When a per-layer nozzle grouping migrates a filament across nozzle
variants, the write-back turns two groups of config arrays from
filament-indexed into column-indexed: the per-variant filament options
(one column per variant a filament uses) and the merged extruder
retract overrides (resized to the column count by apply_override).
Export-path readers that still indexed them with the raw filament id
read a neighbor's column for every filament ordered after a migrating
one: toolchange/standby temperatures (M104/M109), retraction lengths
and feedrates, wipe distance, z-hop types, air-filtration keys, and -
through the Extruder's cached flow term - the extrusion E of every
move.
Now every such read resolves its column through the existing
layer-aware resolver (get_filament_config_index ->
Print::get_filament_config_indx), which returns the raw filament id
whenever no per-layer grouping result is published, so static prints
are byte-inert by construction. The Extruder itself has no layer
knowledge, so it gains an injected config column (set_config_index,
default = filament id) that the generator refreshes at the only two
resolution-changing events - layer change and writer toolchange - and
that re-syncs the cached e_per_mm3 flow term. Old-filament reads
resolve at the current layer, which is safe because the per-layer maps
are gap-filled carry-forward. Whole-array placeholder copies
(toolchange temperature overrides) are rebuilt in filament order,
mirroring the existing per-variant placeholder remap. The resolvers
move to the public section so non-friend helpers (ooze prevention) can
resolve too.
Documented, deliberately unchanged: the wipe tower's per-filament
parameter rows (no layer dimension; tower x per-layer grouping is a
follow-up), travel_slope's physical-extruder read, estimator pre-heat
bookkeeping temps, and index-0 header diagnostics.
Verification: new Extruder column-injection scenario (defaults, column
follow + flow-cache rescale, filament-indexed reads unaffected, reset
semantics) and a migrating write-back case proving the column shift for
filaments ordered after a migrator and the resolver tracking it (11 +
14 assertions); suites green (libslic3r 48998/169, fff_print 655/61);
20/20 pinned-slice byte gate bit-identical (incl. sequential repro x2
deterministic).
1.Should get value by filament id instead of extruder id
2.Fix many other issues caused by incorrect usage
jira:NONE
Signed-off-by: xun.zhang <xun.zhang@bambulab.com>
Change-Id: I3278d7de0f8976a97c9e5ccef80bba4a58553f5a
(cherry picked from commit 30c51dd1171fc16ba778308745fab2eb246aedd0)
(cherry picked from commit e9027478f8948352d99d33519994b044ca18a65a)
1. Set shared retract length size to 2. Filaments in one extruder
shares the param
2. Move toolchange function before unretract function in append_tcr
to get the correct logic
jira:NONE
Signed-off-by: xun.zhang <xun.zhang@bambulab.com>
Change-Id: I215a542ce36107071fad39f1f9e30234fb19a3a0
(cherry picked from commit c4ef6e9e0950c58a8c5f612662145c6a256884ad)
1. support recommended filament map when print by object
2. placeholder_parser support function filament_change
3. extruder_id of filament_map is start from 1
Change-Id: Ide8019cd4a165a25972f22706ff685c3005aa031
(cherry picked from commit b42d94e1d05236b8b7b2e65b4a24810eecf040cb)
* Supress warnings on unused functions an variables
Compilation of OrcaSlicer produces 3056 warnings.
Nearly half of them related to unused functions and variables.
It is unlikely we going to clean them up since we may want to
keep code base as close to the BBS as possible
* initialize class member with correct value
* Fix memset arguments order
* Merge multiple statemensts into single
* fix -Wpessimizing-move
the amount of total extruded material and per extruder extruded material
up to the point the value is evaluated:
"extruded_volume", "extruded_weight",
"extruded_volume_total", "extruded_weight_total"
Add the option to use non-relative extrusion in printer config screen. Some extruders do not play well with relative extrusion...
Remove reference to multi-extruder
Remove reference to multi-extruder
change g-code comment for M83 relative extrusion
changed comment for M83
Remove commented line of code
In this specific case, we delete the old line of code because it refers to a variable that was deleted from the rest of the code (RELATIVE_E_AXIS)