Fix the pre-send advisories and port the remaining send-flow checks

This commit is contained in:
SoftFever
2026-07-17 12:10:45 +08:00
parent 7f8baf46d3
commit 37e27a24c4
7 changed files with 109 additions and 29 deletions

View File

@@ -1958,13 +1958,6 @@ bool SelectMachineDialog::CheckWarningSmartNozzleBlobAuto(MachineObject* obj_)
return true;
}
std::optional<FilamentInfo> SelectMachineDialog::get_slicing_filament_info(int fila_logic_id) const
{
for (const auto& fila : m_filaments)
if (fila.id == fila_logic_id) return fila;
return std::nullopt;
}
std::optional<FilamentInfo> SelectMachineDialog::get_mapped_filament_info(int fila_logic_id) const
{
for (const auto& fila : m_ams_mapping_result)
@@ -2400,9 +2393,15 @@ void SelectMachineDialog::show_status(PrintDialogStatus status, std::vector<wxSt
} else if (status == PrintStatusTPUUnsupportAutoCali) {
Enable_Refresh_Button(true);
Enable_Send_Button(false);
} else if (status == PrintStatusTPUUnsupportCaliOn) { // Orca: TPU manual-cali-on gate (resync)
} else if (status == PrintStatusTPUUnsupportCaliOn) { // Orca: TPU manual-cali-on ADVISORY (resync) — Send stays enabled
Enable_Refresh_Button(true);
Enable_Send_Button(false);
Enable_Send_Button(true);
} else if (status == PrintStatusTPUUnsuggestCali) { // Orca: TPU flow-cali advisory (resync) — non-blocking
Enable_Refresh_Button(true);
Enable_Send_Button(true);
} else if (status == PrintStatusSmartNozzleBlobNeedAuto) { // Orca: blob switch-to-Auto advisory (resync) — non-blocking
Enable_Refresh_Button(true);
Enable_Send_Button(true);
} else if (status == PrintStatusHasFilamentInBlackListError) {
Enable_Refresh_Button(true);
Enable_Send_Button(false);
@@ -2948,6 +2947,10 @@ void SelectMachineDialog::EnableEditing(bool enable)
{
iter.second->enable(enable);
}
// Orca: grey the best-position "saves X" tip when editing is disabled so an error transition
// doesn't leave a stale clickable tip (resync).
if (m_saveTimeText) enable ? m_saveTimeText->Enable() : m_saveTimeText->Disable();
}
/*content height > FromDIP(650), make the area scrollable*/
@@ -4087,6 +4090,11 @@ void SelectMachineDialog::on_timer(wxTimerEvent &event)
update_show_status(obj_);
update_print_status_msg();
//update_scroll_area_size();/*STUDIO-12867 the page maybe blank in some platform. FIXME*/
// Orca: refresh the best-position "saves X" tip after the status update (resync). Placed here (not
// inside update_show_status) so it still runs when update_show_status returns early on an error.
// No-op for printers without a filament switcher.
refresh_save_time(obj_);
}
void SelectMachineDialog::on_selection_changed(wxCommandEvent &event)
@@ -4760,17 +4768,17 @@ void SelectMachineDialog::update_show_status(MachineObject* obj_)
}
}
// Orca: gate both flow-cali cases for TPU/Aero on printers that don't support PA auto-cali (REF
// parity). "auto" -> AutoCali, "on" -> CaliOn, matching REF's distinct messages now that the
// CaliOn status exists in PrePrintChecker (this cluster). Both block Send.
// Orca: TPU/Aero flow-cali gate on printers that don't support PA auto-cali (REF parity). Only the
// "auto" case BLOCKS (AutoCali). The "on" case is a non-blocking ADVISORY (CaliOn): the printer uses
// the previous cali value and skips, so Send stays enabled and we do NOT return (matches REF, which
// puts CaliOn in the warning band and only returns on is_error).
if (!can_support_pa_auto_cali() && m_checkbox_list["flow_cali"]->IsShown()) {
if (m_checkbox_list["flow_cali"]->getValue() == "auto") {
show_status(PrintDialogStatus::PrintStatusTPUUnsupportAutoCali);
return;
}
if (m_checkbox_list["flow_cali"]->getValue() == "on") {
show_status(PrintDialogStatus::PrintStatusTPUUnsupportCaliOn);
return;
show_status(PrintDialogStatus::PrintStatusTPUUnsupportCaliOn); // advisory: no return
}
}
@@ -4986,12 +4994,14 @@ void SelectMachineDialog::update_show_status(MachineObject* obj_)
// Orca: smart-nozzle-blob pre-send suggestion (resync). When the file has stringing-prone filament
// and the printer's clumping detection isn't already Auto, offer a clickable "Switch" that sets the
// detection to Auto (mode 2). Rendered via the Orca callback-link path (add_with_link).
// detection to Auto (mode 2). Rendered via the Orca callback-link path (add_with_link) with the
// message passed as a literal (no get_pre_state_msg entry) so the tail add() doesn't also push a
// second, linkless copy — mirrors the TimelapseStorageLow convention.
if (!CheckWarningSmartNozzleBlobAuto(obj_)) {
show_status(PrintDialogStatus::PrintStatusSmartNozzleBlobNeedAuto);
m_pre_print_checker.add_with_link(
PrintDialogStatus::PrintStatusSmartNozzleBlobNeedAuto,
m_pre_print_checker.get_pre_state_msg(PrintDialogStatus::PrintStatusSmartNozzleBlobNeedAuto),
_L("There is stringing-prone filament in this file. For best print quality, we recommend switching nozzle clumping detection to Auto mode."),
_L("Switch"),
[] {
DeviceManager* dev = wxGetApp().getDeviceManager();
@@ -5001,8 +5011,23 @@ void SelectMachineDialog::update_show_status(MachineObject* obj_)
});
}
// Orca: refresh the best-position "saves X" tip (resync); no-op for printers without a switcher.
refresh_save_time(obj_);
// Orca: TPU flow-cali advisory (resync, non-blocking). When Flow Dynamics Calibration is Auto/On and
// a mapped filament is in the printer's auto_on_cali_warning_tpu_filaments list, warn that the system
// will use the manual/default value and skip flow calibration. Send stays enabled.
if (obj_ && m_checkbox_list.count("flow_cali") && m_checkbox_list["flow_cali"]->IsShown()
&& m_checkbox_list["flow_cali"]->getValue() != "off") {
const auto& warning_tpu_filaments =
DevPrinterConfigUtil::get_value_from_config<std::vector<std::string>>(obj_->printer_type, "auto_on_cali_warning_tpu_filaments");
if (!warning_tpu_filaments.empty()) {
for (const auto& fila : m_ams_mapping_result) {
if (std::find(warning_tpu_filaments.begin(), warning_tpu_filaments.end(), fila.filament_id) != warning_tpu_filaments.end()) {
show_status(PrintDialogStatus::PrintStatusTPUUnsuggestCali,
{ _L("If 'Dynamic Flow Calibration' is set to Auto/On, the system will use the manual calibration value or the default value and skip the flow calibration process. You can perform a manual flow calibration for TPU filament on the 'Calibration' page.") });
break;
}
}
}
}
if (m_ams_mapping_res) {
if (has_timelapse_warning()) {
@@ -6131,6 +6156,7 @@ void SelectMachineDialog::set_default_from_sdcard()
::sprintf(weight, "%.2f g", float_weight); // ORCA remove spacing before text
m_stext_time->SetLabel(time);
m_stext_weight->SetLabel(weight);
refresh_save_time(obj_); // Orca: mirrors REF; no-op for FROM_SDCARD_VIEW (refresh_save_time early-returns)
}