mirror of
https://github.com/OrcaSlicer/OrcaSlicer.git
synced 2026-10-01 21:01:12 +00:00
Fix redundant QIDI startup tool changes (#15096)
* Fix redundant QIDI startup tool changes Guard Q2, X-Max 4, and X-Plus 4 filament-change G-code so same-tool startup selections do not run the full cut, unload, and purge sequence. * Guard Q2C against redundant startup tool changes Skip the complete filament-change sequence when the requested tool is already selected during startup. * Bump Qidi profile version
This commit is contained in:
@@ -17,7 +17,7 @@
|
||||
"cooling_tube_length": "0",
|
||||
"parking_pos_retraction": "0",
|
||||
"extra_loading_move": "5",
|
||||
"change_filament_gcode": "G1 Z{max_layer_z + 3.0} F1200\nTOOL_CHANGE_START F=[current_extruder] T=[next_extruder]\nBUFFER_MONITORING ENABLE=0\nDISABLE_ALL_SENSOR\nM106 S255\nMOVE_TO_TRASH\n{if long_retractions_when_cut[previous_extruder]}\nG1 E-{retraction_distances_when_cut[previous_extruder]} F{old_filament_e_feedrate}\n{else}\nG1 E-10 F{old_filament_e_feedrate}\n{endif}\nM400\nCUT_FILAMENT T=[current_extruder]\nMOVE_TO_TRASH\nM106 P2 S0\nUNLOAD_T[current_extruder]\nT[next_extruder]\n{if nozzle_temperature_range_high[current_extruder] >= nozzle_temperature_range_high[next_extruder]}\nM104 S{nozzle_temperature_range_high[current_extruder]}\n{else}\nM104 S{nozzle_temperature_range_high[next_extruder]}\n{endif}\n; FLUSH_START\nM106 S25\nG1 E30 F300\n; FLUSH_END\n{if long_retractions_when_cut[previous_extruder]}\nG1 E{retraction_distances_when_cut[previous_extruder]} F{old_filament_e_feedrate}\n{endif}\n{if flush_length_1 > 1}\n; FLUSH_START\n{if flush_length_1 > 23.7}\nG1 E23.7 F{old_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{old_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\n{else}\nG1 E{flush_length_1} F{old_filament_e_feedrate}\n{endif}\nG1 E-[old_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_2 > 1}\n; FLUSH_START\nG1 X92 F9000\nG1 E[old_retract_length_toolchange] F300\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_3 > 1}\n; FLUSH_START\nG1 X85 F9000\nG1 E[new_retract_length_toolchange] F300\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_4 > 1}\n; FLUSH_START\nG1 X92 F9000\nG1 E[new_retract_length_toolchange] F300\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\nM400\nM106 S255\nM104 S[new_filament_temp]\nINIT_SYNC_BUFFER_STATE\nBUFFER_MONITORING ENABLE=1\nG1 E10 F25 \nM109 S[new_filament_temp]\nG1 E-5 F1800\nCLEAR_OOZE\nTOOL_CHANGE_END\nG1 Y270 F8000\nM106 S0\nG1 E2 F1800\nENABLE_ALL_SENSOR\n",
|
||||
"change_filament_gcode": "{if current_extruder != next_extruder}\nG1 Z{max_layer_z + 3.0} F1200\nTOOL_CHANGE_START F=[current_extruder] T=[next_extruder]\nBUFFER_MONITORING ENABLE=0\nDISABLE_ALL_SENSOR\nM106 S255\nMOVE_TO_TRASH\n{if long_retractions_when_cut[previous_extruder]}\nG1 E-{retraction_distances_when_cut[previous_extruder]} F{old_filament_e_feedrate}\n{else}\nG1 E-10 F{old_filament_e_feedrate}\n{endif}\nM400\nCUT_FILAMENT T=[current_extruder]\nMOVE_TO_TRASH\nM106 P2 S0\nUNLOAD_T[current_extruder]\nT[next_extruder]\n{if nozzle_temperature_range_high[current_extruder] >= nozzle_temperature_range_high[next_extruder]}\nM104 S{nozzle_temperature_range_high[current_extruder]}\n{else}\nM104 S{nozzle_temperature_range_high[next_extruder]}\n{endif}\n; FLUSH_START\nM106 S25\nG1 E30 F300\n; FLUSH_END\n{if long_retractions_when_cut[previous_extruder]}\nG1 E{retraction_distances_when_cut[previous_extruder]} F{old_filament_e_feedrate}\n{endif}\n{if flush_length_1 > 1}\n; FLUSH_START\n{if flush_length_1 > 23.7}\nG1 E23.7 F{old_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{old_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\nG1 E{(flush_length_1 - 23.7) * 0.02} F50\nG1 E{(flush_length_1 - 23.7) * 0.23} F{new_filament_e_feedrate}\n{else}\nG1 E{flush_length_1} F{old_filament_e_feedrate}\n{endif}\nG1 E-[old_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_2 > 1}\n; FLUSH_START\nG1 X92 F9000\nG1 E[old_retract_length_toolchange] F300\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E{flush_length_2 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_2 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_3 > 1}\n; FLUSH_START\nG1 X85 F9000\nG1 E[new_retract_length_toolchange] F300\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E{flush_length_3 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_3 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\n{if flush_length_4 > 1}\n; FLUSH_START\nG1 X92 F9000\nG1 E[new_retract_length_toolchange] F300\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E{flush_length_4 * 0.18} F{new_filament_e_feedrate}\nG1 E{flush_length_4 * 0.02} F50\nG1 E-[new_retract_length_toolchange] F1800\n; FLUSH_END\n{endif}\nM400\nM106 S255\nM104 S[new_filament_temp]\nINIT_SYNC_BUFFER_STATE\nBUFFER_MONITORING ENABLE=1\nG1 E10 F25 \nM109 S[new_filament_temp]\nG1 E-5 F1800\nCLEAR_OOZE\nTOOL_CHANGE_END\nG1 Y270 F8000\nM106 S0\nG1 E2 F1800\nENABLE_ALL_SENSOR\n{endif}\n",
|
||||
"default_filament_profile": [
|
||||
"QIDI PLA Rapido @Qidi Q2C 0.4 nozzle"
|
||||
],
|
||||
|
||||
Reference in New Issue
Block a user