ENH: add warning info when bed temperature is too high
Add bed temperature checker in gcode processer. And save slice warning into GcodeProcessorResult. Signed-off-by: salt.wei <salt.wei@bambulab.com> Change-Id: Iee96e4ab165a3171a5a1e165450bfc360401647f
This commit is contained in:
@@ -1767,7 +1767,8 @@ void SelectMachineDialog::on_ok_btn(wxCommandEvent &event)
|
||||
|
||||
//Check Printer Model Id
|
||||
bool is_same_printer_type = is_same_printer_model();
|
||||
confirm_text += _L("The printer type used to generate G-code is not the same type as the currently selected physical printer. It is recommend to re-slice by selecting the same printer type.\n");
|
||||
if (!is_same_printer_type)
|
||||
confirm_text += _L("The printer type used to generate G-code is not the same type as the currently selected physical printer. It is recommend to re-slice by selecting the same printer type.\n");
|
||||
|
||||
//Check slice warnings
|
||||
bool has_slice_warnings = false;
|
||||
@@ -1776,9 +1777,13 @@ void SelectMachineDialog::on_ok_btn(wxCommandEvent &event)
|
||||
if (dev) {
|
||||
MachineObject* obj_ = dev->get_selected_machine();
|
||||
for (auto warning : plate->get_slice_result()->warnings) {
|
||||
if ((obj_->printer_type == "BL-P001" || obj_->printer_type == "BL-P002") && warning.msg == BED_TEMP_TOO_HIGH_THAN_FILAMENT) {
|
||||
confirm_text += Plater::get_slice_warning_string(warning) + "\n";
|
||||
} else {
|
||||
if (warning.msg == BED_TEMP_TOO_HIGH_THAN_FILAMENT) {
|
||||
if ((obj_->printer_type == "BL-P001" || obj_->printer_type == "BL-P002")) {
|
||||
confirm_text += Plater::get_slice_warning_string(warning) + "\n";
|
||||
has_slice_warnings = true;
|
||||
}
|
||||
}
|
||||
else {
|
||||
has_slice_warnings = true;
|
||||
}
|
||||
}
|
||||
|
||||