "Abnormal condition detected while fetching the hotend from slot 6: a hotend is already mounted on the toolhead. Please remove the hotend from the toolhead before clicking “Continue.”" }, { "ecode": "1A00120000020011", "intro": "Induction hotend not detected before locking. Please check its installation on the toolhead." }, { "ecode": "1800980000020002", "intro": "AMS-HT A The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0C00010000010004", "intro": "Toolhead Camera lens seems to be dirty. Please clean the lens." }, { "ecode": "1803400000020001", "intro": "AMS-HT D Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0580050000010017", "intro": "AMS-HT A certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0583040000010045", "intro": "The firmware of AMS-HT D does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0701400000020001", "intro": "AMS B Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0585040000010045", "intro": "The firmware of AMS-HT F does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0C00010000010001", "intro": "Toolhead Camera is offline. Please check the hardware connection." }, { "ecode": "0702980000020002", "intro": "AMS C The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0500050000010014", "intro": "AMS A certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1807980000020002", "intro": "AMS-HT H The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "1801980000020002", "intro": "AMS-HT B The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0581040000010045", "intro": "The firmware of AMS-HT B does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0C0003000003001A", "intro": "" }, { "ecode": "0707980000020001", "intro": "AMS H The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0585050000010017", "intro": "AMS-HT F certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1802980000020001", "intro": "AMS-HT C The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0503050000010014", "intro": "AMS D certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0701980000020001", "intro": "AMS B The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0500040000010046", "intro": "The firmware of Laser Module does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0500050000010016", "intro": "Cutting module certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1801400000020001", "intro": "AMS-HT B Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0702980000020001", "intro": "AMS C The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0501050000010014", "intro": "AMS B certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0500050000010013", "intro": "Laser module certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0501040000010044", "intro": "The firmware of AMS B does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0707980000020002", "intro": "AMS H The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "1803980000020002", "intro": "AMS-HT D The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0300390000010001", "intro": "The External Fan on the Toolhead is running too slowly or has stopped, possibly due to debris blockage or a loose connector." }, { "ecode": "0705400000020001", "intro": "AMS F Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0C0003000003001B", "intro": "Possible spaghetti defects were detected. Please check the print quality and decide if the job should be stopped." }, { "ecode": "0580040000010045", "intro": "The firmware of AMS-HT A does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0C0003000002001C", "intro": "Your nozzle seems to be covered with jammed or clogged material." }, { "ecode": "1802980000020002", "intro": "AMS-HT C The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0703980000020002", "intro": "AMS D The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0706980000020001", "intro": "AMS G The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "1805400000020001", "intro": "AMS-HT F Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "1805980000020001", "intro": "AMS-HT F The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "1803980000020001", "intro": "AMS-HT D The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0706400000020001", "intro": "AMS G Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0702400000020001", "intro": "AMS C Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0706980000020002", "intro": "AMS G The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0500040000010048", "intro": "The firmware of Cutting Module does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "030001000003000F", "intro": "The chamber temperature is currently high, and the heatbed is cooling down slowly. It is recommended to open the top cover or front door to accelerate the cooling process." }, { "ecode": "0704980000020001", "intro": "AMS E The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "1801980000020001", "intro": "AMS-HT B The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0500040000010044", "intro": "The firmware of AMS A does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0703400000020001", "intro": "AMS D Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0C00040000010025", "intro": "The device malfunctioned; please restart." }, { "ecode": "0C00040000020026", "intro": "Liveview Camera initialization failed, and some AI functions such as Spaghetti Detection will be disabled. Please restart the printer. If the problem persists, please contact customer support." }, { "ecode": "0704400000020001", "intro": "AMS E Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0587050000010017", "intro": "AMS-HT H certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0502050000010014", "intro": "AMS C certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0704980000020002", "intro": "AMS E The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0705980000020001", "intro": "AMS F The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0707400000020001", "intro": "AMS H Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "030001000002000F", "intro": "The chamber target temperature is set too high, while the heatbed target temperature is set too low. Heatbed cooling has been skipped. It is recommended to set matching chamber and heatbed temperatures." }, { "ecode": "1806980000020002", "intro": "AMS-HT G The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "1805980000020002", "intro": "AMS-HT F The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0587040000010045", "intro": "The firmware of AMS-HT H does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0586040000010045", "intro": "The firmware of AMS-HT G does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0582050000010017", "intro": "AMS-HT C certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1806400000020001", "intro": "AMS-HT G Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0300A40000010008", "intro": "The chamber temperature sensor is abnormal. Please troubleshoot the issue before restarting the task." }, { "ecode": "1800980000020001", "intro": "AMS-HT A The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "1804980000020001", "intro": "AMS-HT E The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0503040000010044", "intro": "The firmware of AMS D does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0703980000020001", "intro": "AMS D The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0705980000020002", "intro": "AMS F The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0300390000020002", "intro": "The External Fan on the Toolhead is running at a low speed, possibly due to debris buildup." }, { "ecode": "0586050000010017", "intro": "AMS-HT G certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0500050000010015", "intro": "Air Pump certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1802400000020001", "intro": "AMS-HT C Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0582040000010045", "intro": "The firmware of AMS-HT C does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0701980000020002", "intro": "AMS B The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0581050000010017", "intro": "AMS-HT B certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1804400000020001", "intro": "AMS-HT E Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0583050000010017", "intro": "AMS-HT D certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "1804980000020002", "intro": "AMS-HT E The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0500040000010047", "intro": "The firmware of Air Pump does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0584050000010017", "intro": "AMS-HT E certification failed. Please reconnect the cable or restart the printer." }, { "ecode": "0502040000010044", "intro": "The firmware of AMS C does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1807400000020001", "intro": "AMS-HT H Filament buffer position signal lost: the cable or position sensor may be malfunctioning." }, { "ecode": "0700980000020002", "intro": "AMS A The power adapter voltage is too high, which may damage the heater circuit. Please replace the power adapter." }, { "ecode": "0C00010000010005", "intro": "Toolhead Camera parameter is abnormal. Please contact customer support." }, { "ecode": "0C00010000010003", "intro": "Synchronization between the Toolhead Camera and MC is abnormal. Please restart your printer." }, { "ecode": "0700980000020001", "intro": "AMS A The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "0584040000010045", "intro": "The firmware of AMS-HT E does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "1807980000020001", "intro": "AMS-HT H The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "1806980000020001", "intro": "AMS-HT G The power adapter voltage is too low, which may result in insufficient drying temperature. Please replace the power adapter." }, { "ecode": "050003000001000E", "intro": "Some external modules are incompatible with the printer's firmware version, which may affect normal operation. Please go to the \"Firmware\" page while connected to the internet to upgrade." }, { "ecode": "0702210000020006", "intro": "AMS C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1802210000020006", "intro": "AMS-HT C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0701210000020006", "intro": "AMS B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1803210000020006", "intro": "AMS-HT D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0703210000020006", "intro": "AMS D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "030095000001000A", "intro": "The ambient temperature sensor at the bottom of the laser module is abnormal; the sensor has an open circuit." }, { "ecode": "0704220000020006", "intro": "AMS E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1802230000020006", "intro": "AMS-HT C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0703220000020006", "intro": "AMS D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "18FF700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0500030000020055", "intro": "User information has expired, please log in again." }, { "ecode": "1803230000020006", "intro": "AMS-HT D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1801220000020006", "intro": "AMS-HT B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1801210000020006", "intro": "AMS-HT B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0704230000020006", "intro": "AMS E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0707210000020006", "intro": "AMS H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1805210000020006", "intro": "AMS-HT F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1801230000020006", "intro": "AMS-HT B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1806230000020006", "intro": "AMS-HT G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0704210000020006", "intro": "AMS E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0707230000020006", "intro": "AMS H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0700230000020006", "intro": "AMS A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "18FE700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "03002C0000010001", "intro": "Obstacle detected under the heatbed. Please remove it to ensure proper printing." }, { "ecode": "1806210000020006", "intro": "AMS-HT G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "07FF450000020001", "intro": "The right filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in." }, { "ecode": "0707220000020006", "intro": "AMS H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0706230000020006", "intro": "AMS G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1800230000020006", "intro": "AMS-HT A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "07FF700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1803220000020006", "intro": "AMS-HT D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "07FE450000020001", "intro": "The left filament cutter sensor is malfunctioning; please check whether the connector is properly plugged in." }, { "ecode": "1804220000020006", "intro": "AMS-HT E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0701230000020006", "intro": "AMS B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1806220000020006", "intro": "AMS-HT G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0300950000010009", "intro": "The ambient temperature sensor at the bottom of the laser module is abnormal; the sensor is short-circuited." }, { "ecode": "0700210000020006", "intro": "AMS A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1807220000020006", "intro": "AMS-HT H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "050003000002000E", "intro": "Some modules are incompatible with the printer's firmware version, which may affect use. Please go to the \"Firmware\" page to update after connected to the internet, or you may update offline according to wiki." }, { "ecode": "1800210000020006", "intro": "AMS-HT A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0705220000020006", "intro": "AMS F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0703230000020006", "intro": "AMS D has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1804230000020006", "intro": "AMS-HT E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "07FE700000020008", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1805230000020006", "intro": "AMS-HT F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0300270000010005", "intro": "The nozzle offset calibration indicates significant deviation, possibly caused by an additional heat insulation sheet installed on the right nozzle heating base. Please verify this and attempt the calibration again." }, { "ecode": "0300270000010006", "intro": "The nozzle offset calibration shows significant deviation, possibly due to incorrect installation of the nozzle or heating base. Please inspect and retry." }, { "ecode": "1807230000020006", "intro": "AMS-HT H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0705210000020006", "intro": "AMS F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0300270000010003", "intro": "The nozzle offset calibration result shows significant deviation, possibly due to the heat insulation sheet on the right nozzle heating base not being installed. Please install it correctly and try again." }, { "ecode": "0700220000020006", "intro": "AMS A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1805220000020006", "intro": "AMS-HT F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1807210000020006", "intro": "AMS-HT H has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0300A70000030001", "intro": "The chamber temperature is high, and the system has increased the fan speed, which may cause more noise. It’s recommended to lower the room temperature or open the front door/top cover to help cool it down." }, { "ecode": "0702220000020006", "intro": "AMS C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0701220000020006", "intro": "AMS B has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0706220000020006", "intro": "AMS G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1804210000020006", "intro": "AMS-HT E has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0706210000020006", "intro": "AMS G has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1800220000020006", "intro": "AMS-HT A has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0702230000020006", "intro": "AMS C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0705230000020006", "intro": "AMS F has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "1802220000020006", "intro": "AMS-HT C has detected a breakage of the PTFE tube during filament loading. Please check whether the PTFE tubes inside and outside the AMS have fallen off or been damaged." }, { "ecode": "0701900000010004", "intro": "The current sensor of AMS B exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0707910000010004", "intro": "The current sensor of AMS H exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1803900000010004", "intro": "The current sensor of AMS-HT D exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1807910000010004", "intro": "The current sensor of AMS-HT H exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1800910000010004", "intro": "The current sensor of AMS-HT A exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1800900000010004", "intro": "The current sensor of AMS-HT A exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0704900000010004", "intro": "The current sensor of AMS E exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1803910000010004", "intro": "The current sensor of AMS-HT D exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0705900000010004", "intro": "The current sensor of AMS F exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1805900000010004", "intro": "The current sensor of AMS-HT F exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0706900000010004", "intro": "The current sensor of AMS G exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1804900000010004", "intro": "The current sensor of AMS-HT E exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0707900000010004", "intro": "The current sensor of AMS H exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1802900000010004", "intro": "The current sensor of AMS-HT C exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1805910000010004", "intro": "The current sensor of AMS-HT F exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1804910000010004", "intro": "The current sensor of AMS-HT E exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1806900000010004", "intro": "The current sensor of AMS-HT G exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0700910000010004", "intro": "The current sensor of AMS A exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0702900000010004", "intro": "The current sensor of AMS C exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "03002D0000030009", "intro": "Performing initial High-temperature Bed Leveling." }, { "ecode": "0706910000010004", "intro": "The current sensor of AMS G exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0701910000010004", "intro": "The current sensor of AMS B exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1801910000010004", "intro": "The current sensor of AMS-HT B exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1806910000010004", "intro": "The current sensor of AMS-HT G exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "0703910000010004", "intro": "The current sensor of AMS D exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0700900000010004", "intro": "The current sensor of AMS A exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0704910000010004", "intro": "The current sensor of AMS E exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0705910000010004", "intro": "The current sensor of AMS F exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0702910000010004", "intro": "The current sensor of AMS C exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "0703900000010004", "intro": "The current sensor of AMS D exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS mainboard." }, { "ecode": "1801900000010004", "intro": "The current sensor of AMS-HT B exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1807900000010004", "intro": "The current sensor of AMS-HT H exhaust valve 1 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1802910000010004", "intro": "The current sensor of AMS-HT C exhaust valve 2 is abnormal; please get in touch with customer support to replace the AMS-HT mainboard." }, { "ecode": "1A00230000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 3 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "1A00010000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 1 on the rack." }, { "ecode": "030002000001000B", "intro": "The right extruder nozzle temperature control is abnormal, possibly due to the hotend not being properly installed or a malfunction of the wireless temperature measurement board." }, { "ecode": "1A00210000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 1 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00210000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 1 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "0300E00000010002", "intro": "Inter-phase short circuit on hotend holder motor. If restarting doesn’t resolve the issue, please contact support." }, { "ecode": "1A00040000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 4 on the rack." }, { "ecode": "1A00220000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 2 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "1A00210000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 1 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "1A00250000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 5 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "1A00020000020001", "intro": "Error fetching/nesting the hotend in rack slot 2. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00030000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 3 on the rack. Please remove it before continuing." }, { "ecode": "1A00060000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 6 on the rack." }, { "ecode": "1A00250000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 5 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "1A00020000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 2 on the rack. Please remove it before continuing." }, { "ecode": "1A00240000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 4 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00050000020001", "intro": "Error fetching/nesting the hotend in rack slot 5. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00220000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 2 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "1A00060000020001", "intro": "Error fetching/nesting the hotend in rack slot 6. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00230000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 3 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "0300E20000020001", "intro": "Communication error between the hotend holder motor and the position sensor. If restarting fails, please contact customer support." }, { "ecode": "1A00100000020001", "intro": "Toolhead XY axis or hotend rack has not finished homing. Hotend replacement cannot proceed." }, { "ecode": "1A00240000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 4 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "1A00240000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 4 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "0300E00000010004", "intro": "Hotend holder motor is stalled. Please check for foreign objects or collisions with the toolhead." }, { "ecode": "0300E10000010001", "intro": "Current sensor fault on hotend holder motor. This may be caused by a sampling circuit failure. If restarting the printer doesn’t resolve the issue, please contact customer support." }, { "ecode": "1A00040000020001", "intro": "Error fetching/nesting the hotend in rack slot 4. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00E00000010006", "intro": "Induction Hotend Rack homing distance is too long. The timing belt may be loose. Please check and tighten." }, { "ecode": "1A00260000010002", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend from slot 6 on the rack back onto the toolhead, then move the toolhead to the center of the build plate." }, { "ecode": "1A00240000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 4 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "1A00030000020001", "intro": "Error fetching/nesting the hotend in rack slot 3. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00010000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 1 on the rack. Please remove it before continuing." }, { "ecode": "1A00010000020001", "intro": "Error fetching/nesting the hotend in rack slot 1. Ensure the hotend holder has no hotend installed, the corresponding rack slot contains a hotend, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00250000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 5 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "1A00030000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 3 on the rack." }, { "ecode": "1A00250000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 5 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00260000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 6 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "1A00050000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 5 on the rack." }, { "ecode": "1A00060000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 6 on the rack. Please remove it before continuing." }, { "ecode": "1A00040000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 4 on the rack. Please remove it before continuing." }, { "ecode": "1A00230000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 3 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "1A00210000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 1 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "0300E30000010001", "intro": "The MOS tubes of the Hotend Holder motor drive board are short-circuited. If restarting the printer does not resolve the problem, please contact customer support." }, { "ecode": "1A00110000020003", "intro": "Induction Hotend Rack coarse homing failed due to excessive travel. Please check the timing belt condition." }, { "ecode": "1A00200000020001", "intro": "Power outage occurred during hotend replacement. Please follow the Wiki guide to restore the setup, otherwise printing may fail." }, { "ecode": "0300E30000010002", "intro": "MC communication with hotend holder motor driver failed. Please check if the connection cable is properly plugged in." }, { "ecode": "050003000001000D", "intro": "The induction hotend rack is malfunctioning. Please power off, check the connection, and restart the device." }, { "ecode": "1A00050000020004", "intro": "Error detected before induction hotend replacement: a hotend is already installed in slot 5 on the rack. Please remove it before continuing." }, { "ecode": "1A00220000010001", "intro": "Power loss occurred while fetching/nesting the hotend. Please nest the hotend back to slot 2 on the rack, then move the toolhead to the center of the build plate." }, { "ecode": "1A00230000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 3 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00E00000010005", "intro": "The Induction Hotend Rack is blocked by an obstacle during homing. Please clear any obstructions from its movement path." }, { "ecode": "1A00220000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 2 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00110000020002", "intro": "Hotend rack coarse homing failed. Please check for any obstructions." }, { "ecode": "0300E00000010003", "intro": "Hotend holder motor has abnormal or unbalanced three-phase resistance. If restarting doesn’t help, please contact support." }, { "ecode": "0300A60000010002", "intro": "The Toolhead Enhanced Cooling Fan has lost communication; please check the connector." }, { "ecode": "0300E00000010001", "intro": "Hotend holder motor is disconnected or has an open-circuit fault. Please check the motor’s flat cable connection." }, { "ecode": "1A00020000020003", "intro": "Error detected before induction hotend replacement: no hotend installed in slot 2 on the rack." }, { "ecode": "0300A60000010001", "intro": "The Toolhead Enhanced Cooling Fan is not properly installed; it may not be securely fastened or may have fallen off." }, { "ecode": "1A00260000020001", "intro": "Power loss occurred while fetching/nesting hotend. Check if the hotend is in slot 6 on the rack. If not, nest it back to that slot and move the toolhead to the center of the build plate." }, { "ecode": "1A00260000020002", "intro": "Power loss occurred while fetching/nesting the hotend. Check if it’s mounted on the toolhead. If not, fetch it from slot 6 on the rack, nest it onto the toolhead, and move the toolhead to the center of the build plate." }, { "ecode": "0702960000020004", "intro": "AMS C The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1800960000020004", "intro": "AMS-HT A The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0704960000020004", "intro": "AMS E The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1801250000020001", "intro": "AMS-HT B uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1803250000020001", "intro": "AMS-HT D uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1807250000020001", "intro": "AMS-HT H uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1806250000020001", "intro": "AMS-HT G uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0703960000020004", "intro": "AMS D The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0707960000020004", "intro": "AMS H The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1802960000020004", "intro": "AMS-HT C The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1803960000020004", "intro": "AMS-HT D The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0706960000020004", "intro": "AMS G The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1804960000020004", "intro": "AMS-HT E The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0701960000020004", "intro": "AMS B The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1807960000020004", "intro": "AMS-HT H The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1804250000020001", "intro": "AMS-HT E uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1805960000020004", "intro": "AMS-HT F The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1805250000020001", "intro": "AMS-HT F uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1800250000020001", "intro": "AMS-HT A uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "1801960000020004", "intro": "AMS-HT B The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1806960000020004", "intro": "AMS-HT G The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "1802250000020001", "intro": "AMS-HT C uses printer power for drying during loading/printing. For better drying performance, please connect a power adapter." }, { "ecode": "0700960000020004", "intro": "AMS A The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0705960000020004", "intro": "AMS F The temperature control error is too large, which may be due to the lid being open or an abnormality with the heater." }, { "ecode": "0500050000010019", "intro": "Fire Extinguisher module certification failed. Please reconnect the module cable or restart the printer." }, { "ecode": "0500050000010018", "intro": "Laser Fourth Axis module certification failed. Please reconnect the module cable or restart the printer." }, { "ecode": "0300D10000010002", "intro": "Fire extinguisher motor error. Please power off and then power on to restart the extinguisher." }, { "ecode": "0300D10000010001", "intro": "Fire extinguisher motor has an open-circuit. There may be a loose connection, or the motor may have failed." }, { "ecode": "0300D40000010002", "intro": "The fire extinguisher presence detection sensor is malfunctioning. Please check if the sensor cable is loose or damaged." }, { "ecode": "0300D30000020001", "intro": "Fire extinguisher not detected. Please ensure the signal cable is securely connected and the plug is fully inserted." }, { "ecode": "0300D60000010006", "intro": "Fire extinguisher motor reset failed. Please power off and then power on to restart the extinguisher." }, { "ecode": "0C0001000002000E", "intro": "" }, { "ecode": "0500030000010053", "intro": "" }, { "ecode": "0300D60000010007", "intro": "The fire extinguisher motor reset is jammed. Please gently turn the emergency handwheel left and right until the resistance decreases. Then, power off the fire extinguisher and turn it back on." }, { "ecode": "03002D0000010006", "intro": "Heated bed leveling failed, possibly due to foreign objects on the bed or bed tilt. Continuing to print may damage the build plate. Please remove any debris or manually level the bed before retrying." }, { "ecode": "0300D50000020004", "intro": "Fire extinguisher cylinder not installed. Please confirm on the extinguisher page." }, { "ecode": "0300D50000020005", "intro": "The Fire Extinguisher Gas Cylinder is empty. Please replace the gas cylinder and then confirm the replacement on the Auto Fire Extinguishing System page." }, { "ecode": "0C00040000030028", "intro": "The Cutting Module offset calibration failed, which may result in inaccurate cuts. Please ensure the 80g white printer paper(letter paper thickness) is properly positioned and check whether the cutting blade tip is worn." }, { "ecode": "0C00040000030026", "intro": "To improve flame detection accuracy, the right chamber light has been automatically turned off." }, { "ecode": "0500040000030054", "intro": "Auto Fire Extinguishing System detected. It is recommended to conduct a Fire Drill to become familiar with the operation process." }, { "ecode": "0300270000010002", "intro": "Too many attempts at nozzle offset calibration, possibly due to purged filament between the nozzle and the heated base, or incorrect installation of the nozzle. Please inspect and retry." }, { "ecode": "0501040000030004", "intro": "Please clean and lubricate the X-axis linear rail, YZ-axis linear rods, and the extruder lift linear rail." }, { "ecode": "0300270000010008", "intro": "The nozzle offset calibration sensor signal is too weak. It may be that the nozzle is sticky or the nozzle does not move above the sensor during calibration, causing the distance between the nozzle and the sensor to be too far." }, { "ecode": "0501040000030010", "intro": "Laser module is dusty and needs cleaning now." }, { "ecode": "0501040000030002", "intro": "Threaded rods need lubrication now." }, { "ecode": "030025000001000C", "intro": "An anomalous jump in the right extruder extrusion force sensor data has been detected, potentially caused by poor sensor contact or a faulty sensor." }, { "ecode": "030026000001000C", "intro": "An anomalous jump in the left extruder extrusion force sensor data has been detected, potentially caused by poor sensor contact or a faulty sensor." }, { "ecode": "0C00040000020029", "intro": "The Laser or Cutting module has not been calibrated. Please calibrate it on the printer first." }, { "ecode": "0500050000020030", "intro": "" }, { "ecode": "0500050000010020", "intro": "Hotend 1 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "1A00120000020002", "intro": "Induction hotend rack calibration failed: the white marker on the rack’s induction hotend docking module was not detected. Please refer to the Wiki to check if the marker is damaged or covered by dirt." }, { "ecode": "0504050000010020", "intro": "Hotend 5 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "1A00120000020003", "intro": "Induction hotend rack calibration failed: abnormal calibration result. Please refer to the Wiki to check if the rack structure is deformed." }, { "ecode": "0503050000010020", "intro": "Hotend 4 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "0501050000010020", "intro": "Hotend 2 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "0500050000010021", "intro": "Time-lapse kit authentication failed. Please reconnect the cable or restart the printer." }, { "ecode": "0502050000010020", "intro": "Hotend 3 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "1A00120000020001", "intro": "Induction hotend rack calibration failed: camera position calibration error. Please clean any debris from the thermal paper surface at the rear of the build plate and remove residue from the nozzle." }, { "ecode": "0505050000010020", "intro": "Hotend 6 authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "0C00020000010001", "intro": "The height measuring laser is not lit. Please check if it is blocked or if the connection cable is disconnected." }, { "ecode": "0300D70000020001", "intro": "Laser fourth axis is not connected" }, { "ecode": "0300D80000010002", "intro": "Laser fourth axis motor error. Please power off and then power on to restart the laser fourth axis." }, { "ecode": "0300020000010004", "intro": "The right nozzle temperature control is abnormal. The hotend might have structural damage." }, { "ecode": "0300D80000010001", "intro": "Laser fourth axis motor has an open-circuit. There may be a loose connection, or the motor may have failed." }, { "ecode": "0501040000030006", "intro": "The Induction Hotend Latch may be worn. To ensure proper induction hotend switching, please replace the Induction Hotend Latch and clean the rods of Induction Hotend Rack." }, { "ecode": "1A00120000020010", "intro": "The Induction Hotend Rack has not been set up. Please follow the instructions to complete the setup before using its functions." }, { "ecode": "0300AB0000010001", "intro": "The right hotend heatbreak temperature is too high, which may cause clogging. Please open the printer’s top cover and front door to reduce the chamber temperature, or lower the ambient temperature." }, { "ecode": "0300020000010009", "intro": "The right nozzle temperature control is abnormal. The hotend is not installed." }, { "ecode": "0501040000030005", "intro": "Please clean and lubricate the Induction Hotend Latch and the linear rods of the Hotend Change System." }, { "ecode": "0503000000030027", "intro": "" }, { "ecode": "0503000000030028", "intro": "" }, { "ecode": "0503000000030029", "intro": "" }, { "ecode": "0500040000010056", "intro": "" }, { "ecode": "070570000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180070000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180470000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "070770000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0500070000020201", "intro": "" }, { "ecode": "1A00120000020004", "intro": "Hotend rack height calibration is abnormal. Please check for any foreign objects that may be causing the rack to jam." }, { "ecode": "07FE70000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "18FF70000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0300AB0000020002", "intro": "The right hotend heatbreak temperature is relatively high, which may cause nozzle clogging. Please open the printer’s top cover and front door to reduce the chamber temperature, or lower the ambient temperature." }, { "ecode": "070470000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0500070000020002", "intro": "" }, { "ecode": "070170000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "070370000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "070270000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "070070000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180270000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "1A00130000020001", "intro": "The hotend rack is fully occupied. Please remove at least one hotend before proceeding." }, { "ecode": "070670000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0500070000020001", "intro": "" }, { "ecode": "07FF70000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180370000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0500070000020003", "intro": "" }, { "ecode": "0300D90000020001", "intro": "Communication error between the laser fourth axis motor and the position sensor. If restarting fails, please contact customer support." }, { "ecode": "180670000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180170000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180770000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "180570000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0500070000020101", "intro": "" }, { "ecode": "18FE70000002000A", "intro": "Failed to get filament-hotend mapping table from the slicing file." }, { "ecode": "0704260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS E will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1A00030000020002", "intro": "Error fetching/nesting the hotend in rack slot 3. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00010000020002", "intro": "Error fetching/nesting the hotend in rack slot 1. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00060000020002", "intro": "Error fetching/nesting the hotend in rack slot 6. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1A00050000020002", "intro": "Error fetching/nesting the hotend in rack slot 5. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1804260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT E will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0702260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS C will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0700260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS A will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1A00040000020002", "intro": "Error fetching/nesting the hotend in rack slot 4. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "0701260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS B will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1801260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT B will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1800260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT A will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1805260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT F will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1A00020000020002", "intro": "Error fetching/nesting the hotend in rack slot 2. Ensure the hotend holder has a hotend installed, the corresponding rack slot is empty, and manually move the toolhead to the machine center before continuing." }, { "ecode": "1803260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT D will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0707260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS H will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1806260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT G will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0703260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS D will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1802260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT C will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0706260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS G will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "1807260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS-HT H will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0705260000020001", "intro": "The induction hotend is heating up, and the drying power of AMS F will be reduced. Please connect the power adapter or wait until the hotend finishes heating." }, { "ecode": "0300020000010001", "intro": "Right extruder nozzle temperature error. The heater coil may be short-circuited. Please check if the insulation layer is intact." }, { "ecode": "0300020000010002", "intro": "Right extruder nozzle temperature error. The heater coil may be open-circuited. Please check if the connector is loose." }, { "ecode": "0300020000010003", "intro": "Right extruder nozzle temperature error. The heater core may be overheating." }, { "ecode": "0300020000010008", "intro": "The right nozzle temperature control is abnormal and is unable to heat up to the preset temperature." }, { "ecode": "0300DA0000020001", "intro": "Laser module detected. Please remove the hotend from the hotend rack to prevent laser processing debris from affecting printing performance." }, { "ecode": "0300DB0000020001", "intro": "Laser module detected. Please install the right nozzle correctly to ensure proper Laser Module Mounting Calibration." }, { "ecode": "0700F00000020001", "intro": "Filament and hotend matching failed. Please verify that the hotend in the hotend rack slot 1 is correctly installed." }, { "ecode": "0300AB0000020003", "intro": "The temperature sensor on the right hotend heatbreak is abnormal. To prevent nozzle clogs, the cooling fan will continue running at high speed. You can troubleshoot the sensor issue when the print is idle." } ] }, "device_error": { "ver": 202511162200, "en": [ { "ecode": "0582409C", "intro": "The firmware of AMS-HT C does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0500409B", "intro": "The firmware of Laser Module does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05874096", "intro": "The device cannot detect AMS-HT H. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "0584409C", "intro": "The firmware of AMS-HT E does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05004099", "intro": "The firmware of Cutting Module does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0580409C", "intro": "The firmware of AMS-HT A does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0500808D", "intro": "The Cutting Module offset calibration failed, which may result in inaccurate cuts. Please ensure the cutting material is properly positioned and check whether the cutting blade tip is worn." }, { "ecode": "0500409F", "intro": "The device cannot detect the Air Pump. Please reconnect the module cable or restart the printer." }, { "ecode": "0502409D", "intro": "The firmware of AMS C does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0581409C", "intro": "The firmware of AMS-HT B does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05854096", "intro": "The device cannot detect AMS-HT E. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "0C008043", "intro": "AI detected nozzle clumping. Please check the nozzle condition. Refer to assistant for solutions." }, { "ecode": "0500808E", "intro": "BirdsEye Camera initialization failed. The toolhead camera did not detect the Heatbed features. Please clean the Heatbed, remove all objects and pads, and ensure the bed markings are visible. Check Assistant for a detailed solution." }, { "ecode": "0503409D", "intro": "The firmware of AMS D does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0C008042", "intro": "The AI print monitor has detected a spaghetti defect. Please check the print and take the necessary action." }, { "ecode": "05834096", "intro": "The device cannot detect AMS-HT D. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "0500808F", "intro": "Nozzle camera lens is dirty, affecting AI monitoring. Clean the lens with a non-woven cloth and a small amount of alcohol. Beware of hotend heat; wait for it to cool before handling." }, { "ecode": "05814096", "intro": "The device cannot detect AMS-HT B. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "05034098", "intro": "The device cannot detect AMS D. Please reconnect the AMS cable or restart the printer." }, { "ecode": "0587409C", "intro": "The firmware of AMS-HT H does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0583409C", "intro": "The firmware of AMS-HT D does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05014098", "intro": "The device cannot detect AMS B. Please reconnect the AMS cable or restart the printer." }, { "ecode": "05004098", "intro": "The device cannot detect AMS A. Please reconnect the AMS cable or restart the printer." }, { "ecode": "0586409C", "intro": "The firmware of AMS-HT G does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05824096", "intro": "The device cannot detect AMS-HT C. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "0585409C", "intro": "The firmware of AMS-HT F does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0501409D", "intro": "The firmware of AMS B does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "03004050", "intro": "Liveview Camera calibration timeout; please restart the printer." }, { "ecode": "0500409D", "intro": "The firmware of AMS A does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "05804096", "intro": "The device cannot detect AMS-HT A. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "05024098", "intro": "The device cannot detect AMS C. Please reconnect the AMS cable or restart the printer." }, { "ecode": "05004097", "intro": "The device cannot detect the Laser Module. Please reconnect the module cable or restart the printer." }, { "ecode": "05864096", "intro": "The device cannot detect AMS-HT G. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "05844096", "intro": "The device cannot detect AMS-HT F. Please reconnect the AMS-HT cable or restart the printer." }, { "ecode": "0500409A", "intro": "The firmware of Air Pump does not match the printer; the device cannot continue working. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0C008034", "intro": "Liveview Camera initialization failed. This print can still continue, but some AI functions will be disabled. If you encounter this issue again after restarting, please contact customer support." }, { "ecode": "0500409E", "intro": "The device cannot detect the Cutting Module. Please reconnect the module cable or restart the printer." }, { "ecode": "050080A0", "intro": "The visual encoder board was not detected. Please check if the board is properly placed and aligned at all four corners, and ensure the positioning markings are clear and free from wear." }, { "ecode": "0502400B", "intro": "" }, { "ecode": "03004014", "intro": "Homing Z axis failed: temperature control abnormality." }, { "ecode": "0502400E", "intro": "Failed to start a new task: The nozzle cold pull was not completed." }, { "ecode": "0502400A", "intro": "" }, { "ecode": "05024007", "intro": "" }, { "ecode": "0502C010", "intro": "Due to printer power limitations, printing, calibration, controls and other actions cannot be performed during AMS drying. Please stop the drying process before proceeding with any other operation." }, { "ecode": "0502400C", "intro": "" }, { "ecode": "05024009", "intro": "" }, { "ecode": "0502400D", "intro": "Failed to start a new task: filament loading/unloading not completed." }, { "ecode": "05008090", "intro": "Please attach the 80g White Printing Paper to the center area of the platform." }, { "ecode": "0502C00F", "intro": "The device is busy and cannot perform nozzle identification." }, { "ecode": "03008022", "intro": "The heatbed may be obstructed while moving downward. Please clear any objects beneath the heatbed and check for any resistance or jamming during its movement." }, { "ecode": "05024008", "intro": "" }, { "ecode": "18018033", "intro": "Failed to nest hotend into slot 2 on the rack." }, { "ecode": "07058034", "intro": "Failed to fetch induction hotend from slot 6 on the rack." }, { "ecode": "1A008002", "intro": "Induction Hotend Rack homing failed due to an obstruction. Please remove the obstacle before resuming printing." }, { "ecode": "07048034", "intro": "Failed to fetch induction hotend from slot 5 on the rack." }, { "ecode": "18048033", "intro": "Failed to nest hotend into slot 5 on the rack." }, { "ecode": "1A008003", "intro": "The Hotend Rack homing distance is abnormally long. Please check whether the timing belt is loose or broken." }, { "ecode": "07038034", "intro": "Failed to fetch induction hotend from slot 4 on the rack." }, { "ecode": "18008034", "intro": "Failed to fetch induction hotend from slot 1 on the rack." }, { "ecode": "18008035", "intro": "Hotend Rack coarse homing failed. Please check for obstructions or if the build plate is misaligned." }, { "ecode": "18038034", "intro": "Failed to fetch induction hotend from slot 4 on the rack." }, { "ecode": "07048033", "intro": "Failed to nest hotend into slot 5 on the rack." }, { "ecode": "1A008004", "intro": "Before using Laser Mode or calibrating the Hotend Rack position, please remove all hotends from the rack." }, { "ecode": "18028034", "intro": "Failed to fetch induction hotend from slot 3 on the rack." }, { "ecode": "07028034", "intro": "Failed to fetch induction hotend from slot 3 on the rack." }, { "ecode": "07008031", "intro": "Failed to lock the induction hotend." }, { "ecode": "07018034", "intro": "Failed to fetch induction hotend from slot 2 on the rack." }, { "ecode": "18018034", "intro": "Failed to fetch induction hotend from slot 2 on the rack." }, { "ecode": "07008035", "intro": "Hotend Rack coarse homing failed. Please check for obstructions or if the build plate is misaligned." }, { "ecode": "18028033", "intro": "Failed to nest hotend into slot 3 on the rack." }, { "ecode": "18058034", "intro": "Failed to fetch induction hotend from slot 6 on the rack." }, { "ecode": "18008031", "intro": "Failed to lock the induction hotend." }, { "ecode": "18008032", "intro": "Failed to unlock the induction hotend." }, { "ecode": "18008030", "intro": "Hotend pre-swap check failed." }, { "ecode": "03008071", "intro": "The Toolhead Enhanced Cooling Fan module is malfunctioning." }, { "ecode": "07008034", "intro": "Failed to fetch induction hotend from slot 1 on the rack." }, { "ecode": "1A004001", "intro": "Hotend rack coarse homing failed. Printing has been canceled. Please check if any obstruction is blocking the rack movement." }, { "ecode": "07028033", "intro": "Failed to nest hotend into slot 3 on the rack." }, { "ecode": "18058033", "intro": "Failed to nest hotend into slot 6 on the rack." }, { "ecode": "18038033", "intro": "Failed to nest hotend into slot 4 on the rack." }, { "ecode": "18048034", "intro": "Failed to fetch induction hotend from slot 5 on the rack." }, { "ecode": "07008033", "intro": "Failed to nest hotend into slot 1 on the rack." }, { "ecode": "07018033", "intro": "Failed to nest hotend into slot 2 on the rack." }, { "ecode": "18008033", "intro": "Failed to nest hotend into slot 1 on the rack." }, { "ecode": "07008032", "intro": "Failed to unlock the induction hotend." }, { "ecode": "07038033", "intro": "Failed to nest hotend into slot 4 on the rack." }, { "ecode": "07058033", "intro": "Failed to nest hotend into slot 6 on the rack." }, { "ecode": "07008030", "intro": "Hotend pre-swap check failed." }, { "ecode": "05004010", "intro": "AMS is drying and cannot be upgraded at the moment. Please try again later." }, { "ecode": "05004011", "intro": "The printer is loading or unloading filament and cannot be upgraded at the moment. Please try again later." }, { "ecode": "05004012", "intro": "The device is printing and cannot be upgraded at the moment. Please try again later." }, { "ecode": "0500400F", "intro": "AMS is initializing and cannot be upgraded at the moment. Please try again later." }, { "ecode": "05004013", "intro": "AMS is in operation and cannot be upgraded at the moment. Please try again when it is idle." }, { "ecode": "0300C012", "intro": "Please heat the nozzle to above 170°C." }, { "ecode": "050040A1", "intro": "The device cannot detect Fire Extinguisher. Please reconnect the module cable or restart the printer." }, { "ecode": "050040A0", "intro": "The device cannot detect Laser Fourth Axis. Please reconnect the module cable or restart the printer." }, { "ecode": "05004030", "intro": "The device is currently upgrading. Please try again when it is idle." }, { "ecode": "07FF8030", "intro": "The filament specified in the slicer has been used up. Printing is paused. Please go to the machine to replace the material and resume printing." }, { "ecode": "07FE8030", "intro": "The filament specified in the slicer has been used up. Printing is paused. Please go to the machine to replace the material and resume printing." }, { "ecode": "0300C056", "intro": "A minor fire was detected inside the chamber, and the Auto Fire Extinguishing process has been aborted." }, { "ecode": "0502C011", "intro": "Currently in 2D production mode. Please continue the operation on the printer" }, { "ecode": "03008081", "intro": "Fire extinguisher cylinder not installed. Please confirm on the extinguisher page." }, { "ecode": "0300807E", "intro": "Fire Extinguisher not detected, the automatic extinguishing function will be unavailable." }, { "ecode": "0300807F", "intro": "Fire Extinguisher is malfunctioning." }, { "ecode": "03008082", "intro": "The Fire Extinguisher Gas Cylinder is empty." }, { "ecode": "03004021", "intro": "Nozzle offset calibration sensor signal abnormality detected. Please check the sensor and retry." }, { "ecode": "03008080", "intro": "Fire extinguisher motor reset failed." }, { "ecode": "0300807D", "intro": "Fire Extinguisher not detected, the automatic extinguishing function will be unavailable." }, { "ecode": "0502C012", "intro": "The task cannot be paused." }, { "ecode": "05008091", "intro": "The Cutting Module offset calibration failed, which may result in inaccurate cuts. Please ensure the 80g white printer paper(letter paper thickness) is properly positioned and check whether the cutting blade tip is worn." }, { "ecode": "0300404B", "intro": "Task aborted because the front door or top cover is open." }, { "ecode": "03008028", "intro": "Nozzle offset calibration sensor error. If using a single hotend or the calibration function is disabled, you may ignore this and continue printing; otherwise, it is recommended to check the sensor before proceeding." }, { "ecode": "05008041", "intro": "The filament in hotend is too cold. Extrusion may damage the extruder. Still feeding in/out the filament?" }, { "ecode": "0300C070", "intro": "The fire extinguisher has been detected and is ready for use after the laser module is connected." }, { "ecode": "05008093", "intro": "The nozzle silicone sleeve is not installed; there is a risk of temperature control failure. Please install it correctly and try again." }, { "ecode": "05008092", "intro": "Toolhead Camera initialization failed. This print can still continue, but some AI functions will be disabled. If you encounter this issue again after restarting, please contact customer support." }, { "ecode": "03008023", "intro": "XY motor homing failed during hotend holder homing. Please check for obstructions and retry." }, { "ecode": "03008027", "intro": "Hotend dropped from the holder during printing. Please return it to the original position before continuing." }, { "ecode": "03008024", "intro": "Hotend holder homing blocked. Please check for obstructions and retry." }, { "ecode": "03008026", "intro": "Laser/Calibration mode: Please remove all hotends from the holder before retrying." }, { "ecode": "03008025", "intro": "Hotend holder homing distance too long. Please inspect the timing belt and motor gear for looseness or damage." }, { "ecode": "05004032", "intro": "Hotend Change System is busy; please perform the upgrade when it is idle." }, { "ecode": "07008018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "0500807E", "intro": "Please place a StrongGrip cutting mat on the cutting protection base." }, { "ecode": "07028018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "05004046", "intro": "The print has stopped because the 3MF file is invalid. Please verify that the correct printer model was selected during slicing, or update Studio and re-slice the file." }, { "ecode": "07058018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "07038018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "07FE8018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "07048018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "0502C014", "intro": "The AMS Remaining Filament Estimation is enabled by default and cannot be disabled." }, { "ecode": "07068018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "05004047", "intro": "The print has stopped because the available hotend quantity or model does not match the sliced file. Please verify the hotend model and quantity before restarting the print job." }, { "ecode": "07018018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "07078018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "07FF8018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "05024015", "intro": "Hotend authentication failed. Please switch the hotend or restart the printer." }, { "ecode": "05024017", "intro": "The task failed due to a timeout on the induction hotend switch. Please go to the \"Hotend & Rack\" page and click \"Read All\" to switch manually." }, { "ecode": "18008018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18FE8018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18028018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18FF8018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18078018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18058018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18048018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "05024016", "intro": "No available hotend was detected in the induction hotend holder or the hotend rack. Please install a hotend and try again." }, { "ecode": "1A004007", "intro": "Induction hotend rack calibration failed, please check the Assistant." }, { "ecode": "18038018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18068018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "18018018", "intro": "Failed to get filament-hotend mapping table from the slicing file, please retry." }, { "ecode": "03008053", "intro": "Laser module detected. Please install the right nozzle correctly to ensure proper Laser Module Mounting Calibration." }, { "ecode": "03008084", "intro": "The right hotend heatbreak temperature is too high, which may cause clogging. Please open the printer’s top cover and front door to reduce the chamber temperature, or lower the ambient temperature." }, { "ecode": "1A004008", "intro": "The hotend rack is fully occupied, and hotend switching cannot be performed. Please remove one hotend before proceeding." }, { "ecode": "05024019", "intro": "The device is busy and cannot perform hotend rack tasks at this moment. Please try again later." }, { "ecode": "0300401F", "intro": "The right hotend is not installed, and the toolhead cannot perform homing. Please install the hotend and then continue." }, { "ecode": "05024018", "intro": "The hotend rack has not been calibrated, and hotend switching cannot be performed. Please complete the rack calibration on the device." }, { "ecode": "05024020", "intro": "The hotend rack is fully occupied. Please remove one hotend before proceeding." }, { "ecode": "05024021", "intro": "Failed to read induction hotend information. Please replace the hotend or restart the printer." }, { "ecode": "03004016", "intro": "Nozzle cleaning failed. Please click the Assistant for troubleshooting." }, { "ecode": "0300802B", "intro": "Hotend rack motor error. Please check and remove any obstructions affecting rack movement before continuing." }, { "ecode": "03008029", "intro": "MC–hotend rack communication error. Please check if the rack mainboard cable is loose." }, { "ecode": "05028022", "intro": "Induction hotend verification failed. Please replace the hotend and try again." }, { "ecode": "0300802A", "intro": "Hotend rack motor position sensor error. If the issue persists after retrying, restart the printer." }, { "ecode": "07008036", "intro": "Hotend rack coarse homing failed. Please check for obstructions or if the build plate is misaligned." }, { "ecode": "18008036", "intro": "Hotend rack coarse homing failed. Please check for obstructions or if the build plate is misaligned." }, { "ecode": "1A004009", "intro": "The hotend rack has not been set up. Please complete the setup before performing a hotend replacement." }, { "ecode": "03008056", "intro": "Laser module detected. Please remove the hotend from the hotend rack to prevent laser processing debris from affecting printing performance." }, { "ecode": "05024023", "intro": "Induction hotend recognition error detected. Please go to the \"Hotends & Rack\" page and click \"Read All\" to re-detect. If the issue persists, try updating the firmware on the \"Firmware\" page." }, { "ecode": "07038030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07048030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18018030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07018030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18068030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07078030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07028030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18058030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18048030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07058030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18028030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18078030", "intro": "Hotend pre-swap check failed." }, { "ecode": "18038030", "intro": "Hotend pre-swap check failed." }, { "ecode": "07068030", "intro": "Hotend pre-swap check failed." }, { "ecode": "0502C024", "intro": "The flow dynamic calibration records have exceeded the storage limit. Please delete some historical records in the slicer software before adding new calibration data." }, { "ecode": "0502C025", "intro": "A hotend information update was detected during nozzle offset calibration. Please go to the \"Hotends & Rack\" page and click “Read All” to reidentify. If the issue persists, try updating from the “Firmware” page." }, { "ecode": "0500808C", "intro": "Detected build plate offset or debris. Please align the build plate with the heatbed and remove all debris from the plate surface before continuing." }, { "ecode": "07028037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 3 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "07038037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 4 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "07018037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 2 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "07008037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 1 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "07048037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 5 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "07058037", "intro": "Hotend type mismatch detected during printing. Please replace the hotend in slot 6 on the rack with the type specified in the slicer before continuing the print." }, { "ecode": "05008078", "intro": "Current material does not match the sliced file settings. Please load the correct material and ensure the QR code on the material is not damaged or dirty." }, { "ecode": "05024005", "intro": "The AMS has not been calibrated yet, so printing cannot be initiated." }, { "ecode": "07038012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18FFC006", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "05008062", "intro": "The print plate marker was not detected. Please confirm the print plate is correctly positioned on the heatbed with all four corners aligned, and the marker is visible. If strong light is shining on the print sheet, consider closing the front door and blocking external light sources." }, { "ecode": "07058011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "03008042", "intro": "Task paused because the door or top cover is open." }, { "ecode": "0C008015", "intro": "Objects detected on the platform; please clean them up in a timely manner." }, { "ecode": "07FFC012", "intro": "Press the black PTFE tube coupler and unplug the PTFE tube. After completing the operation, click \"Continue.\"" }, { "ecode": "03004000", "intro": "Z axis homing failed; the task has been stopped." }, { "ecode": "0300800B", "intro": "The cutter is stuck. Please make sure the cutter handle is out and check the filament sensor cable connection." }, { "ecode": "1802C06B", "intro": "AMS-HT C is changing filament. Unable to start drying. Please try again later." }, { "ecode": "18078005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "07048003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "0500400E", "intro": "Printing was cancelled." }, { "ecode": "07FEC011", "intro": "Please manually and slowly pull out the filament from the extruder. Then click “Continue”." }, { "ecode": "05008060", "intro": "The current module on toolhead does not meet requirements. Please replace the module as per the on-screen instructions." }, { "ecode": "0500403F", "intro": "Failed to download print job; please check your network connection." }, { "ecode": "18038013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07028006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "18018013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "05004006", "intro": "There is not enough free storage space for the print job. Restoring to factory settings can free up available space." }, { "ecode": "0501401E", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "18FFC009", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "1800800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT A to the extruder is properly connected." }, { "ecode": "05004003", "intro": "Printing stopped because the printer was unable to parse the file. Please resend your print job." }, { "ecode": "05014034", "intro": "The slicing progress has not been updated for a long time, and the printing task has exited. Please confirm the parameters and reinitiate printing." }, { "ecode": "18078006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "18038012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0300400C", "intro": "The task was canceled." }, { "ecode": "0C004020", "intro": "The setup of BirdsEye Camera failed. Please clear all objects and remove the mat. Make sure the marker is not obstructed. Meanwhile, clean both the BirdsEye Camera and Toolhead Camera, and remove any foreign objects blocking their view." }, { "ecode": "18028007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "03008021", "intro": "The nozzle may not be installed or not properly installed. Please ensure the nozzle is correctly installed before proceeding." }, { "ecode": "03008047", "intro": "Quick-release lever detection time out: please restart the printer." }, { "ecode": "0500C032", "intro": "Laser/Cutting module connected to the toolhead. The drying process has been automatically stopped." }, { "ecode": "03008018", "intro": "Chamber temperature malfunction." }, { "ecode": "07058016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "05004002", "intro": "Unsupported print file path or name. Please resend the print job." }, { "ecode": "03008044", "intro": "Fire was detected inside the chamber." }, { "ecode": "07078016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07028013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07038006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "05014021", "intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "07FEC006", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "1806C06E", "intro": "AMS-HT G motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "1800C069", "intro": "An error occurred during AMS-HT A drying. Please go to Assistant for more details." }, { "ecode": "1804C06A", "intro": "AMS-HT E is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "18FE8003", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)" }, { "ecode": "1807C06C", "intro": "AMS-HT H is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "03008062", "intro": "The chamber temperature is too high. It may be due to high environmental temperature." }, { "ecode": "18018021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "03004002", "intro": "Auto Bed Leveling failed; the task has been stopped." }, { "ecode": "18FFC00A", "intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, select \"Continue\"; if not, please push the filament forward slightly and then select \"Retry\"." }, { "ecode": "1803C069", "intro": "An error occurred during AMS-HT D drying. Please go to Assistant for more details." }, { "ecode": "0500806B", "intro": "Quick-release Lever is not locked. Please press down the external toolhead module to ensure it is properly seated, then push down the level to lock it in place." }, { "ecode": "0500401D", "intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "0703C06D", "intro": "AMS D is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "05004040", "intro": "The printer has reached its power limit. Please connect a dedicated power adapter to this AMS to enable drying." }, { "ecode": "0C008017", "intro": "Foreign objects detected on the platform; please clean them up on time." }, { "ecode": "18008021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "07FFC010", "intro": "Insert the filament (over 30cm long) until it stops. You might see slight smoke during flushing. After insertion, close the front door and top cover." }, { "ecode": "18018023", "intro": "AMS-HT B cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "18FF8002", "intro": "The cutter of the right extruder is stuck. Please pull out the cutter handle." }, { "ecode": "0300400A", "intro": "Mechanical resonance frequency identification failed." }, { "ecode": "07FE8002", "intro": "The cutter of the left extruder is stuck. Please pull out the cutter handle." }, { "ecode": "05004041", "intro": "The AMS drying cannot be started during printing." }, { "ecode": "05008071", "intro": "No cutting platform was detected. Please confirm that it has been correctly placed." }, { "ecode": "18008012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18048016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18038010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "0501401C", "intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07068004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "07008010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "07FF8011", "intro": "The external filament connected to the right extruder has run out; please load a new filament." }, { "ecode": "18078016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18028012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "05004027", "intro": "Cloud access failed; this may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "18018004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "07018017", "intro": "AMS B is drying. Please stop drying process before loading/unloading material." }, { "ecode": "07038010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05004075", "intro": "No Laser Platform was detected, which may affect thickness measurement accuracy. Please place the laser platform correctly and ensure the rear markers are not blocked, then restart the thickness measurement in the software before initiating the task." }, { "ecode": "1802C06C", "intro": "AMS-HT C is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "05008066", "intro": "The task requires a Cutting Platform, but the current one is a Laser Platform. Please replace it with a Cutting Platform (Cutting Protection Base + LightGrip cutting mat)." }, { "ecode": "05004025", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "0706800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS G to the extruder is properly connected." }, { "ecode": "18068021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "05008036", "intro": "Your sliced file is not consistent with the current printer model. Continue?" }, { "ecode": "0C008033", "intro": "Quick-release Lever is not locked. Please push it down to secure." }, { "ecode": "0C00800B", "intro": "The heatbed marker was not detected. Please clear all objects and remove the mat. Make sure the marker is not obstructed." }, { "ecode": "18044025", "intro": "Failed to read the filament information." }, { "ecode": "1803C06C", "intro": "AMS-HT D is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "1806C06D", "intro": "AMS-HT G is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "05004023", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "05008030", "intro": "" }, { "ecode": "07FF8004", "intro": "Failed to pull back the filament from the right extruder. Please check whether the filament is stuck inside the extruder." }, { "ecode": "0501401D", "intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "07068021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "0501401B", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "18008017", "intro": "AMS-HT A is drying. Please stop drying process before loading/unloading material." }, { "ecode": "07058012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18058004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0701C069", "intro": "An error occurred during AMS B drying. Please go to Assistant for more details." }, { "ecode": "05004026", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "1801C06C", "intro": "AMS-HT B is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "18FF8011", "intro": "The external filament connected to the right extruder has run out; please load a new filament." }, { "ecode": "07FF8005", "intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck." }, { "ecode": "05008072", "intro": "Live View camera is blocked" }, { "ecode": "0702C06E", "intro": "AMS C motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "0500400A", "intro": "The file name is not supported. Please rename and restart the print job." }, { "ecode": "07048004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0700C06D", "intro": "AMS A is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "0C00402C", "intro": "Device data link error. Please reboot the printer." }, { "ecode": "18008004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "18FE8013", "intro": "Timeout purging old filament of the left extruder: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07048023", "intro": "AMS E cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "05004035", "intro": "The BirdsEye Camera is malfunctioning. Please try restarting the device. If the issue persists after multiple restarts, check the camera connection status or contact customer support." }, { "ecode": "18FF8004", "intro": "Failed to pull back the filament from the right extruder. Please check whether the filament is stuck inside the extruder." }, { "ecode": "05008079", "intro": "Please place the Laser Test Material (350g paperboard) and position support strips underneath to prevent material warping." }, { "ecode": "1802C06A", "intro": "AMS-HT C is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "05008087", "intro": "BirdsEye camera is obstructed" }, { "ecode": "07078007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "1802800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT C to the extruder is properly connected." }, { "ecode": "07FE8007", "intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, select \"Continue\"; if it is not, please push the filament forward slightly, and then select \"Retry\"." }, { "ecode": "05004007", "intro": "The device requires a repair upgrade, and printing is currently unavailable." }, { "ecode": "07FEC012", "intro": "Press the black PTFE tube coupler and unplug the PTFE tube. After completing the operation, click \"Continue.\"" }, { "ecode": "05008089", "intro": "Task paused due to Presence Check failed. Please check the printer to continue." }, { "ecode": "07018010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "1804C06E", "intro": "AMS-HT E motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "03008055", "intro": "The module mounted on the toolhead does not match the task. Please install the correct module." }, { "ecode": "07058010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05008085", "intro": "Toolhead camera is obstructed" }, { "ecode": "07FF8025", "intro": "Cold pull timed out. Please promptly operate or check whether the filament is broken inside the extruder, and click the Assistant for details." }, { "ecode": "07028016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18078011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "07FF8013", "intro": "Timeout purging old filament of the right extruder: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07068011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "1801800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT B to the extruder is properly connected." }, { "ecode": "03008048", "intro": "Laser Module unlock has timed out, and the task cannot proceed. Please restart the printer and try again." }, { "ecode": "0500401C", "intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "05004031", "intro": "The accessory firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "18008003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05008063", "intro": "The platform is not detected during calibration; please make sure the Laser Platform is properly placed." }, { "ecode": "03008010", "intro": "The hotend cooling fan speed is abnormal." }, { "ecode": "18058003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "07FE8021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "18048005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "0702C06C", "intro": "AMS C is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "0C008016", "intro": "The foreign object detection function is not working. You can continue the task or check assistant for solutions." }, { "ecode": "18FF8006", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "0300801C", "intro": "The extrusion resistance is abnormal. The extruder may be clogged, please refer to the assistant, after trouble shooting, you can select \"Resume\" to resume the print job." }, { "ecode": "07068013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "10014001", "intro": "Timelapse is not supported as Spiral Vase mode is enabled in slicing presets." }, { "ecode": "0702C06B", "intro": "AMS C is changing filament. Unable to start drying. Please try again later." }, { "ecode": "07048006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "18058016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18FEC009", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "07038023", "intro": "AMS D cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "18FF8024", "intro": "Extruder position calibration failed; please refer to the assistant." }, { "ecode": "0500C07F", "intro": "Device is busy and cannot perform this operation. To proceed, please pause or stop the current task." }, { "ecode": "07068003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05008067", "intro": "Please place a LightGrip cutting mat on the cutting protection base." }, { "ecode": "18064025", "intro": "Failed to read the filament information." }, { "ecode": "18FEC006", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "07048010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05FF8081", "intro": "The right hotend is not installed." }, { "ecode": "0500807B", "intro": "Please place the cutting platform (cutting protection base + LightGrip cutting mat)." }, { "ecode": "18078012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "05FF806A", "intro": "Unable to recognize the right hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please set hotend type on printer screen before next print." }, { "ecode": "18048023", "intro": "AMS-HT E cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "03008003", "intro": "Spaghetti defects were detected by the AI Print Monitoring. Please check the quality of the printed model before continuing your print." }, { "ecode": "18048010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "1803C06A", "intro": "AMS-HT D is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "0500403B", "intro": "Laser/cutting tasks cannot be initiated on the machine at the moment. Please use the computer software to start the task." }, { "ecode": "18018016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18068012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0500402A", "intro": "Failed to connect to the router, which may be caused by wireless interference or being too far away from the router. Please try again or move the printer closer to the router and try again." }, { "ecode": "07018012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "07018005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "07018006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "07038013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "18038007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18048007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "07FE8013", "intro": "Timeout purging old filament of the left extruder: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "18FF8007", "intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, select \"Continue\"; if it is not, please push the filament forward slightly, and then select \"Retry\"." }, { "ecode": "18008010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "07078011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "05014039", "intro": "Device login has expired; please try to bind again." }, { "ecode": "0500806F", "intro": "The grip cutting mat type does not match; please place a StrongGrip cutting mat." }, { "ecode": "0500401E", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "18038003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "0C004026", "intro": "The Live View Camera initialization failed; please reboot the printer." }, { "ecode": "07FE8025", "intro": "Cold pull timed out. Please promptly operate or check whether the filament is broken inside the extruder, and click the Assistant for details." }, { "ecode": "18048021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "07FFC009", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "0703C069", "intro": "An error occurred during AMS D drying. Please go to Assistant for more details." }, { "ecode": "18FE8004", "intro": "Failed to pull back the filament from the left extruder. Please check whether the filament is stuck inside the extruder." }, { "ecode": "07008023", "intro": "AMS A cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "0701800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS B to the extruder is properly connected." }, { "ecode": "05008051", "intro": "Detected build plate is not the same as the Gcode file. Please adjust slicer settings or use the correct plate." }, { "ecode": "05004065", "intro": "The task requires a Laser Platform, but the current one is a Cutting Platform. Please replace it, measure the material thickness in the software, and then restart the task." }, { "ecode": "0C00403D", "intro": "The vision encoder plate was not detected. Please confirm it is correctly positioned on the heatbed." }, { "ecode": "03004011", "intro": "Flow Dynamics Calibration failed; please reinitiate printing or calibration." }, { "ecode": "05008056", "intro": "Cutting module is installed, but the laser platform is detected. Please place the cutting platform for calibration." }, { "ecode": "0701C06C", "intro": "AMS B is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "0702C069", "intro": "An error occurred during AMS C drying. Please go to Assistant for more details." }, { "ecode": "03008043", "intro": "The laser module is abnormal." }, { "ecode": "0500C036", "intro": "This is a printing task. Please detach the Laser/Cutting Module from the Toolhead." }, { "ecode": "07058023", "intro": "AMS F cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "18078007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "07FF8006", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "18058011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "05014032", "intro": "QR code binding is in progress, so device discovery binding cannot be performed. You can scan the QR code on the screen for binding or exit the QR code display page on screen and try device discovery binding." }, { "ecode": "18008013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07008017", "intro": "AMS A is drying. Please stop drying process before loading/unloading material." }, { "ecode": "07FF8010", "intro": "Check if the right external filament spool or filament is stuck." }, { "ecode": "0500403E", "intro": "The current tool head does not support initialization." }, { "ecode": "0300804E", "intro": "This is a printing task. Please detach the Laser/Cutting Module from the Toolhead." }, { "ecode": "18038004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0500402B", "intro": "Router connection failed due to incorrect password. Please check the password and try again." }, { "ecode": "18028023", "intro": "AMS-HT C cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "07028017", "intro": "AMS C is drying. Please stop drying process before loading/unloading material." }, { "ecode": "0300404D", "intro": "The current temperature of the hotend, heatbed, or chamber is too high. Please wait for it to cool down to room temperature before restarting the task." }, { "ecode": "05014023", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07018003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "07038004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "1803C06B", "intro": "AMS-HT D is changing filament. Unable to start drying. Please try again later." }, { "ecode": "05004004", "intro": "Device is busy and cannot start new task. Please wait for current task to complete before sending new task." }, { "ecode": "03008017", "intro": "Foreign objects detected on heatbed. Please check and clean the heatbed. Then, select \"Resume\" to resume the print job." }, { "ecode": "18048013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "05014038", "intro": "The regional settings do not match the printer; please check the printer's regional settings." }, { "ecode": "07024025", "intro": "Failed to read the filament information." }, { "ecode": "05004034", "intro": "The Laser Module firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "07008003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05004037", "intro": "Your sliced file is not compatible with current printer model. This file can't be printed on this printer." }, { "ecode": "07058003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "0C004025", "intro": "The Birdseye Camera is dirty. Please clean it and restart the process." }, { "ecode": "07048013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "18038011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "05014027", "intro": "Cloud access failed; this may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "0500807A", "intro": "The foreign object detection function is not working. You can continue the task or check the assistant for troubleshooting." }, { "ecode": "07004025", "intro": "Failed to read the filament information." }, { "ecode": "07038011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "05024003", "intro": "The printer is currently printing and the motion accuracy enhancement feature cannot be turned on or off." }, { "ecode": "18008023", "intro": "AMS-HT A cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "05004043", "intro": "Due to power limitations, only one AMS is allowed to use the device's power for drying." }, { "ecode": "07028011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "05004070", "intro": "The laser or cutter module is connected, so the device cannot initiate a 3D printing task." }, { "ecode": "1800C06A", "intro": "AMS-HT A is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "05014019", "intro": "The printer has already been bound. Please unbind it and try again." }, { "ecode": "05008058", "intro": "Please place the light grip cutting mat correctly and ensure the marker is exposed." }, { "ecode": "0300804A", "intro": "Emergency stop button improperly installed. Please reinstall according to the Wiki before proceeding." }, { "ecode": "1807C06B", "intro": "AMS-HT H is changing filament. Unable to start drying. Please try again later." }, { "ecode": "03008063", "intro": "The chamber temperature is too high. Please open the top cover and front door to cool down." }, { "ecode": "0300800D", "intro": "Detected that the extruder is not extruding normally. If the defects are acceptable, select \"Resume\" to resume the print job." }, { "ecode": "07FF8012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18068006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "0500805C", "intro": "The grip cutting mat type does not match; please place a LightGrip cutting mat." }, { "ecode": "0704800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS E to the extruder is properly connected." }, { "ecode": "1806C06A", "intro": "AMS-HT G is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "03004005", "intro": "The hotend cooling fan speed is abnormal." }, { "ecode": "18018011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "03008008", "intro": "Nozzle temperature malfunction" }, { "ecode": "0701C06B", "intro": "AMS B is changing filament. Unable to start drying. Please try again later." }, { "ecode": "07FE8011", "intro": "The external filament connected to the left extruder has run out; please load a new filament." }, { "ecode": "0700C06B", "intro": "AMS A is changing filament. Unable to start drying. Please try again later." }, { "ecode": "0C00403E", "intro": "The high-precision nozzle offset calibration has failed, possibly due to a damaged pattern or the similarity of the colors of the two selected filaments. Please clear the printed pattern and replace the filaments with higher color contrast before re-calibrating." }, { "ecode": "07008011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "0703800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS D to the extruder is properly connected." }, { "ecode": "10018003", "intro": "The time-lapse mode is set to Traditional in the slicing file. This may cause surface defects. Would you like to enable it?" }, { "ecode": "0500807C", "intro": "Please place the cutting platform (cutting protection base + StrongGrip cutting mat)." }, { "ecode": "18078013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07008013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07008007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18FE8012", "intro": "Failed to get mapping table; please select \"Resume\" to retry." }, { "ecode": "03008019", "intro": "No build plate is placed." }, { "ecode": "05004033", "intro": "The AMS firmware does not match the printer. Please upgrade it on the \"Firmware\" page." }, { "ecode": "0500402C", "intro": "Failed to obtain IP address, which may be caused by wireless interference resulting in data transmission failure or the DHCP address pool of the router being full. Please move the printer closer to the router and try again. If the issue persists, please check router settings to see whether the IP addresses have been exhausted." }, { "ecode": "1801C06D", "intro": "AMS-HT B is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "18028003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "07FE8001", "intro": "Failed to cut the filament of the left extruder. Please check the cutter." }, { "ecode": "18058013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "03008013", "intro": "Printing paused due to the pause command added to the printing file." }, { "ecode": "18008011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "07034025", "intro": "Failed to read the filament information." }, { "ecode": "03004066", "intro": "Calibration of motion precision failed." }, { "ecode": "18FE8011", "intro": "The external filament connected to the left extruder has run out; please load a new filament." }, { "ecode": "18008016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07068005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "03004013", "intro": "Printing cannot be initiated while AMS is drying." }, { "ecode": "0500808C", "intro": "Detected build plate offset. Please align the build plate with the heatbed, and then continue." }, { "ecode": "05004021", "intro": "Cloud access failed, which may be caused by network instability due to interference. You can try moving the printer closer to the router before you try again." }, { "ecode": "07028010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05008073", "intro": "Heatbed limit block is obstructed or contaminated. Please clean and ensure the limit block is visible, otherwise platform position offset detection may be inaccurate." }, { "ecode": "05014017", "intro": "Binding failed. Please retry or restart the printer and retry." }, { "ecode": "03008046", "intro": "Foreign object detect timeout: please restart the printer." }, { "ecode": "0500405D", "intro": "Laser module Serial Number error: unable to calibrate or make project." }, { "ecode": "05004050", "intro": "Error detected on the print board." }, { "ecode": "07078006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "03004052", "intro": "Blade Z-axis homing failed" }, { "ecode": "07008004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "18054025", "intro": "Failed to read the filament information." }, { "ecode": "18018006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "1806800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT G to the extruder is properly connected." }, { "ecode": "05004009", "intro": "Print jobs are not allowed to be sent while updating logs." }, { "ecode": "03008045", "intro": "Material detection timeout: please restart the printer." }, { "ecode": "05014026", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "18038017", "intro": "AMS-HT D is drying. Please stop drying process before loading/unloading material." }, { "ecode": "0300400F", "intro": "The power supply voltage does not match the printer." }, { "ecode": "05004005", "intro": "Print jobs are not allowed to be sent while updating firmware." }, { "ecode": "18028013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "05008086", "intro": "Toolhead Camera is dirty, which affects the AI function; please clean the lens surface." }, { "ecode": "0500400B", "intro": "There was a problem downloading a file. Please check your network connection and resend the print job." }, { "ecode": "07048016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07068023", "intro": "AMS G cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "07018016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "0C004024", "intro": "The Birdseye Camera is installed offset. Please refer to the assistant to reinstall it." }, { "ecode": "18018012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "07038016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "18068005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "0701C06E", "intro": "AMS B motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "05004001", "intro": "Failed to connect to Bambu Cloud. Please check your network connection." }, { "ecode": "0702C06D", "intro": "AMS C is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "18018017", "intro": "AMS-HT B is drying. Please stop drying process before loading/unloading material." }, { "ecode": "18058021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "07018011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "07078013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "07FEC009", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "05004022", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "1801C069", "intro": "An error occurred during AMS-HT B drying. Please go to Assistant for more details." }, { "ecode": "03008064", "intro": "The chamber temperature is too high. Please open the top cover and front door to cool down. (Open door detection for this print job will be set to \"Notification\" level)" }, { "ecode": "07078003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "18028017", "intro": "AMS-HT C is drying. Please stop drying process before loading/unloading material." }, { "ecode": "0C004022", "intro": "The setup of BirdsEye Camera failed. Please check if the laser module is working properly." }, { "ecode": "18FF8005", "intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck." }, { "ecode": "1805800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT F to the extruder is properly connected." }, { "ecode": "07074025", "intro": "Failed to read the filament information." }, { "ecode": "18008007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18048012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "05014035", "intro": "The device is in the process of binding and cannot respond to new binding requests." }, { "ecode": "07038007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "07028012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18048011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "1800C06C", "intro": "AMS-HT A is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "05FE8080", "intro": "The left hotend is not installed." }, { "ecode": "05FF8069", "intro": "Unable to recognize the right hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please manually set the hotend type." }, { "ecode": "05FF8053", "intro": "The right nozzle is not matched with slicing file. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high." }, { "ecode": "07FEC008", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "10014002", "intro": "Timelapse is not supported as the Print sequence is set to \"By object\"." }, { "ecode": "18068023", "intro": "AMS-HT G cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "18048004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0700C069", "intro": "An error occurred during AMS A drying. Please go to Assistant for more details." }, { "ecode": "05004052", "intro": "Error detected on the hot end." }, { "ecode": "0300400D", "intro": "Resume failed after power loss." }, { "ecode": "03008009", "intro": "Heatbed temperature malfunction" }, { "ecode": "07048021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "18FFC008", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "0500C010", "intro": "USB flash drive read-write exception; please reinsert or replace it." }, { "ecode": "07068006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "05004019", "intro": "The printer has already been bound. Please unbind it and try again." }, { "ecode": "07FF8003", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)" }, { "ecode": "07028004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0300804B", "intro": "Task paused. The Laser Safety Window is open." }, { "ecode": "18028021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "05004029", "intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07058005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "18FE8006", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "03008041", "intro": "Platform detection timeout: please restart the printer." }, { "ecode": "07FE8020", "intro": "Extruder change failed; please refer to the assistant." }, { "ecode": "18FEC003", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "18068007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18058005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "05008088", "intro": "The Birdseye Camera is dirty" }, { "ecode": "0C00C004", "intro": "Possible spaghetti failure was detected." }, { "ecode": "05024001", "intro": "Current filament will be used in this print job. Settings cannot be changed." }, { "ecode": "18038023", "intro": "AMS-HT D cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "18068016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07FE8024", "intro": "Extruder position calibration failed; please refer to the assistant." }, { "ecode": "18FF8012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0500403D", "intro": "The toolhead module is not set up. Please set it up before initiating the task." }, { "ecode": "18068004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "05004038", "intro": "The nozzle diameter in sliced file is not consistent with the current nozzle setting. This file can't be printed." }, { "ecode": "1807800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT H to the extruder is properly connected." }, { "ecode": "05014029", "intro": "Cloud access is rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07058006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "0703C06C", "intro": "AMS D is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "03008014", "intro": "The nozzle is covered with filament, or the build plate is installed incorrectly. Please cancel this print and clean the nozzle or adjust the build plate according to the actual status. You can also select \"Resume\" to resume the print job." }, { "ecode": "05004028", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "0300801D", "intro": "The extruder servo motor position sensor is malfunctioning. Please power off the printer first and check if the connection cable is loose." }, { "ecode": "0300804F", "intro": "The loading/unloading process is currently ongoing. Please stop the process or remove the laser/cutting module." }, { "ecode": "07058021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "05008068", "intro": "Please place the strong grip cutting mat correctly and ensure the marker is exposed." }, { "ecode": "05008082", "intro": "Please remove the protective film on the Opaque Glossy Acrylic before processing" }, { "ecode": "07048011", "intro": "AMS filament ran out. Please insert a new filament into the same AMS slot." }, { "ecode": "05014028", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "05004076", "intro": "Please place the Laser Platform correctly and ensure the rear markers are not blocked, then restart the thickness measurement in the software before initiating the task." }, { "ecode": "18FF8003", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)" }, { "ecode": "03008054", "intro": "Please place the paper required for Print Then Cut." }, { "ecode": "07078010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "1806C06C", "intro": "AMS-HT G is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "07044025", "intro": "Failed to read the filament information." }, { "ecode": "07028023", "intro": "AMS C cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "0C008040", "intro": "AI detected air-printing defect. Please check the hotend extrusion status. Refer to assistant for solutions." }, { "ecode": "0705800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS F to the extruder is properly connected." }, { "ecode": "0C004021", "intro": "The setup of BirdsEye Camera failed; please reboot the printer." }, { "ecode": "18058010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05004024", "intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before you try again." }, { "ecode": "18FEC00A", "intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, select \"Continue\"; if not, please push the filament forward slightly and then select \"Retry\"." }, { "ecode": "05004054", "intro": "Error detected on the mat." }, { "ecode": "0500400D", "intro": "Please run a self-test and restart the print job." }, { "ecode": "07058013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "0500806C", "intro": "Please place the cutting platform correctly and ensure the marker is exposed." }, { "ecode": "0701C06A", "intro": "AMS B is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "05024004", "intro": "Some features are not supported by the current device. Please check the Studio feature settings or update the firmware to the latest version." }, { "ecode": "0C00803F", "intro": "AI detected nozzle clumping. Please check the nozzle condition. Refer to assistant for solutions." }, { "ecode": "0300800F", "intro": "The door seems to be open, so printing was paused." }, { "ecode": "05008077", "intro": "The visual marker was not detected. Please ensure the paper is properly placed." }, { "ecode": "0500807D", "intro": "This task requires a Cutting Platform, but the current one is a Laser Platform. Please replace it with a Cutting Platform (Cutting Protection Base + StrongGrip Cutting Mat)." }, { "ecode": "05FE8081", "intro": "The left hotend is not installed." }, { "ecode": "03008001", "intro": "Printing was paused by the user. You can select \"Resume\" to continue printing." }, { "ecode": "0500806E", "intro": "Foreign objects detected on heatbed; please check and clean up the heatbed." }, { "ecode": "0C004027", "intro": "The Live View Camera calibration failed. Please refer to the assistant for details and recalibrate the camera after processing." }, { "ecode": "0C00C006", "intro": "Purged filament may have piled up in the waste chute." }, { "ecode": "0C008002", "intro": "" }, { "ecode": "1802C069", "intro": "An error occurred during AMS-HT C drying. Please go to Assistant for more details." }, { "ecode": "0500805B", "intro": "The cutting mat type is unknown; please replace it with the correct cutting mat." }, { "ecode": "07008016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "05008053", "intro": "The left and right nozzle is not matched with slicing file. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high." }, { "ecode": "0700C06E", "intro": "AMS A motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "0501401F", "intro": "Authorization timed out. Please make sure that your phone or PC has access to the internet, and ensure that the Bambu Studio/Bambu Handy APP is running in the foreground during the binding operation." }, { "ecode": "1807C06D", "intro": "AMS-HT H is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "1805C06A", "intro": "AMS-HT F is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "0C004029", "intro": "Material not detected. Please confirm placement and continue." }, { "ecode": "0300801E", "intro": "The extrusion motor is overloaded, please check the Assistant for details." }, { "ecode": "07068010", "intro": "The AMS assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "05014033", "intro": "Your APP region does not match with your printer; please download the APP in the corresponding region and register your account again." }, { "ecode": "18038005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "0500808A", "intro": "The BirdsEye Camera is installed offset. Please refer to the assistant to reinstall it." }, { "ecode": "18FE8005", "intro": "Failed to feed the filament outside the AMS-HT. Please clip the end of the filament flat and check to see if the spool is stuck." }, { "ecode": "07FE8010", "intro": "Check if the left external filament spool or filament is stuck." }, { "ecode": "07008012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "18FE8007", "intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, select \"Continue\"; if it is not, please push the filament forward slightly, and then select \"Retry\"." }, { "ecode": "18028010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "1801C06B", "intro": "AMS-HT B is changing filament. Unable to start drying. Please try again later." }, { "ecode": "07FFC00A", "intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, select \"Continue\"; if not, please push the filament forward slightly and then select \"Retry\"." }, { "ecode": "0700800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS A to the extruder is properly connected." }, { "ecode": "0500805E", "intro": "Cutting module Serial Number error: unable to calibrate or make project." }, { "ecode": "0500806A", "intro": "Unable to recognize the left and right hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please set hotend type on printer screen before next print." }, { "ecode": "1804C06B", "intro": "AMS-HT E is changing filament. Unable to start drying. Please try again later." }, { "ecode": "18008006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "03004067", "intro": "Calibration result is over the threshold." }, { "ecode": "07048005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "07FE8003", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder. (Connect a PTFE tube if you are about to use an AMS.)" }, { "ecode": "03008065", "intro": "The temperature of the MC module is too high. Please check the Wiki for possible explanations." }, { "ecode": "07018007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18024025", "intro": "Failed to read the filament information." }, { "ecode": "0500401B", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "0500805A", "intro": "Please place the cutting mat on cutting protection base." }, { "ecode": "0500402E", "intro": "System does not support the file system currently used by the USB flash drive. Please replace or format the USB flash drive to FAT32." }, { "ecode": "1805C06B", "intro": "AMS-HT F is changing filament. Unable to start drying. Please try again later." }, { "ecode": "1806C069", "intro": "An error occurred during AMS-HT G drying. Please go to Assistant for more details." }, { "ecode": "18028004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "07FF8001", "intro": "Failed to cut the filament of the right extruder. Please check the cutter." }, { "ecode": "05008059", "intro": "Cutting platform base is not correctly aligned. Please ensure that the four corners of the platform are aligned with the heatbed." }, { "ecode": "07FF8002", "intro": "The cutter of the right extruder is stuck. Please pull out the cutter handle." }, { "ecode": "07038021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "05FE8069", "intro": "Unable to recognize the left hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please manually set the hotend type." }, { "ecode": "07FF8020", "intro": "Extruder change failed; please refer to the assistant." }, { "ecode": "07FFC008", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "03004020", "intro": "The nozzle presence detection failed. Please check the Assistant for details." }, { "ecode": "0300800E", "intro": "The print file is not available. Please check to see if the storage media has been removed." }, { "ecode": "05004020", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07FEC010", "intro": "Insert the filament (over 30cm long) until it stops. You might see slight smoke during flushing. After insertion, close the front door and top cover." }, { "ecode": "05008013", "intro": "The print file is not available. Please check to see if the storage media has been removed." }, { "ecode": "03004006", "intro": "The nozzle is clogged." }, { "ecode": "07048007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "05004018", "intro": "Binding configuration information parsing failed; please try again." }, { "ecode": "07064025", "intro": "Failed to read the filament information." }, { "ecode": "18074025", "intro": "Failed to read the filament information." }, { "ecode": "07028003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "1805C06C", "intro": "AMS-HT F is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "1802C06D", "intro": "AMS-HT C is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "18FF8021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "1806C06B", "intro": "AMS-HT G is changing filament. Unable to start drying. Please try again later." }, { "ecode": "1803C06D", "intro": "AMS-HT D is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "18FF8020", "intro": "Extruder change failed; please refer to the assistant." }, { "ecode": "18058007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "0C00402A", "intro": "The visual marker was not detected. Please re-paste the paper in the correct position." }, { "ecode": "07FFC006", "intro": "Please feed filament into the PTFE tube of the right extruder until it can not be pushed any farther." }, { "ecode": "18058012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "07018023", "intro": "AMS B cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "03004068", "intro": "Step loss occurred during the motion accuracy enhancement process. Please try again." }, { "ecode": "1807C06E", "intro": "AMS-HT H motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "18068011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "10018004", "intro": "Prime Tower is not enabled and time-lapse mode is set to Smooth in slicing file. This may cause surface defects. Would you like to enable it?" }, { "ecode": "07068007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "03004009", "intro": "Homing XY axis failed." }, { "ecode": "18014025", "intro": "Failed to read the filament information." }, { "ecode": "07008006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS PTFE tube is connected." }, { "ecode": "05FE8053", "intro": "The left nozzle is not matched with slicing file. Please initiate the print after re-slicing, or continue printing after replacing the correct nozzle. Caution: the hotend temperature is high." }, { "ecode": "0707800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS H to the extruder is properly connected." }, { "ecode": "07068016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "0300400E", "intro": "The motor self-check failed." }, { "ecode": "0C004041", "intro": "Toolhead camera calibration failed. Please ensure the Calibration Marker on the heatbed or Height Calibration Marker on the homing area is clean and undamaged, then re-run the calibration process." }, { "ecode": "18038021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "03008049", "intro": "The current plate is invalid." }, { "ecode": "18078004", "intro": "AMS-HT failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "1000C003", "intro": "Enabling Timelapse in traditional mode may cause defects; please activate this feature as needed." }, { "ecode": "1805C06E", "intro": "AMS-HT F motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "0C008005", "intro": "Purged filament has piled up in the waste chute, which may cause a tool head collision." }, { "ecode": "07008021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "18078023", "intro": "AMS-HT H cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "1804C06D", "intro": "AMS-HT E is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "07FE8012", "intro": "Failed to get mapping table; please select \"Resume\" to retry." }, { "ecode": "05024006", "intro": "Unknown module detected, please try updating the firmware to the latest version." }, { "ecode": "0702800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS C to the extruder is properly connected." }, { "ecode": "18FE8001", "intro": "Failed to cut the filament of the left extruder. Please check the cutter." }, { "ecode": "0700C06C", "intro": "AMS A is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "07FF8024", "intro": "Extruder position calibration failed; please refer to the assistant." }, { "ecode": "03008000", "intro": "Printing was paused for unknown reason. You can select \"Resume\" to resume the print job." }, { "ecode": "0500401A", "intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before trying again." }, { "ecode": "0700C06A", "intro": "AMS A is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "05008069", "intro": "Unable to recognize the left and right hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please manually set the hotend type." }, { "ecode": "18068003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05004039", "intro": "The current task does not allow the installation of the laser/cutting module, and the task has been halted." }, { "ecode": "0703C06B", "intro": "AMS D is changing filament. Unable to start drying. Please try again later." }, { "ecode": "05004014", "intro": "Slicing for the print job failed. Please check your settings and restart the print job." }, { "ecode": "1801C06E", "intro": "AMS-HT B motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "0703C06A", "intro": "AMS D is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "18058006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "05014024", "intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before you try again." }, { "ecode": "07FF8007", "intro": "Please observe the nozzle of the right extruder. If the filament has been extruded, select \"Continue\"; if it is not, please push the filament forward slightly, and then select \"Retry\"." }, { "ecode": "07018004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "18028016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07054025", "intro": "Failed to read the filament information." }, { "ecode": "07FF8021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "0C00402D", "intro": "The toolhead camera is not working properly; please reboot the device." }, { "ecode": "1803800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT D to the extruder is properly connected." }, { "ecode": "07FEC003", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "07008005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "05008064", "intro": "Please place the Laser Platform correctly and ensure the rear markers are not blocked for laser calibration." }, { "ecode": "18058023", "intro": "AMS-HT F cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "0701C06D", "intro": "AMS B is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "07FFC011", "intro": "Please manually and slowly pull out the filament from the extruder. Then click “Continue”." }, { "ecode": "07FE8004", "intro": "Failed to pull back the filament from the left extruder. Please check whether the filament is stuck inside the extruder." }, { "ecode": "1800C06B", "intro": "AMS-HT A is changing filament. Unable to start drying. Please try again later." }, { "ecode": "1800C06E", "intro": "AMS-HT A motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "18FF8001", "intro": "Failed to cut the filament of the right extruder. Please check the cutter." }, { "ecode": "0C008009", "intro": "Build plate localization marker was not found." }, { "ecode": "0501401A", "intro": "Cloud access failed. Possible reasons include network instability caused by interference, inability to access the internet, or router firewall configuration restrictions. You can try moving the printer closer to the router or checking the router configuration before trying again." }, { "ecode": "05008081", "intro": "The left and right hotend is not installed." }, { "ecode": "18018010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "18008005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "03008016", "intro": "The nozzle is clogged with filament. Please cancel this print and clean the nozzle or select \"Resume\" to resume the print job." }, { "ecode": "05008084", "intro": "The Live View Camera is dirty; please clean it and continue." }, { "ecode": "18028006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "07078012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "1804800A", "intro": "PTFE tube disconnection detected. Please check if the PTFE tube from AMS-HT E to the extruder is properly connected." }, { "ecode": "05014031", "intro": "Device discovery binding is in progress, and the QR code cannot be displayed on the screen. You can wait for the binding to finish or abort the device discovery binding process in the APP/Studio and retry scanning the QR code on the screen for binding." }, { "ecode": "07078005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "03004010", "intro": "Nozzle offset calibration failed." }, { "ecode": "07028021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "18018005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "0703C06E", "intro": "AMS D motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "07FEC00A", "intro": "Please observe the nozzle of the left extruder. If the filament has been extruded, select \"Continue\"; if not, please push the filament forward slightly and then select \"Retry\"." }, { "ecode": "05004042", "intro": "Due to power limitations, starting AMS drying will pause current operations such as nozzle heating and fan running. Do you want to proceed with drying?" }, { "ecode": "05004008", "intro": "Starting printing failed; please power cycle the printer and resend the print job." }, { "ecode": "18038006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "07014025", "intro": "Failed to read the filament information." }, { "ecode": "18FEC008", "intro": "Please pull out the filament on the spool holder of the left extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "18034025", "intro": "Failed to read the filament information." }, { "ecode": "0500402F", "intro": "USB flash drive sector data is damaged; please format it. If it still cannot be recognized, please replace the USB flash drive." }, { "ecode": "0300801A", "intro": "Filament extrusion error; please check the assistant for troubleshooting. After resolving the issue, decide whether to cancel or resume the print job based on the actual print status." }, { "ecode": "07058007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "18FE8021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "05FF8080", "intro": "The right hotend is not installed." }, { "ecode": "0300800C", "intro": "Skipped step detected: auto-recover complete; please resume print and check if there are any layer shift problems." }, { "ecode": "18FF8013", "intro": "Timeout purging old filament of the right extruder: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "05024002", "intro": "Please go to “Settings > Calibration” to run the Motion Accuracy Enhancement Calibration before turning on Motion Accuracy Enhancement mode." }, { "ecode": "18018007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "07078004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "0500402D", "intro": "System exception" }, { "ecode": "07078023", "intro": "AMS H cooling failed. The ambient temperature may be too high. Please operate the device in a suitable environment." }, { "ecode": "07018021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "0300400B", "intro": "Internal communication exception" }, { "ecode": "1804C06C", "intro": "AMS-HT E is in Feed Assist Mode. Unable to start drying. Please try again later." }, { "ecode": "18028011", "intro": "AMS-HT filament ran out. Please insert a new filament into the same AMS-HT slot." }, { "ecode": "07078021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "18FE8024", "intro": "Extruder position calibration failed; please refer to the assistant." }, { "ecode": "03004042", "intro": "The Laser Safety Window is not properly installed. The task has been stopped." }, { "ecode": "07028007", "intro": "Failed to extrude the filament. Please check Assistant for more details." }, { "ecode": "05014025", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "07058004", "intro": "AMS failed to pull back filament. This could be due to a stuck spool or the end of the filament being stuck in the path." }, { "ecode": "18FE8002", "intro": "The cutter of the left extruder is stuck. Please pull out the cutter handle." }, { "ecode": "18FFC003", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "1805C069", "intro": "An error occurred during AMS-HT F drying. Please go to Assistant for more details." }, { "ecode": "18068013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "1803C06E", "intro": "AMS-HT D motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "05014022", "intro": "Cloud response is invalid. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "03004001", "intro": "The printer timed out waiting for the nozzle to cool down before homing." }, { "ecode": "18068010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "18048006", "intro": "Unable to feed filament into the extruder. The AMS may be mismatched with the extruder. You can rerun the AMS Setup. This could also be due to an entangled filament or a stuck spool. If not, please check if the AMS-HT PTFE tube is connected." }, { "ecode": "18078003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "0500401F", "intro": "Authorization timed out. Please make sure that your phone or PC has access to the internet, and ensure that the Bambu Studio/Bambu Handy APP is running in the foreground during the binding operation." }, { "ecode": "1804C069", "intro": "An error occurred during AMS-HT E drying. Please go to Assistant for more details." }, { "ecode": "1802C06E", "intro": "AMS-HT C motor is performing self-test. Unable to start drying. Please try again later." }, { "ecode": "07038005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "18004025", "intro": "Failed to read the filament information." }, { "ecode": "1000C002", "intro": "Printing CF material with stainless steel may cause nozzle damage." }, { "ecode": "18078010", "intro": "The AMS-HT assist motor is overloaded. This could be due to entangled filament or a stuck spool." }, { "ecode": "18078021", "intro": "AMS setup failed; please refer to the assistant." }, { "ecode": "07038017", "intro": "AMS D is drying. Please stop drying process before loading/unloading material." }, { "ecode": "0300800A", "intro": "A Filament pile-up was detected by AI Print Monitoring. Please clean filament from the waste chute." }, { "ecode": "0500808B", "intro": "The BirdsEye Camera setup failed. Please remove all objects and the mat on the heatbed to ensure the heatbed markers are visible. Meanwhile, please ensure the BirdsEye Camera is installed correctly and remove any obstructions that may block the camera's view." }, { "ecode": "1801C06A", "intro": "AMS-HT B is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "05008061", "intro": "No print plate detected. Please make sure it is placed correctly." }, { "ecode": "07FE8006", "intro": "Please feed filament into the PTFE tube of the left extruder until it can not be pushed any farther." }, { "ecode": "07FE8005", "intro": "Failed to feed the filament outside the AMS. Please clip the end of the filament flat and check to see if the spool is stuck." }, { "ecode": "05008080", "intro": "The left and right hotend is not installed." }, { "ecode": "05014018", "intro": "Binding configuration information parsing failed; please try again." }, { "ecode": "07048012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "0500806D", "intro": "Material not detected. Please confirm placement and continue." }, { "ecode": "03004008", "intro": "The AMS failed to change filament." }, { "ecode": "07018013", "intro": "Timeout purging old filament: Please check if the filament is stuck or the extruder is clogged." }, { "ecode": "03008051", "intro": "The cutting module has dropped or the cutting module cable is disconnected; please check the module." }, { "ecode": "05004017", "intro": "Binding failed. Please retry or restart the printer and retry." }, { "ecode": "05FE806A", "intro": "Unable to recognize the left hotend. It might be a non-official hotend, or the hotend mark could be dirty. Please set hotend type on printer screen before next print." }, { "ecode": "1800C06D", "intro": "AMS-HT A is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "0702C06A", "intro": "AMS C is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "18028005", "intro": "The AMS-HT failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "1807C06A", "intro": "AMS-HT H is reading RFID. Unable to start drying. Please try again later." }, { "ecode": "18FE8020", "intro": "Extruder change failed; please refer to the assistant." }, { "ecode": "07FFC003", "intro": "Please pull out the filament on the spool holder of the right extruder. If this message persists, please check to see if there is filament broken in the extruder or PTFE tube. (Connect a PTFE tube if you are about to use an AMS)" }, { "ecode": "18048003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05008055", "intro": "Laser module is installed, but a Cutting Platform is detected. Please place a Laser Platform and perform laser calibration." }, { "ecode": "07038003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "05014020", "intro": "Cloud access rejected. If you have tried multiple times and are still failing, please contact customer support." }, { "ecode": "05008074", "intro": "The Laser Platform is offset. Please ensure that the four corners of the platform are aligned with the heatbed, and the marker is not obstructed." }, { "ecode": "1807C069", "intro": "An error occurred during AMS-HT H drying. Please go to Assistant for more details." }, { "ecode": "1805C06D", "intro": "AMS-HT F is assisting in filament insertion. Unable to start drying. Please try again later." }, { "ecode": "1000C001", "intro": "High bed temperature may lead to filament clogging in the nozzle. You may open the chamber door." }, { "ecode": "18038016", "intro": "The extruder is not extruding normally; please refer to the Assistant. After trouble shooting. If the defects are acceptable, please resume." }, { "ecode": "07068012", "intro": "Failed to get AMS mapping table; please select \"Resume\" to retry." }, { "ecode": "03008061", "intro": "The mode of Airflow System failed to activate; check the air door condition." }, { "ecode": "05008083", "intro": "Material is not allowed in Mounting Calibration. Please remove the material from the platform." }, { "ecode": "18018003", "intro": "Failed to pull out the filament from the extruder. This might be caused by clogged extruder or filament broken inside the extruder." }, { "ecode": "03008007", "intro": "There was an unfinished print job when the printer lost power. If the model is still adhered to the build plate, you can try resuming the print job." }, { "ecode": "0C008018", "intro": "The foreign object detection function is not working. You can continue the task or view the assistant for troubleshooting." }, { "ecode": "07028005", "intro": "The AMS failed to send out filament. You can clip the end of your filament flat, and reinsert. If this message persists, please check the PTFE tubes in AMS for any signs of wear and tear." }, { "ecode": "03004044", "intro": "The Flame Sensor is abnormal. The sensor may be short-circuited. Please troubleshoot the issue before starting a print job." } ] } } }