Sorry had to re-create the PR as I did some chaos in my repo with CLI. xD

Fixes issue https://github.com/OrcaSlicer/OrcaSlicer/issues/10971

Description:
Fix wipe tower filament selection and clean up tool ordering. Added wipe_tower_filament handling to WipeTower2 (store config, mark non-selected tools as “soluble,” and use it in toolchange selection) and ensured the configured wipe‑tower extruder is included in the extruder list for ordering. Removed duplicated/merged tool‑ordering code (extra insert_wipe_tower_extruder definition, duplicate declaration, and redundant reorder block) so the tool order logic runs only once.

<img width="1819" height="799" alt="image" src="https://github.com/user-attachments/assets/cef39026-cf6a-46da-a87a-ef895774699f" />
This commit is contained in:
Argo
2026-02-10 03:56:38 +01:00
committed by GitHub
parent 039a693b25
commit ed3f0e2898
6 changed files with 55 additions and 13 deletions

View File

@@ -187,6 +187,7 @@ private:
bool m_semm = true; // Are we using a single extruder multimaterial printer?
bool m_enable_filament_ramming = true;
bool m_is_mk4mmu3 = false;
int m_wipe_tower_filament = 0; // 1-based config value, 0 means auto
Vec2f m_wipe_tower_pos; // Left front corner of the wipe tower in mm.
float m_wipe_tower_width; // Width of the wipe tower.
float m_wipe_tower_depth = 0.f; // Depth of the wipe tower