mirror of
https://github.com/OrcaSlicer/OrcaSlicer.git
synced 2026-09-11 02:57:39 +00:00
Fix unit test:
This commit is contained in:
@@ -1216,17 +1216,20 @@ TEST_CASE("Published 3MF prefers a compatible preset over an exact but incompati
|
|||||||
petg.config.opt_string("filament_type", 0u) = "PETG";
|
petg.config.opt_string("filament_type", 0u) = "PETG";
|
||||||
petg.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.6 };
|
petg.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.6 };
|
||||||
// The bare-named legacy preset (Bambu-printer only) and the exact author preset are both
|
// The bare-named legacy preset (Bambu-printer only) and the exact author preset are both
|
||||||
// incompatible with the receiver's printer.
|
// incompatible with the receiver's printer. update_compatible() recomputes is_compatible
|
||||||
|
// inside load_config_model, so the incompatibility is expressed the way production derives
|
||||||
|
// it: a compatible_printers constraint no receiver printer satisfies (the fresh bundle's
|
||||||
|
// active printer is the "Default Printer" placeholder).
|
||||||
Preset &bare = add_inmemory_preset(bundle.filaments, "Generic PLA");
|
Preset &bare = add_inmemory_preset(bundle.filaments, "Generic PLA");
|
||||||
bare.config.opt_string("filament_type", 0u) = "PLA";
|
bare.config.opt_string("filament_type", 0u) = "PLA";
|
||||||
bare.config.opt_string("filament_vendor", 0u) = "Generic";
|
bare.config.opt_string("filament_vendor", 0u) = "Generic";
|
||||||
bare.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
bare.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
||||||
bare.is_compatible = false;
|
bare.config.set_key_value("compatible_printers", new ConfigOptionStrings({ "Unrelated Printer" }));
|
||||||
Preset &qidi = add_inmemory_preset(bundle.filaments, "Generic PLA @Qidi Q2 0.4 nozzle");
|
Preset &qidi = add_inmemory_preset(bundle.filaments, "Generic PLA @Qidi Q2 0.4 nozzle");
|
||||||
qidi.config.opt_string("filament_type", 0u) = "PLA";
|
qidi.config.opt_string("filament_type", 0u) = "PLA";
|
||||||
qidi.config.opt_string("filament_vendor", 0u) = "Generic";
|
qidi.config.opt_string("filament_vendor", 0u) = "Generic";
|
||||||
qidi.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
qidi.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
||||||
qidi.is_compatible = false;
|
qidi.config.set_key_value("compatible_printers", new ConfigOptionStrings({ "Unrelated Printer" }));
|
||||||
// The receiver's own compatible library preset.
|
// The receiver's own compatible library preset.
|
||||||
Preset &sys = add_inmemory_preset(bundle.filaments, "Generic PLA @System");
|
Preset &sys = add_inmemory_preset(bundle.filaments, "Generic PLA @System");
|
||||||
sys.config.opt_string("filament_type", 0u) = "PLA";
|
sys.config.opt_string("filament_type", 0u) = "PLA";
|
||||||
@@ -1264,11 +1267,15 @@ TEST_CASE("Published 3MF falls back to an incompatible exact preset when no comp
|
|||||||
Preset &petg = add_inmemory_preset(bundle.filaments, "My PETG");
|
Preset &petg = add_inmemory_preset(bundle.filaments, "My PETG");
|
||||||
petg.config.opt_string("filament_type", 0u) = "PETG";
|
petg.config.opt_string("filament_type", 0u) = "PETG";
|
||||||
petg.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.6 };
|
petg.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.6 };
|
||||||
|
// The exact author preset is incompatible with the receiver's printer. update_compatible()
|
||||||
|
// recomputes is_compatible inside load_config_model, so the incompatibility is expressed the
|
||||||
|
// way production derives it: a compatible_printers constraint the receiver's printer (the
|
||||||
|
// fresh bundle's "Default Printer" placeholder) does not satisfy.
|
||||||
Preset &qidi = add_inmemory_preset(bundle.filaments, "Generic PLA @Qidi Q2 0.4 nozzle");
|
Preset &qidi = add_inmemory_preset(bundle.filaments, "Generic PLA @Qidi Q2 0.4 nozzle");
|
||||||
qidi.config.opt_string("filament_type", 0u) = "PLA";
|
qidi.config.opt_string("filament_type", 0u) = "PLA";
|
||||||
qidi.config.opt_string("filament_vendor", 0u) = "Generic";
|
qidi.config.opt_string("filament_vendor", 0u) = "Generic";
|
||||||
qidi.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
qidi.config.opt<ConfigOptionFloatsNullable>("filament_retraction_length", true)->values = { 0.5 };
|
||||||
qidi.is_compatible = false;
|
qidi.config.set_key_value("compatible_printers", new ConfigOptionStrings({ "Unrelated Printer" }));
|
||||||
bundle.filament_presets = { "My PETG" };
|
bundle.filament_presets = { "My PETG" };
|
||||||
|
|
||||||
PublishedMaterialEntry entry;
|
PublishedMaterialEntry entry;
|
||||||
|
|||||||
Reference in New Issue
Block a user