mirror of
https://github.com/OrcaSlicer/OrcaSlicer.git
synced 2026-05-20 03:43:52 +00:00
update WIKI for exhuast/auxiliar fan and active chamber temperature features
This commit is contained in:
@@ -1 +1,35 @@
|
||||
WIP
|
||||
OrcaSlicer use `M106 P2` command to control auxiliary cooling fan.
|
||||
|
||||
If you are using Klipper, you can define a `M106` macro to control the both normal part cooling fan and auxiliary fan and exhuast fan.
|
||||
Below is a reference configuration for Klipper.
|
||||
*Note: Don't forget to change the pin name to the actual pin name you are using in the configuration*
|
||||
|
||||
```
|
||||
# instead of using [fan], we define the default part cooling fan with [fan_generic] here
|
||||
# this is the default part cooling fan
|
||||
[fan_generic fan0]
|
||||
pin: PA7
|
||||
cycle_time: 0.01
|
||||
hardware_pwm: false
|
||||
|
||||
# this is the auxiliary fan
|
||||
# comment out it if you don't have auxiliary fan
|
||||
[fan_generic fan2]
|
||||
pin: PA8
|
||||
cycle_time: 0.01
|
||||
hardware_pwm: false
|
||||
|
||||
# this is the exhaust fan
|
||||
# comment out it if you don't have exhaust fan
|
||||
[fan_generic fan3]
|
||||
pin: PA9
|
||||
cycle_time: 0.01
|
||||
hardware_pwm: false
|
||||
|
||||
[gcode_macro M106]
|
||||
gcode:
|
||||
{% set fan = 'fan' + (params.P|int if params.P is defined else 0)|string %}
|
||||
{% set speed = (params.S|int if params.S is defined else 255) %}
|
||||
SET_FAN_SPEED FAN={fan} SPEED={speed}
|
||||
|
||||
```
|
||||
|
||||